Loading...
HomeMy WebLinkAbout12. DEMO FLOOR PLAN D1.1RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Camel �VT�T21�8*VAWML DATE: 09/06/19 OPEN TO BELOW O trx0 CIE � 3�0 O 0 �I�IKI� TaBEL HALLWAY L/ �7� AF-------------- z SECOND FLOOR DEMO PLAN 3 �N OFFICE LOWER LEVEL DEMO PLAN N FIRST FLOOR DEMO PLAN 2 N 1:8- 1'-0" KEYED NOTES GEN. DEMO NOTES I. REMOVE SECTION OF CONCRETE TO FLOOR TO CREATE A. DASHED LINES INDICATE EXISTING ITEMS TO BE REMOVED. OPENING FOR NEW ELEVATOR. COORDINATE WITH UNLESS NOTED OTHERWISE CONTRACTOR SHALL BE STRUCTURAL DWGS. FOR STRUCTURE BELOW CONCRETE RESPONSIBLE FOR THE OFF —SITE DISPOSAL OF ALL FLOOR. VERIFY EXTENTS IN FIELD. DEMOLITION ITEMS. 2. REMOVE ALL FLOORING THIS AREA, PREP FLOOR TO RECEIVE NEW MATERIAL. COORDINATE NEW FINISH SELECTION WITH OWNER. 3. EXISTING RAILING TO BE REMOVED. REPAIR AND PREP AFFECTED WALL AND FLOOR TO RECEIVE NEW MATERIAL. 4. EXISTING STAIRS TO BE REMOVE IN ITS ENTIRETY. REMOVE ALL FLOOR ANCHORS AS REQUIRED. REPAIR AND PREP FLOOR TO RECEIVE NEW MATERIAL. VERIFY EXTENTS IN FIELD. 5. REMOVE EXISTING CONCRETE SLAB AND EXCAVATE 5'-0" BELOW TOP OFF EXISTING SLAB. COORDINATE REQUIRED ELEVATOR PIT DEPTH WITH STRUCTURAL DWGS. AND ELEVATOR MANUFACTURERS SPECIFICATIONS, B. RELOCATED ITEMS SHALL BE CLEANED AND PLACED IN STORAGE, PER OWNERS DIRECTIONS UNTIL ITEMS ARE READY TO BE REINSTALLED. IF ITEM IS DAMAGED DURING DEMOLITION OR RELOCATION IT SHALL BE REPAIRED OR REPLACED WITH NEW ITEM AS APPROVED BY OWNER AT NO EXPENSE TO OWNER. C. DEMOLITION SHALL BE DONE WITH OUT DAMAGE TO EXISTING CONSTRUCTION TO REMAIN. WHERE SUCH DAMAGE OCCURS PATCH, REPAIR, OR RESTORE WALLS, FLOORS, CEILINGS, ETC. TO MATCH EXISTING. PROVIDESHORING, BRACING, OR SUPPORT AS REQUIRED TO PREVENT MOVEMENT OR SETTLEMENT OF EXISTING CONSTRUCTION. D. CONTRACTOR SHALL BE RESPONSIBLE FOR THE COORDINATION OF DEMOLITION ITEMS WITH THE OTHER TRADES PRIOR TO THE START OF DEMO WORK. E. REMOVE ALL EXISTING CONSTRUCTION, ITEMS AND FINISHES MADE OBSOLETE BY, OR IN CONFLICT WITH NEW CONSTRUCTION— VERIFY WITH ARCH. REMOVE WIRING BACK TO SOURCE AT ALL OUTLETS ETC. MADE OBSOLETE BY WALL REMOVAL OR ANY OTHER NEW CONSTRUCTION. F. WHERE EXISTING WALLS, BULKHEADS, OR FINISHES ARE REMOVED OR PARTIALLY DEMOLISHED, EACH TRADE SHALL BE RESPONSIBLE FOR PATCHING OR REFINISHING OF EXISTING CONSTRUCTION REQUIRED BY THAT TRADES WORK ON THIS PROJECT. THIS WORK MUST BE DONE IN A MANNER WHICH WILL ACCEPT NEW FINISHES. G. ALL CONTRACTORS