Loading...
HomeMy WebLinkAboutT101 Title SheetSheet Index T101 COVER SHEET D101 DEMOLITION FLOOR PLAN A101 ARCHITECTURAL FLOOR PLAN A102 FINISH PLAN A201 EQUIPMENT/FIXTURE PLAN AND DETAILS A202 INTERIOR ELEVATION A203 INTERIOR ELEVATIONS A301 TOILET ROOM DETAILS M101 MECHANICAL PLAN E101 ELECTRICAL POWER PLAN E102 ELECTRICAL LIGHTING PLAN E103 ELECTRICAL SPECS AND PANELS P101 PLUMBING PLAN RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Camel DATE: 09/04/19 PROJECT LOCATIO Carmel, IN Code Review Summary Building Code, 2014 Edition (IBC, 2012 Edition, 1st printing) ANSI A117.1-2009 Plumbing Code, 2012 Edition (IPC, 2006 Edition) Electrical Code2009 Edition (NFPA 70-2008) Mechanical Code, 2014 Edition (IMC, 2012 Edition, 1st printing) Energy Conservation Code 2010 (ASHRAE 90.1, 2007 edition, as amended) Fire Code, 2014 Edition (IFC 2012 Edition, 1 st printing) Fuel Gas code, 2014 Edition (IFGC, 2012 Edition, 2nd printing) SI-A117.1: AMERICANS WITH DISABILITIES ACT (ADA) THE FOLLOWING WILL BE DEFERRED SUBMITTALS: - FIRE ALARM MODIFICATIONS - FIRE SPRINKLER MODIFICATIONS STORIES: 1 STORY TYPE OF CONSTRUCTION: TYPE -313- PROTECTED FULLY SPRINKLERED _ASE SPACE AREA: 5,000 SF. SE GROUP: ASSEMBLY A-3 (SIMILAR IN OPERATION TO A BOWLING ALLEY) CCUPANCYLOAD 4R/ENTRY AREA: 73 SF/ 15 SFPP = 25 PEOPLE IMULATOR AREA: SIMULATORS ESIGN LOAD OF 4 ACTIVE PLAYERS AND 4 WAITING PER SIMULATOR OCCUPANTS/SIMULATOR X 6 = 48 PEOPLE FFICE AREA: 100 SF/100 SFPP = 1 PERSON FORAGE AREA: 179 SF/ 200 SFPP = 1 PEOPLE DTAL LOAD: 75 PEOPLE WATER WILL BE PROVIDED AT BAR FREE OF CHARGE UPON REQUEST NOTE: THIS IS A TENANT SPACE IN AN EXISTING SHOPPING CENTER THAT HAS BEEN PREVIOUSLY OCCUPIED AS A MERCANTILE USE. Project General Notes ALL WORK SHALL CONFORM TO THE CODES LISTED HEREIN, AND ALLOT HER APPLICABLE CODES, STANDARDS, AND REGULATIONS OF STATE AND LOCAL AUTHORITIES. IT IS INTENDED THAT A COMPLETE OCCUPIABLE BUILDING PROJECT IS PROVIDED. THE GENERAL CONDITIONS OF THE CONTRACT FOR CONSTRUCTION (A.I.A. 1997 EDITION) AREA PART OF THESE CONTRACT DOCUMENTS. A COPY IS ON FILE AT THE ARCHITECTS OFFICE. DO NOT SCALE THESE DRAWINGS. VERIFY ALL DIMENSIONS AND CONDITIONS IN THE HELD. ANY DISCREPANCIES IN THESE DRAWINGS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO SUBMISSION OF BID IN THE FORM OF A "REQUEST FOR INFORMATION". FAILURE TO DO SO WILL BE AT THE EXPENSE OF THE CONTRACTOR ALL PROPOSED