HomeMy WebLinkAboutCS-1 Cover SheetPROJECT PROJECT
LOCATION LOCATION
1p61h 5Lee1 Ipfi ,'
4 Bill,
1 A' 0
' 4 A�..M-�UAF t
431 1 i,-i
µn1961h sued
4\ ^ryt
VICINITY MAP LOCATION MAP
N.T.S. N.T.S.
SHEETINDEX
LEGEND
DENOTES CURRENT SHEET
DENOTES SHEET WAS SUPERCEDED
r
w
m
C
SHEET NO. SHEET TITLE
CS-1 COVER SHEET
CS-2 GENERAL NOTES & TYPICAL DETAILS
CS-3 ACCESSIBILITY PLAN
CS-4 UL LISTINGS
CS-4.1 UL LISTINGS
LS-1 LIFE SAFETY PLAN
ARCHITECTURAL
D-1 DEMOLITION PLAN
D-2 DEMOLITION CEILING PLAN
A-1 FLOOR PLAN
A-1.1 EQUIPMENT PLAN
A-2 REFLECTED CEILING PLAN
A-3 FINISH PLAN
A-4 MILLWORK & DETAILS
PLUMBING
P-1 PLUMBING PLANS,DETAILS, NOTES, LEGEND & SCHEDULE
MECHANICAL
M-1 MECHANICAL DETAILS. NOTES, LEGEND & SCHEDULE
M-2 HVAC PLANS
ELECTRICAL
E-1 ELECTRICAL RISER, PANELS, NOTES, LEGEND & SCHEDULE
E-2 POWER AND ROOF POWER PLAN
RELEASED FOR CONSTRUCTION
"'A .. Subjecttoance d Local all regulaiipns
Lof State and Local Codes
City d Camel
V wb U0+
DATE: 09/06/19
SCOPE OF WORK
TENANT IMPROVEMENT CONSISTING OF THE CONSTRUCTION OF A NEW HAMBURGER RESTAURANT WITHIN AN
EXISTING BUILDING SHELL, TO INCLUDE ALL ELECTRICAL, PLUMBING AND MECHANICAL MODIFICATIONS,
NTERIOR PARTITIONS AND EQUIPMENT NO STRUCTURAL OR STOREFRONT MODIFICATIONS ARE PART OF THE
SCOPE. THIS TENANT IS FULLY EQUIPPED WITH FIRE SPRINKLER.
PROJECT
DIRECTORY
TENANT
CHEEEBURGER ZIONSVILLE, LLC
712 SETTLERS WALK DR.
BROWNSBURG, IN 46112
CONTACT: HIEN B. LY(HELEN)
PH: 317-459-1636 CELL: 317-459-1636
EMAIL: HIENBLY@ICLOUD.COM
LANDLORD
OWNER: CRI WEST CARMEL, LLC(INDIANA CO.)
COMPANY: CASTO
250 CIVIC CENTER DR., STE 500 COLUMBUS, OH 43215
CONTACT: KELLY FENIMORE
PH: 614-227-3466 FAX: 614-221-3076
EMAIL: KFENIMORE@CASTOINFO.COM
GOVERNING AGENCIES CITY OF CARMEL HAMILTON COUNTY HEALTH DEPARTMENT
BUILDING & CODE SERVICES 18030 FOUNDATION DRIVE SUITE
ONECIVICSQUARE NOBLESVILLE, IN 46060
CARMEL, IN 46032 PHONE: 31 T-TT6-8500
317-571-2444 FAX: 317-776-8506
CODE INFORMATION
J 2012 INTERNATIONAL BUILDING CODE W/2014 INDIANA
AMENDMENTS
® 2012 INTERNATIONAL FIRE CODE W/2014 INDIANA
AMENDMENTS
® 2010 INTERNATIONAL ENERGY CONSERVATION CODE
® 2012 INTERNATIONAL FUEL GAS CODE
® 2006 INDIANA PLUMBING CODE W/ 2014 INDIANA
AMENDMENTS
® 2012 INTERNATIONAL MECHANICAL CODE W/2014 INDIANA
AMENDMENTS
® 2008 NATIONAL ELECTRIC CODE W/ 2014 INDIANA
AMENDMENTS
® 2012 ADA STANDARD
CLASSIFICATION OF WORK (IEBC, 2012 CHAPTER 5)
❑ ALTERATION LEVEL 1 -ALTERATIONS INCLUDE THE
REMOVAL AND REPLACEMENT OR THE COVERING OF
EXISTING MATERIALS, ELEMENTS, EQUIPMENT, OR
FIXTURES USING NEW MATERIALS, ELEMENTS,
EQUIPMENT, OR FIXTURES THAT SAVE THE SAME
PURPOSE.
