HomeMy WebLinkAboutP101 Plumbing PlanCHROME WALL C(
ANDSCREW
PLUGGED TEE
WITH CLEANOUT
BALANCE OF PIPING SAME
AS CLEANOUT TO GRADE
MOUNTING NOT AND WASHER
(TYPICAL)
MAY EXTEND AS
WASTE OR VENT
LINE
1/4" TO 3/8" COMPRESSION
NO HUB MAY
FITTING
BE USED.
CONBRACO 340 SERIES ASSE
FINISHED FLOOR
1070 MIXING VALVE
1/8" C.I. BEND
REFERENCED ON DRAWING AS"WCO" TTO INC REX TO
OIOOPPPER
PRIOR
(TYP.) WALL CLEANOUT (WCO) DETAIL °`VES OR FIXTURES. TYR.
3
SCALE: NONE '
s MIXING VALVE
P101 SCALE: NO SCALE
SPOUT
PLATE
COPPER SUPPLY TUBE
3/8" BACK CHECK VALVE
(TYPICAL)
COMPRESSION STOPS
Equipment Schedule
WGi WATER CLOSET FLOOR MOUNTED FLOOR OUTLET KOHLER PERSUADE)CIRC
COMFORT HEIGHT® TWO-PIECE ELONGATED DUAL -FLUSH TOILET WITH TOP -MOUNT ACTUATOR AND SKIRTED TRAPWAY
AND CHROME ANGLE STOP. (OR APPROVED EQUAL.)
LAV-1 LAVATORY WALL HUNG UNLIMITED 60 BY WS BATH COLLECTIONS, 23.6" X 17.7" X 4.3", BATHROOM SINK IN
CERAMIC WHITE, ANZZI "FORZA" SERIES SINGLE HOLE SINGLE -HANDLE LOW -ARC FAUCET IN POLISHED CHROME,
CHROME'P' TRAP AND ANGLE STOPS. (OR EQUAL). INSTALL PROW RAP INSULATED DRAIN AND WATER LINES.
UR-1 KOHLER "DEXTER" WHITE VITREOUS CHINA URINAL WITH MOTION ACTIVATED SLOAN FLUSH VALVE
MS-1 FIAT MSBID2424100, SERVICE BASIN 24 X 24 X 10 INCH SINGLE BOWL MOP WHITE. FAUCET, LEVER, 1/2" FNPT, 2,
CAST BRASS,CHICAGO FAUCETS, ZORO #: G1339326 MFR #: 897-RCF
Plumbing Notes
1. PIPE AND DUCT HANGERS SHALL BE UNISTRUCT 2000 WITH 5116" RODS AND LITCHFIELD CLIC SYSTEMS 316 S.S.
ACCESSORIES. CLIC PIPE SUPPORT CLAMPS OR UNI-CUSHION CLAMPS. SIZE OF CLAMPS SHALL BE DETERMINED BY TI
MANUFACTURER BASED ON THE TYPE AND LOAD OF EACH SYSTEM.
2. ALL WATER PIPING SHALL BE TYPE'L' COPPER ASTM B-88 HARD WI ANSI B16.22 WROUGHT COPPER FITTINGS AND
NONLEAD SOLDERED JOINTS. UNDERGROUND PIPING SHALL BE TYPE W SOFT ASTM B-88 W/ NO JOINTS AND ROLLED
RADIUS TURNS UNKINKED. PEX IS ALSO ACCEPTABLE IF ALLOWED BY LOCAL AUTHORITY.
3. ALL GAS PIPING SHALL BE SCHEDULE 40 ASTM A-120153 W/ MALLEABLE IRON 125 LB. FITTINGS. ALL JOINTS SHALL BE
TEFLON TAPE AND PIPING CAULKED.
4. ALL CONDENSATE SHALL BE ASTM A-53 SCHEDULE 80 WI ANSI B16.3 FITTINGS 300 LB. SCREWED.
WH-1 WATER HEATER (BRADFORD WHITE LE130L3-3.4500w ELEMENT, 36 GPH RECOVERY RATE AT 100 DEGREES 5. ALL SANITARY SEWER SHALL BE CAST IRON SCHEDULED 40 HUBLESS CISPI STANDARD 301-78 OR SCHEDULE 40 PVC
TEMPERATURE RISE, T&P VALVE, SHELF BRACKET, EXPANSION TANK. (OR APPROVED EQUAL.) PROVIDE HEAT TRAPS ON I ASTM D-2665. ANY PIPING LOCATED EXPOSED OR IN A RETURN AIR PLENUM SPACE SHALL BE CAST IRON. VENT PIPING
WATER INLET AND OUTLET. BY TENANT CONTRACTOR. SIMULTANEOUS ELEMENT OPERATION SHALL BE THE SAME MATERIAL AS SANITARY SEWER.
