HomeMy WebLinkAboutStructural - Construction PlanRELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes e City of Camel (� �1VTl�ilmnrJAaAz+L DATE: \ 09/04/19 Attach deflection slip track to underside of deck. Provide sealant for acoustical and/or fire rated wall types as designated. U.L. Listed fire rated sealant (I /4 bead) @ fire rated wall types. Refer to UL assembly anti/or Suspended acoustical acoustical manufacturer ceiling tie - refer to guidelines. room finish schedule. Sound batt insulation Spacer as required, typ above dialing. Extend Contnuousacoustical 2'-0" min. each side of tape typ wall. _`USG or Eq. 20UB Metal 'V Trim continuous, Suspended acoustical floated -in, typical. ceiling tie - refer to Metal top track room finish schedule. channel, continuous, Install fasteners at 2'-0' Refer to wall type o.c., max schedule forwall construction. Refer to wall type D /. V schedule forwall construction. Framed to Framed to ceiling deck above grid TOP OF WALL CONDITION DETAILS R-10 SCHEDULE - WALL TYPES Wall Construction Top of Wall Construction Wall Type Stud Size Insulation Fire Rating U.L. or G.A. IF I Description Code Description M3 0' -3 5/8' No -- Metal studs @ 16" O.C. with Ill layer 5/8'gypsum board each side G Fmmed to ceiling grid M3S 0' -3 5/8' Yes Metal studs @ 16" O.C. with Ill layer 5/8" gypsum board each side D Framed to deck above lu v Recortls 203 D v, Breakroom Server C2 203 Bus. Manager Reception 'o on:L? 4 213 212 ua D 202 200 G MaG p� as O D ram+ D 202 G 201 Me G 5' 0" CLEAR re Sales Open Office f_ as G G 216 C3 /S, o GRestr 9 9Resource Room M 204 w "'U Support OOffice 217 Office 208 Sales Open Office Office 207 210 201 Graphics Office 205 II= open to orci Conference 206 CONSTRUCTION FLOOR PLAN PLAN B' 4' Of B' 1e 1/8" 1' 0" GENERAL NOTES - CONSTRUCTION A. REFERTO GENERAL NOTES AND REFERENCE SPECIeCA➢ONS ON SHEETA001&A021 FOR SPECIFICATIONS REGARDING NEW CONSTRUCTION AND HNISHES. B. Refer to Reflected Ceiling Plans (A22 Series Sheeh) for ceiling heights unless otherwise Indicated. C. Refer to Electrical Location Plans (A23 Series Sheets) for additional Miscellaneous Specialties & Equipment items that may not be indicated on this sheet. D. Refer to Finish Plan and Finish Notes (A24 Series Sheets) for wall base type and ceiling types. E. Refer to top of wall condition details, this sheet, for additional information regarding wall heights and termination. F. Provide air -fight acoustical and/or fireratedsealant around perimeter of all wall types with acoustical insulation. G. All joints and penetrations of fire rated assemblies to be sealed with approved U.L. listed "F" and 'T'systems. Submit product data and installation information prior to Installation for Architect's approval. Label/identify fire rated partitions for future reference on each side of wall above ceiling, concealed from view. Note the UL assembly designation with 6" red stenciled letters H. Dimensions are taken from the face of masonry walls, cdumn centerlines, finish face of existing walls and/or stud face of new walls unless otherwise indicated. J. Verify all critical dimensions within and/or related to the existing building. Dimensions and conditions indicated were determined by visual survey and/or information from existing drawings. K. +/- Dimension is equal to verify in field. L. Plans are not to be scaled for finish or wall information. Contractor to contact Architect for any questions or clarifications on plan dimensions. M. Walls behind and directly adjacent to all toilet room fixtures (lavatories, toilets and urinals) shall have a smooth, hard, non-absorbant surface. Partitions in these areas shall be constructed with cement board or moisture resistant gypsum board in lieu of gypsum wall board and/or finished with an epoxy paint. Toilet room accessories (grab bars, toilet paper dispensers, etc.) in these areas shall be installed and sealed to prevent moisture penetration. N. Provide he backer board at locations to receive wall file. Refer to the Finish Plan sheet A204 for locations, P. Contractor shall verify the size and location of all required mechanical pads and wall openings. O. All walls shall be type "Mi unless otherwise noted. R. ADD ALL NO.I: New plastic laminate casework. Upper and lower cabinet with 25"D plastic laminate counnertop. Countertop to include 4"H plastic laminate back and side splash. Upper cabinets to include two height adjustable shelves and white melamine interior. Base cabinets to include a 6"H drawer and double doors with a height adjustable shelf and a white melamine interior. Two duplex and one phone/data outlets installed above the countertop. S. ADD ALT. NO.3: Provide pocket door at Door 203. Reuse existing door panel if possible. BASE BID: typical swing hinge on Door 203, swing into room 202 against wall. T. ADD ALT, NOA: Provide water line, drain pipe and dad ictoed power for dishwasher hook-up. Dishwasher and dishwasher cabinet to be provided and installed by the tenant. U. ADD ALT. NO.5: Install new vertical blinds to match existing in rooms 201 and 217. BASE BID: Remove existing vertical blinds and salvage for reuse. Retrofit existing blinds and hardware to accomodate new rooms 201 and 217. DEDUCT ALL: Remove vertical blinds completey, patch and repair bulkhead to like new condition. Confirm with tenant prior to any work. PLAN LEGEND Existing Shell of Building Structure Existing Partition to Wee Remain 2=21/2"Stud Sae 3=3 5/8" Stud Sae New Partition-Non-Insulated6=6'Stud Sae New Partition Insulated (See Standard Top of Wall Condition Details) Demising Partition G=Gnd Coordinate level of finish outside GI=Gnd / Insulation Tenant space with Owner +6=+6 Above God D=Framed to Deck Above New Fire Rated Partition, R=Fire Rated OI Hour Fire Rated Construction Key Note aaaaccal New Fire Rated Partition, 2 Hour Fire Rated Indicates area not in contract. Referto floor plans for additional information. 101 Door -Refer to Door Schedule O KEYED NOTES - CONSTRUCTION Cl Fur out column to smallest dimension possible on all sides. Prep drywall for new paint C2 Existing door to receive new hardware to allow for door to be permanently bolt locked. C3 ADD AIL No.l -See general notes this sheet for more information. C4 ADD ALT. NoA-See general notes this sheet for more infornation. C5 Provide U shaped brake metal to finish wall to glass, satin aluminum finish. See detail 4/AOOI for more information. C6 ADD ALT. No.5-see general notes this sheet for more information. .3 ;ARSON DESIGN ASSOCIATES MIDWEST 9229 Delegates Row Suite 250 Indianapolis, IN 46240 Tel 317.843.5979 Fax 317.843.5975 SOUTHWEST 12301 Research Blvd Bldg IV- Suite 130 Austin, TX 78759 Tel 5129770520 Fax 512.977.0384 orsondeslgn.com Z ^, W i C 0 Q w NamA,, G W N � 0 W s =N N o } }U} N 00 /ia y/ (D W �C co CD O C7 STAMP: ``xOxvtvM\CH ur4ip �( °7jvpi STE 9 v F —' DIA pxixgRUHii E `0`xp 06.07.19 ISSUE: Permit Set 06.07.19 DRAWING TITLE: Construction Floor Plan JOB NO. 11827705 DATE: 06.07.19 SHEET NUMBER: A211 CGPYRIGM20I5 (We ON DESIGN AoOGATES