Subject to compliance with all regulations
of State and Local Codes
City Bf Camel
x n
�1vmlD 01041\cai
DATE: \ 09/05/19
re PROPOSED FLOOR PLAN
2
3
4
T =110)
5
APPLICABLE CODES: I LIFE SAFETY PLAN LEGEND
2014 INDIANA BUILDING CODE (2012 INTERNATIONAL BUILDING CODE)
2010 INDIANA ENERGY CONSERVATION CODE (675-ISE 19-4)
2014 INDIANA FIRE CODE (2012 INTERNATIONAL FIRE CODE) ❑ ExIST1NGBUIDINGABEA
2012 INDIANA PLUMBING CODE (2006 INDIANA PLUMBING CODE WITH 2O12
AMENDMENTS)
2009INDIANA ELECTRICAL CODE (2008 NFPA 70)
2014 INDIANA MECHANICAL CODE (2012 INTERNATIONAL MECHANICAL COOS) ExISUNG BUILDING OF RENOVATION
2014 INDIANA FUEL GAS CODE (2012 INTERNATIONAL FUEL GAS CODE)
2000 LIFE SAFETY CODE, CHAPTER 23 (NFPA 101)
PROJECT LOCATION:
EXT
BUILDING AMMON EXIT
14390 CLAY TERRACE BLVD., #150
CARMEL, IN 46032
E EXT
BxlsnrvO6UILDING ExR
OCCUPANCY:
BUILDING ADDITION FIFE EMINCAIISHER
A-2 OCCUPANCY (SEC. 303.1.1)
PBC
LOCATIONS (ME SHEET Alan
•
I HOUR MORE BARRIER
SQUARE
FOOTAGE:
• •
2 HOUR MORE BORFUR,FIFE BARRIER
40,200 SF TOTAL EXISTING BUILDING
3,064 SF REMODELED
• •
2 HOUR HIRE BARRIER
HEIGHT:
- - - wimMO
ERESISTAM gPoLO R
BUILDING IS 2 STORY
—
SMq(E Po:SISTgNTHAZARWSR00M
•wiiiiiiiiiiiiiiwIHOUR
CORRIDOR
WIDTH
OF
EXITS:
- - —
21HOURCORRIDOR
EXIT DOOR WIDTH PROVIDED AT THE RATE OF 0.15INCHES
PER OCCUPANT. (SEC. 1003.2.3)
win min min min aiin
SMOKERESISTANTWAFT
CONSTRUCTION TYPE:
---
IHOUR SHAFT
TYPE II-B
winiin • • aiiiiiiin
2HOUR SHAFT
FIRE SUPPRESSION SYSTEM:
2 HOUR EXIT ENCLOSURE
' ' ' y
PATH aF BO#ss
FIRE SUPPRESSION SYSTEM PROVIDED(903.2.1.2)
FIRE RESISTIVE CORRIDORS:
NOT REQUIRED
SMOKE RESISTIVE CORRIDOR
DOORS:
NOT REQUIRED
HAZARDOUS ROOMS:
NONE
EXIT ACCESS TRAVEL DISTANCE:
EXIT ACCESS TRAVEL DISTANCE: NOT TO EXCEED 300 FEET.
DEAD END EXIT ACCESS: NOT TO EXCEED 50 FEET.
OCCUPANT LOAD:
SEATING=1170CCUR
KITCHENISTAFF = 10 OCCOP.
TOTAL =127 OCCUR.
PLUMBING COUNT:
COUNTS BASED ON 127 TOTAL OCCUPANTS
WATERCLOSETS: 1 PER 75 OCCUPANTS (MEN 8 WOMEN)
2 REQUIRED, 2 PROVIDED (EXISTING)
LAVATORIES: 1 PER 200 OCCUPANTS (MEN 8 WOMEN)
1 REQUIRED, 2 PROVIDED (EXISTING)
THERE ARE 2 EXISTING RESTROOMS IN THE SPACE THAT
COMPLY WITH THE REQUIREMENTS FOR MINIMUM NUMBER
OF REQUIRED PLUMBING FIXTURES
ALARMS / FIRE DETECTION:
A MANUAL FIRE ALARM SYSTEM IS NOT REQUIRED (907.2.1)
ACCESSIBILITY:
PER BUILDING OCCUPANCY I ANSI REQUIREMENTS
b
7
Pl
1:1
C
D
E
m
o
STUDIO
THREE=
N
DESIGN a
www. studio3design.net
Phone:(317) 595.1000
Fax: (317) 572.1236
8604 Allisonville Road, Suite 330
Indianapolis, IN 46250
J
LLI
° O
`>
W w cs N
M
Jm0
v
O
Z
A.-
s = A
J V w
Q
f6
Q
Q U U U
O
LLI M
L.L. r�
Q
v
PROJECT NUMBER:
19015
DATE:
07-08-2019
yrWm Ach"We
Ri
CERTIFICATION:
MIY.IIIIMI
E C 9AAF
Kp
No.
*'I, 910109 r' * m
9lAIE6
gACFI
ITEM
M
SHEET DESCRIPTION:
LIFE SAFETY
PLAN
SHEET N VMBFIZ
A002
THIS DRAWINGS IS THE
PROPERTY OF STUDIO 3 DESIGN,
INC. ALL RIGHTS RESERVED