HomeMy WebLinkAboutA-100-BASEMENT-FLOOR-DEMOLITION-PLAN-Rev.0EXST. WALL
1'-0"
SEE DOOR SCHEDULE 1'-0' EXST.WALL
NEW WALL
NEW WALL
PROVIDE DRYWALL ON
EACH SIDE OF NEW
... ....
_.,.., .....
...
..
DOOR&FRAME
... ..._
PROVIDE FLUSH
TRANSITION BETWEEN
NEW & EXISTING
WALLS)
NEW STUDS AND INSULATION
SKIM COAT
EXISTING WALL(S)
NEW DOOR INFILL
1'-0"
SEE DOOR SCHEDULE 1'-0"
EXISTING WALL TO
DEMOWALL
DEMOWALL
REMAIN PROTECT
DURING
__r�1
r•�_________
CONSTRUCTION
L �)
SEE DOOR SCHEDULEF. 1'-0"
'I 'I EXISTING WALL TO
REMAIN PROTECT
DURING
____________________ CONSTRUCTION
F I
EXISTING WALL DEMO FOR NEW DOOR
NOTE: DETAILS APPLY FOR NEW WELDED DOOR FRAMES ONLY
ODOOR DEMOLITION DETAIL
4 111 1/21. _ 11-01.
FLOORING CONTRACTOR TO
PROVIDE LATEX FLOOR COMPOUND
OVER TRENCH CUT AREA AS
REQUIRED FOR A SMOOTH FINISH.
#4 REBAR 9" EACH WAY
AT 24" O.C. ALONG
LENGTH OF TRENCH
CUTS.
NEW CONCRETE FLOOR SLAB WITH
6X6 W2.9XW2.9 W W F. INSTALL VAPOR
BARRIER BELOW NEW CONCRETE SLAB
NEW CONCRETE FLOOR PATCHING TO BE
FLUSH WITH SURROUNDING EXISTING
FINISHES.
SAW CUT JOINT AT
CONCRETE REMOVAL
LOCATIONS TYPICAL
, OF EACH SIDE.
WIDTH OF TRENCH TO BE = = = = =1 31FVNNN�
COMPACT FILL DIRT
DETERMINED BV CONTRACTOR ---AND/ORGRAVELAT
BASED ON DEPTH OF WORK -1 =1 =1 =1 =1 =11 EXCAVATION AREA
REQUIRED FORUNDERGROUND UTILITYTIE-IN.
O
EXISTING SLAB INFILL DTL 1" =1,_0„
I
42. 4�/
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations - FLOOR DEMOLITION PLAN
of State and Local Codes
City of Camel (}
�VTI�\aMLdL1al0LL
DATE: 09/04/19
NEW STUD PARTITION
W/ 518" TVPE'X GYP
BOARD EACH SIDE
REMOVE SECTION OF
WALL AND INSTALL
NEW VERTICAL STUDS
FULL HEIGHT
EXISTING DRYWALL
AND METAL STUD
WALL REMOVAL
EXISTING STUD WALL
TO REMAIN
TRENCH SECTION OF
EXISTING DRYWALL FOR
INSTALL OF NEW MECH/ ELEC/
PLUMBING INFRASTRUCTURE.
SEE MEP DRAWINGS FOR
MORE INFO
EXISTING STUD WALL
TO REMAIN
INSTALL NEW DRYWALL FLUSH WITH
EXISTING - TAPE, MUD, AND SAND
SMOOTH
NEW STUDS EACH SIDE
FULL HEIGHT
EXISTING STUDS
TO REMAIN
ONE OR TWO LAYERS OF
DRYWALL DEPENDING ON
FIRE RATING OF WALL. SEE
LIFE SAFETY/CODE
REVIEW PLANS
OSTING FIRE -RATED WALL
PATCH DRYWALL W1518"
TYPE "X" GYP BOARD
FULL HEIGHT OF WALL
REMOVAL
NEW STUDS EACH
SIDE FULL HEIGHT
INFILL Wl NEW
BATT INSULATION
EXISTING DRYWALL REMOVAL EXISTING PARTITIC
O DEMO
FRAMING DTL.
