HomeMy WebLinkAboutA-130-BASEMENT-FLOOR-REFLECTED-CEILING-PLAN-Rev.0RELEASED FOR CONSTRUCTION Subject to compliance with all regulafons at State and Local Codes City of Carmel '6PRN IINI%i C I C BASEMENT REFLECTED CEILING PLAN 1 /4" = 110" NORTH O REFLECTED CEILING PLAN GENERAL NOTES REFLECTED CEILING FINISH LEGEND A CONTRACTOR TO REVIEW REFLECTED CEILING CEILINGS - NO SUBSTITUTIONS SUMMARY PLANS WITH MECHANICAL, ELECTRICAL, PLUMBING, AND APPROVED DISTRIBUTOR: Section includes ceiling tile and accessories. FIRE PROTECTION SYSTEMS TO COORDINATE Name: Medxcel Customer Team INSTALLATION AND NOTIFY ARCHITECT IMMEDIATELY IF Email: Medxcel@Grainger.com DEFINITIONS ANY CONFLICTS OCCUR. Phone Number. 1-888-693-3722 See Room Finish Schedules for application. APPROVED MANUFACTURE: B. FIELD VERIFY ANY ACCESS PANELS WITHIN THE Name: Ceiling Technical Support Team PERFORMANCE CRITERIA PERF I CEILINGS/ SOFFITS WITH ARCHITECT PRIOR TO Phone Number: 717-396 I325 rtl Acoustical In Calling y' mg INSTALLATION. SEE SPECIFICAITONS FOR ACCESS ACP 1 Tile Size: 24" x PANELS. ALI-A NG Square Square Edge Width: Grid Grid PRODUCT TYPE: CALLA PRODUCT h or Vacuum Cleaning: Soft or Vacuum rng: fit Brush SIZE: 24" X 24" X 1" M Resistant to: Sag, Mold, Mildew Sag, COLOR: WHITE Fire Rating: QlassA GRID SYSTEM: PRELUDE I5116' REFLECTED CEILING PLAN NOTES EXPOSED TEE (WHITE) Clean Room Lay -In Ceiling Tile Size: 24" x 24" Edge Style'. Square 1 EXISTING CEILING SYSTEM TO REMAIN. ACP-2 Texture'. Smooth, Non-Peforated, Non -Absorptive CONTRACTOR TO REFER TO MEP DRAWINGS FOR (CLINICAL USE ONLY) Grid Width'. 15/16"Standard Grid ADDITIONAL AREAS THAT MAY REQUIRE TILE MANUFACTURER: ARMSTRONG Cleaning'. Washable/Scrubbable, Withstand REMOVAL FOR ABOVE CEILING WORK. REPLACE PRODUCT TYPE: ULTIMA HEALTH ZONE Cleaning Chemicals ANY DAMAGED OR SOILED TILES AS NEEDED AT SIZE: 24" X 24" X 314" Rest stood to: Sag, Mold, Mildew and Bacterial COMPLETION OF THE WORK. CONTRACTOR TO COLOR: WHITE Growth PROTECT CEILINGS AS REQUIRED DURING GRID SYSTEM: 15/1W CO -EXTRUDED Fire Rating: Class A CONSTRUCTION. CLEAN ROOM (WHITE) 2 MODIFY EXISTING ACOUSTICAL CEILING SYSTEM, PRODUCT APPLICATION GRID AND TILE, AS REQUIRED AS A RESULT OF All grids will be aluminum. DEMOLITION / NEW WALL CONSTRUCTION. GYP Ceiling dies will not be used in areas of high humidity PROVIDE AND INSTALL NEW ACOUSTICAL CEILING COLOR: SEE FINISH LEGEND FINISH: FLAT or wet areas. Use mold resistant gypsum board. SYSTEM, GRID AND TILE, AS REQUIRED THAT (U.N.O.) 2x2 standard acoustical wilingtiles will be utilized MATCHES EXISTING IN FINISH, TEXTURE AND except for special use areas. COLOR. Ceiling gads of 1" nominal width will be utilized 3 PROVIDE 24"X24"GASKETED ACCESS PANEL. ,h CEILING HEIGHT A.F.F. except for special use areas. COORDINATE LOCATION WITH MEPAND OWNER. `T PRODUCT SUBMITTALS 4 POWER AND DATA IN CEILING FOR HOOD AND FUTURE CAMERA SEE ELECTRICAL FOR MORE SPEAKER Productdata, including technical literature for INFORMATION products and systems, is not required. 6 NEW GASKETED CEILING FIXTURES. SEE MEP DELIVERY, STORAGE, AND HANDLING FOR MORE INFORMATION Product will be delivered just -in -time using Grainger 7 PROVIDE GASKETED ACCESS PANEL. procurement process as identified in Ascension COORDINATE WITH MEP AND OWNER FOR Specification Guidance. Do not provide attic stock. LOCATION. CUBICLE CURTAIN & TRACK SUMMARY APPROVED DISTRIBUTOR: Upholstery and Cubicle Curtains PROCUREMENT: GRAINGER CONTACT: PERFORMANCE CRITERIA Name: Medxcel Customer Team Cubicle Curtains Email: Modxcel@Grainger.com Fabric Content 100% Polyester, Opaque, Phone Number 1-888693,3722 Washable, Flame