E001-ELECTRICAL-SYMBOLS,-ABBREVIATIONS-AND-GENERAL-NOTES-Rev.0
ELECTRICAL EQUIPMENT SYMBOL DESCRIPTION - - MOLDED CASE CIRCUIT BREAKER CURRENT TRANSFORMER �IH GROUND CONNECTION • GROUND POINT ® GROUND ROD 0 LIGHTNING PROTECTION AIR TERMINAL ❑X PAD MOUNTED TRANSFORMER(9(' DENOTES KVA SIZE) It BRANCH PANELBOARD AND CABINET - RECESSED MOUNT MEN BRANCH PANELBOARD AND CABINET - SURFACE MOUNT SM DISTRIBUTION PANELBOARD AND CABINET - SURFACE MOUNT O ELECTRIC THERMOSTAT b MOTOR(R' DENOTES HORSEPOWER) PF CAPACITOR FX' DENOTES KVAR) x 0' DISCONNECT SWITCH - FUSED a DISCONNECT SWITCH -NON -FUSED ® MOTORCONTROLLER ®' COMBINATION MOTOR CONTROLLER I] JUNCTION OR PULL BOX fH PUSHBUTTON OR PUSH PLATE O GENERATORIALTERNATOR 0 AUTOMATIC TRANSFER SWITCH SYMBOL DESCRIPTION DUPLEX RECEPTACLE - NORMAL CIRCUIT (9P DENOTES AS FOLLOWS I p DUPLEX RECEPTACLE -EMERGENCY Tr CI RCUIT(FX' DENOTES AS FOLLOWS'I QUADRAPLEX RECEPTACLE - NORMAL CI RCUIT('X' DENOTES AS FOLLOWS.) p QUADRAPLEX RECEPTACLE - EMERGENCY K CI RCUIT('X' DENOTES AS FOLLOWS'I SI MPLEX RECEPTACLE - NORMAL CIRCUIT ('X' DENOTES AS FOLLOWS'I SI MPLEX RECEPTACLE - EMERGENCY CI RCUIT(9(' DENOTES AS FOLLOWS') NONE-20 AMP, 125VAC GFCI-20 AMP, 125VAC, G ROUND FAULT CURRENT I WERRUPTER TYPE HM - 20 AMP, 125VAC, HORIZONTAL MOUNT TYPE I - 20 AMP, 125VAC, ISOLATED GROUND TYPE S -20 AMP.. 125VAC, SURGE GUARD PROTECTION TYPE ST - 20 AMP, 125VAC, SAFETY TYPE AS- 20 AMP, 125VAC, WEATHERPROOF TYPE SPECIAL RECEPTACLE -NORMAL CIRCUIT (SEE DRAWINGS AND SPECIFICATIONS) SPECIAL RECEPTACLE - EMERGENCY P CIRCUIT (SEE DRAWINGS AND SPECIFICATIONS) ®® DUPLEX -CE I LI NO MOUNTED ®® QUADRAPLEX-CEILING MOUNTED ® FLOOR BOX (DUPLEX) ® ® FLOOR BOX (QUADRAPLEX) 1.1 FLOOR BOX (BLANK) ® FLOOR BOX (POWER AND DATA) Wo AoW PLUGSTRI P(POWE R AND/OR DATA) $ TOGGLE SWITCH- 20 AMP, 120277VAC 3$ TOGGLE SWITCH-3-WAY 4$ TOGGLE SWITCH -4WAY P $ TOGGLE SWITCH - PILOT LIGHT K $ TOGGLE SWITCH - KEY OPERATED D$ INDIVIDUAL LIGHT DIMMER LETTER DESIGNATION INDICATES SWITCH LEG $T HORSEPOWER RATED MANUAL MOTOR STARTER TOGGLE SWITCH WITH THERMAL OVERLOAD PROTECTION TELEVISION SYSTEM SYMBOL DESCRIPTION © TV SYSTEM OUTLET ® AUDIOIVISUAL CONTROLLER FP FLAT PANEL TV WITH RECESSED WALL BOX CLOCK SYSTEM SYMBOL DESCRIPTION F© WALL MOUNTED CLOCK F® DI GITAL TIME CLOCKIE LAPSE D TI ME SYSTEM OUTLET