Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
General Notes - Cover Sheet
C 3 CARSON DESKN ASSOCIATES Architecture / Design Contact Carson Design Associates 9229 Delegates Row Julie Berry Suite 250 Phone: 317.843.3760 Indianapolis, IN 46240 )berry@carsondesign.com RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Camel DATE: 09/04/19 Reach Magazine Keystone Office Park Suite 207 3003 E. 98th Street, Indianapolis, IN Properly Manager / Bldg. Owner Cushman and Wakefield 6081 East 82nd Street David Moore Suite 100 Phone: 317.570.7000 Indianapolis, IN 46250 david.moore@cushwake.com 06,07,19 1827705 I. Refer to attached M, E, & P drawings for more information. If drawings are not included and scope requires M, P, or E work Contractor shall provide design build - design and permitting services for the scope required for a successful project. 2. The design and installation of all MEP systems shall comply with the current Codes in force by the AHJ at the project location. Any required energy compliance or environmental reports required by the AHJ shall be prepared by the Contractor if not provided by the Owner or Architect's consultants. 3. Contractor to field verify all existing building conditions and systems affected by the project work and be familiarwith the drawings and project requirements prior to bid or contracting with Owner. No structural cuffing, coring, or drilling shall be performed that impacts any part of the existing facility, without prior approval. Contractorshall retain the services of a structural engineer, if required by the Architect. Owner, or AHJ to obtain a required approval. 4. Architectural drawing have been provided to show the locations of all devices and systems. Contractor shall be responsible for reconfigurations, modifications, and/or new work needed to provide a complete functioning job without permanently disrupting existing building systems. Contractor shall coordinate with Owner, Building Facilities, and or other Tenants 48 hours minimum in advance of any interruption of any building service. 5. Architectural drawings shall fake precedence over all other trades drawings when conflicts arise. Contractor to bring conflicts or inconsktencies between the architectural drawings and the drawing of other trades to the attention of the architect prior to bid order, or installation. 6. Fire sprinkler modifications and new work shall be designed by a licensed fire sprinkler system designer in the state the project resides in, and must be installed by a state licensed installer. Contractor shall obtain any required approvals from the AHJ prior to start of construction. 7. Zoning of MEP systems shall be exclusive to the project area without cross over to other building areas, except as is indicated on the documents or as approved in advance. 8. Contractor to provide all required test and balance reports, O&M manuals, and commissioning activities required by the AHJ or project requirements in the appropriate phases of the project. 9. Existing hard duct to remain as is. No new ductwork required. Re -work flexible duct to new diffuser locations. Note: E.C. and/or design build contractor is to verify that project meets Indiana ASHRAE 90.1 energy codes. Design intent is to be within watts per square foot. Provide energy monagment controls, such as sensor controls (ultrasonic and motion defection) and/or relay time clocks, as required by the code. Indiana rewired energy compliance report (ComCheck) 6 the responsibility of the owner or owners representative. Drawings, specifications and energy control devices are shown with the intent of meeting current state energy codes. Submitting party is to alert designer and owner of any additional devices or load changes necessary to adhere to the code prior to submission of ComCheck. Drawing Usl Sheet Number Sheet Name A000 Cover Sheet A001 General Information and Standard Details A002 20091CC/ANSI A117J A003 20091CC/ANSI A117.1 Restrooms & Parking A011 Code Information A021 Project Standards A201 Demolition Plan A201.1 Demolition RCP Plan A211 Construction Floor Plan A221 Reflected Ceiling Plan A231 Electrical Location & Equipment Plan A241 Finish Plan and Notes A251 Furniture Plan A501 Inferior Elevations A601 Door Schedule This project consists of the demolition and finish out of an existing demised tenant suite. Suite occupancy classification and use group remains unchanged by the scope of this work. Minor mechanical and ductwork relocations to accommodate new partition layout. Electrical circuits to accommodate new tenant equipment loads and locations. Area Map Project Location i z 3• mw..e " 5 § ar i n, Fee - a©" Quo ;min are r,�.. Farmer Larri Me Friend TRUE C 3 CARSON DESIGN ASSOCIATES MIDWEST 9229 Delegates Row Suite 250 Indianapolis, IN 46240 Tel 317.843.5979 Fax 317.843.5975 SOUTHWEST 12301 Research Blvd Bldg IV -Suite 130 Austin, T% 78759 Tel 512.977.0520 Fax 512.977.0384 www.corsondesign.com Z ^, W 6 Q Q 'N a a 0 N U i N CC) O C �1 t = y N U O t ll y a N w M 0 0 M STAMP: `"OTvtvM\CH ur4iii �( °7jvpi STE f Fy�!•. 9 O R 7 DIA O xt%,11Rc I n oTvvvvv` 06.07.19 ISSUE: Permit Set 06.07.19 DRAWING TITLE: Cover Sheet JOB NO. 11827705 DATE: 06.07.19 SHEET NUMBER: A000 COPYRIGHT IDI) CPR9H DESIGN