FILL OPENING WITH CONCRETE:
NOTE:
INSTALL TAP -CON ANCHORS
PROTECT CEILING TILE AND
INSIDE OF HOLE OR EPDXY#3
OCCUPIED SPACE BELOW
DOWELS IN SIDE OF OPENING
FLOOR INFILL FROM WATER
DAMAGE WHEN PLACING
CONCRETE.
GALVANIZED SHEET STEEL
ANCHORED TO THE BOTTOM
OFDECK
HOLES UP TO 6" DIA
FILL OPENING WITH
NOTE:
CONCRETE: INSTALL TAP -CON
PROTECT CEILING TILE AND
ANCHORS INSIDE OF HOLE OR
OCCUPIED SPACE BELOW
EPDXY#3 DOWELS IN SIDE OF
FLOOR INFILL FROM WATER
OPENING. SPACE DOWELS AT
DAMAGE WHEN PLACING
5" O.C. MAX.
CONCRETE.
114" PLATE STEEL. EPDXY
ANCHOR TO BOTTOM OF
DECK WITH 4 EPDXY
ANCHORS.
HOLES OVER 6" DIA.
o DECK INFILL DTL
-PATCH DRYWALL W/518"
TYPE "X' GYP BOARD FULL
HEIGHT OF WALL
REMOVAL
NEW STUDS EACH
SIDE FULL HEIGHT
INFILL W/ NEW BATT
J
H
RENOVATION GRAPHIC LEGEND
DEMOLITION GENERAL NOTES
THIS DEMOLITION PLAN SHALL SERVE TO AID THE CONTRACTORS IN
E
EVALUATION OF THE WORK AND EXTENT OF DEMOLITION. BUT WILL NOT BE
EXISTING DOOR TO REMAIN
HELD TO BE ALL INCLUSIVE. THE CONTRACTORS ARE RESPONSIBLE FOR
FIELD VERIFICATION OF EXISTING CONDITIONS, DEMOLITION AND REMOVALS
AS REQUIRED FOR THE INSTALLATION OF THE NEW WORK AND FINISHES
INDICATED WHETHER OR NOT IT IS SPECIFICALLY NOTED IN THESE
DRAWINGS
EXISTING DOOR TO BE REMOVED
B. REFER TO MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS FOR
RELATED WORK. GENERAL CONTRACTOR IS RESPONSIBLE FOR
COORDINATING THE WORK WITH OTHER CONTRACTORS.
1000 NEW DOOR
C. DEMOLITION WORK EFFECTING OCCUPIED AREAS OF THE FACILITY WILL
BE SCHEDULED IN ADVANCE WITH THE OWNER THROUGH
CONSTRUCTION/PROJECT MANAGER. REFER TO SPECIFICATIONS.
EXISTING WINDOW TO REMAIN
D. OFFER REMOVED ITEMS SUCH AS DOORS, HARDWARE, PLUMBING
FIXTURES, AND TOILET ACCESSORIES TO OWNER BEFORE REMOVAL FROM
THE SITE. DETERMINE SALVAGE ITEMS WITH THE OWNER BEFORE
EE E EC EXISTING WINDOW TO BE REMOVED
DEMOLITION BEGINS.
E. ALL CONTRACTORS ARE RESPONSIBLE FOR SECURING CHASES AND
O
RISERS BEFORE DEMOLITION WORK PROCEEDS TO PREVENT DEBRIS FROM
NEWWINDOW
FALLING THROUGH INTO OCCUPIED SPACES BELOW.
F. REFER TO MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS FOR
RELATED WORK AND ITEMS TO BE REMOVED OR RE -INSTALLED IN NEW
CONSTRUCTION. TEMPORARY LIGHTING, COMMUNICATION AND
MECHANICAL SYSTEMS WILL BE COORDINATED WITH OTHER
CONTRACTORS. MAINTAIN ALL LIFE SAFETY DEVISES.
G. HOLES LEFT IN THE CONCRETE FLOOR FROM REMOVED ITEMS SUCH AS
PLUMBING PIPES, CONDUITS, ETC. WILL BE PATCHED BY RESPECTIVE
CONTRACTOR PERFORMING THAT PORTION OF THE WORK.
H. FINISH REMOVAL NOTES APPLY TO PARTITIONS/WALLS THAT REMAIN.
REMOVE ALL FINISHES FROM WALLS THAT REMAIN WITHIN THE LIMIT OF
CONSTRUCTION.