RACEWAY SYSTEM SYMBOL DESCRIPTION PHASE CONDUCTORS SOLATED GROUND AGROUND QUANTITY OF CONDUCTORS OR CABLES IN CONDUIT LNEUTRAL RELEASED FOR CONSTRUCTION Subject to compliance with all regulations at State and Local Codes City of Cannel FIRE ALARM SYSTEM SYMBOL DESCRIPTION SD SMOKE DETECTOR(FX' DENOTESAS FOLLOWS) x R-RELAY BASE HD HEAT DETECTOR FD FLAME DETECTOR DD x DUCT DETECTOR(9(' DENOTES AS FOLLOWS) S-SUPPLY R-RETURN AR ADDRESSABLE RELAY RI REMOTE INDICATOR STATION RT REMOTE TEST STATION BD BEAM DETECTOR MI MANUAL PULL STATION FS FLOW SWITCH TS TAMPER SWITCH HORN ONLY - WALL MOUNT L^P HORN STROBE -WALL MOUNT ID CHIME ONLY - WALL MOUNT IO CHIME STROBE - WALL MOUNT rMOO SPEAKER ONLY - WALL MOUNT LJII SPEAKER STROBE -WALL MOUNT Iz BELL ONLY- WALL MOUNT 00 BELL STROBE -WALL MOUNT VI SUAL ONLY - WALL MOUNT HORN ONLY - CEI LI NO MOUNT HORN STROBE -CEILI NO MOUNT CHIME ONLY -CEI LI NG MOUNT C CHI ME STROBE -CE I LING MOUNT 0 SPEAKER ONLY -CEI LI NG MOUNT ,,(ff�,�qq� SPEAKER STROBE -CE ILI NG MOUNT B BELL ONLY - CEI LI NG MOUNT B BELL STROBE -CE ILI NG MOUNT VISUAL ONLY - CEILING MOUNT DH DOOR HOLD OPEN I] ADDRESSABLE MODULE FACEFIRE ALARM CONTROL PANEL FEMPI FIRE ALARM ANNUNCIATOR PANEL FANP FIRE ALARM NOTIFICATION APPLIANCE PANEL FFATC1 FIRE ALARM TERMINAL CABINET GC FIRE ALARM GRAPHICS COMMAND CENTER FT FIREMEN'S TELEPHONE ® RESCUE ASSISTANCE STATION (AREA OF REFUGE) SYMBOL DESCRIPTION '® MICROPHONE INPUT RECEPTACLE - WALL MOUNTED O MICROPHONE INPUT RECEPTACLE - FLOOR MOUNTED ® MICROPHONE INPUT RECEPTACLE - CEILING MOUNTED ® WALL MOUNTED PAGING HORN SPEAKER (ROUGH -IN) © LOUDSPEAKER -CEILING MOUNTED ©N LOUDSPEAKER- CEILING MOUNTED WITH VOLUME CONTROL TO LOUDSPEAKER - WALL MOUNTED Il VOLUME CONTROL I NURSE CALL SYSTEM I SYMBOL DESCRIPTION QM MASTERSTATION QD DUTY STATI ON SQ EMERGENCY STAFF ASSIST STATION SO EMERGENCY STAFF ASSIST STATION wl 2-WAY AUDIO A SDCB EMERGENCY STAFF ASSIST STATION wI CODE BLUE Ep BATH STATION DA BATH STATION W 2-WAY AUDIO © PATIENT STATION ©C PATIENT STATION - SINGLE OUTLET WITH CODEISTAFF ASSIST BUTTON ® CODE CALL STATION (CODE BLUE) ® CODE CALL STATION (CODE PINK) © WALL MOUNTED DOME LIGHT ©T WALL MOUNTED DOME LIGHT WTONE CL CEILING MOUNTED DOME LIGHT ®T CEILING MOUNTED DOME LIGHT wl TONE 0 ZONE LIGHT ® ROOM STATUS INDICATOR Ap REMOTE ANNUNCIATOR