® ALTERATIONLEVEL2- ALTERATIONS INCLUDE THE
RECONFIGURATION OF SPACE, THE ADDITION OR
ELIMINATION OF ANY DOOR OR WINDOW, THE
RECONFIGURATION OR EXTENSION OF ANY SYSTEM, OR
THE INSTALLATION OF ANY ADDITIONAL EQUIPMENT.
❑ ALTERATION LEVEL 3- ALTERATIONS APPLY WHERE THE
WORK AREA EXCEEDS 50% OF THE AGGREGATE AREA
OF THE BUILDING.
BUILDING DESCRIPTION
1. NUMBER OF FLOORS IN BUILDING: ................................
1
2. CONSTRUCTIONTYPE:................................................
II-B
3. FLOOR(S) OF PROPOSED RENOVATION: .......................
1
4. CURRENT OCCUPANCY: .......................................
VACANT
5. PROPOSED OCCUPANCY :............................................
A-2
ADJACENT OCCUPANCY (NORTH):................................B
ADJACENT OCCUPANCY (SOUTH):.............................All
6. REQUIRED SEPARATION OF OCCUPANCY: .................
Tor
11:61CG:
].
EXTERIOR STOREFRONT RENOVATION?
❑
8.
PROPOSED STRUCTURAL ALTERATIONS?
❑
9.
ENERGY CALCULATION ATTACHED?
®
❑
10.
TOILET FACIUTIES PROVIDED?
®
❑
11.
EXISTING FIRE SPRINKLERS?
®
❑
12.
`FIRE ALARM SYSTEM MODIFICATIONS?
❑
13.
*FIRE SPRINKLER SYSTEM MODIFICATIONS?
❑
* G.C. TO PROVIDE FIRE SPRINKLER AND FIRE ALARM
SHOP DRAWINGS FOR MODIFICATIONS TO FIRE
SPRINKLER AND FIRE ALARM SYSTEM.
SCOTT LASKY ARCHITECT
3330 NE 34 STREET
FT. LAUDERDALE, FL 33308
WWW. LASKYARCHITECT.COM
954.566.5051
FIRE
TABLE (I IBC 2012
RATING
CONSTRUCTION TYPE
TYPE II
BUILDING ELEMENTS
B
STRUCTURALFRAME:
INCL: COLUMNS, GIRDERS, TRUSSES
0
BEARING WALLS:
EXTERIOR
0
INTERIOR
0
NONBEARING WALLS AND PARTITIONS:
EXTERIOR
0
NONBEARING WALLS AND PARTITIONS:
INTERIOR
0
FLOOR CONSTRUCTION:
INCL.: SUPPORTING BEAMS, JOISTS
0
ROOF CONSTRUCTION:
INCL.: SUPPORTING BEAMS, JOISTS
0`
c. IN ALL OCCUPANCIES, HEAVY TIMBER SHALL BE
ALLOWED WHERE A 1-HOUR OR LESS
FIRE -RESISTANCE RATING IS REQUIRED.
PLUMBING FUTURE REQUIREMENTS
TABLE 403.1, PC 2006
MIN. NUMBER OF PLUMBING FIXTURES
OCCUPANCY
A-2 RESTAURANT
55 OCCUPANTS - 28 MALES/28 FEMALES
CODE
REQUIRED
PROVIDED
WATER CLOSETS
1 PER 75 MALE
2
2
1 PER 75 FEMALE
LAVATORIES
1 PER 200 OCCUPANTS
1
2
WATER FOUNTAIN
1 PER 500 OCCUPANTS
0*
0*
SERVICE SINK
1
1
*SECTION 410.1
WHERE RESTAURANTS PROVIDE DRINKING WATER IN A
CONTAINER FREE OF CHARGE, DRINKING FOUNTAINS
SHALL NOT BE REQUIRED IN THOSE RESTAURANTS.