SUBSTITUTIONS SHALL BE APPROVED BY THE CONSTRUCTION MANAGER, IN WRITING, PRIOR TO INSTALLATION. G.C. IS RESPONSIBLE FOR SUBMITTAL, PAYING FEES AND OBTAINING ALL PERMITS ASSOCIATED WITH THE PROJECT. THIS INCLUDES, BUT IS NOT LIMITED TO ELECTRICAL, MECHANICAL, PLUMBING, ENCROACHMENT PERMIT, ETC. G.C. REQUIRED TO PAY FOR TEMPORARY FACILITIES FEES AS REQUIRED TO COMPLETE THE WORK IN A TIMELY MANNER. ALL ABBREVIATIONS INCLUDED FOLLOW INDUSTRY STANDARDS. CONTACT ARCHITECT IF ANY ABBREVIATIONS ARE NOT CLEAR. ALL BIDDERS ARE RESPONSIBLE TO VERIFY ALL CONDITIONS IN THE FIELD PRIOR TO PROVIDING BIOS FAILURETODOSO WILL RESULT IN CHANGE ORDERS BEING REJECTED. GENERAL CONTRACTOR IS RESPONSIBLE FOR PROVIDING PORTABLE TOILETS IF REQUIRED. CONSTRUCTION DUMPSTER IS TO BE LOCATED PER THE LANDLORD INSTRUCTION. CONTRACTORS SHALL PARK IN LOCATIONSAS DICTATED BY LANDLORD. Scope of Work 1. DEMOLITION TO INCLUDE: REMOVAL OF CONCRETE FLOOR FOR PLUMBING CONNECTION AS NECESSARY FOR CONNECTION TO EXISTING WATER SUPPLY & ELECTRICAL CONDUIT w/ PULL STRINGS NEAR EXISTING RESTROOMS TO BAR AREA (SEE P101 FOR LOCATIONS) (SEE E101 FOR ELECTRICAL LOCATIONS). 2. EXISTING ELECTRICAL SERVICE TO REMAIN, CONNECT CIRCUITS AS SHOWN ON E103. 3. BUILD NEW INTERIOR WALLS AS SHOWN. ALL WALLS DRY WALLED AND TAPED, MUDDED, SANDED, AND READY FOR PAINT ( VERIFY WITH OWNER). 4. LEVEL & CLEAN SLAB READY FOR NEW FLOOR COVERINGS. 5. EXISTING MECHANICAL UNITS IN SPACE TO BE CLEANED TO LIKE NEW CONDITION. 6. PROVIDE & INSTALL ELECTRICAL CONDUITS w/ PULL STINGS AS NECESSARY FOR ELECTRICAL RUNS TO BAR. SEE E102 LIGHTING LAYOUT 7. EXISTING MIENS AND WOMEN'S RESTROOMS AS SHOWN NEW FINISHES IN BOTH. 8. SPRINKLING SYSTEM AND FIRE ALARM SYSTEM TO BE ALTERED BY OTHERS, SHOP DRAWINGS TO BE PROVIDED BY FIRE PROTECTION CONTRACTOR TO CITY FOR APPROVAL UNDER SEPARATE DEFERRED SUBMISSION. Design Professional in Charge Glenn R. Rahn 7580 48th St SE Grand Rapids, MI 49512 Phone: 616-634-2253 U J J N C W Tn C O U C a� 0 a� 7580 48th Street, S.E. Grand Rapids, Mi. 49512 P. 616.634.2253 Glenn@rdo-llc.wnn a m N U O NOtD i N � Z F— N _ N C O USE � (0 LID U v L J O DATE ISSUED FOR: 06/25/2019 Construclion wpl001111119 �ENN . PLO\S TF4 FO`. a i No. AR11000167 `; we i w£' ,'a/ � IH I1T1ElG THIS DRAWING IS THE SOLE PROPERTY OF RETAIL DESIGN CONSULTANTS LLC AND IS A COPYRIGHTED DOCUMENT AND IS NOT TO BE USED OR REPRODUCED WITHOUT WRITTEN CONSENT. T101