HomeMy WebLinkAboutE600-ELECTRICAL-RISER,-SCHEDULES,-AND-DETAILS-Rev.0LA RELEASED FOR CONSTRUCTION LIGHT FIXTURE SCHEDULE NOTE: SEE SPECIFICATION SECTION 260923, 260933, 260936, 265100, 265561, 265600, 265668 FOR ADDITIONAL INFORMATION REGARDING LIGHTING FIXTURES AND INSTALLATION REQUIREMENTS. PROVIDE OPTIONS AND ACCESSORIES BY THE REFERENCED COLUMN TITLED "REMARKS". MANUFACTURERS LISTED SHALL MEET ALL REQUIREMENTS AND FEATURES INDICATED. FIXTURE DIMENSIONS LAMP DATA x � x � x FIXTURE o z O COLOR DELIVERED MANUFACTURER CATALOG TYPE 3 � Ill M DIA DESCRIPTION VOLTAGE WATTAGE TYPE TEMP LUMENS SERIES ACCESSORIES/OPTIONS Lf 24' 48' 6' 0-0' CLEANROOM TROFFER 120V 45W LED 3500K 5700 FAIL-SAFE - CUM, MINIMUM 90 CRI, WET LOCATION LISTED, SEALED KURTZON - EL, AND GASKETED, ISO 7 MINIMUM RATING KENALL -CSEDI L2 24' 48' 6' 0-0' CLEANROOM TROFFER 120V 72W LED 3500K BBDD FAIL-SAFE -CUA, MINIMUM 90 CRI, WET LOCATION LISTED, SEALED KURTZON-EL, AND GASKETED, ISO 7 MINIMUM RATING KENALL-CSEDI VARIABLE FREQUENCY CONTROLLER SCHEDULE EQUIPMENT DATA CIRCUIT BREAKER BYPASS CONTROLLER NEMA DESIGNATION LOAD SERVED LOCATION HP FLA VOLTAGE PHASE FRAME SIZE TRIP SIZE TYPE NEMA SIZE ENCLOSU RE COMMENTS VFC-EKF15A EXF-15A hECH ROOM 2 3.4 480 3 30 15 NNR 00 TYPE) VFC-EXF15B EXF-15B NECH ROOM 1.5 3.0 480 3 30 15 NNR 00 TYl'E7 Branch Panel: BLC3 Location: PHARMACYBWO069 Supplied From: Mountino: Recessed Enclosure Type: Type 1 General Panel Comments: 1. EXISTING PANELBOARD AND CIRCUIT BREAKERS. Voles Phase: Wire: Ground: 1201208 Wye 3 4 YES Branch: CRITICAL &I.C. Raltnu: 10K Main Type: MCB Main RaBnu: 100 A Circuit Number Circuit Description Trip Poles A B C Poles Trip Circuit Description Circuit Number 1 EXISTING CIRCUIT 20A 1 0.0 0.0 1 20A EXISTING CIRCUIT 2 3 EXISTING CIRCUIT 20A 1 0.0 0.0 1 20A EXISTING CIRCUIT 4 5 EXISTING CIRCUIT 20A 1 0.0 0.0 1 20A EXISTING CIRCUIT 6 7 EXISTING CIRCUIT 20A 1 0.0 0.0 1 20A EXISTING CIRCUIT 8 9 EXISTING CIRCUIT 20A 1 0.0 0.0 1 20A EXISTING CIRCUIT 10 11 EXISTING CIRCUIT 20A 1 0.0 0.0 1 20A EXISTING CIRCUIT 12 13 EXISTING CIRCUIT 20A 1 0.0 0.0 1 20A EXISTING CIRCUIT 14 15 EXISTING CIRCUIT 20A 1 0.0 0.0 1 20A EXISTING CIRCUIT 16 17 BWO074,76,77,83-RECEPS 20A 1 0.2 0.0 1 20A EXISTINGCIRCUIT 18 19 BW 0083 -FREEZER 20A 1 0.4 0.0 1 20A EXISTING CIRCUIT 20 21 BWO076-NMTHHOW 20A 1 