Xp NURSE AUXILIARY JACK ® NURSE AUXILIARY JACK -DOUBLE ® BED CONNECTOR TELEMETRY ANTENNA LOCATION © RTLS(REAL TIME LOCATI NG SYSTEM ANTENNA) PATIENT CARE SYSTEM SYMBOL DESCRIPTION SYMBOL DESCRIPTION 12'x48'LIGHT FIXTURE IIIIII� HALF SHADED INDICATES LIFE SAFETY POWER — FULL SHADED INDICATES EMERGENCY POWER 24N24' LIGHT FIXTURE ® 24' WALL LIGHTS ® 36' WALL LIGHTS ® 48' WALL LIGHTS 24' STEM MOUNTED WALL LIGHTS 36'STEM MOUNTED WALL LIGHTS 48' STEM MOUNTED WALL LIGHTS Q WALL MOUNTED SCONCE 24'048' LIGHT FIXTURE DOWN LIGHT eB II WALL MOUNTED EMERGENCY BATTERY LIGHT CEILING MOUNTED EMERGENCY BATTERY LIGHT } } EXIT LIGHT DIRECTIONAL ARROWS IR CEILING MOUNTED EXIT LIGHT (DUAL FACED) CEILING MOUNTED EXIT LIGHT HO WALL MOUNTED EXIT LIGHT 'p EXTERIOR POLE LIGHTS (SINGLE HEADS) O.O EXTERIOR POLE LIGHTS (DOUBLE HEADS) 020 EXTERIOR POLE LIGHTS (THREE HEADS) pYp O� EXTERIOR POLE LIGHTS (FOUR HEADS) EXTERIOR POLE LIGHTS (POLE TOP MOUNT) } EXTERIOR LIGHTS (BOLLARDS) EQ GROUND FLOOD LIGHT 0 EXTERIOR FLOOD LIGHT ® DUAL BALLAST (NORMAL AND EMERGENCY) LC LIGHTING CONTROLLER O MOTION DETECTOR(LIGHT SWITCH) ® OCCUPANCY SENSOR -WALL MOUNTED © OCCUPANCY SENSOR -CEI LI NG MOUNTED VS VACANCY SENSOR -WALL MOUNTED Q VACANCY SENSOR -CEILING MOUNTED ® PHOTOCELL - WALL MOUNTED © PHOTOCELL -CE I LING MOUNTED TELECOMMUNICATION SYSTEM SYMBOL DESCRIPTION • LIFE SAFDETY TELEPHONE LINE (POTS) vW VOICE ONLY OUTLET (WALL OUTLET) DATA ONLY OUTLET WAD O WIRELESS ACCESS POINT O FLOOR BOX (VOICE, DATA, VOICEIDATA) ®PRO) AP ® CEILING MOUNTED (DATA, VOICEIDATA) TELECOMMUNICATIONS EQUIPMENT RACK SECURITY SYSTEM SYMBOL DESCRIPTION MTV CCTV MONITOR OUTLET % DOOR BUZZER ® ELECTRIC DOOR RELEASE BUTTON ES ELECTRIC DOOR STRIKE IC INTERCOM UNIT FLUSH MOUNTED © INTERCOM -CEILING MOUNTED MI MASTER INTERCOM AND DIRECTORY UNIT SCP SECURITY CONTROL PANEL ML SECURITY MAGNETIC DOOR LOCK ® SECURITY CARD READER ©K COMBINATION CARD READERWITH KEYPAD ® MOTION DETECTOR -WALL MOUNTED MD MOTION DETECTOR -CEILING MOUNTED ® SECURITY DOOR CONTACTS PB SECURITY EXIT PUSH BUTTON ® SECURITY MONITOR REX SECURITY DOOR REQUEST TO EXIT MOTION DETECTOR KP SECURITY KEYPAD BS BIOSCAN ACCESS PAD PR DURESS ALARM (HOLD UP BUTTON) PT ELECTRIC POWER TRANSFER © PUSH PLATE TA TOUCHLESS ACTUATOR © DOOR RELEASE PUSH BUTTON PS DOOR POWER SUPPLY CAMERA E�4 