L INTERIOR PARTITIONS AND/OR WALLS SHALL BE REMOVED ENTIRELY
FROM DECK ABOVE TO DECK BELOW.
WORK LIMIT LINE
s
-
I I
I \
1
1.02 2.01
3.01
I
.n
FIRE REF REF I
ENERAL NOTE: ALL DRUG PRODUCTS SHALL BE
REMOVED BY OWNER PRIOR TO ANY COMMENCEMENT
OF WORK PHASE. ANY SHELVING FOR CONTRACTOR `
REMOVAL WILL BE EMPTY �
II
3.03
II 2.04 3.02
/ r
Q
811 I I
3.06 NEW -�11 EXISTING FLOOR
.022.02
I I I \ /� r jll FLOOR ��
-_- I I I IN 3.123.11 III 3.17 - I
r I II I �I r 1
3.07 3.07 3.02
I � I loll o f S.o7 1 III I I I
I el I I I of I II
I I3.05 I �I I3.09 �❑
I N I 2.03 111 I REF REF
F 3A8 � 4: Mir I I
I I l 1 3.14 t
�� l3ns 1.022.01 -�
3.01 D
F-- QQg 1.012.01 F 3.01
:i i- 1.012.01 l l 3.14 3.08 1.022.02
l �Iltlr I I S.01 l a.1s ll
I -�
�I
III I I 13.1s I L IF ---------------------------
3.07 3.07 I I o l
I II I l
L T\ - L-- 3._.._yL- t�_ST\17NG
ucR 3.04
--------�l 1.022.023.o6 J l 1.022.01.093.012.01 REMOVECEILING3.18
F - 1.01 .01 MODIFYI - T - - - - CEILING318 �3.04ILLLLL-TL L - 1 JNEWOR
II FLOOR 3.02
3.04 1.02 2.02
L J
B.6 - -----T---T--- r - - - -
---- 3.09 �
--1---J 3.04 1 3.15 3.15
1-- j
1 3.G8 l 1 3.08
----7
-3.09 T--- 1 ---
---- - --- 3.09 -
---
1---1----J p WORK LIMIT
IN
I
1.02 2.01 3.04 1
3.01 1
1 IN
I 1
a.20 IN
r--Ir -Ir-�r- -IF - r
I II II II II 1 I I :
I II II II II I
I II II II II I
I II 3.09
I I II II II I I I �
L_J _JL_JL-JL_1 L-
1
42.6 42 41.51 41
BASEMENT DEMOLITION PLAN
1 /4" = 1'-0"
NORTH
1,64
-N
.55.M7
m
DEMOLITION PLAN NOTES
MECHANICAL AND PLUMBING CHASES
A CHASFJRISER TO REMAIN - REMOVE PORTION OF WALL AS REQUIRED TO
EXPOSE DUCTWORK. CONTRACTOR TO SECURE CHASE OPENING
THROUGH FLOOR TO PREVENT DEBRIS FROM FALLING THROUGH TO
OCCUPIED SPACES BELOW. SEE MECHANICAL FOR MORE INFORMATION.
CEILING DEMOLITION
1.01 REMOVE AND DISPOSE OF ACOUSTICAL LAY -IN CEILING SYSTEM:
TILES,GRID AND ALL RELATED HANGERS AND SUPPORTS.
1.02 EXISTING ACOUSTICAL LAY -IN CEILING SYSTEM TO REMAIN. PROTECT
DURING CONSTRUCTION. MODIFY AS REQUIRED TO ACCEPT NEW WORK.
REPLACE DAMAGED CEILING AREAS (MATCH EXISTING) AT CONCLUSION
OF THE WORK.
FLOORING DEMOLITION
2.01 REMOVE AND DISPOSE OF VINYL FLOORING(SHEETIVCT) AND ALL
RELATED MASTIC/ADHESIVE. CLEAN/PREP/PATCH/ REPAIR SUBFLOOR
TO ACCEPT NEW FLOORING AS SCHEDULED. SUBFLOOR NEEDS TO BE
COMPLETELY LEVEL AND SMOOTH PRIOR TO INSTALLATION OF NEW
FINISHES AS SCHEDULED.
