HomeMy WebLinkAbout10. TYPICAL ACCESSIBILITY DETAILS ADA1.127" MAX
CONTROLS
DETAIL 8
112"=1A.
SPIN
FtX,
:10o
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and Local Codes
City of Camel
�VT�32U�8*T41WML_
DATE: 09/06/19
NOTES:
I. TOP OF GRIPPING SURFACE 33"TO 36'MAX
- SEE NOTES BELOW MIRROR MOUNTED @ 40' FIRE ALARM
2. 12' MINIMUM CLEAR ABOVE GRAB BAR ARE MAX TO BOTTOM OF
REFLECTING SURFACE THERMOSTAT
LAVATORY SWITCHES
VERTICAL SS GRAB BAR INSULATE HOT WATER PULL STATION
39" TO41" R DRAIN PIPES
TOILET SEAT COVER
42" SS GRAB BAR DISPENSER SHALL BE
MOUNTED IY' (MIN) SPIN MIN PROJECTION
6" TO 12" MAX BELOW GRAB RAIL FROM WALL URINAL
36" SS GRAB BAR r 37 — C7 0 e —
Y P'
DRYER
x OUTLETS (VON)
33'(EXCEPT@TANK £ PAPER TOWEL DISPENSER gyp, 1/ter
D U o IJ
z T
TOILETS, WHICH �^ Trn m a F = a mW =1 SHALL BE 36" £
CONTROLS MOUNTED ON
WIDE SIDE OF TOILET AREA
ACCSIBL FOUTE
/L LEAK
/
0"
CLEAR
L
15" TO 48" AFF FOR
OPERABLE OPENING 6' MAX DEPTH X 30' MIN
W)0 OBSTRUCTION WIDTH TOE CLEARANCE
FROM GRAB BAR
8' MIN DEPTH X 304 MIN
WIDTH KNEE SPACE
DETAIL 1
U2-=1'-B'
i
V
6
NOTE: MAINTAIN 44" MIN CLEAR AISLE
EGRESS PATHS TO EXIT DOORS.
9 DETAIL 6
6' = I'-0' 112' = 1'-0'
10
114'=ILO'
PROTRUDING OBJECT
FREESTANDING OBJECT
MOUNTED ON POSTS OR
PYLON MAY OVERHANG
IT MAX FROM 27" TO 8V
ABOVE FINISH FLOOR
OBJECT PROJECTION FROM
WALL BETWEEN 27" TO 8V
ABOVE FINISH FLOOR SHALL
PROTRUDE NO MORE THAN 4"
OBJECT PROJECTION FROM WALL
LESS THAN 27' ABOVE FINISH FLOOR
MAY PROTRUDE ANY AMOUNT
FLOOR SHALL BE SLIPRESISTANT
SURFACE AND LEVEL WITH MAX
Y" CHANGE IN LEVEL
WMIN CLEAR
ACCESSIBLE ROUTE
z
£
$
DETAIL 7
112' = IAm
CLEAR
FLOOR
£
SPACE
m
48" MIN
STUD WALL
P X 6- BLOCKING (OMIT BLOCKING AT
MASONRY OR CONCRETE WALL)
GRAB BAR SHALL BE IY." TO T
MAX OUTSIDE DIA TYPICAL
2 Y" X 3" EXPANSION ANCHORS
AT MASONRY OR CONCRETE WALL.
2-#10 X 2' SCREWS AT WOOD OR
STEEL STUD WALL -TYPICAL.
DETAIL 5
3' = 1'-0'
2
U2' = 1'-0'
DETAIL 3
0
O<z
U
d£p
TYPICAL ADA INFO
WATER CLOSET: WATER CLOSETS SHALL BE IT TO WAR WHEN
MEASURED TO THE TOP OF THE TOILET SEAT AND THE CENTER FOR THE
FIXTURE SHALL BE 18' FROM ONE WALL WITH A CLEAR FLOOR SPACE OF
60' WIDE AND 59' DEEP FOR FLOOR MOUNT AND 56' DEEP FOR WALL
MOUNT.
SINK: SINK SHALL BE MOUNTED WITH THE RIM OR COUNTER NO HIGHER
THAN MAT PROVIDE A CLEARANCE OF AT LEAST 29" TO THE BOTTOM
OF THE APRON WITH AN 8"X27" KNEE SPACE AND 6"X9" TOE SPACE.
EXPOSED HOT WATER AND DRAIN PIPES UNDER SINKS SHALL BE
INSULATED. FAUCETS SHALL BE LEVER -OPERATED, PUSH -TYPE AND
MOTION SENSOR.
URINALS. URINALS SHALL BE STALLTYPE OR WALL HUNG WITH THE RIM
AT A MAXIMUM OF 11' AFF AND A 30' X 48" CLEAR FLOOR SPACE.
GRAB BARS: GRAB BARS SHALL BE 33" TO 36" ARE THE GRAB BAR BEHIND
THE WATER CLOSET SHALL BE 36" LONG AND NO MORE THAN 6" OF OF
THE SIDE WALL. THE SIDE WALL GRAB BAR SHALL SE 42m LONG AND IT
OFF THE BACK WALL
MIRROR: MIRRORS SHALL BE MOUNTED SO THE BOTTOM OF THE
REFLECTING SURFACE IS NO MORE THAN PION AFF.
PAPER TOWELIDRYER: PAPER TOWED DRYERS SHALL BE MOUNTED NO
HIGHER THAN 48' AFF.
SOAP DISPENSER: SOAP DISPENSERS SHALL BE MOUNTED NO HIGHER
THAN48'ARE
TOILET PAPER TOILET PAPER DISPENSERS SHALL BE INSTALLED WITHIN 36"
MAX OF THE BACK WALL
EAST CARMEL DRIVE
I.J PROJECT LOCATION
N KEY PLAN
ORTH
CURRAN
ARCHITECTURE
6925 EAST 96TH ST., SUITE 105
INDIANAPOLIS, IN 46250
0 :: 317. 288.0681
IF :: 317. 288. 0753
,oyt,P�NE�M ea o�RPy%
No. y
• AR19600043'. •
STAR Q _
THIS DRAWING AND THE IDEAS, DESIGNS
AND CONCEPTS CMTAINED HERON ARE
THE EXCLUSIVE INTELLECTUAL PROPERTY
OF CURRAN ARCHITECTURE, AND ARE NOT
TO BE USED OR REPRODUCED, WHOLE OR
IN PART, WITHOUT THE WRITTEN
CONSENT OF CURRAN ARCHITECTURE.
0 C nRK.HT 2017, CURRAN ARCHITECTURE
ELEVATOR ADDITION
101 EAST CARMEL DRIVE
CARMEL, IN
PERMIT SET
170053
7-10-19
TYPICAL ACCESSIBILITY
DETAILS
ADAI.I