Loading...
HomeMy WebLinkAboutA-110-BASEMENT-FLOOR-DIMENSION-AND-NOTATION-PLAN-Rev.0FIRST FLOOR NOTATION PLAN 1/4" = 1'-ON NORTH C I C mi.r.p u run 6illinuLpnun Subject to compliance with all regulations of State and Local Codes City of Cannel (} �VTI�\aM1c)L1al0LL NT DIMENSION FLOOR PLAN C I C NOTE: WALL PARTITION DIMENSION STRINGS ARE FROM FACE OF STUD TO FACE OF STUD. STRINGS FROM EXISTING WALLS ARE FROM FINISH. TYPICAL FRAMING DTL. BASEMENT NOTATION FLOOR PLAN 1/4" = 1'-0" 1.0 METALSTUD 2.0 WOODSTUD 3.0 ® CONCRETE MASONRY UNIT d.0 0 CAST -IN -PLACE CONCRETE STRUCTURE/FRAMING STRUCTURE/FRAMING NOMINAL DIMENSION 1.3a TYPE DESIGNATION Q-�- ERATING WALL TYPE LEGEND FLOOR PLAN GENERAL NOTES A. THE WORK SHOWN ON THESE DOCUMENTS AND THE CORRESPONDING SPECIFICATIONS, INTERFACES WITH OTHER TRADES, WHETHER OR NOT SHOWN ON THESE DOCUMENTS, WHICH IMPACTS THE WORK SHOWN HEREIN. IT IS THE GENERAL CONTRACTOR'S RESPONSIBILITY TO COORDINATE SUCH WORK SO AS TO BE IN COMPLIANCE WITH THE INTENT OF ALL THE PROJECT DOCUMENTS. B. GENERAL CONTRACTOR TO PROVIDE SOLID BLOCKING FOR ALL WALL MOUNTED CASEWORK, EQUIPMENT, AND ACCESSORIES, INCLUDING TOILET ACCESSORIES AS REQUIRED. C. REFER TO CODE REVIEW PLAN FOR RATED PARTITIONS AND ASSEMBLIES. SEE TYPICAL DETAIL SHEETS FOR FRAMING INFORMATION RELATED TO INTERSECTING SYSTEMS AND INSTALLATION CONDITIONS. D. GENERAL CONTRACTOR TO PATCH ALL CONCRETE SLABS / DECKS AT MECHANICAL, ELECTRICAL AND/OR PLUMBING PENETRATIONS. PER TYPICAL IN -FILL DETAIL LOCATED ON DEMOLITION SHEET. PATCH TO FLUSH WITH EXISTING SLAB/DECK. E. DAMAGED WALLS AND FINISHES TO BE REPAIRED AS REQUIRED TO MATCH EXISTING ADJACENT WALLS. F. GENERAL CONTRACTOR SHALL BE RESPONSIBLE TO PATCH ALL CRACKS AND RESEAL JOINTS IN EXISTING SUBSTRATES SCHEDULED TO RECEIVE NEW FINISHES. G. UNLESS NOTED OTHERWISE, NEW WALLS TO BE 35/8" METAL STUDS @ 16" O.C. WITH (1) LAYER OF 5/8" TYPE "X" GYPSUM BOARD EACH SIDE. EXTEND STUD AND GYPSUM BOARD TO DECK ABOVE. INSULATE FULL HEIGHT. SEAL AS REQUIRED FOR WALL RATINGS INDICATED ON THE CODE REVIEW PLAN. W INSTALL CONTROL/EXPANSION JOINTS PER TYPICAL DETAILS UNLESS NOTED OTHERWISE. FREQUENCY SHOULD MATCH INDUSTRY STANDARD AS NOTED ON DETAILS. I. DO NOT SCALE DRAWINGS. IF DIMENSIONS ARE IN QUESTION THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING CLARIFICATION FROM THE ARCHITECT BEFORE CONTINUING CONSTRUCTION. FOR FURTHER DIMENSIONING SEE ENLARGED PLANS, SECTIONS, AND ELEVATIONS. CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS ON THE JOB AND THE ARCHITECT MUST BE NOTIFIED OF ANY