CAMERA - EXTERIOR EXT CAMERA -PAWLLT200M PTZ ADO1 AUTO DOOR OPERATION OM DATA ONLY(PATI ENT MONITOR) VTM DATA ONLY OUTLET (TELEMETRY) LINE SYMBOLS —/— LIGHTISCREENED SOLID OR DASHED LINES INDICATE EXISTING TO REMAIN — — — HEAVY DASHED LINES INDICATE EXISTINGTOBE REMOVED HEAVY CONTINUOUS LINES INDICATE NEW WORK —SZ— HEAVY CONTINUOUS LINES INDICATE SPRINKLER ZONE FLOOR PLAN SYMBOLS SYMBOL DESCRIPTION OPLAN NOTE A. GENERAL NOTE ELECTRICAL ABBREVIATIONS ABBREV. DESCRIPTION ABBREV. DESCRIPTION A orAMP AMPERE HZ HERTZ AC ALTERNATING CURRENT IC INTERCOMMUNICATION A/C AIR CONDITIONING ID INSIDE DIAMETER ACP ACCESS PANEL INCAN INCANDESCENT AGO AIR CONDITIONING UNIT INCL INCLUDE ADD ADDITION ISO ISOLATED GROUND SURGE GUARD ADJ ADJUSTABLE JB JUNCTION BOX AF AMPEREFRAME JT JOINT AFC ABOVE FINISHED CEILING KEC KITCHEN EQUIPMENT CONTRACTOR AFF ABOVE FINISHED FLOOR KT KITCHENETTE AFG ABOVE FINISHED GRADE KVA KILOVOLT AMPERE AHU AIR HANDLING UNIT KVAR KILOVOLT AMPERE REACTIVE AIC AMPERE INTERRUPTING CAPACITY KW KILOWATT AL ALUMINUM LAB LABORATORY AM AMMETER LB POUND AMB AMBIENT LF LINEAR FEET APPROX. APPROXIMATELY LOC LOCATION ARCH ARCHITECT LS LIFE SAFETY ATS AUTOMATIC TRANSFERSWITCH LT LIGHT AUTO AUTOMATIC LTG LIGHTING AVG AVERAGE LV LOWVOLTAGE BC BARE COPPER MATV MASTER ANTENNA TELEVISION BKR BREAKER MAX MAXIMUM BHP BRAKE HORSEPOWER MC MECHANICAL CONTRACTOR BL BUILDING LINE MCB MAIN CIRCUIT BREAKER BLDG BUILDING MCC MOTOR CONTROL CENTER BR BRANCH MOP MAIN DISTRIBUTION PANEL BTM BOTTOM MECH MECHANICAL C CONDUIT MH MANHOLE 'C DEGREES CELSIUS MIN MINIMUM CAB CABINET MISC MISCELLANEOUS CB a CIS CI RCUIT BREAKER MLO MAIN LUGS ONLY CC CENTER TO CENTER MTD MOUNTED CCTV CLOSED CIRCUIT TELEVISION MTG HT MOUNTING HEIGHT CKT CIRCUIT MU MEDICINE UNIT CL CENTERLINE OD OUTSIDE DIAMETER CLG CEILING OFCI OWNER FURNISHED -CONTRACTOR INSTALLED COL COLUMN OFOI OWNER FURNISHED -OWNER INSTALLED Comm COMMUNICATION GOING OPENING COMP COMPRESSOR OPP OPPOSITE CONC CONCRETE OR OPERATING ROOM CONST CONSTRUCTION P POLE CONT CONTINUOUS PB PUSHBUTTON CONTR CONTRACTOR PBOX PULL BOX CR CRITICAL PE PNEUMATIC ELECTRIC CONVERTER CT CURRENT TRANSFORMER OF POWER FACTOR CU COPPER PH or PHASE DB DIRECT BURIAL PV POST INDICATORVALVE DC DIRECT CURRENT PAIL PANELBOARD DEPT DEPARTMENT PL PILOT LIGHT DF DRINKING FOUNTAIN PREFAB