1 ELECTRICAL LOCATION & EQUIPMENT PLAN PLAN B' 4' °' B E
118" = V-0"
GENERAL NOTES - ELECTRICAL
A. REFER TO GENERAL NOTES AND REFER ENCESPEC I FICATIONS ON SHEET A001&A021 FOR
SPECIFICATIONS REGARDING NEW CONSTRUCTION AND ELECTRICAL/LIGHTING.
B. See detail 4/AOO l for typical installation a lignment requirements for eleciricc l devices.
C. Refer to Construction Floor Plans(A21 Series Sheets) for additions l Miscellaneous Specialties
& Equipment items that may not be indicated on this sheet.
D. All dimensions are from finished wall surface or column centedine to centerline of outlets or
centerline of pairs of outlets,
E All wall mounted wiring devices and receptacles shown back-to-back shall be offset a
minimum of 8and acoustically sealed.
F Where direct connection to prewlad furl panels occurs, provide power and
telecommunication feeds to indicated panel locations from wall, column or floor source
directly adjacent to this location,
G. All existing floor mounted electrical/telecommunication locations which are not reused are
to be removed. Remove all associated cable, wire and conduit back to the source.
Propedy patch and repair affected wall, floor and/or ceiling construction.
H. Unless otherwise noted, all device elevations refer to centedine.
J. Refer to Reflected Ceiling Plans(A22 Series Sheets) for locations of light switches.
K. All outlets that are in the vicinity of any wet areas (kitchens, break rooms, restrooms, janitorial
rooms with floor sinks, laundry rooms, stand alone wall mounted sinks, electrical water
fountains, etc.) ground fault circuit interrupt (G.F.C.I.) type. See Electrical Legend.
L Furniture will be provided by tenant and is shown for reference only.
M. If SUBS or more of the total number of light fixtures or luminaires are replaced, provide lighting
and occupancy controls per 2015 IECC.
N. Provide emergency lighting as required by code.
MECH, ELEC, & PLUMBING DESIGN REQ.
I. Refer to attached M, E, & P drawings for more information. If drawings are not
included and scope requires M, P, or E work Contractor shall provide design build -
design and permitting services for the scope required for a successful project.
2. The design and installation of all MEP systems shall comply with the current Codes
in force by the AEU at the project location. Any required energy compliance or
environmental reports required by the Al shall be prepared by the Contractor if
not provided by the Owner or Architect's consultants.
3. Contractor to field verify all existing building conditions and systems affected by
the project work a no be familiar will the drawings and project requirements prior
to bid or contracting with Owner. No structural cuffing, coring, or drilling shall be
performed that impacts any part of the existing facility, without prior approval.
Contractor shall retain the services of a structural engineer, if required by the
Architect Owner, or AHJ to obtain a required approval.
4. Architectural drawing have been provided to show the locations of all devices
and systems. Contractor shall be responsible for reconfigurations, modifications,
and/or new work needed to provide a complete functioning job without
permanently disrupting existing Wilding systems. Contractor shall coordinate with
Owner, Building Facilities, and or other Tenants 48 hours minimum in advance of
any interruption of any building service.
5. Architectural drawings shall take precedence over all other trades drawings
when conflicts arise. Contractor to bring conflicts or inconsistencies between the
architectural drawngs and the drawing of other trades to the attention of the
architect prior to bid, order, or installation.
6. Fire sprinkler modifications and new work shall be designed by a licensed fire
sprinkler system designer in the state the project resides in, and must be installed
by a state licensed installer. Contractor shall obtain any required approvals from
the AHJ prior to start of construction.
7. Zoning of MEP systems shall be exclusive to the project area without cross over to
other building areas, except as is indicated on the documents or as approved in
advance.
8. Contractor to provide all required test and balance reports, O&M manuals, and
commissioning activities required by the AHJ or project requirements in the
appropriate phases of the project.
9. Existing hard duct to remain as is. No new ductwork required. Rework flexible
duct to new diffuser locations.
Note: E.C. and/or design build contractor is to verify that project meets India no ASH RAE
90.1 energy codes. Design intent is to be within wafts per sold are foot. Provide energy
managment controls, such as sensorconfrols (ultrasonic and motion detection) and/or
relay time clods, as required by the code. Indiana required energy compliance report
(ComCheck) is the responsibility of the ownerorowners representative. Drawings,
specifications and energy control devices are shown with the intent of meeting current
state energy codes. Submitting party is to alert designer and owner of my additional
devices or load changes necessary to amere to the code prior to submission of
ComCheck.
V
0
ELECTRICAL LEGEND
NOTE: Standard outlet height Is 18- A.F.F. (U.O.N.)
Existing we I mounted outlet Wall mounted quadruplex outlet
to remain (Grey Color). 4 at standard height.
Wall mounted duplex outlet
at standard height.
Wall mounted dedicated duplex
outlet on dedicated circuit at
standard height.
Wall mounted duplex ground
fault circuit interrupt outlet at
standard height.
Indicates power pole
location.
IThermostat
Indicates area not in
contract. Referto floor
plans for atltlifional
information.
Wall mounted data outlet.
0
Wall mounted cable television box.
z
Wall mounted telephone and data
q
shared outlet (I Data / I Voice
U.O.N.)
Wall mounted direct connection
location for power and telephone/
data for systems furniture panels.
�p4❑�
'—V
Coordinate exact location(s) and
requirements with fumiture dealer
and installer.
+42" Special mounting height indication
forwall outlets. Taken to centerline.
O KEYED NOTES - ELECTRICAL
El Verify power pole location with lumiture provided by tenant.
E2 ADA ALT. NO.1 - see general notes on sheet A211 fa more information.
3
;ARSON
DESIGN
ASSOCIATES
MIDWEST
9229 Delegates Row
Suite 250
Indianapolis, IN 46240
Tel 317.843.5979 Fax 31 T843.5975
SOUTHWEST
12301 Research Blvd
Bldg IVSuite130
Austin, TX 78759
Tel512977.0520 Fax 512977.0384
- (irsondesign.com
0
U O
C; ^H
W W
STAMP:
0
N,
W
h
II
N
t
00
OR
W
cM
O
CD
M
06.07.19
ISSUE: A
Permit Set 06.07.19
DRAWING TITLE:
Electrical Location &
Equipment Plan
JOB NO. 11827705
DATE: 06.07.19
SHEET NUMBER:
A23 1