WH-2 WATER HEATER EXISTING ABOVE TOILET ROOMS, 150OW SINGLE PHASE ELEMENT 6 GPH RECOVERY RATE AT 100
DEGREES TEMPERATURE RISE, T&P VALVE, SHELF BRACKET, EXPANSION TANK. (OR APPROVED EQUAL.) PROVIDE HEAT
TRAPS ON WATER INLET AND OUTLET
FD-1 4" DIA. FLOOR DRAIN ZORN 415-1-ZB W/ TRAP PRIMER1/2" (OR APPROVED EQUAL.)
FS-1 ZURN #ZB 1910, 8-1/2" SQ. TOP, 6" DEEP, DOME STRAINER. HALF GRATE
F.C.O. CLEAN OUT ZURN Z-1402.(OR APPROVED EQUAL)
MI WATTS SERIES L70AF HOT WATER EXTENDER MIXING VALVE SEE DETAIL THIS SHEET
W.C.O. WALL CLEANOUTZURN
GT-1 GREASE TRAP - SEE SHEET P102.
FLOOR DEVICES CAN BE SUBSTITUTED WITH EQUAL IN SOUIX CHIEF BRAND
Pipe Legend
-w-w -a.- GAS LINE
COLD WATER LINE
SANITARY SEWER (UNDERGROUND
UNLESS OTHERWISE NOTED)
VENT
HOTWATERLINE
6. VALVES SHALL BE OF THE TYPE AND DESIGN FOR SERVICES BEING USED.
BALL- BRONZE BODY 125 LB. WOG NIBCO T OR S-580Y.
GATE - 8-111.
GLOBE- S-211.
CHECK- S413-B.
GAS COCKS- " NORDSTROM 142.
OTHER APPROVED MANUFACTURERS ARE APOLLO, STICKHAM, GRINNELL, HAMMOND, WALWORTH, LUNKENHEIMER,
CRANE OR MILWAUKEE. (OR EQUAL)
7. INSULATION FOR PIPING SYSTEMS SHALL BE INSTALLED AS PER MANUFACTURERS INSTRUCTIONS AND
RECOMMENDED INSTALLATION PROCEDURES.
WATER LINES - 1/2" CLOSED CELLED FOAM BY HALLSTEAD OR ARMAFLEX FR/UL. OPTIONAL 1/2" FIBERGLASS ASTM
C-547 WI ASJ JACKETAND PRE MOLDED PVC FRILL FITTINGS BY KNAUF, OCR OR SCHUELLER. (OR EQUAL.)
STORM SEWER -SAME AS ABOVE.
CONDENSATE SHALL BE 3/4" FIBERGLASS - SAME AS ABOVE.
A: INSULATE ALL WATER LINES, COLD AND HOT, AND ALL HORIZONTAL STORM SEWER PIPING. R ALL INSULATION
SHALL HAVE A GALVANIZED SLEEVE WHEN RESTING ON THE INSULATION.
B. ANY EXPOSED PIPING SHALL HAVE A CHROME ESCUTCHEON PLATE WHERE EXPOSED IN FINISH ROOMS. ALL PIPI
THAT PASS THROUGH A FIRE WALL SHALL BE CAULKED AROUND PENETRATION WI A FLAME RETARDENT UL SEALANT 1
MAINTAIN RATINGS ON WALL. SILICONE CAULK ALL FIXTURES AROUND PERIMETER AFTER FINAL PAINTING OF WALLS.
9. ALL PIPING SYSTEMS SHALL BE PRESSURE TESTED FOR 24 HOURS BEFORE FINAL CONNECTION TO EXISTING IN
ACCORDANCE W/ CODES.
10. ALL FIXTURES SHALL BE AS SHOWN ON THE DRAWINGS AS TO TYPE AND MATERIALS BY EWER, KOHLER, CRANE,
AMERICAN STANDARD, ZURN, WADE, JOSAM, DELANY, SLOAN, PRICE, MOEN, POWERS, SPEAKMAN, CHICAGO FAUCET,
BEMIS, OLSONITE, FIAT. (OR APPROVED EQUAL.)
ocz
L
7
Cn
C
O
U
U)
(1)
0
SO
of
7580481h Street, S.E.
Grand Rapids, Mi. 49512
P. 616.634.2253
GIenn@rdo-llc.cam
1
m CV
U O
C6 C� Cfl
i CV Nr
Z
F- c])
comma)
U U) E
co
LO
v
06/25/2019 Construction
08/28/2019 Grease Trap
LOW
PSG\STpj��Q .
i No. AR11000167 j
F