2.02 EXISTING FLOOR FINISH TO REMAIN. PROTECT FLOORING DURING
CONSTRUCTION. REPLACE DAMAGED FLOOR AREAS (MATCH EXISTING)
AT CONSLUSION OF THE WORK.
2.03 REMOVE PORTIONS OF EXISTING CONCRETE FLOOR SLAB AS REQUIRED
FOR THE PLUMBING SCOPE OF WORK IN SHADED AREA. SEE PLUMBING
FOR MORE INFORMATION.
2.04 REMOVE FLOOR ANCHORS FROM PREVIOUS DOOR HARDWARE. PATCH
/REPAIR FLOOR AS REQUIRED TO ACCEPT NEW FINISHES AS SCHEDULED.
SEE PLUMBING FOR MORE INFORMATION.
PARTITION DEMOLITION
3.01 REPAIR ALL DISPOSE T EXISTING WALL BASE. CLEAN/PREP/PATCH/
REPAIR WALL SURFACE TO ACCEPT NEW FINISHES AS SCHEDULED.
3.02 REMOVE AND DISPOSE OF EXISTING WALL BASE FROM CORNER TO
CORNER. CLEAN/ PREP/ PATCH/ REPAIR WALL SURFACE TO ACCEPT NEW
FINISHES AS SCHEDULED.
3.03 REMOVE AND DISPOSE OF EXISTING EMERGENCY EYE WASH STATION IN
ITS ENTIRETY. OFFER TO OWNER BEFORE DISPOSING. CLEAN/PREP/
PATCH/ REPAIR WALL SURFACE TO ACCEPT NEW FINISHES AS
SCHEDULED.
3.04 CORNER GUARD, RUBSTRIP TO REMAIN. PROTECT DURING
CONSTRUCTION. REMOVE COVERS WHILE PAINTING.
3.05 REMOVE AND DISPOSE OF INTERIOR WINDOW SYSTEM.
3.W REMOVE DOOR(S), HARDWARE, AND FRAME. OFFER DOOR(S)AND
HARDWARE TO OWNER BEFORE DISPOSING. CLEAN/PREP/PATCH/
REPAIR WALL SURFACE TO ACCEPT NEW WORK AS SCHEDULED.
3.07 REMOVE/ DISMANTLE SYSTEMS FURNITURE BASE CABINET(S),
COUNTERTOP, WALL CABINET(SE AND MISCELLANEOUS TASKLIGHTING.
OFFER TO OWNER BEFORE DISPOSING. CLEAN/PREP/PATCH/REPAIR
WALL SURFACE TO ACCEPT NEW FINISHES AS SCHEDULED.
3.08 EXISTING BASE CABINET(S), COUNTERTOP, WALL CABINET(S), AND
MISCELLANEOUS TASKLIGHTING TO REMAIN. PROTECT DURING
CONSTRUCTION. REPAIR/REPLACE DAMAGED COMPONENTS AT
CONCLUSION OF THE WORK.
3.09 EXISTING SHELVES TO BE REMOVED/ RELOCATED BY OWNER/
OFFICEWORKS.
3.10 EXISTING EQUIPMENT TO REMAIN. TEMPORARILY RELOCATE AS
REQUIRED FOR INSTALLATION OF NEW FINISHES.
3.11 REMOVE ALL EXISTING TOILET ACCESSORIES. OFFERTOOWNER
BEFORE DISPOSING.
3.12 REMOVE PLUMBING FITURE(S). OFFER TO OWNER BEFORE DISPOSING.
SEE PLUMBING DRAWINGS FOR MORE INFORMATION.
3.13 EXISTING PLUMBING FIXTURES) TO REMAIN. PROTECT DURING
CONSTRUCTION. REPLACE DAMAGED COMPONENTS AT CONCLUSION OF
THE WORK.
3.14 EXISTING EQUIPMENT TO BE REMOVED BY OFFICEWORKS/OWNER PRIOR
TO THE START OF CONSTRUCTION.
3.15 REMOVE AND DISPOSE OF EXISTING REFRIGERATOR. OFFER TO OWNER
BEFORE DISPOSING. REFRIDGERATORS IN MAIN PHARMACY ARE NOT TO
BE REMOVED UNTIL REPLACEMENTS ARE READYTO INSTALL. OWNER TO
REMOVE ALL PRODUCT CONTENTS PRIOR TO REMOVAL.