0.4 0.0 1 20A EXISTING CIRCUIT 22 23 EXISTING CIRCUIT 20A 1 0.0 0.0 1 20A EXISTING CIRCUIT 24 25 EXISTING CIRCUIT 20A 1 0.0 0.0 1 20A EXISTING CIRCUIT 26 27 EXISTING CIRCUIT 20A 1 0.0 0.0 1 20A EXISTING CIRCUIT 28 29 EXISTING CIRCUIT 20A 1 0.0 0.0 1 20A EXISTING CIRCUIT 30 31 EXISTING CIRCUIT 20A 1 0.0 0.0 1 20A SPARE 32 33 EXISTING CIRCUIT 20A 1 0.0 0.0 1 20A EXISTING CIRCUIT 34 35 EXISTING CIRCUIT 20A 1 0.0 0.0 1 20A SPARE 36 37 SPARE 20A 1 0.0 0.0 1 20A EXISTING CIRCUIT 38 39 EXISTING CIRCUIT 20A 1 0.0 0.0 1 20A EXISTING CIRCUIT 40 47 EXISTING CIRCUIT 20A 1 0.0 0.0 1 20A EXISTING CIRCUIT 42 Total Load: 0.4 kVA 0.4 IVA 0.2 kVA Total Connected Load... Total Connected Load (Amps): 1.0 kVA 2.8 A Remarks: LAY -IN CEILING T-BAR LAY -IN CEILING TILE ATTACH OCTAGON BOX TO THE FIXTURE HANGER 4-OCTAGON 112' WORKBOX ROMEX CONNECTOR OCCUPANCY SENSOR ATTACH SENSOR TO OCTAGON BOX. CENTER IN THE CEILING TOLE. NOTE: LOW VOLTAGE CABLES SHALL BE SUPPORTED TO BE OFF OF THE CEILING GRID AND CEILING TILE. SUPPORT CABLES TO THE BUILDING STRUCTURE UTILIZING VELCRO OR CABLE TIES. �\ OCCUPANCY SENSOR MOUNTING DETAIL NO SCALE SNAP ON FDGUREI BOX HANGER LAY -IN CEILING T-BAR ATTACH FIXTURE HANGER TO CEILING GRID. VARIABLE FREQUENCY CONTROLLER BYPASS CONTACTOR BYPASS CONTACTOR ENCLOSURE NON -FUSED SAFETY SWITCH WITH AUXILIARY INTERLOCK SIEMENS-ALLIS MARQ MCC MCC -A 480V FED FROM BHE1 BACNET EXF-15A EXF-15B 617 AHU-7 RECIRCULATION PUMPAHU-6 AHU6 SUPPLY FAN 1 AHU6 SUPPLY FAN 2 SPARE AHU4 SUPPLY FAN 1 HRU-1 AM-FL01 2BLE AHU4 SUPPLY FAN 2 lAM-FL01 FAN NO 31 SPARE AHUIRELIEF AHU4 RELIEF FAN SPARE 5% LINE REACTOR CIRCUIT BREAKER WITH DOOR INTERLOCK ISOLATION CONTACTOR 5\ VARIABLE FREQUENCY CONTROLLER SCHEMATIC No SCALE i1 MCC -A ELEVATION NOSCALE CADDY SCREW GL METAL STUDS GENERALNOTES A. REFER TO SHEET E001 FOR ELECTRICAL SYMBOLS AND ADDITIONAL GEN ERAL NOTES. PLAN NOTES Ill PROVIDE NEW DUAL CIRCUIT BREAKER FEEDER UNIT IN MCC FOR NEW EXHAUST FANS. BOTH CIRCUIT BREAKERS SHALL BE 480Vf3P115A. REFER TO RISER AND BEVATI ON ON SHEET E600. 