VARIATION FROM THE DIMENSIONS AND CONDITIONS SHOWN BY THESE DRAWINGS. SHOP DRAWINGS MUST BE SUBMITTED TO THE ARCHITECT FOR REVIEW BEFORE PROCEEDING WITH FABRICATION AND/OR INSTALLATION. J. WALL DIMENSIONS ARE FROM FACE -OF -STUD TO FACE -OF -STUD OR EXISTING FINISH TO FACE -OF - STUD. SEE TYPICAL DETAIL FOR MORE INFORMATION. K. THE CONTRACTOR SHALL CAREFULLY STUDY AND COMPARE THE REFLECTED CEILING PLAN WITH THE LIGHTING PLANS AND MECHANICAL SUPPLY, RETURN AND EXHAUST PLANS. REPORT IN WRITING TO THE ARCHITECT ANY INCONSISTENCY HEREIN. L. THE CONTRACTOR SHALL VERIFY AND PROVIDE ACCESS PANELS IN WALLS AND CEILINGS WHERE SERVICE AND ADJUSTMENTS TO MECHANICAL, PLUMBING, OR ELECTRICAL MAY BE REQUIRED. ACCESS PANELS SHALL BE THE FIRE RATED TYPE EQUAL TO THE WALL OR CEILING IN WHICH THEY OCCUR AND FINAL LOCATION SHOULD BE VERIFIED WITH ARCHITECT PRIOR TO INSTALLATION. SEE SPECIFICATIONS FOR ADDITIONAL INFORMATION. M. PIPING INSIDE THE BUILDING SHALL BE CONCEALED IN FURRED SPACES WITH THE EXCEPTION OF PIPING IN MECHANICAL AND SERVICE ROOMS. CHASES SHALL BE PROVIDED FOR ALL MECHANICAL, ELECTRICAL, AND PLUMBING AS REQUIRED. SEE RESPECTIVE PLAN & ELEVATION DRAWINGS FOR COORDINATION. W SEE ELECTRICAL DRAWINGS AND/OR COMMUNICATIONS DRAWINGS FOR LOCATIONS OF CEILING MOUNTED SMOKE DETECTORS, SPEAKERS, NURSE CALL SYSTEMS, FIRE ALARM DEVICES, EXIT SIGNAGE, ETC. IT IS THE CONTRACTOR'S RESPONSIBILITY TO COORDINATE THESE ITEMS WITH THE REFLECTED CEILING PLANS) O. SEE FINISH SCHEDULE, PLANS, & ELEVATIONS FOR LOCATIONS OF SPECIFIC FINISHES, MATERIALS, AND ACCENT WALL$ P. THE INSTALLATION OF ALL PLUMBING FIXTURES SHALL CONFORM TO THE REQUIREMENTS OF THE MOST CURRENT EDITION OF THE ANSI ACCESSIBILITY CODE AND THE AMERICANS WITH DISABILITIES ACT, WHICHEVER IS MORE STRINGENT. FLOOR PLAN NOTES DIV 3-CONCRETE 3.01 SHADED HATCH INDCATES LOCATION TO PATCH CONCRETE AS REQUIRED FOR NEW PLUMBING SCOPE OF WORK. SEE PLUMBING FOR MORE INFORMATION. DIV 6- WOOD, PLASTICS, AND COMPOSITES 6.01 PROVIDE WALL BLOCKING AS REQUIRED FOR INSTALLATION OF SYSTEM FURNITURE AND CABINENTS. CONTRACTOR TO COORDINATE WITH FURNITURE VENDOR FOR BLOCKING REQUIREMENTS AT EACH LOCATION. ON 7 - THERMAL AND MOISTURE PROTECTION 7.01 CONTRACTOR TO APPLY MOISTURE BARRIER TOP SEALANT TO ALL EXPOSED CONCRETE SUBFLOOR INCLUDING IN -FILLED PATCHED AREAS PRIOR TO INSTALLING NEW FINISH FLOOR MATERIAL. PRODUCT BASIS OF DESIGN: ARDEX MOISTURE CONTROL, CONFIRM MANUFACTURER PREFERENCE WITH MEDXCEL FM. SEE FINISH PLAN FOR MORE INFORMATION. DIV 8 - OPENINGS 8.01 PROVIDE NEW DOOR SYSTEM. SEE DOOR SCHEDULE FOR MORE INFORMATION. DIV 9 - FINISHES 9.01 ALL DRYWALL INSIDE CORNERS AT WALL-TO-WALL AND WALL -TO -CEILING JOINTS TO BE INSTALLED WITH 3/8" RADIUSED CORNER BEAD. SEE TYPICAL DETAIL ON FINISH SHEET. 