Retardant, and Closely Woven APPROVE MANUFACTURE: Installed Heignt above Floor: Bottom of Curtain: MANUFACTURE: 12-15" AFF INPRO Mesh: Open Weave 100% Nylon PRODUCT CONTACT: Mesh Height 2T at top of curtain Name: Front Jablonski Fire Code: Flame Retardant Passing NFPA 701 Email: Jablonski@inprocc rp.com Cleaning: Washable to 160 degrees Fahrenheit Phone Number: 262679-9010 PRODUCT SUBMITTALS APPROVE MANUFACTURE: Product data, including technical literature for MANUFACTURE: STANDARD TEXTILE products and systems is required. PRODUCT CONTACT: Name: Norman Frankel DELIVERY, STORAGE, AND HANDLING Email: rfrankel@stendamtextile.com Product will be delivered just-irntime using Grainger Phone Number: 513-761-9255 x2265 procurement process as identified in procurement specifcation, 00 0000 /02. APPROVE MANUFACTURE: MANUFACTURE: MEDLINE PRODUCT CONTACT: Name: Amy Regnier Email: aregnier@madline.com Phone Number: 847643-4789 CURTAIN TRACK: CURTAIN MANUFACTURER: INPRO CORP PRODUCT TYPE: ULTRA CUBE CUBICLE CURTAIN CC-1 MANUFACTURER:MAHARAM STYLE: MODERATE 511459 COLOR: 002 VAPOR CC-1 MANUFACTURER:MAHARAM STYLE ', MODERATE 511459 COLOR: 006 PUNCH CC-1 MANUFACTURER:MAHARAM STYLE: MODERATE 511459 COLOR: 005 LAGOON METAL STUD DIAG. / BRACING @ 48" O.C. METALSTUD Q FRAMING @ 16" O.C. LAY -IN CEILING TILE - SEE REF. CLG. PLAN 58" TYPE "X" GYPSUM BOARD CEILING DTL. 1" = r-o" 10" WIRE TIE FOR CEILING / GRID SHALL BE LOCATED WITHIN IT OF THE WALL � CEILING TILE GRID PERIMETER CEILING TRACK — 5/8" TYPE "X" GYPSUM BOARD CEILING DTL. 1"=1'0" LOCATE ALL SMOKE AND FIRE DETECTORS A MINIMUM OF 3-0" FROM ANY SUPPLY DIFFUSER OR RETURN AIR GRILLE CORRIDOR HALLWAY I I I ir 2X4 LIGHT InO. & I SUPPLY/ - --------- RETURN 3'gr GRILLE OSMOKE/FIRE DETECTOR DTL. 2 1/2n =1._0" H H HI I BATT INSULATION. (TYP) I I H METAL STUD FRAMING EITHER SIDE OF CONTROL JOINT. _ "`F 5/8' TYPE "X" GYP. BOARD. (TVP.) METAL DRYWALL CONTROL JOINT MUDDED AND TAPED AS SPECIFIED. FILL CONTROL JOINT WITH APPROVED PRINTABLE SEALANT PAINT CEILING AND SEALANT JOINT AS SCHEDULED. O DRYWALL CTL" JOINT DTL. MKM architecture + design 119 West Wayne Street IEW Wayne, Indiana 46802 p 260.422.0783 f MOA2&4%1 www.MKMdesian.com Ko.AR1f206E01 STATEOF Key Ran THE PROPERTY OF MKM ARCHITECTURE ♦ DEEIGN, PHD WERE CREATED AND DEVELOPED FOR USE ON, AMID IN CONNECTION WTH THIS SPECIFIC PROJECT HONE OF THE IDEAS, DESIGNS. ARRANGEMENTS OR RARE SHALL BE USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORPORATION FOR A PURPOSE WHATSOEVER NY ATSOEVER LWTHOUT THE WRITTEN PERMISSION OF MKM ARCHITECTURE . C N. THE OMER SHALL BE PERM17ED TO RETAIN CORES FOR INFORMATION AND REFERENCE IN CONNECTION NTH THIS PROJECT WTmm DIMENSIONS ON THESE DRMMNGS SMILE HAVE PRECEDENCE OVER SCALE DIMENS'ONS. AND THIS OFRCE MUST BE NOTIFIED OF ANY VARIANONRROMTHEDIMENAONSANDCONDITTFONS BROWN BY THESE DRAwNGS. SHOP DRAVANCS MOST BE yJMIO TO THIS OFFICE FOR REAM BEFORE PROCEEDING WTN FABRICATION ARGON INSTALLATION. THE WORK SHOWN ON THIS DOCUMENT, AND THE CORRESPONDING SFECIricAno S, INTERFACES NITH WORK SHOWN ON OTHER DOCUMENTS INCLUDING WORK TO BE PERFORMED BY OTHER CONTRACTORS OR SUBCONTRACTORS. EACH CONTRACTOR OR SUBCONTRACTOR SHALL BE FAMILIAR WITH THE WORK OF OTHER CONTRACTORS OR SUBCONTRACTORS, WHETHER OR NOT SHGNN ON THIS DOCUMENT WHICH IMPACTS THE WORK IMPACTS THE WORK SHOWN FRESH AND SHALL DOMINATE SUCH WORK SO AS TO EF IN MMPLWHOEWM THEINTNTOFP THEPROFCT DOCUMENTS. St. Vincent Carmel Hospital Carmel Pharmacy 797 800 13500 N Meridian Street MIS" DRAWING CONTENTS: BASEMENT FLOOR REFLECTED CEILING PLAN ISSUE DATE'. PROJECT NO. 04/26/2019 MKM'. 17107 ASCENSION. W286 DATE: 09/04/19 DRAWING NO. A-130