ARE RESPONSIBLE FOR REMOVAL AND REPLACEMENT OF CEILING GRID AND/OR TILES IN ANY AREA WHERE THEY NEED ACCESS AND THE EXISTING CEILING IS TO REMAIN. UNLESS OTHERWISE NOTED, CONTRACTOR SHALL REPLACE ANY CEILING TILES OR GRID DAMAGED IN THIS PROCESS, H. AT THE OWNER'S REQUEST SALVAGED ITEMS SHALL BE TURNED OVER TO THE OWNER OR STORED IN AN AREA DESIGNATED BY THE OWNER. I. DIMENSIONS SHOWN FOR EXISTING CONSTRUCTION TO BE DEMOLISHED ARE APPROXIMATE AND ARE INTENDED TO GIVE A GENERAL IDEA OF WORK TO BE REMOVED OR WORK TO BE TEMPORARILY REMOVED IN ORDER TO COMPLETE NEW CONSTRUCTION. COORDINATE DEMOLITION WORK WITH DESIGN INTENT OF NEW CONSTRUCTION TO PROVIDE ADEQUATE AREA FOR THIS WORK. J. CONTRACTOR MUST FIELD VERIFY ALL AREAS AND/OR WORK TO BE DEMOLISHED PRIOR TO BEGINNING WORK. CONTRACTOR MUST COORDINATE WITH ARCHITECT ANY DIFFERENCES BETWEEN FIELD VERIFIED CONDITIONS AND/OR CONSTRUCTION, AND WHAT IS SHOWN ON DEMOLITION DRAWINGS. K. PRIOR TO BEGINNING DEMOLITION, DUST CONTROL BARRIERS SHALL BE CONSTRUCTED TO PREVENT THE SPREAD OF DUST INTO SURROUNDING AREAS. L. EXITING FROM STRUCTURE, IF REQUIRED TO PASS THROUGH DEMOLITION AREA(S), SHALL HAVE APPROVED BARRIERS ETC., TO INSURE SAFETY OF PUBLIC. M. WHEN APPLICABLE, REFER TO STRUCTURAL, MECHANICAL, ELECTRICAL AND PLUMBING DEMO DRAWINGS FOR ADDITIONAL DEMOLITION REQUIREMENTS AND INFO. N. REMOVE AND REINSTALL ALL EQUIPMENT OR CONSTRUCTION ON WALLS REQUIRING NEW FINISHES. 0. REFINISH ENTIRE SURFACES AS NECESSARY TO PROVIDE AN EVEN FINISH, REFINISH ENTIRE ASSEMBLIES. CONTINUOUS SURFACES WILL BE TAKEN TO THE NEAREST INTERSECTION. R REMOVE ALL DIRT, DUST, DEBRIS ETC, DAILY. DO NOT ALLOW REFUSE TO BLOCK CORRIDORS, STAIRS, OR ANY OTHER TRAFFIC AREA. 0. ALL ABANDONED PLUMBING LINES TO BE CAPPED OFF AND TERMINATED BELOW FINISH FLOOR. R. COORDINATE W/ INTERIOR DESIGN DRAWINGS FOR FLOORING FINISHES. EAST CARMEL DRIVE 1..1 PROJECT LOCATION N KEY PLAN ORTH CURRAN ARCHITECTURE 6925 EAST 96TH ST., SUITE 105 INDIANAPOLIS, IN 46250 O :: 317. 288. 0681 F 317. 288. 0753 QN.0.C4,S1CREn No. y. • '. AR1960DO43 • SEAR V EMPIRES THIS DRAWING AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HERBN ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF CURRAN AACHITECTLME, AND ARE NOT TO BE USED OR REPRODUCED, WHOLE OR IN PART, WITHOUT THE WRITTEN CONSENT OF CURRAN ARCHITECTURE. A 0PYRILHT2017,CURVNAR0WTECTURE ELEVATOR ADDITION 101 EAST CARMEL DRIVE CARMEL, IN PERMIT SET 7-10-19 170053 DEMO FLOOR PLAN DI•I