About
I38022973.4_Shadow_Wood
16023 Swingley Ridge Rd Chesterfield, MO 63017 314-434-1200 MiTek USA, Inc. Re: The truss drawing(s) referenced below have been prepared by MiTek USA, Inc. under my direct supervision based on the parameters provided by ProBuild (CarterLee Bldg Components). August 2,2019 Vance, Jeff Pages or sheets covered by this seal: I38022973 thru I38023043 My license renewal date for the state of Indiana is July 31, 2020. 4_Shadow_Wood 4 Shadow Wood IMPORTANT NOTE: The seal on these truss component designs is a certification that the engineer named is licensed in the jurisdiction(s) identified and that the designs comply with ANSI/TPI 1. These designs are based upon parameters shown (e.g., loads, supports, dimensions, shapes and design codes), which were given to MiTek or TRENCO. Any project specific information included is for MiTek's or TRENCO's customers file reference purpose only, and was not taken into account in the preparation of these designs. MiTek or TRENCO has not independently verified the applicability of the design parameters or the designs for any particular building. Before use, the building designer should verify applicability of design parameters and properly incorporate these designs into the overall building design per ANSI/TPI 1, Chapter 2. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Shadow_Wood Truss GE01 Truss Type GABLE Qty 1 Ply 1 4 Shadow Wood Job Reference (optional) I38022973 8.220 s Nov 16 2018 MiTek Industries, Inc. Fri Aug 2 10:25:03 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jAXtJ2ozokt8tlXqi1fHBQyGc1j-PBJRdefsR_d9G?9vbLstK_Y0NrZCwd1oBJP?H8yrw_k Scale = 1:60.3 Sheet Front Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 34 33 32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 35 36 373839 3x4 3x4 4x6 3x4 3x4 4x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 4x6 4x6 2x4 2x4 2-0-0 3-0-08-5-8 8-5-8 10-5-8 2-0-0 18-11-0 8-5-8 -0-11-0 0-11-0 9-5-8 9-5-8 18-11-0 9-5-8 19-10-0 0-11-0 1-3-09-1-91-3-010.00 12 Plate Offsets (X,Y)-- [28:0-0-0,0-1-12], [28:0-3-0,0-1-4], [29:0-1-4,0-0-0], [38:0-0-0,0-1-4], [39:0-0-0,0-1-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-SH 0.24 0.12 0.18 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.01 0.00 (loc) 17 17 18 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 308 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-34,16-18: 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. JOINTS 1 Brace at Jt(s): 35, 36, 37 REACTIONS.All bearings 18-11-0. (lb) - Max Horz 34=219(LC 5) Max Uplift All uplift 100 lb or less at joint(s) 27, 29, 30, 31, 32, 24, 23, 22, 21, 20 except 34=-136(LC 4), 18=-114(LC 5), 33=-166(LC 5), 19=-151(LC 4) Max Grav All reactions 250 lb or less at joint(s) 34, 18, 27, 29, 30, 31, 32, 33, 24, 23, 22, 21, 20, 19, 26, 25 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(10-11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 6) Gable studs spaced at 1-4-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 27, 29, 30, 31, 32, 24, 23, 22, 21, 20 except (jt=lb) 34=136, 18=114, 33=166, 19=151. 9) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 2,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Shadow_Wood Truss GE02 Truss Type GABLE Qty 1 Ply 1 4 Shadow Wood Job Reference (optional) I38022974 8.220 s Nov 16 2018 MiTek Industries, Inc. Fri Aug 2 10:25:04 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jAXtJ2ozokt8tlXqi1fHBQyGc1j-tNtpr_gUCIl0t9k592N6sB5CtFvLf6ByPz9Zqayrw_j Scale = 1:34.3 Sheet Front Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 26 25 24 23 22 21 20 19 18 17 16 2x4 2x4 3x6 3x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 0-1-1313-11-0 13-11-0 -0-11-0 0-11-0 5-3-7 5-3-7 8-7-9 3-4-2 13-11-0 5-3-7 14-10-0 0-11-0 1-3-05-6-15-7-141-3-05-6-110.00 12 Plate Offsets (X,Y)-- [6:0-3-0,0-2-1], [10:0-3-0,0-2-1] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-R 0.13 0.07 0.06 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.01 0.00 (loc) 15 15 16 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 177 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 6-10. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS.All bearings 13-11-0. (lb) - Max Horz 26=-136(LC 4) Max Uplift All uplift 100 lb or less at joint(s) 26, 16, 21, 23, 24, 25, 19, 18, 17 Max Grav All reactions 250 lb or less at joint(s) 26, 16, 21, 22, 23, 24, 25, 20, 19, 18, 17 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(12-13) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Provide adequate drainage to prevent water ponding. 5) Gable requires continuous bottom chord bearing. 6) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 7) Gable studs spaced at 1-4-0 oc. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 26, 16, 21, 23, 24, 25, 19, 18, 17. 10) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 12) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 13) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 2,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Shadow_Wood Truss GE03 Truss Type GABLE Qty 1 Ply 1 4 Shadow Wood Job Reference (optional) I38022975 8.220 s Nov 16 2018 MiTek Industries, Inc. Fri Aug 2 10:25:06 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jAXtJ2ozokt8tlXqi1fHBQyGc1j-pm_ZGgilkv0j7SuUGTQaxcAQt2SO7vpFtHeguTyrw_h Scale = 1:53.5 Sheet Front Left Option 7-5-6 1 Ply 7/16OSB8 1 2 3 5 6 7 8 4 13 12 11 10 9 33 5x10 MT18HS 3x4 2x4 4x8 4x10 5x12 3x4 3x4 2x4 3x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 4x8 3x6 0-1-130-4-8 0-4-8 7-5-6 7-0-14 7-9-0 0-3-10 7-10-12 0-1-12 8-10-12 1-0-0 12-0-6 3-1-9 13-2-3 1-1-14 21-8-0 8-5-13 -0-11-0 0-11-0 7-8-15 7-8-15 7-9-0 0-0-1 7-11-8 0-2-8 8-10-12 0-11-4 12-0-6 3-1-9 13-2-3 1-1-14 14-8-8 1-6-4 17-2-3 2-5-11 21-8-0 4-5-13 22-7-0 0-11-0 0-10-67-2-08-3-131-3-01-0-08-2-010.00 12 Plate Offsets (X,Y)-- [3:0-0-0,0-1-6], [3:0-4-11,0-2-14], [5:0-4-0,0-1-4], [12:0-7-0,0-3-8], [12:0-0-0,0-1-12], [14:0-2-0,0-0-4], [31:0-0-3,0-1-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-AS 0.68 0.60 0.50 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.11 -0.26 0.02 (loc) 12-13 9-10 9 l/defl >845 >625 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 248 lb FT = 20% GRIP 169/123 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 4-11: 2x3 SPF No.2 WEBS 2x3 SPF No.2 *Except* 7-9,12-14,14-31,31-32: 2x4 SPF-S Stud, 2-13: 2x6 SP 2400F 2.0E OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 3-5. BOT CHORD Rigid ceiling directly applied. WEBS 1 Row at midpt 4-10 REACTIONS.(lb/size)13=725/0-3-8, 11=485/0-3-8, 9=784/0-3-8 Max Horz 13=-191(LC 4) Max Uplift 13=-223(LC 6), 11=-109(LC 4), 9=-122(LC 7) Max Grav 13=725(LC 1), 11=576(LC 11), 9=784(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-657/291, 5-6=-630/250, 6-7=-278/106, 7-9=-320/126, 3-4=-356/257, 4-5=-429/227, 2-13=-621/278 BOT CHORD 12-13=-160/398, 11-12=-542/130, 4-12=-278/242, 9-10=-51/504 WEBS 10-12=-136/514, 6-9=-523/125 NOTES-(14-15) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Provide adequate drainage to prevent water ponding. 5) All plates are MT20 plates unless otherwise indicated. 6) The Fabrication Tolerance at joint 3 = 0%, joint 3 = 0% 7) Gable studs spaced at 1-4-0 oc. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 13=223, 11=109, 9=122. 11) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 12) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. 13) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. Continued on page 2 August 2,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Shadow_Wood Truss GE03 Truss Type GABLE Qty 1 Ply 1 4 Shadow Wood Job Reference (optional) I38022975 8.220 s Nov 16 2018 MiTek Industries, Inc. Fri Aug 2 10:25:06 2019 Page 2 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jAXtJ2ozokt8tlXqi1fHBQyGc1j-pm_ZGgilkv0j7SuUGTQaxcAQt2SO7vpFtHeguTyrw_h 14) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 15) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Shadow_Wood Truss GE04 Truss Type GABLE COMMON Qty 1 Ply 1 4 Shadow Wood Job Reference (optional) I38022976 8.220 s Nov 16 2018 MiTek Industries, Inc. Fri Aug 2 10:25:07 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jAXtJ2ozokt8tlXqi1fHBQyGc1j-IyYxT0iNVD8akcTgqBxpUqjjKSwtsTPO6xNDQvyrw_g Scale = 1:22.6 Sheet Front Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 6 10 9 8 7 2x4 3x4 3x4 2x4 2x4 2x4 2x4 2x4 2x4 0-1-114-0-0 4-0-0 -0-11-0 0-11-0 3-2-6 3-2-6 4-0-0 0-9-10 1-3-03-9-53-11-03-9-510.00 12 Plate Offsets (X,Y)-- [5:0-2-0,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-R 0.18 0.08 0.02 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.00 -0.00 0.00 (loc) 1 1 7 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 42 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 6-7: 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins: 5-6. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 4-0-0. (lb) - Max Horz 10=115(LC 5) Max Uplift All uplift 100 lb or less at joint(s) 10, 7 except 9=-121(LC 6) Max Grav All reactions 250 lb or less at joint(s) 10, 7, 9, 8 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(13-14) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Provide adequate drainage to prevent water ponding. 5) Gable requires continuous bottom chord bearing. 6) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 7) Gable studs spaced at 1-4-0 oc. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 10, 7 except (jt=lb) 9=121. 11) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 12) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 13) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 14) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 2,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Shadow_Wood Truss GE05 Truss Type GABLE Qty 1 Ply 1 4 Shadow Wood Job Reference (optional) I38022977 8.220 s Nov 16 2018 MiTek Industries, Inc. Fri Aug 2 10:25:08 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jAXtJ2ozokt8tlXqi1fHBQyGc1j-m96KgMj?FWGRMm2sOuS211GuIsGHbwdXKb7mzLyrw_f Scale: 1/2"=1' Sheet Back Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 6 11 10 9 8 7 2x4 3x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 -0-11-0 0-11-0 6-3-8 6-3-8 0-11-04-0-126.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-R 0.17 0.07 0.03 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.00 0.00 (loc) 1 1 7 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 56 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 6-7: 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 6-3-8. (lb) - Max Horz 11=122(LC 5) Max Uplift All uplift 100 lb or less at joint(s) 11, 7, 8, 9, 10 Max Grav All reactions 250 lb or less at joint(s) 11, 7, 8, 9, 10 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(9-10) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) Gable requires continuous bottom chord bearing. 4) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 5) Gable studs spaced at 1-4-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 11, 7, 8, 9, 10. 8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 2,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Shadow_Wood Truss GE06 Truss Type GABLE Qty 1 Ply 1 4 Shadow Wood Job Reference (optional) I38022978 8.220 s Nov 16 2018 MiTek Industries, Inc. Fri Aug 2 10:25:10 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jAXtJ2ozokt8tlXqi1fHBQyGc1j-iXE451lFn8W9b4CFVJUW6SL7AgrD3cAqovct1Eyrw_d Scale = 1:67.1 Sheet Front Right Option 7-6-0 1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 26 25 24 22 21 20 19 18 17 37 38 39 40 34 36 27 28 29 30 31 32 33 35 23 5x6 5x6 3x6 4x6 3x4 4x6 3x6 3x8 3x6 3x4 2x4 2x4 3x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 3x4 2x4 2x4 6x16 2x4 2x4 2x4 2x4 3x8 2x4 8x8 2x4 2x4 2x4 2x4 7-6-00-1-138-5-9 8-5-9 10-8-9 2-3-0 17-2-7 6-5-14 18-7-8 1-5-1 19-5-7 0-9-15 20-5-0 0-11-9 27-11-0 7-6-0 -0-11-0 0-11-0 5-3-0 5-3-0 9-5-8 4-2-8 10-8-9 1-3-1 17-2-7 6-5-14 22-8-0 5-5-9 27-11-0 5-3-0 28-10-0 0-11-0 1-3-010-0-510-2-21-3-010-0-510.00 12 Plate Offsets (X,Y)-- [5:0-3-0,0-2-1], [10:0-3-0,0-2-1] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-AS 0.59 0.55 0.92 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.14 -0.38 0.03 (loc) 23-25 23-25 17 l/defl >999 >595 n/a L/d 240 180 n/a PLATES MT20 Weight: 351 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 5-10: 2x6 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 17-24: 2x4 SPF 2100F 1.8E WEBS 2x3 SPF No.2 *Except* 2-26,15-17,4-28: 2x4 SPF-S Stud, 27-28: 2x4 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 5-10. BOT CHORD Rigid ceiling directly applied. JOINTS 1 Brace at Jt(s): 29, 31, 33, 36, 38, 40 REACTIONS.All bearings 9-3-8 except (jt=length) 26=0-3-8, 23=0-3-8. (lb) - Max Horz 26=-241(LC 4) Max Uplift All uplift 100 lb or less at joint(s) 26, 17, 20, 19 except 22=-729(LC 2) Max Grav All reactions 250 lb or less at joint(s) 21, 19, 18 except 26=982(LC 10), 17=557(LC 1), 20=264(LC 1), 23=838(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-349/138, 3-4=-892/174, 4-5=-677/175, 5-6=-380/153, 6-7=-387/156, 7-8=-387/156, 8-9=-387/156, 9-10=-375/154, 10-11=-486/181, 11-12=-484/145, 12-13=-539/121, 13-14=-560/111, 2-26=-382/151, 15-17=-305/172 BOT CHORD 25-26=-183/690, 23-25=-139/559, 22-23=-139/559, 21-22=-51/317, 20-21=-51/317, 19-20=-51/329, 18-19=-51/329, 17-18=-51/329 WEBS 22-37=-129/253, 3-26=-724/0, 14-39=-374/104, 39-40=-317/89, 17-40=-317/88, 22-27=-277/47, 25-28=-26/394, 5-28=-26/408, 32-33=-256/63, 14-20=-253/19 NOTES-(11-12) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Provide adequate drainage to prevent water ponding. 5) Gable studs spaced at 1-4-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 26, 17, 20, 19 except (jt=lb) 22=729. 8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. Continued on page 2 August 2,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Shadow_Wood Truss GE06 Truss Type GABLE Qty 1 Ply 1 4 Shadow Wood Job Reference (optional) I38022978 8.220 s Nov 16 2018 MiTek Industries, Inc. Fri Aug 2 10:25:10 2019 Page 2 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jAXtJ2ozokt8tlXqi1fHBQyGc1j-iXE451lFn8W9b4CFVJUW6SL7AgrD3cAqovct1Eyrw_d 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Shadow_Wood Truss J01 Truss Type JACK-CLOSED Qty 38 Ply 1 4 Shadow Wood Job Reference (optional) I38022979 8.220 s Nov 16 2018 MiTek Industries, Inc. Fri Aug 2 10:25:11 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jAXtJ2ozokt8tlXqi1fHBQyGc1j-AkoSJNltYRe0DEnR30?leguOv3H8oHn_0ZLQZgyrw_c Scale = 1:26.0 1 2 3 5 4 2x4 3x4 3x4 2x4 -0-11-0 0-11-0 4-0-0 4-0-0 1-3-04-7-04-3-80-3-84-7-010.