617 DISCONNECT AND REM GIVE EXISTING BUCKET IN MCC AT THIS LOCATION. PROVID E NEW 0UAL CIRCUIT BREAKER FEEDER UNIT IN MCC FOR NEW EXHAUST FANS. BOTH CIRCUIT BREAKERS SHALL BE 480Vf3P115A. MECHANICAL ROOM, 3-C72, M12 CND, 3M' C I I I EXISTINGMCC 1uR EXF-15A 480Vf3P fill VFC VFC 2HP MCC -A BOX MOUNTING BRACKET NOTE: 1, FOR METAL STUD WALL CONSTRUCTION ONLY. 2. EITHER CADDY SCREW GUN BRACKET OR BOX MOUNTING BRACKET MAY BE USED AS STUD-TOSTUD SUPPORTS WALL BOX INSTALLATION DETAIL - DOUBLE MOUNT NO SCALE 3412, N12 GND, 3I4' C 1.5HP _ SECOND FLOOR FIRST FLOOR BASEMENT i1 NEW ELECTRICAL RISER NO SCALE COMBINATION BEAM CLAMI CONDUIT HANGER OR EQU....--,.. NOTE: FOR STEEL STRUCTURAL SYSTEM AND SMALLER CONDUIT SUPPORT DETAIL - STEEL BEAM SMALLER CONDUIT SUPPORT DETAIL - STEEL BEAM NO SCALE MKM architecture design 119 West Wayne Street Fort Wayne, Indiana 46802 p 260.422.0783 1260.426.4561 www.MKMdesion.eom PE10606505 STATE Or BSAettelmalures 9365 DoucGoal s, Raw Sum 330 Goal 78IN fx 17.819. Ph 317.819.7878 Tx 317.819.7288 K" Pan: TIE PROPERTY OF MKM ARCHITECTURE. DESIGN, AHD WERE CREATEDPHO DEVELOPED FOR USE ON, AHD IN CONNECTION WITH THIS SPECIFIC PROJECT HONE OF THE IDEAS DESIGNS, ARRANGEMENTS OR PUNS SHALL BE USED By OR DISCLOSED TO ANY PERSON, FIRM OR CORPORUION FOR ANY PURPOSE WHATSOEVER MHOMT THE WRITTEN PERMISSION OF PIKE ARCHITECTURE , reSpN. THE OWNER SHALL BE PERMITTED TO RETAIN COPIES FOR INFORMATION AND REFERENCE IN CONNECTION NTH THIS PROJECT WRITTEN DIMENSIONS ON THESE oMWTNGS SHALL HAVE PRECEDENCE OVER SCALE DIMENSIONS. AND THIS OFFICE MUST BE NOTIFIED OF ANY SHVARIATION FROM ME DIMENSIONS AND CONDITIONS OWN BY THESE DWNNGS. SHOP DRAWIGS MOST SE SUBMITTED TO THIS OFFICE FOR REVIEW BEFORE PROCEEDING NTH FABRICATION ANDSOR INSTALLATION. ME WORK SHOWN ON THIS DOCUMENT AND THE CORRESPONDING SPECIFICANg15, INTERFACES WRH WORK SHOWN ON OTHER OCCUMENTS INCLUDING WORK TO BE PERFORMED BY OTHER CONTRACTORS OR SUBCONTRACTORS. EACH CONTRACTOR OR SUBCONTRACTOR SH L1 BE FAMBWR NTH THE WORK of OTHER CONTRACTORS OR sOBcomRACTws. WHETHER OR NOT SHOWN ON THIS DOCUMENT, WHICH IMPACTS THE WORK IMPACTS THE WORK SHOWN HEREON AND SH 11 COORDINATE SUCH WORK SO AS TO BE IN COMPLIANCE NTH THE INTENTOF ALLTHE PROJECT DOCUMENTS. O 1rv�^ J z w U V) St. Vincent Carmel Hospital Carmel Pharmacy 797 800 13500 N Meridian Street REVISION CHINNING CONTENTS: ELECTRICAL RISER, SCHEDULES, AND DETAILS Subject to compliance with all regulations of State and Local Codes City of Camel �N;1Lv�law�,pMS� DATE: 09/04/19 SSUE DATE: PROJECT NO. 0426/2019 BSA: 17107 ASCENSION: 30286 DRAWING NO E600