Loading...
HomeMy WebLinkAboutA000.33.5:12 8:12 5:128:12 2030 FIXED 1012 1012 2030 FIXED 1012 8:12 8:12 24" LOUVERED SHUTTERS (U.N.O.) REF. PROD. SPEC. STONE SILL- REF. PRODUCT SPECS. 14" LOUVERED SHUTTERS (U.N.O.) REF. PROD. SPEC.BKT5X5 1"x6" TRIM STONE VENEER REF. PRODUCT SPECS. 1012 1012 8" ARCHED STONE HEADER -REF. PRODUCT SPECS. STANDING SEAM METAL ROOF 14" LOUVERED SHUTTERS (U.N.O.) REF. PROD. SPEC.SHINGLES PER - REF. PRODUCT SPECS. BKT5X5 \pxql;STONE VENEER REF. PRODUCT SPECS. 10121012 SIDING - REF. PRODUCT SPECS. SIDING - REF. PRODUCT SPECS. SHINGLE ROOF - REF. PRODUCT SPECS. 5:12 \A1;1'-1"O.H.\A1;1'-1"O.H.\A1;1'-1"O.H.\A1;1'-1"O.H.\A1;1'-1"O.H. \A1;1'-1"O.H.\A1;1'-1"O.H. \A1;27'-0" \pxqc;LINE OF PITCH CHANGE\pxqc;LINE OF PITCH CHANGE \A1;3'-6" \A1;2'-4" 1x12 MATERIAL 1x8 MATERIAL \A1;10'-6"\A1;10'-6" 12" RD TAPERED COL. ON 24"x24" STONE VENEER BASE1"x6" TRIM2X2 OVER 1X8 BOARD \A1;4'-6" A.F.F. MIN. 2 STEPS AT FRONT ENTRANCE W/ 18"-24" EXPOSED MASONRY PER COMM. SPECS. STONE SILL -\PREF. PRODUCT SPECS. \A1;9'-1{\H0.750000x;\S1#8;}"\A1;8'-2{\H0.750000x;\S7#8;}" WINDOW HEIGHT 1st FLR LINE PLATE HEIGHT TOP OF FOUNDATION \A1;3'-0" \pxql;8" ARCHED STONE HEADER -REF. PRODUCT SPECS. SCALE:FRONT ELEVATION1/4" = 1'-0"- BRICK HEIGHT SCALE:REAR ELEVATION1/8" = 1'-0"- 812812 \A1;8'-2{\H0.750000x;\S7#8;}" WINDOW HEIGHT 1st FLR LINE PLATE HEIGHT STONE VENEER REF. PRODUCT SPECS. SHINGLE ROOF - REF. PRODUCT SPECS. 5/4"x4" TRIM \pxql;SIDING - REF. PRODUCT SPECS. \A1;1'-1"O.H. 812 5/4"x6" TRIM \A1;4'-0"\A1;4'-0" BRICK HEIGHT TOP OF FOUNDATION \A1;9'-1{\H0.750000x;\S1#8;}"\A1;8'-2{\H0.750000x;\S7#8;}" 612 \A1;1'-1"O.H. \A1;2'-0" SCALE:LEFT ELEVATION1/8" = 1'-0"- BRICK HEIGHT 612 SCALE:RIGHT ELEVATION1/8" = 1'-0"- \A1;10'-0" \A1;16'-0" \A1;1'-0"\PTYP.\A1;8'-1{\H0.750000x;\S1#2;}"\A1;4'-11{\H0.750000x;\S1#4;}"\A1;7'-0{\H0.750000x;\S1#2;}" \A1;16'-0" \A1;10'-0" \A1;1'-0"\PTYP. SCALE:ROOF PLAN1/8" = 1'-0"- ROOF AREA"A"3287 SQ. FT. 6:12 6:12 10:1210:125:12 10:1210:12 10:1210:125:12 5:12 3.5:12 ELEVATION EC3M ATTIC VENT SCHEDULE VENTILATION REQUIRED AND SUPPLIED IS BASED ON POT VENT VALUES AND RIDGE VENT VALUES SHOWN IN TABLE ABOVE ** CONTRACTORS INSTALLING VENTILATION ARE RESPONSIBLE FOR VERIFYING THAT VENTS USED WILL SUPPY VENTILATION TO MEET CODE REQUIREMENTS * SCHEDULE HAS BEEN CALCULATED ASSUMING EAVE VENTILATION AT 50-60% OF TOTAL AND RIDGE AT 40-50% OF TOTAL REQUIRED VENTILATION ROOF AREA "A"SQ FTG 3287 AT / NEAR RIDGE AT / NEAR EAVE VENT TYPE SQ. FT. REQUIRED RANGE SQ. FT. SUPPLIED PERCENT OF TOTAL SUPPLIED POT LARGE (SQ. IN. EACH) POT SMALL (SQ. IN. EACH) RIDGE VENT (SQ. IN. PER LF) EAVE VENT (SQ. IN. EACH) CONT. VENT (SQ. IN. PER LF) 61.00 40.00 18.00 28.00 10.00 HIGH - POT VENTS ONLY 4.38 5.48 5.08 49.73 12 0 AT EAVE 6.57 5.48 5.14 50.27 0 74.00 TOTAL (MIN)10.96 10.96 10.22 100.00 3 HIGH - RIDGE VENT 4.38 5.48 5.75 52.81 0 0 46.00 AT EAVE 6.57 5.48 5.14 47.19 0 74.00 TOTAL (MIN)10.96 10.96 10.89 100.00 ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE SCALE :1/4" = 1'-0"INTERIOR PORCH ELEVATION EC3M SIDING - REF. PRODUCT SPECS.SIDING - REF. PRODUCT SPECS.SIDING - REF. PRODUCT SPECS.1"x6" TRIM 12" RD TAPERED COL. ON 24"x42" STONE VENEER BASE1"x6" TRIMSTONE WAINSCOT 1900 Golf Road, Suite 300Schaumburg, Illinois 60173Midwest Zone Office........................... PLAN NAME SHEET PRODUCTION MANAGER DATE / DESCRIPTION NPC PLAN NUMBERLAWSON PLAN ID GARAGE HANDING REV # NOTE: SCALES NOTED ON DRAWINGS RELATE TO FULL SIZE PLOTS ON 22x34 SHEETS - 11x17 SHEETS REPRESENT 1/2 SCALE PLOTS INITIAL RELEASE DATE:CURRENT RELEASE DATE: (c) Copyright Pulte Home Corporation - 2019 Suzette Schuette06/07/2013 GARAGE RIGHT Croix 1993.301 LOT 04 08/09/2019 PLOTTED: August 14, 2019 / Annie Lee / 1993-CROIX-CZ-BAS2-EL-EC3M.DWG A3 EC3M-2FS.1Elevation EC3M - Slab2 Car Front EntryFront, Side and Rear Elevations, Roof Plan and Ventilation Schedule09/04/19 Mike Sheeks