9.02 SHADED AREA INDICATES AREA FOR NEW FLOOR/INFILL. PROVIDE MOISTURE BARRIER TOP COAT TO EXPOSED SLAB PRIOR TO INSTALLING FLOOR PRODUCT. SEE FINISH PLAN FOR MORE INFORMATION. 9.03 INFILL WALL AS REQUIRED AS RESULT OF MECHANICAL SCOPE OF WORK. INFILL WALL CONSTRUCTION TO MATCH ADJACENT WALL ASSEMBLY AND RATINGS. SEE MECHANICAL FOR MORE INFORMATION. 9.04 EXISTING CORNER GUARD, OR BUMPER RAIL TO REMAIN. REMOVE COVERS WHILE PAINTING WALLS. DIV 10-SPECIALTIES 10.01 OWNER TO PROVIDE HAND SOAP AND TOWEL DISPENSER, INSTALLED BY CONTRACTOR. PROVIDE BLOCKING AS REQUIRED. DIV 11 - EQUIPMENT 11.01 CONTRACTOR TO PROVIDE NEW PHARMACY GRADE REFRIGERATOR. HELMER MANUFACTURER. MODEL iPR105-GX 5.3 CU.FT 11.02 CONTRACTOR TO PROVIDE NEW PHARMACY GRADE FREEZER. FOLLETT MANUFACTURER. MODEL FZR2 1.6 CU.FT. COORDINATE WITH OFFICEWORKS SYSTEM FURNITURE. 11.03 CONTRACTOR TO REINSTALL SALVAGED HOOD. IT IS THE CONTRACTORS RESPONSIBILITY TO RECERTIFY HOOD AT COMPLETION OF INSTALL. 11.04 CONTRACTOR TO PROVIDE NEW 4'-0" PHARMACY HOOD, NUAIRE NU-%0-400. COORDINATE VENDOR, MAKE AND MODEL WITH OWNER PRIOR TO PURCHASE. COORDINATE MECHANICAL AND ELECTRICAL REQUIREMENTS. SEE MEP FOR MORE INFORMATION. IT IS CONTRACTOR'S RESPONSIBILITY FOR CERTIFICATION AT COMPLETION OF INSTALL 11,05 CONTRACTOR TO PROVIDE NEW 4'-0" PHARMACY HOOD, NUAIRE NU-813-400. COORDINATE VENDOR, MAKE AND MODEL WITH OWNER PRIOR TO PURCHASE. COORDINATE MECHANICAL AND ELECTRICAL REQUIREMENTS. SEE MEP FOR MORE INFORMATION. IT IS CONTRACTOR'S RESPONSIBILITY FOR CERTIFICATION AT COMPLETION OF INSTALL 11.06 CONTRACTOR TO PROVIDE NEW 36" INTERLOCKING PHARMACY PASS-THRU WITH INTERIOR REMOVABLE STAINLESS STEEL SHELF. PRODUCT BY CLEAN AIR PRODUCTS BASIS OF DESIGN MODEL NUMBER CAPI8WFB-SST-36WX36HX36D. SEE TYPICAL DETAILS 500 SERIES SHEETS FOR MORE INFORMATION INCLUDING SPECIFIC ACCESSORIES REQUIRED BASED ON INSTALLATION. 11.07 CONTRACTOR TO PROVIDE NEW FIRE RATED 24" INTERLOCKING PHARMACY PASS-THRU WITH INTERIOR REMOVABLE STAINLESS STEEL SHELF. PRODUCT BY CLEAN AIR PRODUCTS BASIS OF DESIGN MODEL NUMBER CAPI8WFB-SST-24WX24HX24D. SEE TYPICAL DETAILS 500 SERIES SHEETS FOR MORE INFORMATION INCLUDING SPECIFIC ACCESSORIES REQUIRED BASED ON INSTALLATION. DIV 12. FURNISHINGS 12.01 COUNTERTOP/ WORKSTATION AND WALL STORAGE BY OFFICE WORKS. COORDINATE ANY POWER AND DATA