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-R 0.21 0.12 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.01 -0.02 0.00 (loc) 4-5 4-5 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 17 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)5=221/0-3-8, 4=139/0-1-8 Max Horz 5=135(LC 5) Max Uplift 5=-12(LC 6), 4=-59(LC 5) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Bearing at joint(s) 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 4) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 4. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 4. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 2,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Shadow_Wood Truss J02 Truss Type HALF HIP Qty 2 Ply 1 4 Shadow Wood Job Reference (optional) I38022980 8.220 s Nov 16 2018 MiTek Industries, Inc. Fri Aug 2 10:25:11 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jAXtJ2ozokt8tlXqi1fHBQyGc1j-AkoSJNltYRe0DEnR30?leguO63HAoHn_0ZLQZgyrw_c Scale = 1:24.6 1 2 3 4 6 5 4x8 2x4 3x4 2x4 0-1-112-0-0 2-0-0 4-0-0 2-0-0 -0-11-0 0-11-0 3-8-2 3-8-2 4-0-0 0-3-14 1-3-04-2-14-3-123-10-90-3-84-2-110.00 12 Plate Offsets (X,Y)-- [3:0-0-0,0-1-7], [3:Edge,0-1-2], [4:0-1-12,0-0-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-R 0.20 0.12 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.01 -0.02 0.00 (loc) 5-6 5-6 5 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 16 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins: 3-4. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)6=221/0-3-8, 5=139/0-1-8 Max Horz 6=127(LC 5) Max Uplift 6=-15(LC 6), 5=-53(LC 5) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(10-11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Bearing at joint(s) 5 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 5. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 6, 5. 8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 2,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Shadow_Wood Truss J03 Truss Type HALF HIP Qty 1 Ply 1 4 Shadow Wood Job Reference (optional) I38022981 8.220 s Nov 16 2018 MiTek Industries, Inc. Fri Aug 2 10:25:12 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jAXtJ2ozokt8tlXqi1fHBQyGc1j-ewMqWjmVJlmtrNLedkX_BtQaPTdUXku7FD5_66yrw_b Scale = 1:19.5 1 2 3 4 7 6 5 4x6 2x4 2x4 2x4 3x4 2x4 0-1-112-5-11 2-5-11 4-0-0 1-6-5 -0-11-0 0-11-0 2-5-11 2-5-11 4-0-0 1-6-5 1-3-03-2-13-3-122-10-90-3-83-2-110.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-R 0.16 0.11 0.01 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.01 -0.02 0.00 (loc) 6 6 5 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 17 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 3-6: 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins: 3-4. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)7=221/0-3-8, 5=139/0-1-8 Max Horz 7=96(LC 5) Max Uplift 7=-27(LC 6), 5=-38(LC 5) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(10-11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Bearing at joint(s) 5 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 5. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 7, 5. 8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 2,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Shadow_Wood Truss J04 Truss Type HALF HIP GIRDER Qty 1 Ply 1 4 Shadow Wood Job Reference (optional) I38022982 8.220 s Nov 16 2018 MiTek Industries, Inc. Fri Aug 2 10:25:13 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jAXtJ2ozokt8tlXqi1fHBQyGc1j-66vDk3n843ukSXwqAR2Dk5zl4tzxGB6HUtqXeZyrw_a Scale = 1:14.4 1 2 3 4 7 6 5 8 9 4x6 2x4 2x4 2x4 2x4 2x4 0-1-51-3-5 1-3-5 4-0-0 2-8-11 -0-11-0 0-11-0 1-3-5 1-3-5 4-0-0 2-8-11 1-3-02-2-72-3-121-10-150-3-82-2-710.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-MR 0.17 0.10 0.01 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.01 -0.01 0.00 (loc) 6 5-6 5 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 15 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 3-6: 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins: 3-4. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)7=223/0-3-8, 5=143/0-1-8 Max Horz 7=68(LC 4) Max Uplift 7=-41(LC 5), 5=-34(LC 4) Max Grav 7=223(LC 1), 5=146(LC 10) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(12-13) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Bearing at joint(s) 5 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 5. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 7, 5. 8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 4 lb down and 11 lb up at 1-3-5, and 8 lb down and 31 lb up at 2-0-12 on top chord, and 4 lb up at 1-3-5, and 8 lb down at 2-0-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 11) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 12) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 13) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 2-3=-60, 3-4=-60, 5-7=-20 Concentrated Loads (lb) Vert: 6=4(B) 8=-4(B) 9=-6(B) August 2,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Shadow_Wood Truss J05 Truss Type JACK-OPEN Qty 1 Ply 1 4 Shadow Wood Job Reference (optional) I38022983 8.220 s Nov 16 2018 MiTek Industries, Inc. Fri Aug 2 10:25:14 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jAXtJ2ozokt8tlXqi1fHBQyGc1j-aJTbxPomrM0b4hV0k9ZSGIWv8HKw?eWQjXa5A?yrw_Z Scale = 1:14.4 1 2 5 3 4 2x4 3x4 2-7-7 2-6-3 -1-6-14 1-6-14 2-7-7 2-7-7 1-1-152-3-71-10-152-3-75.15 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-R 0.21 0.05 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.00 -0.00 (loc) 4-5 4-5 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 9 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 2-7-7 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)3=43/Mechanical, 5=236/0-6-13, 4=17/Mechanical Max Horz 5=49(LC 6) Max Uplift 3=-20(LC 6), 5=-58(LC 6) Max Grav 3=43(LC 1), 5=236(LC 1), 4=43(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8-9) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) Gable studs spaced at 2-0-0 oc. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 5. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 2,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Shadow_Wood Truss J06 Truss Type JACK-OPEN Qty 1 Ply 1 4 Shadow Wood Job Reference (optional) I38022984 8.220 s Nov 16 2018 MiTek Industries, Inc. Fri Aug 2 10:25:14 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jAXtJ2ozokt8tlXqi1fHBQyGc1j-aJTbxPomrM0b4hV0k9ZSGIWwqHJd?eWQjXa5A?yrw_Z Scale = 1:14.5 1 2 5 3 4 2x4 2x4 2-9-8 2-9-8 -0-11-0 0-11-0 2-9-8 2-9-8 0-11-02-3-121-11-12-3-126.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-R 0.17 0.07 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.01 -0.00 (loc) 4-5 4-5 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 9 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 2-9-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)5=180/0-3-8, 3=64/Mechanical, 4=26/Mechanical Max Horz 5=73(LC 6) Max Uplift 5=-23(LC 6), 3=-33(LC 6) Max Grav 5=180(LC 1), 3=64(LC 1), 4=48(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(6-7) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 3. 5) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 2,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Shadow_Wood Truss MG01 Truss Type Monopitch Girder Qty 1 Ply 1 4 Shadow Wood Job Reference (optional) I38022985 8.220 s Nov 16 2018 MiTek Industries, Inc. Fri Aug 2 10:25:15 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jAXtJ2ozokt8tlXqi1fHBQyGc1j-3V1z8lpOcg8Sir4CIs4hpW2_5hUuk5mZxBJeiRyrw_Y Scale = 1:14.5 1 2 3 4 53x4 3x4 2x4 2x4 5-8-8 5-8-8 5-8-8 5-8-8 0-3-141-11-143.50 12 Plate Offsets (X,Y)-- [1:0-3-4,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.58 0.77 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.05 -0.14 0.00 (loc) 1-3 1-3 3 l/defl >999 >454 n/a L/d 240 180 n/a PLATES MT20 Weight: 18 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SPF No.2 WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-8-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 9-8-4 oc bracing. REACTIONS.(lb/size)1=574/0-3-8, 3=484/0-3-8 Max Horz 1=52(LC 4) Max Uplift 1=-39(LC 3), 3=-40(LC 5) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8-9) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 5) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 6) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 310 lb down and 20 lb up at 1-5-12, and 310 lb down and 20 lb up at 3-5-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 1-3=-20 Concentrated Loads (lb) Vert: 4=-310(F) 5=-310(F) August 2,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Shadow_Wood Truss PB01 Truss Type Piggyback Qty 12 Ply 1 4 Shadow Wood Job Reference (optional) I38022986 8.220 s Nov 16 2018 MiTek Industries, Inc. Fri Aug 2 10:25:16 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jAXtJ2ozokt8tlXqi1fHBQyGc1j-XhbLM5p0N_GJJ?fPsabwLjbHd40DTYijAr3BFtyrw_X Scale = 1:12.8 1 2 3 4 5 6 4x6 2x4 2x4 2x4 6-7-0 6-7-0 3-3-8 3-3-8 6-7-0 3-3-8 0-4-31-7-120-1-80-4-30-1-86.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.08 0.06 0.02 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.00 0.00 0.00 (loc) 5 5 4 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 14 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)2=137/4-8-6, 4=137/4-8-6, 6=173/4-8-6 Max Horz 2=18(LC 6) Max Uplift 2=-36(LC 6), 4=-40(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 4. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 2,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Shadow_Wood Truss T02 Truss Type COMMON Qty 2 Ply 1 4 Shadow Wood Job Reference (optional) I38022987 8.220 s Nov 16 2018 MiTek Industries, Inc. Fri Aug 2 10:25:16 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jAXtJ2ozokt8tlXqi1fHBQyGc1j-XhbLM5p0N_GJJ?fPsabwLjb4T4yITXOjAr3BFtyrw_X Scale = 1:43.8 1 2 3 4 5 8 7 6 3x4 3x4 3x8 4x6 6x8 6x8 6-11-8 6-11-8 13-11-0 6-11-8 -0-11-0 0-11-0 6-11-8 6-11-8 13-11-0 6-11-8 14-10-0 0-11-0 1-3-07-0-91-3-010.00 12 Plate Offsets (X,Y)-- [2:0-3-8,Edge], [4:0-3-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-AS 0.92 0.31 0.10 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.04 -0.10 0.01 (loc) 7-8 7-8 6 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 57 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-8,4-6: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals. BOT CHORD Rigid ceiling directly applied. REACTIONS.(lb/size)8=609/0-3-8, 6=609/0-3-8 Max Horz 8=-170(LC 4) Max Uplift 8=-49(LC 6), 6=-49(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-537/88, 3-4=-537/88, 2-8=-545/113, 4-6=-545/113 BOT CHORD 7-8=-211/262 WEBS 3-7=0/272 NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8, 6. 5) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 6) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 2,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Shadow_Wood Truss T03 Truss Type HIP Qty 1 Ply 1 4 Shadow Wood Job Reference (optional) I38022988 8.220 s Nov 16 2018 MiTek Industries, Inc. Fri Aug 2 10:25:17 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jAXtJ2ozokt8tlXqi1fHBQyGc1j-?t9jZRqe8HO9x9EbPH69ux8FNUC3CslsPVolnKyrw_W Scale = 1:52.6 1 2 3 4 5 6 7 8 13 12 11 10 9 4x8 4x8 3x4 2x4 2x4 5x6 5x12 10x10 3x4 3x4 3x6 0-1-130-4-8 0-4-8 7-9-0 7-4-8 7-10-12 0-1-12 8-10-12 1-0-0 12-0-6 3-1-9 21-8-0 9-7-10 -0-11-0 0-11-0 7-9-0 7-9-0 8-10-12 1-1-12 12-0-6 3-1-9 17-2-3 5-1-14 21-8-0 4-5-13 22-7-0 0-11-0 0-10-68-1-99-3-61-3-01-0-09-1-910.00 12 Plate Offsets (X,Y)-- [4:0-4-0,0-1-4], [5:0-4-0,0-1-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-AS 0.91 0.60 0.61 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.19 -0.47 0.02 (loc) 9-10 9-10 9 l/defl >880 >352 n/a L/d 240 180 n/a PLATES MT20 Weight: 102 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 3-11: 2x3 SPF No.2 WEBS 2x3 SPF No.2 *Except* 7-9: 2x4 SPF-S Stud, 2-13: 2x6 SP 2400F 2.0E BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 4-5. BOT CHORD Rigid ceiling directly applied. WEBS 1 Row at midpt 5-10 REACTIONS.(lb/size)13=610/0-3-8, 11=483/0-3-8, 9=742/0-3-8 Max Horz 13=-213(LC 4) Max Uplift 13=-169(LC 6), 11=-3(LC 4), 9=-105(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-532/233, 3-4=-498/397, 4-5=-339/214, 5-6=-543/219, 6-7=-329/68, 7-9=-312/97, 2-13=-541/232 BOT CHORD 12-13=-155/300, 11-12=-478/5, 3-12=-424/285, 9-10=-34/469 WEBS 10-12=-67/375, 4-12=-412/259, 4-10=-125/284, 6-9=-458/135 NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 11 except (jt=lb) 13=169, 9=105. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 2,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Shadow_Wood Truss T03A Truss Type ROOF SPECIAL Qty 2 Ply 1 4 Shadow Wood Job Reference (optional) I38022989 8.220 s Nov 16 2018 MiTek Industries, Inc. Fri Aug 2 10:25:18 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jAXtJ2ozokt8tlXqi1fHBQyGc1j-T4j6nmrGvbW0ZIpnz?eOR8gR4ubcxLp0d9YIJmyrw_V Scale: 3/16"=1' 1 2 3 4 5 6 7 12 11 10 9 8 6x6 4x6 3x6 3x6 8x10 2x4 3x6 3x4 4x10 2x4 5x6 7-3-0 7-3-0 7-4-12 0-1-12 14-10-6 7-5-10 21-2-0 6-3-10 7-3-0 7-3-0 9-11-9 2-8-9 14-10-6 4-10-13 21-2-0 6-3-10 22-1-0 0-11-0 1-3-69-7-010-7-01-3-01-0-010.00 12 Plate Offsets (X,Y)-- [6:0-2-12,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-AS 0.79 0.39 0.49 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.07 -0.18 0.01 (loc) 11-12 11-12 8 l/defl >999 >476 n/a L/d 240 180 n/a PLATES MT20 Weight: 107 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 2-10: 2x3 SPF No.2 WEBS 2x3 SPF No.2 *Except* 3-9: 2x4 SPF No.2, 1-12,6-8: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals. BOT CHORD Rigid ceiling directly applied. WEBS 1 Row at midpt 3-11 REACTIONS.(lb/size)12=330/Mechanical, 10=768/0-3-8, 8=635/0-3-8 Max Horz 12=-261(LC 4) Max Uplift 12=-8(LC 7), 10=-68(LC 6), 8=-60(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 3-5=-572/252, 5-6=-587/75, 1-12=-256/52, 6-8=-579/97 BOT CHORD 11-12=-221/323, 10-11=-700/109, 2-11=-362/242 WEBS 3-11=-274/36, 3-9=-217/503, 5-9=-355/240 NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 12, 10, 8. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 2,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Shadow_Wood Truss T03B Truss Type ROOF SPECIAL Qty 2 Ply 1 4 Shadow Wood Job Reference (optional) I38022990 8.220 s Nov 16 2018 MiTek Industries, Inc. Fri Aug 2 10:25:19 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jAXtJ2ozokt8tlXqi1fHBQyGc1j-xGHU_6sugvetASO_Xi9dzMDcqIxrgo39spHsrCyrw_U Scale: 3/16"=1' 1 2 3 4 5 6 7 12 11 10 9 8 6x6 4x6 3x6 3x6 8x10 2x4 3x6 3x4 4x10 2x4 5x6 7-3-0 7-3-0 7-4-12 0-1-12 14-10-6 7-5-10 21-2-0 6-3-10 7-3-0 7-3-0 9-11-9 2-8-9 14-10-6 4-10-13 21-2-0 6-3-10 22-1-0 0-11-0 1-3-69-7-010-7-01-3-01-0-010.00 12 Plate Offsets (X,Y)-- [6:0-2-12,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-AS 0.79 0.39 0.49 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.07 -0.18 0.01 (loc) 11-12 11-12 8 l/defl >999 >476 n/a L/d 240 180 n/a PLATES MT20 Weight: 107 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 2-10: 2x3 SPF No.2 WEBS 2x3 SPF No.2 *Except* 3-9: 2x4 SPF No.2, 1-12,6-8: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals. BOT CHORD Rigid ceiling directly applied. WEBS 1 Row at midpt 3-11 REACTIONS.(lb/size)12=330/0-1-8, 10=768/0-3-8, 8=635/0-3-8 Max Horz 12=-261(LC 4) Max Uplift 12=-8(LC 7), 10=-68(LC 6), 8=-60(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 3-5=-572/252, 5-6=-587/75, 1-12=-256/52, 6-8=-579/97 BOT CHORD 11-12=-221/323, 10-11=-700/109, 2-11=-362/242 WEBS 3-11=-274/36, 3-9=-217/503, 5-9=-355/240 NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 12. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 12, 10, 8. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 2,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Shadow_Wood Truss T05 Truss Type HIP Qty 1 Ply 1 4 Shadow Wood Job Reference (optional) I38022991 8.220 s Nov 16 2018 MiTek Industries, Inc. Fri Aug 2 10:25:20 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jAXtJ2ozokt8tlXqi1fHBQyGc1j-PSrsCSsXRCmkoczA5PgsWZmqliDVPEmI5T1POfyrw_T Scale: 3/16"=1' 1 2 3 4 5 6 7 8 9 10 15 14 13 12 11 3x8 5x6 5x6 3x8 3x6 3x4 3x4 3x4 3x4 3x6 3x8 3x8 3x6 0-1-138-5-9 8-5-9 19-5-7 10-11-14 27-11-0 8-5-9 -0-11-0 0-11-0 5-3-0 5-3-0 12-4-2 7-1-3 15-6-14 3-2-12 22-8-0 7-1-3 27-11-0 5-3-0 28-10-0 0-11-0 1-3-011-4-1011-6-71-3-011-4-1010.00 12 Plate Offsets (X,Y)-- [5:0-3-0,0-2-1], [6:0-3-0,0-2-1] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-AS 0.59 0.68 0.53 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.26 -0.69 0.05 (loc) 12-14 12-14 11 l/defl >999 >478 n/a L/d 240 180 n/a PLATES MT20 Weight: 126 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 5-6: 2x6 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-15,9-11: 2x4 SPF-S Stud, 5-14,6-12: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 5-6. BOT CHORD Rigid ceiling directly applied. WEBS 1 Row at midpt 3-15, 8-11 REACTIONS.(lb/size)15=1169/0-3-8, 11=1169/0-3-8 Max Horz 15=273(LC 5) Max Uplift 15=-67(LC 6), 11=-67(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-286/111, 3-5=-1180/226, 5-6=-680/225, 6-8=-1180/226, 8-9=-286/111, 2-15=-325/123, 9-11=-325/123 BOT CHORD 14-15=-117/897, 12-14=-9/680, 11-12=0/897 WEBS 3-15=-1071/37, 8-11=-1071/37, 5-14=-67/448, 6-12=-67/448 NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 15, 11. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 2,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Shadow_Wood Truss T05A Truss Type COMMON Qty 2 Ply 1 4 Shadow Wood Job Reference (optional) I38022992 8.220 s Nov 16 2018 MiTek Industries, Inc. Fri Aug 2 10:25:21 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jAXtJ2ozokt8tlXqi1fHBQyGc1j-tfOEPot9CWvbQmYMe7B52nI?f5Zk8gTSK7myw5yrw_S Scale = 1:77.9 1 2 3 4 5 6 7 8 9 14 13 12 11 10 3x8 4x8 3x8 3x6 3x4 3x4 3x4 3x4 3x4 3x8 3x8 3x4 8-5-9 8-5-9 19-5-7 10-11-14 27-11-0 8-5-9 -0-11-0 0-11-0 5-3-2 5-3-2 13-11-8 8-8-6 22-7-14 8-8-6 27-11-0 5-3-2 28-10-0 0-11-0 1-3-012-10-91-3-010.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-AS 0.64 0.68 0.56 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.27 -0.70 0.04 (loc) 11-13 11-13 10 l/defl >999 >471 n/a L/d 240 180 n/a PLATES MT20 Weight: 130 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 5-11,5-13: 2x4 SPF No.2, 2-14,8-10: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals. BOT CHORD Rigid ceiling directly applied. WEBS 1 Row at midpt 5-11, 5-13, 3-14, 7-10 REACTIONS.(lb/size)14=1169/0-3-8, 10=1169/0-3-8 Max Horz 14=306(LC 5) Max Uplift 14=-69(LC 6), 10=-69(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 3-5=-1201/246, 5-7=-1201/246, 2-14=-277/95, 8-10=-277/95 BOT CHORD 13-14=-98/915, 11-13=0/620, 10-11=0/915 WEBS 5-11=-94/481, 7-11=-263/252, 5-13=-94/481, 3-13=-263/251, 3-14=-1137/71, 7-10=-1137/71 NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 14, 10. 5) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 6) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 2,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Shadow_Wood Truss T06 Truss Type COMMON Qty 3 Ply 1 4 Shadow Wood Job Reference (optional) I38022993 8.220 s Nov 16 2018 MiTek Industries, Inc. Fri Aug 2 10:25:22 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jAXtJ2ozokt8tlXqi1fHBQyGc1j-Lrycc8unyq1S1w6ZCqiKb_r9GVvyt7jbYnWWSXyrw_R Scale = 1:77.9 1 2 3 4 5 6 7 8 13 12 11 10 9 3x8 4x8 3x8 3x6 3x4 3x4 3x4 3x4 3x4 3x8 3x8 3x4 8-5-9 8-5-9 19-5-7 10-11-14 27-11-0 8-5-9 -0-11-0 0-11-0 5-3-2 5-3-2 13-11-8 8-8-6 22-7-14 8-8-6 27-11-0 5-3-2 1-3-012-10-91-3-010.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-AS 0.65 0.68 0.56 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.27 -0.70 0.04 (loc) 10-12 10-12 9 l/defl >999 >470 n/a L/d 240 180 n/a PLATES MT20 Weight: 128 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 5-10,5-12: 2x4 SPF No.2, 2-13,8-9: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals. BOT CHORD Rigid ceiling directly applied. WEBS 1 Row at midpt 5-10, 5-12, 3-13, 7-9 REACTIONS.(lb/size)13=1170/0-3-8, 9=1104/0-3-8 Max Horz 13=316(LC 5) Max Uplift 13=-69(LC 6), 9=-36(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 3-5=-1202/246, 5-7=-1206/246, 2-13=-277/95 BOT CHORD 12-13=-110/916, 10-12=0/621, 9-10=-27/921 WEBS 5-10=-94/483, 7-10=-269/252, 5-12=-94/481, 3-12=-263/252, 3-13=-1139/71, 7-9=-1133/86 NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 13, 9. 5) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 6) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 2,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Shadow_Wood Truss T06A Truss Type COMMON Qty 3 Ply 1 4 Shadow Wood Job Reference (optional) I38022994 8.220 s Nov 16 2018 MiTek Industries, Inc. Fri Aug 2 10:25:22 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jAXtJ2ozokt8tlXqi1fHBQyGc1j-Lrycc8unyq1S1w6ZCqiKb_r99Vt1t9LbYnWWSXyrw_R Scale = 1:82.1 1 2 3 4 5 6 11 10 9 8 7 3x8 4x8 5x8 3x6 3x4 3x4 2x4 3x8 3x4 3x6 8-5-8 8-5-8 19-5-6 10-11-14 20-11-0 1-5-10 -0-11-0 0-11-0 5-3-1 5-3-1 13-11-8 8-8-7 20-11-0 6-11-8 1-3-012-10-97-1-010.00 12 Plate Offsets (X,Y)-- [6:0-3-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-AS 0.66 0.80 0.39 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.26 -0.68 0.02 (loc) 8-10 8-10 7 l/defl >941 >363 n/a L/d 240 180 n/a PLATES MT20 Weight: 111 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 5-10,5-8: 2x4 SPF No.2, 2-11,6-7: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals. BOT CHORD Rigid ceiling directly applied. WEBS 1 Row at midpt 5-10, 3-11, 6-7, 5-8 REACTIONS.(lb/size)11=890/0-3-8, 7=823/0-3-8 Max Horz 11=388(LC 5) Max Uplift 11=-51(LC 6), 7=-60(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 3-5=-827/219, 5-6=-285/218, 6-7=-923/30 BOT CHORD 10-11=-207/651, 8-10=-100/310 WEBS 3-10=-293/257, 5-10=-98/516, 3-11=-799/50, 5-8=-439/155, 6-8=0/722 NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 11, 7. 5) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 6) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 2,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Shadow_Wood Truss T07 Truss Type HIP Qty 1 Ply 1 4 Shadow Wood Job Reference (optional) I38022995 8.220 s Nov 16 2018 MiTek Industries, Inc. Fri Aug 2 10:25:23 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jAXtJ2ozokt8tlXqi1fHBQyGc1j-q1W_qUvPj79Jf4hlmYDZ8CNKSvDgcVQlnQF3__yrw_Q Scale = 1:82.6 1 2 3 4 5 6 7 8 9 10 18 17 16 15 14 13 12 11 6x6 5x6 3x6 3x4 3x8 MT18HS5x12 4x6 4x6 3x6 3x6 3x6 4x8 3x8 10x10 5x6 3x16 MT18HS0-1-155-4-8 5-4-8 15-2-13 9-10-5 25-1-3 9-10-5 34-11-8 9-10-5 45-7-8 10-8-0 5-4-8 5-4-8 12-9-4 7-4-12 20-2-0 7-4-12 27-6-12 7-4-12 34-11-8 7-4-12 40-1-2 5-1-10 45-7-8 5-6-6 46-6-8 0-11-0 3-6-126-1-16-3-00-11-06-1-16.00 12 Plate Offsets (X,Y)-- [9:0-2-12,0-1-6], [11:Edge,0-3-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-AS 0.68 0.78 0.85 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.26 -0.75 0.21 (loc) 14 14-15 11 l/defl >999 >723 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 178 lb FT = 20% GRIP 169/123 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF 2100F 1.8E *Except* 16-18: 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 3-17,6-12: 2x4 SPF No.2, 1-18: 2x4 SPF-S Stud, 9-11: 2x6 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals, and 2-0-0 oc purlins (2-6-5 max.): 2-7. BOT CHORD Rigid ceiling directly applied. WEBS 1 Row at midpt 3-17, 6-12, 8-11 REACTIONS.(lb/size)18=1809/0-3-8, 11=1880/0-3-8 Max Horz 18=-136(LC 4) Max Uplift 18=-67(LC 5), 11=-62(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-1683/220, 2-3=-1458/231, 3-4=-3153/378, 4-6=-3501/421, 6-7=-2519/340, 7-8=-2873/345, 8-9=-737/77, 1-18=-1776/205, 9-11=-557/138 BOT CHORD 15-17=-181/2886, 14-15=-238/3511, 12-14=-228/3413, 11-12=-217/2485 WEBS 2-17=0/421, 3-17=-1836/203, 3-15=0/693, 4-15=-567/126, 6-14=0/334, 6-12=-1213/179, 7-12=-22/865, 1-17=-112/1713, 8-11=-2262/303 NOTES-(10-11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 18, 11. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 2,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Shadow_Wood Truss T08 Truss Type HIP Qty 1 Ply 1 4 Shadow Wood Job Reference (optional) I38022996 8.220 s Nov 16 2018 MiTek Industries, Inc. Fri Aug 2 10:25:24 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jAXtJ2ozokt8tlXqi1fHBQyGc1j-IE4N1qv1URHAHEGxKFkogPwUQJVsLxpu04?cXQyrw_P Scale = 1:83.9 1 2 3 4 5 6 7 8 9 10 11 12 23 22 21 20 19 18 17 16 15 14 13 6x8 5x8 3x6 3x6 3x6 3x6 3x8 3x4 3x4 3x8 3x8 6x16 6x8 10x10 5x12 10x10 5x6 3x6 4x8 10x10 5x6 0-1-158-8-8 8-8-8 18-10-8 10-2-0 19-11-0 1-0-8 31-7-8 11-8-8 38-5-15 6-10-7 45-7-8 7-1-9 8-8-8 8-8-8 14-0-1 5-3-9 18-10-8 4-10-7 19-11-0 1-0-8 26-4-0 6-5-0 31-7-8 5-3-9 38-5-15 6-10-7 45-7-8 7-1-9 46-6-8 0-11-0 3-6-127-9-17-11-00-11-03-0-07-9-16.00 12 Plate Offsets (X,Y)-- [1:Edge,0-1-12], [2:0-4-2,Edge], [13:0-5-0,0-2-4], [13:0-2-7,0-1-4], [14:0-2-8,0-2-0], [16:0-4-8,0-2-0], [18:0-6-8,0-6-8], [19:0-6-4,0-6-0], [20:0-3-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-AS 0.73 0.97 0.91 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.52 -1.54 0.43 (loc) 16-17 16-17 13 l/defl >999 >354 n/a L/d 240 180 n/a PLATES MT20 Weight: 216 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 4-8: 2x4 SPF 2100F 1.8E BOT CHORD 2x4 SPF No.2 *Except* 5-20,6-17: 2x3 SPF No.2, 18-19: 2x6 SPF No.2 15-17: 2x4 SPF 2100F 1.8E WEBS 2x3 SPF No.2 *Except* 3-22,19-22,16-18,7-16,1-23: 2x4 SPF No.2, 11-13: 2x6 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals, and 2-0-0 oc purlins (2-3-14 max.): 2-8. BOT CHORD Rigid ceiling directly applied. WEBS 1 Row at midpt 3-22, 7-16 REACTIONS.(lb/size)23=1809/0-3-8, 13=1880/0-3-8 Max Horz 23=-152(LC 4) Max Uplift 23=-12(LC 6), 13=-82(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-2038/274, 2-3=-1734/295, 3-5=-4826/505, 5-6=-4845/507, 6-7=-4868/512, 7-8=-2361/360, 8-10=-2701/360, 10-11=-2985/362, 1-23=-1732/238, 11-13=-1793/292 BOT CHORD 5-19=-290/74, 18-19=-228/4846, 14-16=-200/2580, 13-14=-55/579 WEBS 2-22=0/535, 3-22=-2258/200, 19-22=-156/3142, 3-19=-127/2383, 16-18=-212/3379, 7-18=-81/1840, 7-16=-1709/203, 8-16=-33/820, 10-16=-284/141, 1-22=-90/1744, 11-14=-147/2011 NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 23, 13. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 2,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Shadow_Wood Truss T09 Truss Type HIP Qty 1 Ply 1 4 Shadow Wood Job Reference (optional) I38022997 8.220 s Nov 16 2018 MiTek Industries, Inc. Fri Aug 2 10:25:26 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jAXtJ2ozokt8tlXqi1fHBQyGc1j-EcC7SWxH02XuWXQKRgnGlq?nF6E4ptCBTOUjbIyrw_N Scale = 1:83.5 1 2 3 4 5 6 7 8 9 10 11 12 25 24 23 22 21 20 19 18 17 16 15 14 13 5x8 6x10 3x8 3x6 3x6 3x6 3x4 3x4 3x4 3x6 3x6 3x6 3x8 5x12 8x10 8x10 5x12 5x12 3x6 4x8 3x6 10x10 3x6 0-1-157-10-2 7-10-2 12-0-8 4-2-6 18-10-8 6-10-0 19-11-0 1-0-8 28-3-8 8-4-8 32-5-14 4-2-6 36-10-4 4-4-6 38-7-2 1-8-14 45-7-8 7-0-6 7-10-2 7-10-2 12-0-8 4-2-6 18-10-8 6-10-0 19-11-0 1-0-8 28-3-8 8-4-8 32-5-14 4-2-6 38-7-2 6-1-4 45-7-8 7-0-6 46-6-8 0-11-0 3-6-129-5-19-7-00-11-03-0-09-5-16.00 12 Plate Offsets (X,Y)-- [1:0-3-0,0-1-8], [3:0-6-2,Edge], [7:0-6-0,0-0-15], [13:0-5-0,0-2-4], [13:0-2-7,0-1-4], [14:0-2-8,0-2-0], [16:0-2-8,0-1-8], [19:0-6-12,0-5-0], [20:0-6-4,0-4-8], [21:Edge,0-2-8], [23:0-2-8,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-AS 0.90 0.80 0.79 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.29 -0.83 0.34 (loc) 19 17-18 13 l/defl >999 >654 n/a L/d 240 180 n/a PLATES MT20 Weight: 216 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 3-6,6-7: 2x4 SPF 2100F 1.8E BOT CHORD 2x4 SPF No.2 *Except* 4-21,5-18: 2x3 SPF No.2, 19-20: 2x6 SPF No.2 WEBS 2x3 SPF No.2 *Except* 1-25: 2x4 SPF-S Stud, 11-13: 2x6 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals, and 2-0-0 oc purlins (3-1-4 max.): 3-7. BOT CHORD Rigid ceiling directly applied. WEBS 1 Row at midpt 3-22, 7-17, 8-17, 1-25 REACTIONS.(lb/size)25=1809/0-3-8, 13=1880/0-3-8 Max Horz 25=-168(LC 4) Max Uplift 25=-33(LC 6), 13=-100(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-1947/286, 2-3=-2002/361, 3-4=-3486/435, 4-5=-3495/434, 5-7=-3517/441, 7-8=-2408/399, 8-10=-2703/394, 10-11=-2988/367, 1-25=-1729/249, 11-13=-1798/296 BOT CHORD 22-23=-37/1653, 4-20=-391/91, 19-20=-99/3496, 5-19=-333/131, 16-17=-117/2342, 14-16=-203/2580, 13-14=-75/582 WEBS 2-23=-569/129, 2-22=-64/324, 3-22=-914/47, 20-22=-16/1939, 3-20=-126/2293, 17-19=-60/2231, 7-19=-86/1692, 7-17=-410/140, 8-17=-433/141, 1-23=-129/1718, 8-16=-19/274, 10-16=-303/104, 11-14=-129/2009 NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 25, 13. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 2,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Shadow_Wood Truss T10 Truss Type HIP Qty 1 Ply 1 4 Shadow Wood Job Reference (optional) I38022998 8.220 s Nov 16 2018 MiTek Industries, Inc. Fri Aug 2 10:25:27 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jAXtJ2ozokt8tlXqi1fHBQyGc1j-ipmVgrywnMfl8h?W?OIVI2Y_LWYlYMvKi2DH8lyrw_M Scale = 1:82.1 1 2 3 4 5 6 7 8 9 10 11 20 19 18 17 16 15 14 13 12 3x6 5x6 5x6 3x6 3x6 3x6 3x8 3x6 3x8 3x6 3x8 3x6 3x6 3x6 4x8 5x6 10x10 3x6 0-1-157-11-6 7-11-6 15-4-8 7-5-2 24-11-8 9-7-0 32-4-10 7-5-2 33-0-3 0-7-9 38-5-15 5-5-11 45-7-8 7-1-9 7-11-6 7-11-6 15-4-8 7-5-2 20-2-0 4-9-8 24-11-8 4-9-8 32-4-10 7-5-2 38-5-15 6-1-4 45-7-8 7-1-9 46-6-8 0-11-0 3-6-1211-1-111-3-00-11-011-1-16.00 12 Plate Offsets (X,Y)-- [1:Edge,0-1-12], [12:0-2-7,0-1-4], [12:0-5-0,0-2-4], [13:0-2-8,0-2-0], [14:0-2-8,0-1-8], [19:0-2-8,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-AS 0.82 0.96 0.69 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.25 -0.73 0.14 (loc) 16-17 16-17 12 l/defl >999 >747 n/a L/d 240 180 n/a PLATES MT20 Weight: 213 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 4-17,5-17,5-16,6-16: 2x4 SPF No.2, 1-20: 2x4 SPF-S Stud 10-12: 2x6 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals, and 2-0-0 oc purlins (3-11-2 max.): 4-6. BOT CHORD Rigid ceiling directly applied. WEBS 1 Row at midpt 2-17, 5-17, 5-16, 7-16, 1-20 REACTIONS.(lb/size)20=1809/0-3-8, 12=1880/0-3-8 Max Horz 20=-184(LC 4) Max Uplift 20=-52(LC 6), 12=-115(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-1957/300, 2-4=-2015/373, 4-5=-1704/373, 5-6=-1896/397, 6-7=-2222/396, 7-9=-2718/410, 9-10=-2979/378, 1-20=-1732/258, 10-12=-1797/304 BOT CHORD 17-19=-53/1668, 16-17=-10/1868, 14-16=-138/2368, 13-14=-212/2568, 12-13=-84/607 WEBS 2-19=-548/151, 4-17=-33/527, 5-17=-527/93, 6-16=-34/596, 7-16=-662/187, 7-14=0/355, 9-14=-264/90, 1-19=-150/1742, 10-13=-128/1972 NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 20 except (jt=lb) 12=115. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 2,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Shadow_Wood Truss T11 Truss Type HIP Qty 1 Ply 1 4 Shadow Wood Job Reference (optional) I38022999 8.220 s Nov 16 2018 MiTek Industries, Inc. Fri Aug 2 10:25:28 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jAXtJ2ozokt8tlXqi1fHBQyGc1j-A?JttBzYYgnclraiZ5plqF5CxwuaHphUxizqgByrw_L Scale = 1:83.4 1 2 3 4 5 6 7 8 9 10 11 20 19 18 17 16 15 14 13 12 3x6 5x6 5x12 3x8 3x8 MT18HS3x6 4x6 3x6 3x8 3x6 3x6 3x6 3x6 4x8 3x4 4x6 10x10 3x8 0-1-157-3-12 7-3-12 18-8-8 11-4-13 21-7-8 2-11-0 33-0-6 11-4-14 39-2-13 6-2-7 45-7-8 6-4-11 3-0-11 3-0-11 6-4-8 3-3-13 11-9-9 5-5-1 18-8-8 6-10-15 21-7-8 2-11-0 28-6-7 6-10-15 37-3-5 8-8-14 45-7-8 8-4-3 46-6-8 0-11-0 3-6-1212-9-112-11-00-11-012-9-16.00 12 Plate Offsets (X,Y)-- [6:0-6-0,0-0-15], [12:0-2-7,0-1-4], [12:0-5-0,0-2-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-AS 0.64 0.92 0.66 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.34 -0.97 0.13 (loc) 14-16 14-16 12 l/defl >999 >563 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 222 lb FT = 20% GRIP 169/123 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF 2100F 1.8E *Except* 18-20: 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 4-17,5-17,6-17,6-16,7-16: 2x4 SPF No.2, 1-20: 2x4 SPF-S Stud 10-12: 2x6 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals, and 2-0-0 oc purlins (4-4-15 max.): 5-6. BOT CHORD Rigid ceiling directly applied. WEBS 1 Row at midpt 4-19, 4-17, 6-17, 7-16, 2-20 REACTIONS.(lb/size)20=1809/0-3-8, 12=1880/0-3-8 Max Horz 20=-201(LC 4) Max Uplift 20=-67(LC 6), 12=-127(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-1864/327, 4-5=-1896/409, 5-6=-1600/399, 6-7=-1952/416, 7-9=-2736/444, 9-10=-2922/388, 10-12=-1793/310 BOT CHORD 19-20=-86/1078, 17-19=-55/1736, 16-17=0/1648, 14-16=-102/2113, 13-14=-240/2576, 12-13=-114/647 WEBS 2-19=0/735, 4-19=-384/97, 4-17=-304/184, 5-17=-84/526, 6-17=-382/79, 6-16=-113/760, 7-16=-780/246, 7-14=-26/573, 9-14=-373/190, 2-20=-2055/283, 10-13=-98/1880 NOTES-(10-11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 20 except (jt=lb) 12=127. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 2,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Shadow_Wood Truss T12 Truss Type PIGGYBACK BASE Qty 1 Ply 1 4 Shadow Wood Job Reference (optional) I38023000 8.220 s Nov 16 2018 MiTek Industries, Inc. Fri Aug 2 10:25:29 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jAXtJ2ozokt8tlXqi1fHBQyGc1j-eBtG4XzAJzvTN?9v6oK_NTdMpKEZ0Grd9MiNCdyrw_K Scale = 1:81.5 1 2 3 4 5 6 7 8 9 10 11 20 19 18 17 16 15 14 13 12 3x12 5x6 5x8 3x12 3x8 3x6 4x6 3x6 3x8 3x6 3x6 3x6 3x6 4x8 3x4 4x6 10x10 3x8 7-3-11 7-3-11 16-10-8 9-6-13 23-5-8 6-7-0 33-0-4 9-6-12 39-2-13 6-2-8 45-7-8 6-4-11 3-0-10 3-0-10 11-9-9 8-8-15 16-10-8 5-0-15 23-5-8 6-7-0 28-6-7 5-0-15 37-3-8 8-9-0 45-7-8 8-4-0 46-6-8 0-11-0 3-6-1212-0-00-11-012-0-06.00 12 Plate Offsets (X,Y)-- [5:0-3-8,0-2-4], [6:0-5-8,0-2-4], [12:0-2-7,0-1-4], [12:0-5-0,0-2-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-AS 0.69 0.94 0.67 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.27 -0.79 0.15 (loc) 14-16 14-16 12 l/defl >999 >688 n/a L/d 240 180 n/a PLATES MT20 Weight: 218 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 4-17,5-17,6-17,6-16,7-16: 2x4 SPF No.2, 1-20: 2x4 SPF-S Stud 10-12: 2x6 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals, and 2-0-0 oc purlins (3-11-2 max.): 5-6. BOT CHORD Rigid ceiling directly applied. WEBS 1 Row at midpt 4-19, 4-17, 6-17, 7-16, 2-20 REACTIONS.(lb/size)20=1809/0-3-8, 12=1880/0-3-8 Max Horz 20=-193(LC 4) Max Uplift 20=-59(LC 6), 12=-120(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-1860/325, 4-5=-1926/406, 5-6=-1653/386, 6-7=-2049/421, 7-9=-2729/440, 9-10=-2931/380, 10-12=-1800/305 BOT CHORD 19-20=-76/1082, 17-19=-43/1730, 16-17=0/1767, 14-16=-90/2107, 13-14=-237/2581, 12-13=-107/599 WEBS 2-19=0/717, 4-19=-389/79, 5-17=-74/518, 6-17=-380/67, 6-16=-103/777, 7-16=-713/229, 7-14=-43/535, 9-14=-392/192, 2-20=-2060/288, 10-13=-99/1938 NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 20 except (jt=lb) 12=120. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 2,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Shadow_Wood Truss T13 Truss Type PIGGYBACK BASE Qty 1 Ply 1 4 Shadow Wood Job Reference (optional) I38023001 8.220 s Nov 16 2018 MiTek Industries, Inc. Fri Aug 2 10:25:30 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jAXtJ2ozokt8tlXqi1fHBQyGc1j-6OReIt_o4H1J?9k5gWrDwgAWpkZ4lfhnO0Sxk4yrw_J Scale = 1:93.0 1 2 3 4 5 6 7 8 9 10 11 24 23 22 21 17 16 15 14 13 12 20 19 18 25 26 3x12 5x8 3x12 3x6 2x4 5x12 4x6 3x6 2x4 5x12 3x6 4x10 3x6 4x8 5x6 3x4 10x10 3x6 2x4 2x4 5x12 5x12 7-3-11 7-3-11 16-8-8 9-4-13 16-10-8 0-2-0 18-7-0 1-8-8 23-5-8 4-10-8 33-0-4 9-6-12 39-2-13 6-2-8 45-7-8 6-4-11 3-0-10 3-0-10 11-9-9 8-8-15 16-8-8 4-10-15 16-10-8 0-2-0 23-5-8 6-7-0 28-6-7 5-0-15 37-3-8 8-9-0 45-7-8 8-4-0 46-6-8 0-11-0 3-6-1212-0-00-11-03-0-012-0-06.00 12 Plate Offsets (X,Y)-- [6:0-5-0,0-2-0], [12:0-5-0,0-2-4], [12:0-2-7,0-1-4], [14:0-4-0,0-2-0], [18:0-4-12,0-2-4], [20:0-8-0,0-3-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-AS 0.74 0.92 0.95 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.29 -0.86 0.35 (loc) 21-23 21-23 12 l/defl >999 >633 n/a L/d 240 180 n/a PLATES MT20 Weight: 241 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 4-23,6-16,7-14,5-21: 2x4 SPF No.2, 1-24: 2x4 SPF-S Stud 10-12,5-18: 2x6 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals, and 2-0-0 oc purlins (2-10-13 max.): 5-6. BOT CHORD Rigid ceiling directly applied. WEBS 1 Row at midpt 4-23, 7-14, 2-24, 5-18 JOINTS 1 Brace at Jt(s): 18 REACTIONS.(lb/size)24=1936/0-3-8, 12=1968/0-3-8 Max Horz 24=-193(LC 4) Max Uplift 24=-59(LC 6), 12=-120(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-2024/323, 4-5=-2903/405, 5-6=-2596/391, 6-7=-2946/408, 7-9=-2895/438, 9-10=-3093/379, 10-12=-1888/304 BOT CHORD 23-24=-76/1160, 13-14=-237/2731, 12-13=-108/607, 19-20=0/2506, 18-19=0/2494 WEBS 2-23=0/802, 4-23=-1307/107, 16-18=0/331, 6-18=-72/964, 7-14=-409/50, 9-14=-386/191, 2-24=-2210/288, 10-13=-96/2075, 20-23=-55/2387, 4-20=0/539, 14-18=-115/2758, 5-20=-60/810, 5-18=-73/346 NOTES-(10-11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 24 except (jt=lb) 12=120. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 2,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Shadow_Wood Truss T14 Truss Type PIGGYBACK BASE Qty 1 Ply 1 4 Shadow Wood Job Reference (optional) I38023002 8.220 s Nov 16 2018 MiTek Industries, Inc. Fri Aug 2 10:25:31 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jAXtJ2ozokt8tlXqi1fHBQyGc1j-ba?0VD?Qrb9AcIIHEDMSSujeN7wHU7CwdgBUHWyrw_I Scale = 1:83.4 1 2 3 4 5 6 7 8 9 10 11 23 22 21 20 16 15 14 13 12 19 18 17 24 3x12 5x8 3x8 3x6 2x4 5x12 4x6 3x6 5x12 5x8 5x12 6x8 4x8 5x6 3x4 10x10 2x4 3x8 5x12 4x6 4x8 12-3-0 7-3-11 7-3-11 16-8-8 9-4-13 16-10-8 0-2-0 23-5-8 6-7-0 28-11-8 5-6-0 33-0-4 4-0-12 39-2-13 6-2-8 45-7-8 6-4-11 3-0-10 3-0-10 11-9-9 8-8-15 16-8-8 4-10-15 16-10-8 0-2-0 23-5-8 6-7-0 28-6-7 5-0-15 28-11-8 0-5-1 37-3-8 8-4-0 45-7-8 8-4-0 46-6-8 0-11-0 3-6-1212-0-00-11-03-0-012-0-06.00 12 Plate Offsets (X,Y)-- [6:0-4-8,0-1-12], [12:0-5-0,0-2-4], [12:0-2-7,0-1-4], [17:0-7-0,Edge], [19:0-6-12,0-2-12] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-AS 0.94 0.86 0.87 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.34 -0.89 0.42 (loc) 18-19 20-22 12 l/defl >999 >612 n/a L/d 240 180 n/a PLATES MT20 Weight: 228 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 17-19: 2x4 SPF 2100F 1.8E WEBS 2x3 SPF No.2 *Except* 4-22,5-20,7-16: 2x4 SPF No.2, 1-23: 2x4 SPF-S Stud 10-12,5-18: 2x6 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals, and 2-0-0 oc purlins (3-0-1 max.): 5-6. BOT CHORD Rigid ceiling directly applied. WEBS 1 Row at midpt 4-22, 9-15, 2-23, 7-18, 5-18 REACTIONS.(lb/size)23=1898/0-3-8, 12=1940/0-3-8 Max Horz 23=-193(LC 4) Max Uplift 23=-59(LC 6), 12=-120(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-1981/323, 4-5=-2785/405, 5-6=-2535/395, 6-7=-2907/409, 7-9=-4012/468, 9-10=-3042/374, 10-12=-1862/302 BOT CHORD 22-23=-76/1137, 13-15=-235/2677, 12-13=-119/612, 18-19=0/2393, 17-18=-142/3495 WEBS 2-22=0/778, 4-22=-1230/107, 4-19=0/494, 15-17=-129/2061, 9-15=-1561/198, 2-23=-2166/288, 10-13=-81/2024, 5-19=-58/711, 7-17=-36/1044, 9-17=-39/1893, 7-18=-1385/243, 6-18=-59/910, 5-18=-65/402, 19-22=-55/2302 NOTES-(10-11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 23 except (jt=lb) 12=120. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 2,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Shadow_Wood Truss T15 Truss Type PIGGYBACK BASE Qty 3 Ply 1 4 Shadow Wood Job Reference (optional) I38023003 8.220 s Nov 16 2018 MiTek Industries, Inc. Fri Aug 2 10:25:32 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jAXtJ2ozokt8tlXqi1fHBQyGc1j-3mZOjZ02cuH1EStUoxuh?5Fr9XEYDbL4rKx2pyyrw_H Scale = 1:89.7 1 2 3 4 5 6 7 8 9 10 11 22 21 20 19 18 17 16 15 14 13 12 5x8 5x12 5x8 3x12 3x4 3x8 MT18HS 6x16 2x4 3x6 3x6 3x6 3x8 3x6 3x6 3x6 4x8 6x8 10x10 3x8 MT18HS3x8 MT18HS 4-1-12 4-1-12 5-9-10 1-7-14 12-7-9 6-9-15 22-2-0 9-6-7 28-9-0 6-7-0 38-3-14 9-6-14 44-6-5 6-2-7 50-11-0 6-4-11 4-1-12 4-1-12 9-6-8 5-4-12 17-1-4 7-6-12 22-2-0 5-0-12 28-9-0 6-7-0 33-9-15 5-0-15 42-7-0 8-9-0 50-11-0 8-4-0 51-10-0 0-11-0 2-10-145-8-412-0-00-11-012-0-03.50 12 6.00 12 Plate Offsets (X,Y)-- [5:0-8-8,0-1-12], [6:0-5-0,0-2-0], [12:0-2-7,0-1-4], [12:0-5-0,0-2-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-AS 0.81 0.98 0.81 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.30 -0.90 0.22 (loc) 14-16 14-16 12 l/defl >999 >671 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 238 lb FT = 20% GRIP 169/123 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-21,1-22: 2x4 SPF-S Stud, 4-17,5-17,5-16,6-16,7-16: 2x4 SPF No.2 10-12: 2x6 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals, and 2-0-0 oc purlins (3-4-1 max.): 5-6. BOT CHORD Rigid ceiling directly applied. WEBS 1 Row at midpt 3-21, 4-17, 5-16, 7-16 REACTIONS.(lb/size)22=2021/0-3-8, 12=2091/0-3-8 Max Horz 22=-139(LC 7) Max Uplift 22=-86(LC 6), 12=-121(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-2106/288, 2-3=-2118/338, 3-4=-3149/495, 4-5=-2491/475, 5-6=-2164/450, 6-7=-2493/476, 7-9=-3152/492, 9-10=-3313/427, 1-22=-1988/259, 10-12=-2009/331 BOT CHORD 19-21=-245/2890, 17-19=-136/2500, 16-17=-27/2166, 14-16=-138/2497, 13-14=-281/2938, 12-13=-111/632 WEBS 2-21=-284/121, 3-21=-1268/153, 3-19=-342/182, 4-19=-44/549, 4-17=-707/221, 5-17=-101/767, 6-16=-103/763, 7-16=-703/227, 7-14=-40/515, 9-14=-370/188, 1-21=-254/2355, 10-13=-137/2249 NOTES-(10-11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 22 except (jt=lb) 12=121. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 2,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Shadow_Wood Truss T15A Truss Type PIGGYBACK BASE Qty 3 Ply 1 4 Shadow Wood Job Reference (optional) I38023004 8.220 s Nov 16 2018 MiTek Industries, Inc. Fri Aug 2 10:25:34 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jAXtJ2ozokt8tlXqi1fHBQyGc1j-?9h98F1J8WXlUm1svMw94WLAwLw3hVGMJeQ8tryrw_F Scale = 1:102.1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 26 25 24 23 22 21 20 19 18 17 16 15 3x6 5x8 5x8 5x12 3x12 4x6 3x4 3x6 3x8 MT18HS 5x12 6x10 3x8 3x6 3x6 3x8 3x6 3x6 3x6 3x6 4x8 10x10 3x8 MT18HS 3x8 MT18HS 5-5-0 5-5-0 5-6-12 0-1-12 9-5-0 3-10-4 14-11-8 5-6-8 18-0-9 3-1-1 27-7-0 9-6-7 34-2-0 6-7-0 43-8-14 9-6-14 49-11-5 6-2-7 56-4-0 6-4-11 -0-11-0 0-11-0 5-5-0 5-5-0 9-5-0 4-0-0 14-11-8 5-6-8 22-6-4 7-6-12 27-7-0 5-0-12 34-2-0 6-7-0 39-2-15 5-0-15 48-0-0 8-9-0 56-4-0 8-4-0 57-3-0 0-11-0 0-3-144-8-411-0-012-0-00-11-01-0-012-0-03.50 12 6.00 12 Plate Offsets (X,Y)-- [8:0-5-0,0-2-0], [9:0-8-8,0-1-12], [15:0-5-0,0-2-4], [15:0-2-7,0-1-4], [26:0-6-8,0-3-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-AS 0.80 0.98 0.78 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.30 -0.91 0.17 (loc) 17-19 17-19 15 l/defl >999 >664 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 255 lb FT = 20% GRIP 169/123 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 3-25: 2x4 SPF-S Stud, 23-25: 2x4 SPF 2100F 1.8E WEBS 2x3 SPF No.2 *Except* 7-20,8-20,9-20,9-19,10-19: 2x4 SPF No.2, 13-15: 2x6 SPF No.2 4-24: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals, and 2-0-0 oc purlins (3-4-13 max.): 8-9. BOT CHORD Rigid ceiling directly applied. WEBS 1 Row at midpt 4-26, 7-20, 9-20, 10-19, 6-24 REACTIONS.