9873 NORTH MICHIGAN ROAD
CARMEL, IN 46032
WALL AND CEILING
FINISH REQUIREMENTS
BY OCCUPANCY
TABLE 803.9, IBC 2012
SPRINKLERED'
GROUP
INTERIOR EXIT
CORRIDORSAND
STAIRWAYS, INTERIOR
ENCLOSURE FOR
ROOMS
EXIT RAMPS AND EXIT
EXIT ACCESS
ENCLOSED SPACES
PASSAGEWAYS"
STAIRWAYS AND EXIT
ACCESS RAMPS
A-2
B
B
C
For 61: 1 Inch = 25Amm,1 aquwa loot = 0.0929 m
a. CLASS C INTERIOR FINISH MATERIALS SHALL BE PERMITTED FOR WAINSCOTTING OR
PANELING OF NOT MORE THAN 1,000 SQUARE FEET OF APPLIED SURFACE AREA IN THE
GRADE LOBBY WHERE APPLIED DIRECTLY TO A NONCOMBUSTIBLE BASE OR OVER
FURRING STRIPS APPLIED TO A NONCOMBUSTIBLE BASE AND FIREBLOCKED AS
REQUIRED BY SECTION 803.11.1.
b. IN OTHER THAN GROUP 1-2 OCCUPANCIES IN BUILDINGS LESS THAN THREE STORIES
ABOVE GRADE PLANE OF OTHER THAN GROUP 1-3, CLASS B INTERIOR FINISH FOR
NONSPRINKLERED BUILDINGS AND CLASS C INTERIOR FINISH FOR SPRINKLERED
BUILDINGS SHALL BE PERMITTED IN INTERIOR EXIT STAIRWAYS AND RAMPS.
c. REQUIREMENTS FOR ROOMS AND ENCLOSED SPACES SHALL BE BASED UPON SPACES
ENCLOSED BY PARTITIONS. WHERE A FIRE -RESISTANCE RATING IS REQUIRED FOR
STRUCTURAL ELEMENTS, THE ENCLOSING PARTITIONS SHALL EXTEND FROM THE FLOOR
TO THE CEILING. PARTITIONS THAT DO NOT COMPLY WITH THIS SHALL BE CONSIDERED
ENCLOSING SPACES AND THE ROOMS OR SPACES ON BOTH SIDES SHALL BE
CONSIDERED ONE. IN DETERMINING THE APPLICABLE REQUIREMENTS FOR ROOMS AND
ENCLOSED SPACES, THE SPECIFIC OCCUPANCY THEREOF SHALL BE THE GOVERNING
FACTOR REGARDLESS OF THE GROUP CLASSIFICATION OF THE BUILDING OR
STRUCTURE.
d. LOBBY AREAS IN GROUP A-1, A-2 AND A-3 OCCUPANCIES SHALL NOT BE LESS THAN
CLASS B MATERIALS.
e. CLASS C INTERIOR FINISH MATERIALS SHALL BE PERMITTED IN PLACES OF ASSEMBLY
WITH AN OCCUPANT LOAD OF 300 PERSONS OR LESS.
I. FOR PLACES OF RELIGIOUS WORSHIP, WOOD USED FOR ORNAMENTAL PURPOSES,
TRUSSES, PANELING OR CHANCEL FURNISHING SHALL BE PERMITTED.
g. CLASS B MATERIAL IS REQUIRED WHERE THE BUILDING EXCEEDS TWO STORIES.
h. CLASS C INTERIOR FINISH MATERIALS SHALL BE PERMITTED IN ADMINISTRATIVE SPACES.
I. CLASS C INTERIOR FINISH MATERIALS SHALL BE PERMITTED IN ROOMS WITH A CAPACITY
OF FOUR PERSONS OR LESS.
j. CLASS B MATERIALS SHALL BE PERMITTED AS WAINSCOTING EXTENDING NOT MORE
THAN 48 INCHES ABOVE THE FINISHED FLOOR IN CORRIDORS AND EXIT ACCESS
STAIRWAYS AND RAMPS.
R. FINISH MATERIALS AS PROVIDED FOR IN OTHER SECTIONS OF THIS CODE.
I. APPLIES WHEN PROTECTED BY AN AUTOMATIC SPRINKLER SYSTEM INSTALLED IN
ACCORDANCE WITH SECTION 903.3.1.1 OR 903.3.1.2.
p�
0
p�
y
v
Ua
TV
O
M
W
S
Z w
o
DID v
M �
So
a
V
69
m
y
w
F
ad
w
x
D
a
r
Y
In
a
J
F
a
D
Nrtf(i,>A AND THEPROTESTS
NOTT BE REEF IOF SI(4D
x UNCUT THE wITTEN CONSENT BE
Rf01ECT
l� �I
Fon
W
Con
VVV
zN
M
W
C7
SIC
w�z�
M
�rr
00
ll
REVISIONS DATES:
PROFESSIONAL
•;
\
i fA
•' 9
rn
r
�n
K07 L. LASKl # ARI14WIS
RESTTE
OFINDH A
STATEOFINUTANA
ISSUE DATE:
03.01.19
PROJECT #:
282C.1268C
1
DRAWN BY:
RJ
CHECKED BY:
SL/VO
COVER
SHEET
CS-1