HomeMy WebLinkAboutElectricalRELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Camel DATE: 09/04/19 1 ELECTRICAL LOCATION & EQUIPMENT PLAN PLAN B' 4' °' B E 118" = V-0" GENERAL NOTES - ELECTRICAL A. REFER TO GENERAL NOTES AND REFER ENCESPEC I FICATIONS ON SHEET A001&A021 FOR SPECIFICATIONS REGARDING NEW CONSTRUCTION AND ELECTRICAL/LIGHTING. B. See detail 4/AOO l for typical installation a lignment requirements for eleciricc l devices. C. Refer to Construction Floor Plans(A21 Series Sheets) for additions l Miscellaneous Specialties & Equipment items that may not be indicated on this sheet. D. All dimensions are from finished wall surface or column centedine to centerline of outlets or centerline of pairs of outlets, E All wall mounted wiring devices and receptacles shown back-to-back shall be offset a minimum of 8and acoustically sealed. F Where direct connection to prewlad furl panels occurs, provide power and telecommunication feeds to indicated panel locations from wall, column or floor source directly adjacent to this location, G. All existing floor mounted electrical/telecommunication locations which are not reused are to be removed. Remove all associated cable, wire and conduit back to the source. Propedy patch and repair affected wall, floor and/or ceiling construction. H. Unless otherwise noted, all device elevations refer to centedine. J. Refer to Reflected Ceiling Plans(A22 Series Sheets) for locations of light switches. K. All outlets that are in the vicinity of any wet areas (kitchens, break rooms, restrooms, janitorial rooms with floor sinks, laundry rooms, stand alone wall mounted sinks, electrical water fountains, etc.) ground fault circuit interrupt (G.F.C.I.) type. See Electrical Legend. L Furniture will be provided by tenant and is shown for reference only. M. If SUBS or more of the total number of light fixtures or luminaires are replaced, provide lighting and occupancy controls per 2015 IECC. N. Provide emergency lighting as required by code. MECH, ELEC, & PLUMBING DESIGN REQ. I. Refer to attached M, E, & P drawings for more information. If drawings are not included and scope requires M, P, or E work Contractor shall provide design build - design and permitting services for the scope required for a successful project. 2. The design and installation of all MEP systems shall comply with the current Codes in force by the AEU at the project location. Any required energy compliance or environmental reports required by the Al shall be prepared by the Contractor if not provided by the Owner or Architect's consultants. 3. Contractor to field verify all existing building conditions and systems affected by the project work a no be familiar will the drawings and project requirements prior to bid or contracting with Owner. No structural cuffing, coring, or drilling shall be performed that impacts any part of the existing facility, without prior approval. Contractor shall retain the services of a structural engineer, if required by the Architect Owner, or AHJ to obtain a required approval. 4. Architectural drawing have been provided to show the locations of all devices and systems. Contractor shall be responsible for reconfigurations, modifications, and/or new work needed to provide a complete functioning job without permanently disrupting existing Wilding systems. Contractor shall coordinate with Owner, Building Facilities, and or other Tenants 48 hours minimum in advance of any interruption of any building service. 5. Architectural drawings shall take precedence over all other trades drawings when conflicts arise. Contractor to bring conflicts or inconsistencies between the architectural drawngs and the drawing of other trades to the attention of the architect prior to bid, order, or installation. 6. Fire sprinkler modifications and new work shall be designed by a licensed fire sprinkler system designer in the state the project resides in, and must be installed by a state licensed installer. Contractor shall obtain any required approvals from the AHJ prior to start of construction. 7. Zoning of MEP systems shall be exclusive to the project area without cross over to other building areas, except as is indicated on the documents or as approved in advance. 8. Contractor to provide all required test and balance reports, O&M manuals, and commissioning activities required by the AHJ or project requirements in the appropriate phases of the project. 9. Existing hard duct to remain as is. No new ductwork required. Rework flexible duct to new diffuser locations. Note: E.C. and/or design build contractor is to verify that project meets India no ASH RAE 90.1 energy codes. Design intent is to be within wafts per sold are foot. Provide energy managment controls, such as sensorconfrols (ultrasonic and motion detection) and/or relay time clods, as required by the code. Indiana required energy compliance report (ComCheck) is the responsibility of the ownerorowners representative. Drawings, specifications and energy control devices are shown with the intent of meeting current state energy codes. Submitting party is to alert designer and owner of my additional devices or load changes necessary to amere to the code prior to submission of ComCheck. V 0 ELECTRICAL LEGEND NOTE: Standard outlet height Is 18- A.F.F. (U.O.N.) Existing we I mounted outlet Wall mounted quadruplex outlet to remain (Grey Color). 4 at standard height. Wall mounted duplex outlet at standard height. Wall mounted dedicated duplex outlet on dedicated circuit at standard height. Wall mounted duplex ground fault circuit interrupt outlet at standard height. Indicates power pole location. IThermostat Indicates area not in contract. Referto floor plans for atltlifional information. Wall mounted data outlet. 0 Wall mounted cable television box. z Wall mounted telephone and data q shared outlet (I Data / I Voice U.O.N.) Wall mounted direct connection location for power and telephone/ data for systems furniture panels. �p4❑� '—V Coordinate exact location(s) and requirements with fumiture dealer and installer. +42" Special mounting height indication forwall outlets. Taken to centerline. O KEYED NOTES - ELECTRICAL El Verify power pole location with lumiture provided by tenant. E2 ADA ALT. NO.1 - see general notes on sheet A211 fa more information. 3 ;ARSON DESIGN ASSOCIATES MIDWEST 9229 Delegates Row Suite 250 Indianapolis, IN 46240 Tel 317.843.5979 Fax 31 T843.5975 SOUTHWEST 12301 Research Blvd Bldg IVSuite130 Austin, TX 78759 Tel512977.0520 Fax 512977.0384 - (irsondesign.com 0 U O C; ^H W W STAMP: 0 N, W h II N t 00 OR W cM O CD M 06.07.19 ISSUE: A Permit Set 06.07.19 DRAWING TITLE: Electrical Location & Equipment Plan JOB NO. 11827705 DATE: 06.07.19 SHEET NUMBER: A23 1 CARSON DESIGN ASSOCATS