REQUIREMENTS. PROVIDE INWALL BLOCKING AS REQUIRED FOR INSTALLATION OF COUNTERS AND WALL MOUNTED SHELVES 12.02 BENCH/ GOWNING SUPPLIES STORAGE BY OFFICEWORKS 12.03 SHELF ABOVE SINK BY OFFICEWORKS. CONTRACTOR TO PROVIDE BLOCKING AS REQUIRED. CONTRACTOR TO COORDINATE WITH OFFICEWORKS. DIV 22 - PLUMBING 22.01 NEW SINK. SEE PLUMBING FOR MORE INFORMATION. DIV 23 - HEATING, VENTILATION, AND AIR CONDITIONING 23.01 NEW RETURN CHASE. SEE MECHANICAL FOR MORE INFORMATION. DIV 26 - ELECTRICAL 26.01 NEW CEILING MOUNTED DATA/ POWER. SEE ELECTRICAL FOR MORE INFORMATION. W.1III MM1»39J4ell] 4= WALL TYPE RATING DESCRIPTION 1.3 35/T METAL STUD @16"O.C.(1) LAYER 5/8" TYPE "X"GYPSUM BOARD EACH SIDE EXTEND TO DECK ABOVE AND INSULATE FULL HEIGHT (TYPICAL WALL COMPOSITION). 1.3b 3 5/8" METAL STUD @ 16" O.C. (1) LAYER 5/8" TYPE "X" GYPSUM BOARD EACH SIDE EXTEND TO DECK ABOVE AND INSULATE FULL HEIGHT. 1.3d 1-HR SAME AS 1.3 EXCEPT: WALL IS RATED. FIRESTOP AS REQUIRED. SEE UL DESIGN NO. U419. 11 MKM architecture + design 119 West Wayne Street IEW Wayne, Indiana 46802 p 260.422.0783 f MOA2&4%1 viww.MKMdesian.cum iM AftIf200aB1 87ATE41r Key Plert THE PROPERTY OF MKM ARCHITECTURE ♦ DEEIGN, PHD WERE CREATED AND DEVELOPED FOR USE ON, AMID IN CONNECTION WTH THIS SPECIFIC PROJECT HONE OF THE IDEAS, DESIGNS. ARRANGEMENTS OR PLANS SHALL BE USED BY OR DISCLOSED TO ANY PERSON. M OR CORPORATION FOR ANY PURPOSE WHHATSOEVER LWTHOUT THE FARTHER PERMISSION OF MKM ARCHITECTURE • C N. THE OMER SHOT BE PERM17ED TO RETAIN COPIES FOR INFORMATION AND REFERnICE IN CONNECTION NTH THIS PROJECT MITT EN DIMENSIONS ON THESE DRAMNGS SMILE HAVE PRECEDENCE OVER SCALE DIMENSIONS. AHD THIS OFFCE MUST BE NOTIFIED OF ANY VARIANONRROMTHEDIMENAONSANDCONDITTFONS SHOWN BY THESE DRAMINGS. SHOP DRAINAGE MOST BE yJMIO TO THIS OFFICE FOR REAM BEFORE PROFFEDING WITH FABRICATION ARGON INSTALLATION. THE WORK MOM ON THIS DOCUMENT, AND THE CORRESPONDING SFECIFILATOHB, INTERFACES WIN WORK SHOWN ON OTHER DOCUMENTS INCLUDING VARK TO BE PERFORMED BY OTHER CONTRACTORS OR SUBCONTRACTORS. EACH CONTRACTOR OR SUBCONTRACTOR SHALL BE FAMILIAR WITH THE WORK OF OTHER CONTRACTORS OR SUBCONTRACTORS, WHETHER OR NOT SHOWN ON THIS DOCUMENT WHICH IMPACTS THE WORK IMPACTS THE WORN SHOWN FRESH AND SHALL COORDINATE SUCH WORK SO AS TO EF IN COMPLWICE WTHTHEINTNTOMIJLTHEPROFCT DOCUMENTS. St. Vincent Carmel Hospital Carmel Pharmacy 797 800 13500 N Meridian Street REVISKIN DRAWING CONTENTS: BASEMENT FLOOR DIMENSION AND NOTATION PLAN ISSUE DATE'. PROJECT NO. 04/26/2019 MKM'. 17107 ASCENSIONW286 DATE: 09/04/19 A-110