PREFABRICATED DIST DISTRIBUTION ORES PRESSURE DM DEMAND METER PT PNEUMATIC TUBE DO DRAWOUT PTS PNEUMATIC TUBE STATION DRS DOCTORS PW PART WINDING DWG DRAWING PAR POWER EC ELECTRICAL CONTRACTOR RACU ROOM AIR CONDITIONING UNIT EF EXHAUST FAN RAD RADIATION ELEC ELECTRIC RECEPT RECEPTACLE ELEV ELEVATOR REFor REFR REFRIGERATOR ELV ELEVATION REINF REINFORCED EMER EMERGENCY RIGID REMOTE GROUND INDICATING PANEL ENCL ENCLOSURE RM ROOM EP ELECTRIC PNEUMATIC RPM REVOLUTIONS PER MINUTE EQUIP EQUIPMENT SA SUPPLYAIR EWC ELECTRIC WATER COOLER Sc SHORT CIRCUIT EX EXPLOSIONPROOF SG SURGE GUARD PROTECTION EXH EXHAUST SHT SHEET EXP EXPANSION SIG SIGNAL EXT EXTERIOR SN SOLID NEUTRAL OF DEGREES FAHRENHEIT SPEC SPECIFICATIONS FA FIRE ALARM SO SQUARE FAAP FIRE ALARM ANNUNCIATOR PANEL SS SAFETY SWITCH FACP FIRE ALARM CONTROL PANEL SSSS SOLID STATE SOFT START FC FLAT CABLE STD STANDARD FCU FAN COIL UNIT STN STATION FFC FOOD FACILITY CONTRACTOR STR STRUCTURAL FFS FOOD FACILITY SUPPLIER SUSP SUSPENDED FHC FIRE HOSE CABINET SW SWITCH FIN FINISH SWBD SWITCHBOARD FIXT FIXTURE SWGR SWITCHGEAR FL FLOOR TCC TEMPERATURE CONTROL CONTRACTOR FLUOR FLUORESCENT TELE TELECOMMUNICATION FLEX-CONN FLEXIBLE CONNECTION TEMP TEMPERATURE FPC FIRE PROTECTION CONTRACTOR TMH TOP OF MANHOLE FSS FUSED SAFETY SWITCH TV TELEVISION FTG FOOTING TYP TYPICAL FVR FILMVIEWER UC UNDER CARPET FV FULL VOLTAGE UIC UNDER CABINET or UNDER COUNTER FVNR FULL VOLTAGE NON REVERSING UH UNIT HEATER G orGND GROUND UV UNIT VENTILATOR GALV GALVANIZED V VOLT GC GENERAL CONTRACTOR VAC VACUUM GEN GENERATOR VB VACUUM BREAKER GFCI GROUND FAULT CKT. INTERRUPTER VC VACUUM CLEANING GFI GROUND FAULT INTERRUPTER VEL VELOCITY (STEP GROUND FAULT PROTECTION VIED VARIABLE FREQUENCY DRIVE HGT HEIGHT VIM VOLTMETER HH HANDHOLE VOL VOLUME HID HIGH INTENSITY DISCHARGE OP VAPORPROOF HO HAND OPERATED VSDNFC VARIABLE SPEED DRIVE/CONTROLLER FICA HAND -OFF -AUTOMATIC WI WITH HORZ HORIZONTAL WIO WITHOUT HP HORSEPOWER WTR WATER FIRS HIGH PRESSURE SODIUM WP WEATHERPROOF HTR HEATER `.NT WEIGHT HV HIGH VOLTAGE XFMR TRANSFORMER Z IMPEDANCE NOTE: ALL SYMBOLS AND ABBREVIATIONS MAY NOT BE USED ON THIS PROJECT GENERAL NOTES: A. REFER TO'HPE'SERIES DRAWINGS FORADDITIONAL ELECTRICAL WORK NOT INDICATED ON THE ELECTRICAL DRAWINGS. B, ALL CONDUITS SHALL BE RUN ABOVE FINISHED FLOOR