(lb/size)2=69/0-3-8, 25=2478/0-3-8, 15=2065/0-3-8 Max Horz 2=-141(LC 7) Max Uplift 2=-63(LC 4), 25=-131(LC 6), 15=-125(LC 7) Max Grav 2=109(LC 10), 25=2478(LC 1), 15=2065(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-95/776, 3-4=-47/759, 4-6=-1803/315, 6-7=-2991/484, 7-8=-2422/470, 8-9=-2104/446, 9-10=-2439/472, 10-12=-3101/489, 12-13=-3266/424, 13-15=-1983/329 BOT CHORD 2-26=-698/174, 25-26=-2445/312, 3-26=-327/115, 22-24=-232/2694, 20-22=-129/2405, 19-20=-23/2115, 17-19=-135/2450, 16-17=-278/2895, 15-16=-111/628 WEBS 24-26=-121/1802, 4-26=-2854/346, 6-22=-251/174, 7-22=-38/464, 7-20=-651/217, 8-20=-97/722, 9-19=-101/771, 10-19=-705/227, 10-17=-40/518, 12-17=-373/188, 13-16=-134/2210, 6-24=-1426/166, 4-24=-1/636 NOTES-(10-11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2 except (jt=lb) 25=131, 15=125. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 2,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Shadow_Wood Truss T16 Truss Type PIGGYBACK BASE Qty 2 Ply 1 4 Shadow Wood Job Reference (optional) I38023005 8.220 s Nov 16 2018 MiTek Industries, Inc. Fri Aug 2 10:25:35 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jAXtJ2ozokt8tlXqi1fHBQyGc1j-TLFXLa2xvpfc5wc2T3ROdktMtlHoQxSWYI9iQHyrw_E Scale = 1:82.2 1 2 3 4 5 6 7 8 9 10 19 18 17 16 15 14 13 12 11 3x4 5x8 5x6 5x8 3x12 3x8 3x6 3x6 3x8 3x6 3x6 3x6 3x6 4x8 4x6 10x10 3x8 8-7-9 8-7-9 18-2-0 9-6-7 24-9-0 6-7-0 34-3-14 9-6-14 40-6-5 6-2-7 46-11-0 6-4-11 5-6-8 5-6-8 13-1-4 7-6-12 18-2-0 5-0-12 24-9-0 6-7-0 29-9-15 5-0-15 38-7-0 8-9-0 46-11-0 8-4-0 47-10-0 0-11-0 4-0-145-8-412-0-00-11-012-0-03.50 12 6.00 12 Plate Offsets (X,Y)-- [4:0-3-8,0-2-4], [5:0-5-8,0-2-4], [11:0-2-7,0-1-4], [11:0-5-0,0-2-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-AS 0.72 0.95 0.85 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.28 -0.82 0.18 (loc) 13-15 13-15 11 l/defl >999 >681 n/a L/d 240 180 n/a PLATES MT20 Weight: 224 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 3-16,4-16,5-16,5-15,6-15: 2x4 SPF No.2, 1-19,2-19: 2x4 SPF-S Stud 9-11: 2x6 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals, and 2-0-0 oc purlins (3-9-4 max.): 4-5. BOT CHORD Rigid ceiling directly applied. WEBS 1 Row at midpt 3-18, 3-16, 5-16, 6-15 2 Rows at 1/3 pts 2-19 REACTIONS.(lb/size)19=1861/0-3-8, 11=1931/0-3-8 Max Horz 19=-169(LC 4) Max Uplift 19=-66(LC 6), 11=-120(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2169/370, 3-4=-2060/420, 4-5=-1779/401, 5-6=-2157/433, 6-8=-2833/452, 8-9=-3024/390, 9-11=-1851/311 BOT CHORD 18-19=-92/1671, 16-18=-61/1914, 15-16=0/1864, 13-15=-101/2203, 12-13=-247/2668, 11-12=-108/607 WEBS 2-18=0/412, 3-16=-341/169, 4-16=-75/560, 5-16=-339/65, 5-15=-102/776, 6-15=-711/229, 6-13=-43/530, 8-13=-386/191, 2-19=-2310/284, 9-12=-107/2014 NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 19 except (jt=lb) 11=120. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 2,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Shadow_Wood Truss T16A Truss Type PIGGYBACK BASE Qty 1 Ply 1 4 Shadow Wood Job Reference (optional) I38023006 8.220 s Nov 16 2018 MiTek Industries, Inc. Fri Aug 2 10:25:36 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jAXtJ2ozokt8tlXqi1fHBQyGc1j-xXovYw3Zf7nTj4BF1nyd9xQXb8d09NzfmyvFyjyrw_D Scale = 1:83.1 1 2 3 4 5 6 7 8 9 10 11 20 19 18 17 16 15 14 13 12 3x12 5x6 5x8 3x12 3x8 3x6 3x6 3x6 3x8 3x6 3x6 3x6 3x6 3x4 4x6 10x10 3x8 4x8 8-7-4 8-7-4 18-2-0 9-6-13 24-9-0 6-7-0 34-3-14 9-6-14 40-6-5 6-2-7 46-11-0 6-4-12 4-5-5 4-5-5 13-1-1 8-7-12 18-2-0 5-0-15 24-9-0 6-7-0 29-9-15 5-0-15 38-5-13 8-7-14 46-11-0 8-5-3 47-10-0 0-11-0 2-11-012-0-00-11-012-0-06.00 12 Plate Offsets (X,Y)-- [5:0-3-8,0-2-4], [6:0-5-8,0-2-4], [12:0-2-7,0-1-4], [12:0-5-0,0-2-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-AS 0.72 0.95 0.90 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.28 -0.82 0.17 (loc) 14-16 14-16 12 l/defl >999 >683 n/a L/d 240 180 n/a PLATES MT20 Weight: 221 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 4-17,5-17,6-17,6-16,7-16: 2x4 SPF No.2, 1-20: 2x4 SPF-S Stud 10-12: 2x6 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals, and 2-0-0 oc purlins (3-9-1 max.): 5-6. BOT CHORD Rigid ceiling directly applied. WEBS 1 Row at midpt 4-19, 4-17, 6-17, 7-16, 2-20 REACTIONS.(lb/size)20=1861/0-3-8, 12=1931/0-3-8 Max Horz 20=-179(LC 4) Max Uplift 20=-65(LC 6), 12=-121(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-2180/364, 4-5=-2065/425, 5-6=-1778/403, 6-7=-2157/435, 7-9=-2833/453, 9-10=-3024/392, 10-12=-1851/311 BOT CHORD 19-20=-108/1532, 17-19=-67/1920, 16-17=0/1864, 14-16=-102/2203, 13-14=-248/2668, 12-13=-108/606 WEBS 2-19=0/491, 4-17=-355/179, 5-17=-82/573, 6-17=-340/65, 6-16=-102/776, 7-16=-711/228, 7-14=-42/530, 9-14=-386/191, 2-20=-2267/308, 10-13=-109/2015 NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 20 except (jt=lb) 12=121. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 2,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Shadow_Wood Truss T17 Truss Type HIP Qty 1 Ply 1 4 Shadow Wood Job Reference (optional) I38023007 8.220 s Nov 16 2018 MiTek Industries, Inc. Fri Aug 2 10:25:37 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jAXtJ2ozokt8tlXqi1fHBQyGc1j-PkMHmG4BQRwKLDmRaUTsi9ziQY1XusIp?cepUAyrw_C Scale = 1:84.2 1 2 3 4 5 6 7 8 9 10 11 20 19 18 17 16 15 14 13 12 3x12 5x12 5x6 3x8 3x8 3x6 3x8 3x6 3x6 3x8 3x6 3x6 3x6 4x8 3x4 4x6 10x10 3x8 8-3-14 8-3-14 19-4-13 11-1-0 23-0-3 3-7-5 34-0-13 11-0-11 40-3-5 6-2-7 46-8-0 6-4-11 4-0-8 4-0-8 12-9-14 8-9-6 19-4-13 6-6-15 23-0-3 3-7-5 29-6-15 6-6-12 38-4-0 8-9-0 46-8-0 8-4-0 47-7-0 0-11-0 3-0-812-7-012-8-150-11-012-7-06.00 12 Plate Offsets (X,Y)-- [5:0-6-0,0-0-15], [10:0-5-0,0-2-4], [12:0-2-7,0-1-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-AS 0.72 0.61 0.83 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.31 -0.89 0.13 (loc) 14-16 14-16 12 l/defl >999 >623 n/a L/d 240 180 n/a PLATES MT20 Weight: 224 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF 2100F 1.8E WEBS 2x3 SPF No.2 *Except* 4-17,5-17,5-16,6-16,7-16: 2x4 SPF No.2, 1-20: 2x4 SPF-S Stud 10-12: 2x6 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals, and 2-0-0 oc purlins (4-3-6 max.): 5-6. BOT CHORD Rigid ceiling directly applied. WEBS 1 Row at midpt 4-19, 4-17, 5-16, 7-16, 2-20 REACTIONS.(lb/size)20=1851/Mechanical, 12=1921/0-3-8 Max Horz 20=-188(LC 4) Max Uplift 20=-71(LC 6), 12=-126(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-2120/358, 4-5=-2004/423, 5-6=-1754/416, 6-7=-2062/429, 7-9=-2818/454, 9-10=-2999/396, 10-12=-1835/314 BOT CHORD 19-20=-105/1434, 17-19=-73/1888, 16-17=0/1702, 14-16=-110/2189, 13-14=-249/2647, 12-13=-113/649 WEBS 2-19=0/541, 4-17=-385/187, 5-17=-68/455, 5-16=-83/360, 6-16=-87/588, 7-16=-759/241, 7-14=-29/560, 9-14=-373/190, 2-20=-2221/299, 10-13=-106/1948 NOTES-(10-11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 20 except (jt=lb) 12=126. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 2,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Shadow_Wood Truss T18 Truss Type HIP Qty 1 Ply 1 4 Shadow Wood Job Reference (optional) I38023008 8.220 s Nov 16 2018 MiTek Industries, Inc. Fri Aug 2 10:25:38 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jAXtJ2ozokt8tlXqi1fHBQyGc1j-twwfzc4pBk2ByNLd8B_5EMVqlyJldKSyEGOM0cyrw_B Scale = 1:76.5 1 2 3 4 5 6 7 8 9 10 18 17 16 15 14 13 12 11 3x8 5x6 5x6 3x6 3x6 3x6 3x6 3x8 3x8 3x4 3x8 3x6 3x8 6x8 3x4 5x6 3x6 0-1-158-10-9 8-10-9 16-0-13 7-2-4 26-4-3 10-3-5 33-6-6 7-2-4 40-8-0 7-1-10 8-10-9 8-10-9 16-0-13 7-2-4 21-2-8 5-1-11 26-4-3 5-1-11 33-6-6 7-2-4 40-8-0 7-1-10 41-7-0 0-11-0 3-0-810-11-011-0-153-11-010-11-06.00 12 Plate Offsets (X,Y)-- [1:Edge,0-1-12], [9:0-2-12,0-2-0], [12:0-2-8,0-1-8], [17:0-2-8,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-AS 0.93 0.87 0.71 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.30 -0.81 0.08 (loc) 14-15 14-15 11 l/defl >999 >597 n/a L/d 240 180 n/a PLATES MT20 Weight: 195 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 4-15,5-15,5-14,6-14,1-18: 2x4 SPF No.2, 9-11: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals, and 2-0-0 oc purlins (4-8-1 max.): 4-6. BOT CHORD Rigid ceiling directly applied. WEBS 1 Row at midpt 2-15, 5-15, 5-14 REACTIONS.(lb/size)18=1614/Mechanical, 11=1680/0-3-8 Max Horz 18=165(LC 5) Max Uplift 18=-57(LC 6), 11=-79(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-1903/289, 2-4=-1764/343, 4-5=-1481/342, 5-6=-1413/335, 6-8=-1681/332, 8-9=-1588/270, 1-18=-1523/242, 9-11=-1609/274 BOT CHORD 15-17=-79/1604, 14-15=-7/1530, 12-14=-51/1345 WEBS 2-17=-330/130, 4-15=-29/449, 5-15=-264/116, 5-14=-391/107, 6-14=-16/418, 8-12=-558/127, 1-17=-116/1554, 9-12=-101/1466 NOTES-(10-11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 18, 11. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 2,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Shadow_Wood Truss T19 Truss Type HIP Qty 1 Ply 1 4 Shadow Wood Job Reference (optional) I38023009 8.220 s Nov 16 2018 MiTek Industries, Inc. Fri Aug 2 10:25:39 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jAXtJ2ozokt8tlXqi1fHBQyGc1j-M6U2By5Ry2A2aXwqivWKna21TMjIMlQ5Sw7vZ2yrw_A Scale = 1:73.3 1 2 3 4 5 6 7 8 9 17 16 15 14 13 12 11 10 5x6 5x12 3x8 3x4 3x6 3x6 3x8 3x4 2x4 3x8 5x12 3x4 3x6 4x8 3x4 3x6 0-1-156-10-9 6-10-9 12-8-13 5-10-4 21-2-8 8-5-11 29-8-3 8-5-11 40-8-0 10-11-13 6-10-9 6-10-9 12-8-13 5-10-4 21-2-8 8-5-11 29-8-3 8-5-11 35-1-10 5-5-7 40-8-0 5-6-6 41-7-0 0-11-0 3-0-89-3-09-4-153-11-09-3-06.00 12 Plate Offsets (X,Y)-- [1:Edge,0-1-12], [3:0-6-0,0-0-15], [6:0-6-0,0-0-15], [16:0-2-8,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-AS 0.81 0.59 0.85 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.26 -0.67 0.08 (loc) 10-11 10-11 10 l/defl >999 >725 n/a L/d 240 180 n/a PLATES MT20 Weight: 184 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF 2100F 1.8E *Except* 12-14: 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 3-13,6-13,8-10: 2x4 SPF No.2, 1-17,7-10: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals, and 2-0-0 oc purlins (3-0-3 max.): 3-6. BOT CHORD Rigid ceiling directly applied. WEBS 1 Row at midpt 3-15, 4-13, 6-11, 7-10 REACTIONS.(lb/size)17=1614/Mechanical, 10=1680/0-3-8 Max Horz 17=149(LC 5) Max Uplift 17=-41(LC 6), 10=-62(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-1771/258, 2-3=-1838/321, 3-4=-1879/352, 4-6=-1877/352, 6-7=-1686/299, 1-17=-1542/221, 8-10=-254/152 BOT CHORD 15-16=-80/1508, 13-15=-69/1582, 11-13=-13/1459, 10-11=-55/1166 WEBS 2-16=-489/122, 2-15=-63/252, 3-13=-98/542, 4-13=-598/188, 6-13=-99/692, 7-11=-13/522, 1-16=-122/1556, 7-10=-1725/175 NOTES-(10-11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 17, 10. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 2,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Shadow_Wood Truss T20 Truss Type HIP Qty 1 Ply 1 4 Shadow Wood Job Reference (optional) I38023010 8.220 s Nov 16 2018 MiTek Industries, Inc. Fri Aug 2 10:25:40 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jAXtJ2ozokt8tlXqi1fHBQyGc1j-qJ2QOI63jMIvChU0Gc1ZKnbCgm_c5E6FhatT5Uyrw_9 Scale = 1:73.6 1 2 3 4 5 6 7 8 9 16 15 14 13 12 11 10 3x4 5x6 3x6 3x8 MT18HS3x8 3x6 3x4 3x4 3x4 4x6 3x4 5x6 4x10 5x8 3x8 MT18HS0-1-159-4-13 9-4-13 21-2-8 11-9-11 33-0-3 11-9-11 40-8-0 7-7-13 4-2-14 4-2-14 9-4-13 5-1-15 17-6-1 8-1-4 24-10-15 7-4-13 33-0-3 8-1-4 40-8-0 7-7-13 41-7-0 0-11-0 3-0-87-7-07-8-153-11-07-7-06.00 12 Plate Offsets (X,Y)-- [7:0-4-2,Edge], [8:0-3-0,0-1-12] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-AS 0.78 0.91 0.69 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.33 -0.91 0.12 (loc) 11-13 11-13 10 l/defl >999 >530 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 168 lb FT = 20% GRIP 169/123 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 12-14: 2x4 SPF 2100F 1.8E WEBS 2x3 SPF No.2 *Except* 4-15,6-11: 2x4 SPF No.2, 1-16,8-10: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals, and 2-0-0 oc purlins (3-4-5 max.): 3-7. BOT CHORD Rigid ceiling directly applied. WEBS 1 Row at midpt 4-15, 6-11, 2-16, 8-10 REACTIONS.(lb/size)16=1614/Mechanical, 10=1680/0-3-8 Max Horz 16=133(LC 5) Max Uplift 16=-21(LC 6), 10=-41(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1854/272, 3-4=-1612/277, 4-6=-2252/320, 6-7=-1387/261, 7-8=-1639/241, 8-10=-1621/248 BOT CHORD 15-16=-128/1207, 13-15=-179/2225, 11-13=-162/2150 WEBS 2-15=-28/615, 3-15=0/468, 4-15=-891/145, 6-13=0/343, 6-11=-1081/145, 7-11=0/372, 2-16=-1815/208, 8-11=-50/1491 NOTES-(11-12) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 16, 10. 8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 2,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Shadow_Wood Truss T21 Truss Type HIP Qty 1 Ply 1 4 Shadow Wood Job Reference (optional) I38023011 8.220 s Nov 16 2018 MiTek Industries, Inc. Fri Aug 2 10:25:40 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jAXtJ2ozokt8tlXqi1fHBQyGc1j-qJ2QOI63jMIvChU0Gc1ZKnbFtm_25DgFhatT5Uyrw_9 Scale = 1:73.3 1 2 3 4 5 6 7 8 9 10 18 17 16 15 14 13 12 11 4x6 5x6 3x6 3x4 3x6 4x10 3x6 3x4 3x4 3x4 3x6 3x4 6x6 5x8 3x6 5x6 3x6 0-1-156-0-13 6-0-13 16-1-15 10-1-2 26-3-1 10-1-2 36-4-3 10-1-2 40-8-0 4-3-13 6-0-13 6-0-13 13-7-3 7-6-6 21-2-8 7-7-5 28-9-13 7-7-5 36-4-3 7-6-6 40-8-0 4-3-13 41-7-0 0-11-0 3-0-85-11-06-0-153-11-05-11-06.00 12 Plate Offsets (X,Y)-- [1:0-3-0,0-1-8], [9:0-2-7,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-AS 0.64 0.94 0.72 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.25 -0.74 0.17 (loc) 15-17 15-17 11 l/defl >999 >653 n/a L/d 240 180 n/a PLATES MT20 Weight: 162 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 3-17,6-12: 2x4 SPF No.2, 1-18,9-11: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals, and 2-0-0 oc purlins (2-11-10 max.): 2-8. BOT CHORD Rigid ceiling directly applied. WEBS 1 Row at midpt 3-17, 6-12 REACTIONS.(lb/size)18=1614/Mechanical, 11=1680/0-3-8 Max Horz 18=117(LC 5) Max Uplift 18=-62(LC 5), 11=-78(LC 4) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-1714/216, 2-3=-1474/232, 3-5=-2786/338, 5-6=-2660/328, 6-8=-1088/196, 8-9=-1253/191, 1-18=-1572/190, 9-11=-1669/215 BOT CHORD 15-17=-259/2622, 14-15=-281/2922, 12-14=-228/2432 WEBS 2-17=0/424, 3-17=-1468/181, 3-15=0/478, 5-14=-403/109, 6-14=0/594, 6-12=-1687/191, 8-12=0/291, 1-17=-91/1593, 9-12=-74/1464 NOTES-(10-11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 18, 11. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 2,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Shadow_Wood Truss TG01 Truss Type COMMON GIRDER Qty 1 Ply 2 4 Shadow Wood Job Reference (optional) I38023012 8.220 s Nov 16 2018 MiTek Industries, Inc. Fri Aug 2 10:25:42 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jAXtJ2ozokt8tlXqi1fHBQyGc1j-mhAAp_7KFzYcR?ePN131PCgVlZocZ3PY9uMZ9Nyrw_7 Scale: 3/16"=1' 1 2 3 4 5 6 7 12 11 10 9 813141516 4x6 3x6 3x6 10x10 5x8 8x10 12x12 4x10 3x6 10x10 1-9-8 1-9-8 2-3-0 0-5-8 6-10-14 4-7-14 11-4-2 4-5-4 11-8-0 0-3-14 15-9-8 4-1-8 4-7-1 4-7-1 6-10-14 2-3-13 11-4-2 4-5-4 11-8-0 0-3-14 15-9-8 4-1-8 16-8-8 0-11-0 6-9-210-7-11-3-010.00 12 Plate Offsets (X,Y)-- [8:0-1-12,0-0-0], [8:Edge,0-8-6], [9:0-3-8,0-5-0], [10:0-2-8,0-6-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-MSH 1.00 0.43 0.96 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.07 -0.17 0.01 (loc) 9-10 9-10 8 l/defl >999 >929 n/a L/d 240 180 n/a PLATES MT20 Weight: 243 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x8 SP 2400F 2.0E WEBS 2x3 SPF No.2 *Except* 3-11: 2x4 SPF No.2, 1-12,6-8,5-9: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-0-7 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-11 REACTIONS.(lb/size)8=4791/0-3-8, 11=7478/0-5-8 Max Horz 11=-325(LC 11) Max Uplift 8=-679(LC 6), 11=-532(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-311/133, 2-3=-258/138, 3-5=-3242/344, 5-6=-5698/782, 1-12=-817/72, 6-8=-4659/652 BOT CHORD 10-11=-236/2441, 9-10=-538/4303, 8-9=-61/425 WEBS 3-11=-4567/513, 3-10=-500/5609, 5-10=-2481/619, 1-11=-79/639, 6-9=-511/3972, 5-9=-639/3019 NOTES-(9-10) 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc. Bottom chords connected as follows: 2x8 - 2 rows staggered at 0-6-0 oc. Webs connected as follows: 2x3 - 1 row at 0-9-0 oc, 2x4 - 1 row at 0-9-0 oc, Except member 5-9 2x4 - 1 row at 0-5-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 8=679, 11=532. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 1831 lb down and 83 lb up at 1-11-4, 1594 lb down and 69 lb up at 3-11-4, 1594 lb down and 53 lb up at 5-11-4, 1594 lb down and 33 lb up at 7-11-4, and 1594 lb down and 74 lb up at 9-11-4, and 2757 lb down and 802 lb up at 11-8-0 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard Continued on page 2 August 2,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Shadow_Wood Truss TG01 Truss Type COMMON GIRDER Qty 1 Ply 2 4 Shadow Wood Job Reference (optional) I38023012 8.220 s Nov 16 2018 MiTek Industries, Inc. Fri Aug 2 10:25:42 2019 Page 2 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jAXtJ2ozokt8tlXqi1fHBQyGc1j-mhAAp_7KFzYcR?ePN131PCgVlZocZ3PY9uMZ9Nyrw_7 LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 2-6=-60, 6-7=-60, 8-12=-20 Concentrated Loads (lb) Vert: 11=-1831(B) 9=-2757(B) 13=-1594(B) 14=-1594(B) 15=-1594(B) 16=-1594(B) 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Shadow_Wood Truss TG02 Truss Type HALF HIP GIRDER Qty 1 Ply 2 4 Shadow Wood Job Reference (optional) I38023013 8.220 s Nov 16 2018 MiTek Industries, Inc. Fri Aug 2 10:25:43 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jAXtJ2ozokt8tlXqi1fHBQyGc1j-EujY1K8y0HgT38DbxlaGxQCknz_rIYqhNY57ipyrw_6 Scale = 1:79.8 1 2 3 4 5 6 7 8 9 10 11 18 17 16 15 14 13 12232425262728293031323334353637383940414243 5x6 3x6 3x4 5x6 8x10 3x6 5x6 4x6 3x6 4x6 3x6 4x6 3x6 5x6 5x6 3x6 5x8 0-1-27-4-0 7-4-0 16-10-0 9-6-0 26-4-0 9-6-0 35-11-7 9-7-7 45-7-8 9-8-1 -0-11-0 0-11-0 7-4-0 7-4-0 14-3-11 6-11-11 22-6-6 8-2-11 30-1-10 7-7-3 38-5-4 8-3-10 45-7-8 7-2-4 0-11-04-5-144-7-04-5-146.00 12 Plate Offsets (X,Y)-- [4:0-3-0,0-2-7], [11:Edge,0-2-8], [18:0-2-8,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-MSH 0.72 1.00 0.89 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.39 -0.82 0.16 (loc) 15-16 15-16 12 l/defl >999 >667 n/a L/d 240 180 n/a PLATES MT20 Weight: 411 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF 2100F 1.8E *Except* 9-11: 2x4 SPF No.2 BOT CHORD 2x6 SP 2400F 2.0E *Except* 12-14: 2x6 SPF No.2 WEBS 2x3 SPF No.2 *Except* 5-18,10-12: 2x4 SPF No.2 SLIDER Left 2x4 SPF-S Stud 2-0-0 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (4-6-6 max.): 4-11. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 10-12 REACTIONS.(lb/size)12=3198/0-3-8, 2=3131/0-3-8 Max Horz 2=126(LC 12) Max Uplift 12=-963(LC 4), 2=-791(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-5357/1507, 4-5=-4659/1345, 5-7=-8298/2474, 7-8=-8633/2595, 8-10=-5968/1813 BOT CHORD 2-18=-1382/4710, 16-18=-2270/7577, 15-16=-2640/8757, 13-15=-2375/7846, 12-13=-1424/4652 WEBS 4-18=-601/2073, 5-18=-3444/1078, 5-16=-439/1409, 7-16=-602/204, 8-15=-337/1159, 8-13=-2300/688, 10-13=-755/2545, 10-12=-5336/1602 NOTES-(11-12) 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc, 2x3 - 1 row at 0-9-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc. Webs connected as follows: 2x3 - 1 row at 0-9-0 oc, 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 5) Provide adequate drainage to prevent water ponding. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 12=963, 2=791. 8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. Continued on page 2 August 2,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Shadow_Wood Truss TG02 Truss Type HALF HIP GIRDER Qty 1 Ply 2 4 Shadow Wood Job Reference (optional) I38023013 8.220 s Nov 16 2018 MiTek Industries, Inc. Fri Aug 2 10:25:43 2019 Page 2 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jAXtJ2ozokt8tlXqi1fHBQyGc1j-EujY1K8y0HgT38DbxlaGxQCknz_rIYqhNY57ipyrw_6 NOTES-(11-12) 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 126 lb down and 47 lb up at 2-10-4, 119 lb down and 50 lb up at 4-10-4, 119 lb down and 65 lb up at 6-10-4, 119 lb down and 71 lb up at 8-10-4, 119 lb down and 71 lb up at 10-10-4, 119 lb down and 71 lb up at 12-10-4, 119 lb down and 71 lb up at 14-10-4, 119 lb down and 71 lb up at 16-10-4, 119 lb down and 71 lb up at 18-10-4, 119 lb down and 71 lb up at 20-10-4, 119 lb down and 71 lb up at 22-10-4, 119 lb down and 71 lb up at 24-10-4, 119 lb down and 71 lb up at 26-10-4, 119 lb down and 71 lb up at 28-10-4, 119 lb down and 71 lb up at 30-10-4, 119 lb down and 71 lb up at 32-10-4, 119 lb down and 71 lb up at 34-10-4, 119 lb down and 71 lb up at 36-10-4, 119 lb down and 71 lb up at 38-10-4, 119 lb down and 71 lb up at 40-10-4, and 119 lb down and 71 lb up at 42-10-4, and 123 lb down and 69 lb up at 44-10-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-4=-60, 4-11=-60, 12-19=-20 Concentrated Loads (lb) Vert: 16=-119 23=-126 24=-119 25=-119 26=-119 27=-119 28=-119 29=-119 30=-119 31=-119 32=-119 33=-119 34=-119 35=-119 36=-119 37=-119 38=-119 39=-119 40=-119 41=-119 42=-119 43=-123 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Shadow_Wood Truss TG03 Truss Type HIP GIRDER Qty 1 Ply 2 4 Shadow Wood Job Reference (optional) I38023014 8.220 s Nov 16 2018 MiTek Industries, Inc. Fri Aug 2 10:25:44 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jAXtJ2ozokt8tlXqi1fHBQyGc1j-i4HxEf9anaoKgIonVS5VUdlxzNNq13urcCrgEGyrw_5 Scale = 1:73.5 1 2 3 4 5 6 7 8 9 10 11 20 19 18 17 16 15 14 13 12212223242526272829303132333435363738 39 5x6 5x6 3x6 2x4 4x8 6x8 4x6 4x6 3x4 4x6 3x4 4x6 4x6 2x4 6x8 8x8 3x6 5x6 4x8 0-1-23-1-0 3-1-0 12-1-12 9-0-12 21-2-8 9-0-12 30-3-4 9-0-12 39-4-0 9-0-12 40-8-0 1-4-0 3-1-0 3-1-0 10-4-0 7-3-0 17-7-0 7-3-0 24-10-0 7-3-0 32-1-0 7-3-0 39-4-0 7-3-0 40-8-0 1-4-0 41-7-0 0-11-0 3-0-84-5-144-7-03-11-04-5-146.00 12 Plate Offsets (X,Y)-- [2:0-3-0,0-2-7], [9:0-3-0,0-2-7], [10:0-2-11,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-MSH 0.63 0.83 0.58 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.30 -0.64 0.14 (loc) 16-18 16-18 12 l/defl >999 >760 n/a L/d 240 180 n/a PLATES MT20 Weight: 367 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SPF No.2 WEBS 2x3 SPF No.2 *Except* 3-19,8-13: 2x4 SPF No.2, 1-20,10-12: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (4-3-9 max.): 2-9. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-19, 8-13 REACTIONS.(lb/size)20=2777/Mechanical, 12=2903/0-3-8 Max Horz 20=100(LC 4) Max Uplift 20=-790(LC 4), 12=-843(LC 4) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-2175/663, 2-3=-1922/601, 3-5=-5887/1792, 5-6=-6966/2115, 6-8=-5354/1642, 8-9=-830/289, 9-10=-909/312, 1-20=-2840/822, 10-12=-3106/908 BOT CHORD 18-19=-1639/5270, 16-18=-2085/6761, 14-16=-2015/6548, 13-14=-1426/4624 WEBS 2-19=-209/668, 3-19=-3847/1176, 3-18=-465/1536, 5-18=-1103/346, 5-16=-113/330, 6-16=-192/633, 6-14=-1498/462, 8-14=-546/1811, 8-13=-4349/1323, 1-19=-787/2668, 10-13=-835/2787 NOTES-(12-13) 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc. Webs connected as follows: 2x3 - 1 row at 0-9-0 oc, 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 5) Provide adequate drainage to prevent water ponding. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) Refer to girder(s) for truss to truss connections. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 20=790, 12=843. 9) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. Continued on page 2 August 2,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Shadow_Wood Truss TG03 Truss Type HIP GIRDER Qty 1 Ply 2 4 Shadow Wood Job Reference (optional) I38023014 8.220 s Nov 16 2018 MiTek Industries, Inc. Fri Aug 2 10:25:45 2019 Page 2 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jAXtJ2ozokt8tlXqi1fHBQyGc1j-AGrJR?ACYuwBISNz29dk1rI6jnj3mW8_rsaEmiyrw_4 NOTES-(12-13) 11) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 119 lb down and 71 lb up at 1-9-12, 119 lb down and 71 lb up at 3-9-12, 119 lb down and 71 lb up at 5-9-12, 119 lb down and 71 lb up at 7-9-12, 119 lb down and 71 lb up at 9-9-12, 119 lb down and 71 lb up at 11-9-12, 119 lb down and 71 lb up at 13-9-12, 119 lb down and 71 lb up at 15-9-12, 119 lb down and 71 lb up at 17-9-12, 119 lb down and 71 lb up at 19-9-12, 119 lb down and 71 lb up at 21-9-12, 119 lb down and 71 lb up at 23-9-12, 119 lb down and 71 lb up at 25-9-12, 119 lb down and 71 lb up at 27-9-12, 119 lb down and 71 lb up at 29-9-12, 119 lb down and 71 lb up at 31-9-12, 119 lb down and 71 lb up at 33-9-12, 119 lb down and 71 lb up at 35-9-12, and 119 lb down and 71 lb up at 37-9-12, and 122 lb down and 63 lb up at 39-9-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 12) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 13) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 2-9=-60, 9-10=-60, 10-11=-60, 12-20=-20 Concentrated Loads (lb) Vert: 17=-119 21=-119 22=-119 23=-119 24=-119 25=-119 26=-119 27=-119 28=-119 29=-119 30=-119 31=-119 32=-119 33=-119 34=-119 35=-119 36=-119 37=-119 38=-119 39=-122 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Shadow_Wood Truss V01 Truss Type VALLEY Qty 1 Ply 1 4 Shadow Wood Job Reference (optional) I38023015 8.220 s Nov 16 2018 MiTek Industries, Inc. Fri Aug 2 10:25:45 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jAXtJ2ozokt8tlXqi1fHBQyGc1j-AGrJR?ACYuwBISNz29dk1rI9WntXmc9_rsaEmiyrw_4 Scale = 1:41.5 1 2 3 4 5 10 9 8 7 61112 2x4 2x4 5x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 13-6-8 13-6-8 6-7-1 6-7-1 13-6-8 6-11-7 1-0-156-6-130-9-410.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-R 0.39 0.16 0.20 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 6 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 41 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 13-6-8. (lb) - Max Horz 10=-156(LC 4) Max Uplift All uplift 100 lb or less at joint(s) 10, 6 except 9=-131(LC 6), 7=-135(LC 7) Max Grav All reactions 250 lb or less at joint(s) 10, 6 except 8=455(LC 1), 9=355(LC 10), 7=366(LC 11) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 10, 6 except (jt=lb) 9=131, 7=135. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 2,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Shadow_Wood Truss V02 Truss Type Valley Qty 1 Ply 1 4 Shadow Wood Job Reference (optional) I38023016 8.220 s Nov 16 2018 MiTek Industries, Inc. Fri Aug 2 10:25:46 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jAXtJ2ozokt8tlXqi1fHBQyGc1j-eTPhfLBqJC22wcyAct8zZ2qLmAEjV5k73VKnJ8yrw_3 Scale = 1:35.5 1 2 3 4 5 8 7 63x4 5x6 3x4 2x4 2x4 2x4 2x4 2x4 -0-0-13 0-0-13 13-3-3 13-3-3 6-7-1 6-7-1 13-3-3 6-8-2 0-0-155-6-130-0-410.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-SH 0.36 0.09 0.11 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 35 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 13-3-11. (lb) - Max Horz 1=123(LC 5) Max Uplift All uplift 100 lb or less at joint(s) 1, 5 except 8=-116(LC 6), 6=-116(LC 7) Max Grav All reactions 250 lb or less at joint(s) 1, 5, 7 except 8=306(LC 10), 6=306(LC 11) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5 except (jt=lb) 8=116, 6=116. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 2,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Shadow_Wood Truss V03 Truss Type VALLEY Qty 1 Ply 1 4 Shadow Wood Job Reference (optional) I38023017 8.220 s Nov 16 2018 MiTek Industries, Inc. Fri Aug 2 10:25:47 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jAXtJ2ozokt8tlXqi1fHBQyGc1j-7fz3shBT4VAvXmXMAafC6GNWIaXrEYBHI93Krayrw_2 Scale = 1:29.2 1 2 3 43x8 4x6 3x8 2x4 10-11-3 10-11-3 10-11-8 0-0-5 5-5-12 5-5-12 10-11-8 5-5-12 0-0-44-6-130-0-410.00 12 Plate Offsets (X,Y)-- [1:0-4-0,0-1-4], [3:0-4-0,0-1-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-SH 0.37 0.29 0.10 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 29 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=207/10-10-14, 3=207/10-10-14, 4=399/10-10-14 Max Horz 1=-98(LC 4) Max Uplift 1=-15(LC 6), 3=-21(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 2,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Shadow_Wood Truss V04 Truss Type Valley Qty 1 Ply 1 4 Shadow Wood Job Reference (optional) I38023018 8.220 s Nov 16 2018 MiTek Industries, Inc. Fri Aug 2 10:25:47 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jAXtJ2ozokt8tlXqi1fHBQyGc1j-7fz3shBT4VAvXmXMAafC6GNTnaW4EZrHI93Krayrw_2 Scale: 1/2"=1' 1 2 3 42x4 3x4 2x4 2x4 0-0-5 0-0-5 8-6-11 8-6-6 4-3-6 4-3-6 8-6-11 4-3-6 0-0-43-6-130-0-410.