HomeMy WebLinkAboutGeneral Notes - Building Elements A003BUILDING ELEMENTS NOTE: All conditions are not represented in these details. If is the responsibility of the Genera l Contractor to comply with a l l applicable codes, to include accessibilityrequirements. The details shown have been provided as a courtesy.
Water Closets and Toilet Compartments.
Fal
WHEELCHAIR AMBULATORY
ACCESSIBLE ACCESSIBLE
WATER CLOSETS WATER CLOSETS
(Required if total toilet
+ urinal fixture count is
greater than 6)
TOILET COMPARTMENT _
CLEARANCES
eIQ Clear
f Floor
Space
Toe Clearance � quire
of front and ONE side
EXCEPTION: Toe 56" MIN.At
clearance not required of dull Wall Hung W
front partition if 62" depth
at Wall Hung WC or 65 59" MIN. At
depth of Floor Mounted
WC. Toe Clearance not dull Floor Mounte
required at side partition if WC and all
66" clear width is Children's WC
provided.
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and Local Codes
City of Camel
DATE: 09/04/19
NOTE. The required clearance around the
water closet shall be permitted to ovedap the
water closet, associated grab bars, dispenses,
sonitarynapkin disposal units, coat hooks,
shelves, accessible routes, clear floor space
Cleor and clearances required at otherfixtures, and
Floor thetumingspace. No other fixtures or
Space obstructions shall be located within the
required wafer closet clearance(INCLUDING
LAVATORIES), Lavatories may overlap the
required clearance of wafer closets of private
residential dwelling units ONLY.
Door Location AMBU LATORY ACCESSIBLE TOILET
COMPARTMENT CLEARANCES
Doors of Toilet Compartments
to comply with 404 (excluding
latch side approach
clearance width required,
which shall be as shown in the
diagram to the left). Doors
Shot be self closing, with a
door pull complying with
404.2.7 placed on both sides
of the door, near the latch.
Door may not swing into the
required minimum Clear Floor
Space.
Coats and Shelves (if
provided) shall be Installed
within Reach Ranges as
specified in 308.
r 7�
E
i
4 i
42"MIN. 60" MIN.
CHAPTER 8: SPECIAL ROOMS + CONDITIONS
Kitchens4
Provide the following minimum
clearances IF/WHEN a
coodop
and/or conventional range
is present, ONLY.
o oFl�]
oior--
o o
--;k,q
R f.
�
Ref.
�yy
�� ��Qr ��
t- `
Min.
MO
PASS-THRU KITCHEN
U-SHAPED KITCHEN
U-SHAPED KITCHEN
Provide maneuvering clearances to Seating, Furnishings and Tables, as per 305 fora
Forward Approach. Knee and toe clearances complying with 306 shall be provided.
17' -2S' MAX. to
of Toe Clears
IF built-in Dining or Work
Surface is within Accessible
Route, provide end panel as
o required for Protruding Objects
'? �26" Min. & 30" Max. where
Dashed Line represents m� Dining and Work Surfaces are
minimum Knee Clearance 6„ primarily for Children Use
requirements, as per 306.3 MAX.
DINING SURFACES AND WORK NOTE: Reference 904 for off
SURFACES HEIGHT REQUIREMENTS requirements of Check -Out Aisles
and Service Counters
CHAPTER 10: RECREATION FACILITIES
Reference 1004 for Clear Floor Space Requirements adjacent to Exercise Machines
and equipment.
GRAB BAR. FLUSH CONTROLS. & SEAT HEIGHT
REQUIREMENTS
y 54 41" Grab Bar Ryp.)
y-
3_
" Minn. - _ -36"MIN.
i 24" i 12"
rLL
Side I \',/ .I-Ib"-IS'
Side Wall Flush / Back Wall
4A^nA4v
Mirrors
MIRROR ABOVE
LAVATORY OR
COUNTERTOP
FULL-LENGTH
MIRROR
URINALS
131/7'Min.
131/2" Min.
NOTE: Provide
o
Clear Fl car Space
E
complying with
Forward
Approach (305)
I
of accessible
s
Wall
Hung Type
Stall Type
Controls I
Hof wafer and drain pipes under lavatories and handicap
LAVATORY AND SINK REQUIREMENTS accessible sinks shall be installed or otherwise configured 17MIN,Ss
to protect against contact. 25" MAX. TO EDGE
17' Min.
5" Max.
i
f. M
6"Max. "Min.
II"Min.
LAVATORY SINK
Inside Stall
~Padifion
7
6"
MIN.
z wz
Required foe
J Cis
E
clearance of front
¢ a. 4 iu
I and ONE side
O—
:_ z
partition.
I 'Min.
Dashed Line represents minimum OF TOE CLEARANCE
25' Max
Knee Clearance requirements,
PARALLEL APPROACH IS
as per 306.3
PERMITTED FOR LAVATORIES
O
BY CHILDREN AGES ANO
UNDER.
MIN.
;io
J
m�
�DOshed
6"
I I" MIN. NOTE: Provide 24"
Line represents Clear Floor
MAX.
clearance to bottom of
Space requirements, as per 305
sink/apron and 31"to fop
COU NTER MOUNTED SINK rim of sink for Lavatories
PLAN
and Sinks used primarily
by children aged 6-12
MOUNTING HEIGHTS FOR WATER CLOSETS SERVING AGES 3 THROUGH 12
GRADE LEVEL/AGE
WC
CENTERLINE
TOILET SEAT
HEIGHT
GRAB BAR
HEIGHT
DISPENSER
HEIGHT
Ages and 4
12"
11"-12"
18"-20"
14"
Ages and
12"-15"
12"-15"
20"-25"
I4"-17"
Ages 9 and 12
15"-ISIP
15"-17,
25"-27"
I7"-19"
C 3
CARSON
DESIGN
ASSOCIATES
SOUTHWEST
12301 Research Blvd.
Bldg IV - Suite 130
Austin, TX 78759
Tel 512.977.0520 Fax 512.977.0384
14607 San Pedro, Suite195
San Antonio, TX 78232
Tel 210.878.0062 Fax 210.495.0579
MIDWEST
9229 Delegates Row Suite 250
Indianapolis, IN 46240
Tel 31 ] 843.5979 Fax 317.843.5975
www.carsondesigacom
Z
Y
_N
o
O
N
Q
0.
C
N
PIZ
0�T��
C
fn
N
U
a
}
N
w
Y
M
O
O
M
STAMP:
PRELIMINARY
Not for regulatory approval,
permitting, or construction
Edward P. Richburg
Texas Registered Architect 14094
06.07.19
ISSUE:
Permit Set
DRAWING TITLE:
2009 ICC/ANSI A117.1
Restrooms & Parking
JOB NO. 11827705
DATE: 06.07.19
SHEET NUMBER:
A003
COPYPIGM 206