OF WHICH IT IS SERVING UNLESS OTHERWISE NOTED. CONDUITS ARE NOT PERMITTED TO BE RUN IN CONCRETE SLAB. C. REFERTO ARCHITECTURAL SCHEDULES, DETAILS AND ELEVATIONS FORADDITIONAL INFORMATION ON DEVICE LOCATIONS PRIORTO ROLIGH- IN, D. VERIFY TYPE OF CEILING, GRID SYSTEM SPECIFICATIONS (IF APPLICABLE), AND MOUNTING RESTRICTIONS WITH ARCHITECTURAL DISCIPLINE PRIOR TO ORDER FOR LUMINARIES. E. MOUNTING OF JUNCTION BOXES BACK-TOBACK IS NOT PERMITTED. F. ELECTRICAL DEVICES INSTALLED ON VERTICAL FIRE RESISTIVE ASSEMBLIES CLASSIFIED AS FIREISMOKE PARTITIONS SHALL BE INSTALLED WITH OPENING ON ONE SIDE ONLY IN EACH FRAMING SPACE AND THAT OPENING SHALL NOT EXCEED 16 SQUARE INCHES. ALL CLEARANCES BETWEEN SUCH DEVICES AND THE GYPSUM BOARD SHALL BE COMPLETELY FILLED WITH JOINT COMPOUND OR OTHER UL APPROVED MATERIAL. G. WHERE SPACE ALLOCATIONS WITH REGARD TO ELECTRICAL EQUIPMENT ARE NOT ADEQUATE FOR THE SPECIFIED ELECTRICAL EQUIPMENT. THE ENGINEER SHALL BE CONSULTED BEFORE ORDERING THE EQUIPMENT AND ANY INSTALLATION IS PERFORMED. H. COORDINATE LOCATIONS OF ALL CEILING MOUNTED ELECTRICAL AND MECHANICAL EQUIPMENT INCLUDING, BUT NOT LIMITED TO LUMINARIES, LOUDSPEAKERS, SMOKE DETECTORS, ETC. WITH THE ARCHITECTURAL REFLECTED CEILING PLAN. REFER TO SPECIFICATIONS FOR RESTRICTIONS OF PARTICULAR DEVICE PLACEMENT. I. MAINTAIN AND SUBMIT AS -BUILT DRAWINGS SHOWING ALL MODIFICATIONS (BOTH IN THE FIELD AND AS DIRECTED BY CM, OWNER OR ENGINEER) TO LIGHTING, POWER AND SYSTEMS PLANS TO ARCHITECTIENGINEERAND OWNER. J. PROVIDE NEW, TYPED PANELBOARD CIRCUIT DIRECTIONS IN NEW PANELBOARDS. K. CONDUIT FLOOR SLEEVES SHALL BE INSTALLED 2'ABOVE FINISHED FLOOR AND SHALL BE FIRE PROOFED USING APPROVED FIRE RESISTIVE MATERIAL L, CUTTING AND PATCHING WALLIFLOOR AND/OR CORE DRILL WALLIFLOOR FOR ELECTRICAL WORK SHALL BE THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR, OR AS ASSIGNED BY CM. % CONTRACTOR SHALL BE RESPONSIBLE TO FIREPROOF PENETRATIONS AT SMOKE WALL FIREISMOKE WALL AND ROOF. N. PROVIDE UNISTRUT AND/OR MISCELLANEOUS IRON/ANGLE AS REQUIRED TO INSTALLISUPPORT LIGHT FIXTURES, STARTERS, DISCONNECT, PANELBOARD, ETC. 0. ALL CIRCUITS ARE 20 AMP, SINGLE -POLE UNLESS INDICATED OTHERWISE. P. MI NI MUM WI RE SIZE SHALL BE 12 AWG UNLESS I NDI GATED OTHERWISE. MI NI MUM CONDUIT SIZE SHALL BE 3'4' UNLESS I