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.53 0.34 0.05 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 18 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=181/8-6-2, 3=181/8-6-2, 4=276/8-6-2 Max Horz 1=-77(LC 4) Max Uplift 1=-26(LC 7), 3=-32(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 2,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Shadow_Wood Truss V05 Truss Type Valley Qty 1 Ply 1 4 Shadow Wood Job Reference (optional) I38023019 8.220 s Nov 16 2018 MiTek Industries, Inc. Fri Aug 2 10:25:48 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jAXtJ2ozokt8tlXqi1fHBQyGc1j-brXR41C5rpIm9w6YkIAReTwin_v1z0XQXppuN1yrw_1 Scale = 1:18.3 1 2 3 4 2x4 3x4 2x4 2x4 0-0-5 0-0-5 6-1-14 6-1-10 3-0-15 3-0-15 6-1-14 3-0-15 0-0-42-6-130-0-410.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.26 0.17 0.03 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 13 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=127/6-1-5, 3=127/6-1-5, 4=193/6-1-5 Max Horz 1=54(LC 5) Max Uplift 1=-18(LC 7), 3=-22(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 2,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Shadow_Wood Truss V06 Truss Type Valley Qty 1 Ply 1 4 Shadow Wood Job Reference (optional) I38023020 8.220 s Nov 16 2018 MiTek Industries, Inc. Fri Aug 2 10:25:49 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jAXtJ2ozokt8tlXqi1fHBQyGc1j-315qHNDjc7Qdn3hlH?hgBhSvFODRiTBamTYRvTyrw_0 Scale = 1:10.6 1 2 3 2x4 2x4 2x4 3-8-13 3-8-13 3-9-2 0-0-5 1-10-9 1-10-9 3-9-2 1-10-9 0-0-41-6-130-0-410.00 12 Plate Offsets (X,Y)-- [2:0-2-0,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.08 0.22 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 6 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-9-2 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=127/3-8-8, 3=127/3-8-8 Max Horz 1=-31(LC 4) Max Uplift 1=-5(LC 6), 3=-5(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 2,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Shadow_Wood Truss V09 Truss Type Valley Qty 1 Ply 1 4 Shadow Wood Job Reference (optional) I38023021 8.220 s Nov 16 2018 MiTek Industries, Inc. Fri Aug 2 10:25:49 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jAXtJ2ozokt8tlXqi1fHBQyGc1j-315qHNDjc7Qdn3hlH?hgBhSuiOD7iRKamTYRvTyrw_0 Scale = 1:55.3 1 2 3 4 5 6 12 11 10 9 8 7 3x8 4x6 2x4 2x4 2x4 5x6 2x4 2x4 2x4 2x4 2x4 17-9-0 17-9-0 9-8-8 9-8-8 17-9-0 8-0-8 0-9-48-10-62-1-1510.00 12 Plate Offsets (X,Y)-- [1:0-1-1,0-1-4], [10:0-3-0,0-3-0], [12:0-0-0,0-1-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-R 0.18 0.24 0.18 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 7 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 64 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 10-12: 2x4 SPF-S Stud WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 4-9 REACTIONS.All bearings 17-9-0. (lb) - Max Horz 12=221(LC 5) Max Uplift All uplift 100 lb or less at joint(s) 7, 9 except 12=-194(LC 4), 10=-123(LC 6), 11=-127(LC 6), 8=-138(LC 7) Max Grav All reactions 250 lb or less at joint(s) 12, 7, 11 except 9=445(LC 1), 10=424(LC 10), 8=442(LC 11) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-270/244, 3-4=-105/251 WEBS 3-10=-267/174, 5-8=-279/187 NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 7, 9 except (jt=lb) 12=194, 10=123, 11=127, 8=138. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 2,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Shadow_Wood Truss V10 Truss Type Valley Qty 1 Ply 1 4 Shadow Wood Job Reference (optional) I38023022 8.220 s Nov 16 2018 MiTek Industries, Inc. Fri Aug 2 10:25:50 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jAXtJ2ozokt8tlXqi1fHBQyGc1j-XEfCVjELMQYUODFxrjCvku?1NoWiRszj_7I?Svyrw_? Scale = 1:49.5 1 2 3 4 5 9 8 7 63x6 4x6 2x4 2x4 2x4 5x6 2x4 2x4 2x4 17-5-11 17-5-11 9-5-3 9-5-3 17-5-11 8-0-8 0-0-47-10-61-1-1510.00 12 Plate Offsets (X,Y)-- [9:0-3-0,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-SH 0.32 0.41 0.29 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 6 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 57 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 1-9: 2x4 SPF-S Stud WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 17-5-7. (lb) - Max Horz 1=186(LC 5) Max Uplift All uplift 100 lb or less at joint(s) 1, 6, 8 except 9=-158(LC 6), 7=-143(LC 7) Max Grav All reactions 250 lb or less at joint(s) 1, 6 except 8=382(LC 1), 9=512(LC 10), 7=443(LC 11) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-9=-317/201, 4-7=-279/189 NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 6, 8 except (jt=lb) 9=158, 7=143. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 2,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Shadow_Wood Truss V11 Truss Type Valley Qty 1 Ply 1 4 Shadow Wood Job Reference (optional) I38023023 8.220 s Nov 16 2018 MiTek Industries, Inc. Fri Aug 2 10:25:51 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jAXtJ2ozokt8tlXqi1fHBQyGc1j-?QCai3Ez7kgL0Nq7PQj8G6YEWBupALOtDn1Y_Myrw__ Scale = 1:44.7 1 2 3 4 5 9 8 7 610113x4 4x6 3x6 3x6 2x4 2x4 2x4 2x4 2x4 0-0-5 0-0-5 16-5-10 16-5-5 8-2-13 8-2-13 16-5-10 8-2-13 0-0-46-10-60-0-410.00 12 Plate Offsets (X,Y)-- [8:0-1-8,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-SH 0.16 0.29 0.15 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 51 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 1-8: 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 16-5-0. (lb) - Max Horz 1=-152(LC 4) Max Uplift All uplift 100 lb or less at joint(s) 1 except 9=-136(LC 6), 6=-136(LC 7) Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 7=392(LC 1), 9=425(LC 10), 6=427(LC 11) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-9=-273/176, 4-6=-270/175 NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1 except (jt=lb) 9=136, 6=136. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 2,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Shadow_Wood Truss V12 Truss Type Valley Qty 1 Ply 1 4 Shadow Wood Job Reference (optional) I38023024 8.220 s Nov 16 2018 MiTek Industries, Inc. Fri Aug 2 10:25:52 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jAXtJ2ozokt8tlXqi1fHBQyGc1j-TcmyvOFbu2oCeXPKz8FNpJ4MBbGVvp00SRn5Voyrvzz Scale = 1:37.3 1 2 3 4 5 8 7 69103x4 5x6 3x4 2x4 2x4 2x4 2x4 2x4 0-0-5 0-0-5 14-0-13 14-0-8 7-0-7 7-0-7 14-0-13 7-0-7 0-0-45-10-60-0-410.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-SH 0.36 0.13 0.12 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 38 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 14-0-4. (lb) - Max Horz 1=-130(LC 4) Max Uplift All uplift 100 lb or less at joint(s) 1, 5 except 8=-120(LC 6), 6=-119(LC 7) Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 7=387(LC 1), 8=339(LC 10), 6=339(LC 11) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5 except (jt=lb) 8=120, 6=119. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 2,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Shadow_Wood Truss V13 Truss Type Valley Qty 1 Ply 1 4 Shadow Wood Job Reference (optional) I38023025 8.220 s Nov 16 2018 MiTek Industries, Inc. Fri Aug 2 10:25:52 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jAXtJ2ozokt8tlXqi1fHBQyGc1j-TcmyvOFbu2oCeXPKz8FNpJ4LBbDLvp60SRn5Voyrvzz Scale = 1:30.9 1 2 3 44x8 4x6 4x8 2x4 0-0-5 0-0-5 11-8-0 11-7-12 5-10-0 5-10-0 11-8-0 5-10-0 0-0-44-10-60-0-410.00 12 Plate Offsets (X,Y)-- [1:0-7-1,Edge], [3:0-3-2,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-SH 0.42 0.34 0.12 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 31 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=221/11-7-7, 3=221/11-7-7, 4=427/11-7-7 Max Horz 1=105(LC 5) Max Uplift 1=-16(LC 6), 3=-22(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 2,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Shadow_Wood Truss V14 Truss Type VALLEY Qty 1 Ply 1 4 Shadow Wood Job Reference (optional) I38023026 8.220 s Nov 16 2018 MiTek Industries, Inc. Fri Aug 2 10:25:53 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jAXtJ2ozokt8tlXqi1fHBQyGc1j-xpKK7kGDfLx3Fh_WWrmcLXdY6?bOeHF9h5Wf1Eyrvzy Scale = 1:25.7 1 2 3 43x8 3x6 3x8 2x4 0-0-5 0-0-5 9-3-4 9-2-15 4-7-10 4-7-10 9-3-4 4-7-10 0-0-43-10-60-0-410.00 12 Plate Offsets (X,Y)-- [1:0-5-13,Edge], [2:0-3-12,0-1-8], [3:0-3-2,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-SH 0.29 0.22 0.06 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 22 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=170/9-2-10, 3=170/9-2-10, 4=341/9-2-10 Max Horz 1=-83(LC 4) Max Uplift 1=-11(LC 6), 3=-16(LC 7), 4=-2(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3, 4. 6) Non Standard bearing condition. Review required. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 2,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Shadow_Wood Truss V15 Truss Type Valley Qty 1 Ply 1 4 Shadow Wood Job Reference (optional) I38023027 8.220 s Nov 16 2018 MiTek Industries, Inc. Fri Aug 2 10:25:54 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jAXtJ2ozokt8tlXqi1fHBQyGc1j-P?ujK4HsQf3vtrZi4YHrukAiAPxjNkwJvlGCahyrvzx Scale = 1:19.9 1 2 3 4 2x4 3x4 2x4 2x4 0-0-5 0-0-5 6-10-7 6-10-2 3-5-3 3-5-3 6-10-7 3-5-3 0-0-42-10-60-0-410.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.33 0.21 0.03 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 14 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=143/6-9-13, 3=143/6-9-13, 4=217/6-9-13 Max Horz 1=-61(LC 4) Max Uplift 1=-21(LC 7), 3=-25(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 2,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Shadow_Wood Truss V16 Truss Type Valley Qty 1 Ply 1 4 Shadow Wood Job Reference (optional) I38023028 8.220 s Nov 16 2018 MiTek Industries, Inc. Fri Aug 2 10:25:55 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jAXtJ2ozokt8tlXqi1fHBQyGc1j-uBS5YQHUBzBmV_8ueGo4Ryix5pF86BgS8P?l67yrvzw Scale: 1"=1' 1 2 3 2x4 2x4 2x4 0-0-5 0-0-5 4-5-10 4-5-5 2-2-13 2-2-13 4-5-10 2-2-13 0-0-41-10-60-0-410.00 12 Plate Offsets (X,Y)-- [2:0-2-0,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.13 0.33 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 8 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-5-10 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=156/4-5-0, 3=156/4-5-0 Max Horz 1=-38(LC 4) Max Uplift 1=-6(LC 6), 3=-6(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 2,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Shadow_Wood Truss V17 Truss Type Valley Qty 1 Ply 1 4 Shadow Wood Job Reference (optional) I38023029 8.220 s Nov 16 2018 MiTek Industries, Inc. Fri Aug 2 10:25:55 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jAXtJ2ozokt8tlXqi1fHBQyGc1j-uBS5YQHUBzBmV_8ueGo4RyiynpKV6BgS8P?l67yrvzw Scale = 1:7.1 1 2 3 2x4 2x4 2x4 2-0-8 2-0-8 2-0-13 0-0-5 1-0-7 1-0-7 2-0-13 1-0-7 0-0-40-10-60-0-410.00 12 Plate Offsets (X,Y)-- [2:0-2-0,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.02 0.05 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 3 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-0-13 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=60/2-0-4, 3=60/2-0-4 Max Horz 1=-14(LC 4) Max Uplift 1=-2(LC 6), 3=-2(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 2,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Shadow_Wood Truss V19 Truss Type Valley Qty 1 Ply 1 4 Shadow Wood Job Reference (optional) I38023030 8.220 s Nov 16 2018 MiTek Industries, Inc. Fri Aug 2 10:25:56 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jAXtJ2ozokt8tlXqi1fHBQyGc1j-MO0TlmI6yGJd68j5CzJJz9F4uCd0rewcN3lJeZyrvzv Scale: 3/4"=1' 1 2 3 2x4 2x4 2x4 3-1-11 3-1-11 0-0-42-7-610.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.25 0.16 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 7 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-1-11 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=110/3-1-6, 3=110/3-1-6 Max Horz 1=69(LC 5) Max Uplift 3=-24(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 2,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Shadow_Wood Truss V21 Truss Type Valley Qty 1 Ply 1 4 Shadow Wood Job Reference (optional) I38023031 8.220 s Nov 16 2018 MiTek Industries, Inc. Fri Aug 2 10:25:56 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jAXtJ2ozokt8tlXqi1fHBQyGc1j-MO0TlmI6yGJd68j5CzJJz9Fz8CZhrewcN3lJeZyrvzv Scale = 1:23.4 1 2 32x4 2x4 2x4 4-11-2 4-11-2 0-0-44-1-410.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.68 0.44 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 12 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-11-2 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=181/4-10-13, 3=181/4-10-13 Max Horz 1=114(LC 5) Max Uplift 3=-40(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 2,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Shadow_Wood Truss V22 Truss Type Valley Qty 1 Ply 1 4 Shadow Wood Job Reference (optional) I38023032 8.220 s Nov 16 2018 MiTek Industries, Inc. Fri Aug 2 10:25:57 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jAXtJ2ozokt8tlXqi1fHBQyGc1j-qaarz6JkjaRUkIIHlhqYWNoBxcxta5AlbjUsA?yrvzu Scale = 1:20.6 1 2 3 2x4 2x4 2x4 4-2-11 4-2-11 0-0-43-6-410.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.49 0.31 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 10 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-2-11 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=153/4-2-6, 3=153/4-2-6 Max Horz 1=96(LC 5) Max Uplift 3=-34(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 2,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Shadow_Wood Truss V23 Truss Type Valley Qty 1 Ply 1 4 Shadow Wood Job Reference (optional) I38023033 8.220 s Nov 16 2018 MiTek Industries, Inc. Fri Aug 2 10:25:58 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jAXtJ2ozokt8tlXqi1fHBQyGc1j-Im8DASKMUuZLMStTJOLn2aKOD0IkJXQuqNEQjSyrvzt Scale = 1:17.7 1 2 3 2x4 2x4 2x4 3-6-5 3-6-5 0-0-42-11-410.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.33 0.21 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 8 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-6-5 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=125/3-6-0, 3=125/3-6-0 Max Horz 1=79(LC 5) Max Uplift 3=-27(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 2,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Shadow_Wood Truss V24 Truss Type GABLE Qty 1 Ply 1 4 Shadow Wood Job Reference (optional) I38023034 8.220 s Nov 16 2018 MiTek Industries, Inc. Fri Aug 2 10:25:59 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jAXtJ2ozokt8tlXqi1fHBQyGc1j-mzhbNoL_FBhCzcRgt6t0botReQbv2_f231zzFuyrvzs Scale = 1:50.1 Sheet Front Full Sheathing 1 Ply 7/16OSB81 2 3 4 5 6 11 10 9 8 7 3x8 3x8 4x6 4x6 3x8 3x8 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 0-1-132-0-0 3-0-04-4-6 4-4-6 5-1-8 0-9-2 -0-11-0 0-11-0 0-9-2 0-9-2 4-4-6 3-7-3 5-1-8 0-9-2 6-0-8 0-11-0 6-2-16-7-146-9-116-2-16-7-1410.00 12 Plate Offsets (X,Y)-- [2:0-4-9,Edge], [5:0-4-9,Edge], [7:0-3-8,Edge], [22:0-1-8,0-1-0], [28:0-1-8,0-1-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-R 0.86 0.40 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.02 0.03 0.00 (loc) 5-6 5-6 7 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 120 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-1-8 oc purlins, except end verticals, and 2-0-0 oc purlins: 3-4. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 5-1-8. (lb) - Max Horz 11=-215(LC 4) Max Uplift All uplift 100 lb or less at joint(s) 9 except 11=-316(LC 4), 7=-534(LC 5), 8=-446(LC 4), 10=-268(LC 5) Max Grav All reactions 250 lb or less at joint(s) 9 except 11=261(LC 10), 7=448(LC 4), 8=480(LC 5), 10=294(LC 4) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(10-11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) -0-11-0 to 6-0-8 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 9 except (jt=lb) 11=316, 7=534, 8=446, 10=268. 8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 2,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Shadow_Wood Truss V25 Truss Type VALLEY Qty 1 Ply 1 4 Shadow Wood Job Reference (optional) I38023035 8.220 s Nov 16 2018 MiTek Industries, Inc. Fri Aug 2 10:26:00 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jAXtJ2ozokt8tlXqi1fHBQyGc1j-E9F_b8Lc0Vp3bm0sRpOF7?Qj8q?SnOjBIhjWnKyrvzr Scale = 1:50.6 1 2 3 4 5 8 7 6 2x4 3x4 4x6 3x4 2x4 3x6 2-6-12 2-6-12 5-1-8 2-6-12 -0-11-0 0-11-0 2-4-6 2-4-6 2-6-12 0-2-6 2-9-2 0-2-7 5-1-8 2-4-6 6-0-8 0-11-0 5-7-17-6-115-7-110.00 12 Plate Offsets (X,Y)-- [3:0-0-0,0-0-1] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.43 0.13 0.20 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.00 0.00 0.00 (loc) 4-5 4-5 6 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 37 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x3 SPF No.2 WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-1-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)8=115/5-1-8, 6=115/5-1-8, 7=286/5-1-8 Max Horz 8=-234(LC 4) Max Uplift 8=-134(LC 4), 6=-134(LC 5), 7=-31(LC 7) Max Grav 8=164(LC 5), 6=164(LC 4), 7=286(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 7 except (jt=lb) 8=134, 6=134. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 2,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Shadow_Wood Truss V26 Truss Type Valley Qty 1 Ply 1 4 Shadow Wood Job Reference (optional) I38023036 8.220 s Nov 16 2018 MiTek Industries, Inc. Fri Aug 2 10:26:00 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jAXtJ2ozokt8tlXqi1fHBQyGc1j-E9F_b8Lc0Vp3bm0sRpOF7?QkUq?SnNsBIhjWnKyrvzr Scale = 1:47.2 1 2 3 4 5 8 7 69 2x4 3x4 4x6 3x4 2x4 3x6 5-1-8 5-1-8 -0-11-0 0-11-0 2-6-12 2-6-12 4-11-0 2-4-4 5-1-8 0-2-8 6-0-8 0-11-0 5-0-17-1-115-0-110.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.34 0.13 0.26 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.00 0.00 0.00 (loc) 5 4-5 6 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 35 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x3 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-1-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)8=124/5-1-8, 6=124/5-1-8, 7=268/5-1-8 Max Horz 8=-214(LC 4) Max Uplift 8=-106(LC 4), 6=-106(LC 5), 7=-34(LC 6) Max Grav 8=139(LC 5), 6=139(LC 4), 7=268(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 7 except (jt=lb) 8=106, 6=106. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 2,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Shadow_Wood Truss V27 Truss Type Valley Qty 1 Ply 1 4 Shadow Wood Job Reference (optional) I38023037 8.220 s Nov 16 2018 MiTek Industries, Inc. Fri Aug 2 10:26:01 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jAXtJ2ozokt8tlXqi1fHBQyGc1j-iLpMoTMFnpxwDvb2_XvUgDysGDJgWruLWLS4Jnyrvzq Scale = 1:43.5 1 2 3 4 5 8 7 6 3x6 3x6 4x6 3x6 3x6 2x4 5-1-8 5-1-8 -0-11-0 0-11-0 2-6-12 2-6-12 5-1-8 2-6-12 6-0-8 0-11-0 4-5-16-6-114-5-110.00 12 Plate Offsets (X,Y)-- [2:0-3-0,0-1-4], [4:0-3-0,0-1-4], [6:Edge,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-R 0.53 0.26 0.21 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.00 0.00 (loc) 4 4 6 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 28 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-1-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)8=200/5-1-8, 6=200/5-1-8, 7=313/5-1-8 Max Horz 8=192(LC 5) Max Uplift 8=-112(LC 7), 6=-112(LC 6) Max Grav 8=202(LC 10), 6=202(LC 11), 7=313(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 8=112, 6=112. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 2,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Shadow_Wood Truss V28 Truss Type Valley Qty 1 Ply 1 4 Shadow Wood Job Reference (optional) I38023038 8.220 s Nov 16 2018 MiTek Industries, Inc. Fri Aug 2 10:26:02 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jAXtJ2ozokt8tlXqi1fHBQyGc1j-AYNk0pNtY63nr3AFYEQjDQV37ddHFJuUl?CdsDyrvzp Scale = 1:39.8 1 2 3 4 5 8 7 6 3x6 3x6 4x6 3x6 3x6 2x4 5-1-8 5-1-8 -0-11-0 0-11-0 2-6-12 2-6-12 5-1-8 2-6-12 6-0-8 0-11-0 3-10-15-11-113-10-110.00 12 Plate Offsets (X,Y)-- [2:0-3-0,0-1-4], [4:0-3-0,0-1-4], [6:0-2-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-R 0.39 0.36 0.16 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.00 0.00 (loc) 4 4 6 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 23 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x3 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-1-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)8=203/5-1-8, 6=203/5-1-8, 7=306/5-1-8 Max Horz 8=-174(LC 4) Max Uplift 8=-106(LC 7), 6=-106(LC 6) Max Grav 8=205(LC 10), 6=205(LC 11), 7=306(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 8=106, 6=106. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 2,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Shadow_Wood Truss V29 Truss Type VALLEY Qty 1 Ply 1 4 Shadow Wood Job Reference (optional) I38023039 8.220 s Nov 16 2018 MiTek Industries, Inc. Fri Aug 2 10:26:03 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jAXtJ2ozokt8tlXqi1fHBQyGc1j-fkx6D9OVIQBeSDlR6xxyle2Gi1?K_n3e_fxBOfyrvzo Scale = 1:34.2 1 2 3 4 5 8 7 6 2x4 3x6 4x6 3x6 2x4 2x4 5-1-8 5-1-8 -0-11-0 0-11-0 2-6-12 2-6-12 5-1-8 2-6-12 6-1-8 1-0-0 3-0-55-1-153-0-510.00 12 Plate Offsets (X,Y)-- [2:0-3-0,0-1-4], [4:0-3-0,0-1-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-R 0.28 0.25 0.10 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.00 0.00 (loc) 5 4-5 6 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 22 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x3 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-1-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)8=163/5-1-8, 6=170/5-1-8, 7=187/5-1-8 Max Horz 8=-148(LC 4) Max Uplift 8=-96(LC 7), 6=-94(LC 6) Max Grav 8=165(LC 10), 6=172(LC 11), 7=187(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8, 6. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 2,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Shadow_Wood Truss V30 Truss Type VALLEY Qty 1 Ply 1 4 Shadow Wood Job Reference (optional) I38023040 8.220 s Nov 16 2018 MiTek Industries, Inc. Fri Aug 2 10:26:03 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jAXtJ2ozokt8tlXqi1fHBQyGc1j-fkx6D9OVIQBeSDlR6xxyle2I8104_ote_fxBOfyrvzo Scale = 1:28.1 1 2 3 4 5 8 7 6 2x4 3x4 4x6 3x4 2x4 2x4 5-1-8 5-1-8 -0-11-0 0-11-0 2-6-12 2-6-12 5-1-8 2-6-12 6-1-8 1-0-0 2-0-54-1-152-0-510.00 12 Plate Offsets (X,Y)-- [2:0-2-0,0-1-4], [4:0-2-0,0-1-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-R 0.19 0.13 0.05 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.00 0.00 (loc) 5 5 6 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 19 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x3 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-1-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)8=165/5-1-8, 6=172/5-1-8, 7=183/5-1-8 Max Horz 8=-114(LC 4) Max Uplift 8=-86(LC 6), 6=-90(LC 7) Max Grav 8=167(LC 10), 6=174(LC 11), 7=183(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8, 6. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 2,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Shadow_Wood Truss V31 Truss Type VALLEY Qty 1 Ply 1 4 Shadow Wood Job Reference (optional) I38023041 8.220 s Nov 16 2018 MiTek Industries, Inc. Fri Aug 2 10:26:04 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jAXtJ2ozokt8tlXqi1fHBQyGc1j-7wVURVO73jJV4NKdgfSBIraTuRN5jFTnCJhkw5yrvzn Scale = 1:21.7 1 2 3 4 5 8 7 6 2x4 2x4 4x6 2x4 2x4 2x4 5-1-8 5-1-8 -0-11-0 0-11-0 2-6-12 2-6-12 5-1-8 2-6-12 6-1-8 1-0-0 1-0-53-1-151-0-510.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-R 0.19 0.08 0.03 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.00 0.00 (loc) 5 5 6 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 17 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x3 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-1-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)8=171/5-1-8, 6=178/5-1-8, 7=171/5-1-8 Max Horz 8=-80(LC 4) Max Uplift 8=-81(LC 6), 6=-85(LC 7) Max Grav 8=172(LC 10), 6=178(LC 1), 7=171(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8, 6. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 2,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Shadow_Wood Truss V32 Truss Type Valley Qty 1 Ply 1 4 Shadow Wood Job Reference (optional) I38023042 8.220 s Nov 16 2018 MiTek Industries, Inc. Fri Aug 2 10:26:05 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jAXtJ2ozokt8tlXqi1fHBQyGc1j-b63terPlq1RMiXvpDMzQq37dnrjqSirwRzQHSYyrvzm Scale: 3/4"=1' 1 2 3 4 2x4 3x4 2x4 2x4 0-0-5 0-0-5 5-2-4 5-2-0 2-7-2 2-7-2 5-2-4 2-7-2 0-0-42-1-150-0-410.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.18 0.12 0.02 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 10 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-2-4 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=105/5-1-11, 3=105/5-1-11, 4=159/5-1-11 Max Horz 1=-45(LC 4) Max Uplift 1=-15(LC 7), 3=-18(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 2,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Shadow_Wood Truss V33 Truss Type Valley Qty 1 Ply 1 4 Shadow Wood Job Reference (optional) I38023043 8.220 s Nov 16 2018 MiTek Industries, Inc. Fri Aug 2 10:26:06 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jAXtJ2ozokt8tlXqi1fHBQyGc1j-3JcFrBQNbLZDJhU0n4VfNGfqfE3AB9O4gdAr?_yrvzl Scale = 1:8.6 1 2 3 2x4 2x4 2x4 2-9-8 2-9-8 1-4-12 1-4-12 2-9-8 1-4-12 0-0-41-1-150-0-410.00 12 Plate Offsets (X,Y)-- [2:0-2-0,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.04 0.11 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 5 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-9-8 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=89/2-9-8, 3=89/2-9-8 Max Horz 1=-21(LC 4) Max Uplift 1=-3(LC 6), 3=-3(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 2,2019 PRODUCT CODE APPROVALSLATERAL BRACING LOCATIONIndicates location where bearings(supports) occur. Icons vary butreaction section indicates jointnumber where bearings occur.Min size shown is for crushing only.Indicated by symbol shown and/orby text in the bracing section of theoutput. Use T or I bracingif indicated.The first dimension is the plate width measured perpendicular to slots. Second dimension isthe length parallel to slots.Center plate on joint unless x, yoffsets are indicated.Dimensions are in ft-in-sixteenths.Apply plates to both sides of trussand fully embed teeth.1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI.2. Truss bracing must be designed by an engineer. For wide truss spacing, individual lateral braces themselves may require bracing, or alternative Tor I bracing should be considered.3. Never exceed the design loading shown and never stack materials on inadequately braced trusses.4. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties.5. Cut members to bear tightly against each other.6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI 1.7. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI 1.8. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication.9. Unless expressly noted, this design is not applicable for use with fire retardant, preservative treated, or green lumber.10. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection.11. Plate type, size, orientation and location dimensions indicated are minimum plating requirements.12. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified.13. Top chords must be sheathed or purlins provided at spacing indicated on design.14. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted.15. Connections not shown are the responsibility of others.16. Do not cut or alter truss member or plate without prior approval of an engineer.17. Install and load vertically unless indicated otherwise.18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use.19. Review all portions of this design (front, back, words and pictures) before use. Reviewing pictures alone is not sufficient.20. Design assumes manufacture in accordance with ANSI/TPI 1 Quality Criteria.Failure to Follow Could Cause PropertyDamage or Personal Injury (Drawings not to scale)© 2012 MiTek® All Rights ReservedMiTek Engineering Reference Sheet: MII-7473 rev. 10/03/2015edge of truss.from outside"16/1-0ICC-ES Reports:ESR-1311, ESR-1352, ESR1988ER-3907, ESR-2362, ESR-1397, ESR-3282JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISEAROUND THE TRUSS STARTING AT THE JOINT FARTHEST TOTHE LEFT.CHORDS AND WEBS ARE IDENTIFIED BY END JOINTNUMBERS/LETTERS.W 4 - 6 W3-6W3 - 7 W2-7W1-7C1-8 C5-6C6-7C7-8C4-5 C3-4C2-3C1-2TOP CHORD TOP CHORD 87654321BOTTOM CHORDSTOP CHORDSBEARING4 x 4PLATE SIZEThis symbol indicates the required direction of slots inconnector plates."16/1For 4 x 2 orientation, locateplates 0- 1"4/3PLATE LOCATION AND ORIENTATIONSymbolsNumbering SystemGeneral Safety Notes *Plate location details available in MiTek 20/20software or upon request.Industry Standards:ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction.DSB-89: Design Standard for Bracing.BCSI: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses.6-4-8WEBSTrusses are designed for wind loads in the plane of the truss unless otherwise shown.Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others.dimensions shown in ft-in-sixteenths