3.16 REMOVE EXISTING HOOD. COORDINATE AND CONFIRM WITH OWNER IF
HOOD IS TO BE STORED FOR REINSTALLATION IN NEW WORK OR
DISMANTLED AND DISPOSED OF.
3.17 REMOVE EXISTING NOTICE BOARD IN ITS COMPONENTS. OFFER TO
OWNER PRIOR TO DISPOSING.
3.18 RELOCATE OR REMOVE EXISTING PYXIS UNIT TO TEMPORARY LOCATION.
COORDINATE WITH OWNER LOCATION AND NEED FOR TEMPORARY
POWER AND/OR DATA
3.19 REMOVE FULL -HEIGHT PASS -THROUGH CART CABINET. OFFER TO OWNER
PRIOR TO DISPOSING. PREP FLOOR AS REQUIRED FOR NEW FINISH AFTER
REMOVAL.
320 REMOVE TOP RAILS AN D ALL COMPON ENTS FOR MOBILE WIRE SHELVING
UNITS. OFFER RAILS AND COMPONENTS TO OWNER PRIOR TO DISPOSING.
SALVAGE AND RETURN WIRE RACKS TO OWNER.
91
MKM
architecture + design
119 West Wayne Street
FW Wayne, Indiana 46802
IS 260.422.0783
f MOA2&4%1
www.MKMdesian.cum
i 1a. AttIf200EB1
MW
�'MpAN�
-`vlilic�
COmsul4�nLLOg¢ "
NY FIAT
IxgcniED DESIGNS
Y THIS PRAWINS ARE OWNED BY, AND
THE PROPERTY OF MKM ARCHITECTURE ♦ DESIGN,
PNO WERE CREATED AND DEVELOPED FOR USE ON
AMID IN CONNECTION WTH THIS SPECIFIC PROJECT
HONE OF THE IDEAS, DESIGNS. ARRANGEMENTS OR
PLANE SHALL BE USED BY OR DISCLOSED TO ANY
SORM OR CORPORATION FOR ANY
PURPOSE
FIRM ANATSOFOR? SYTHOUT THE WHITNEY
PERMISSION OF MKM ARCHITECTURE • C N.
THE OMER SHALL BE PERM17ED TO RETAIN
WINES FOR INFORMATION AND REFERENCE IN
CONNECTION NTH THIS PROJECT WTmm
DIMENSIONS ON THESE DRMMNGS SHALL HAVE
PRECEDENCE OVER SCALE DIMENSIONS.
CONTRAC ORS SHALL V ERIFTPND SE RESPONSIBLE
FOR NL DIMENSIONS AND CONDITIONS ON THE JOB
AMID THIS OFFICE MOST BE NOTIFIED OF ANY
VARIATIONFRONITHEDIMENSIONSANDCOMETTIONS
SHOWN BY THESE DRAMINGS. SHOP DRALNNICS
MOST BE SUBMITTED TO THIS OFFICE FOR RENEW
BEFORE niCCE£dNG WITH FABRICATION ANDOR
INSTALLATION. THE WORK SHOWN ON THIS
DOCUMENT, AND THE CORRESPONDING
SPECIFILATOHB, INTERFACES WIN WORK SHOWN
ON OTHER DOCUMENTS INCLUDING MRS TO BE
PERFORMED BY OTHER CONTRACTORS OR
SUBCONTRACTORS. EACH CONTRACTOR OR
SUBCONTRACTOR SHALL BE FAMILIAR WIN THE
WORK OF OTHER CONTRACTORS OR
SUBCONTRACTORS, WHETHER OR NOT SHGNN ON
TI$ DOLVMEMT WH LX MPPCT$ THE WORX
DOMINATE
THE WORK SHOWN ED AS ANO SHF N
COORDINATE SUCH WORN 50 UL i0 OJ IN
DOCUMENTS.
D]LLMENiS.
St. Vincent
Carmel Hospital
Carmel Pharmacy 797 800
13500 N Meridian Street
IV. 40U,
MIS"
DRAWRNG CONTENTS:
BASEMENT FLOOR
DEMOLITION PLAN
ISSUE DATE'. PROJECT NO.
04/26/2019 MKM'. 17107
ASCENSION W286
DRAWING NO.
A-100