NDICATED OTHERWISE. Q, ALL NEW CIRCUITS SHALL CONTAIN A G ROUND WI RE. R. EACH NEUTRAL WIRE SHALL BE DEDICATED TO A CIRCUIT. DO NOT SHARE NEUTRAL WIRE WITH MULTIPLE CIRCUITS. S, IN PANELS, SWITCHBOARDS AND MOTOR STARTER PANELS WHERE NEW CIRCUIT BREAKERS,ETC. ARE INSTALLED THE A/C RATING SHALL MEET OR EXCEED THE EXISTING RATINGS. T. CONTRACTOR SHALL VERIFY CORD AND PLUG CONNECTED EQUIPMENT CORD CONFIGURATION AND PROVIDE MATCHING RECEPTACLE AS REQUIRED. U. ALL RECEPTACLES WITHIN SIX FEET OF A SINK SHALL BE IDENTIFIED AS GFCI ON THE PLANS, BUT SHALL BE PROVIDED ACCORDING TO THE REQUIREMENT. MKM architecture design 119 West Wayne Street Fort Wayne, Indiana 46802 R 260.422.0783 r 260.426.4561 WWW.MKMdesion.eom PE10606505 STATE OF Cumunanl Logo: BSA BEAL6eStruAres 9365 COun altre Row Suite SIX Indianapolis, IN 46240-1478 ph 317.819.7878 fx 317.819.7288 Key P6n: TIE PROPERTY OF MNM ARCH ECTURE. DESIGN, AHD WERE CREATEDPHD DEVELOPED FOR USE ON, AHD IN CONNECTION WITH THIS SPECIFIC PROJECT HONE OF THE IDEV9, DESIGNS, ARRANGEMENTS OR PUNS SHUL BE USED By OR DISCLOSED TO ANV PERSON, FIRM OR CORPORATION FOR AN. PURPOSE WHATSOEVeR NTwUT THE WRITTEN PERMISSION OF MIKE ARCHnECTURE , DESMN. THE OVMER SI BE PERMITTED TO RETAIN COPIES FOR INFORMATION AND REFERENCE IN CONNECTION NTH THIS PROJECT WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALE DIMENSIONS. AMID THIS OFFICE MUST BE NOTIFIED OF ANV SHVARIATION FROM ME DIMENSIONS AND CONDITIONS OWN BY THESE CAMMACK SHOP DRAWNGS MOST SE SUBMITTED TO THIS OFFICE FOR REVIEW BEFORE PROCEEDING NTH FABRICATION AIDW R INSTALLATION. ME WORK SHOWN ON THIS DOCUMENT AND THE CORRESPONDING SPECIFICA9a15, INTERFACES WITH WORK SHOWN ON OTHER DOCUMENTS INCLUDING WORK N BE PERFORMED BY OTHER CONTRACTORS OR SUBCONTRACTORS. EACH CONTRACTOR OR SUBCONTRACTOR SH L1 BE FAMILIAR NTH THE WORK OF OTHER CONTRACTORS OR sOBcoxmACTORs. WHETHER OR NOT SHOWN ON THIN DOCUMENT, MICH IMPACTS THE WORK IMPACTS THE WORK SHOWN HEREON AND SHALL COORDINATE SUCH WORK SD AS TO BE IN COMPLIANCE NTH THE INTENTOF ALLTHE PROJECT DOCUMENTS. E4 St. Vincent Carmel Hospital Carmel Pharmacy 797 800 13500 N Meridian Street REVISION DRAWING CONTENTS: ELECTRICAL SYMBOLS, ABBREVIATIONS AND GENERAL NOTES ISWE DATE: PROJECT NO. 0426/2019 Bea 17107 ASCENSION: 30286 DATE: 09/04/19 DRAWING NO E001