Loading...
HomeMy WebLinkAboutCS-1 Cover SheetPROJECT PROJECT LOCATION LOCATION 1p61h 5Lee1 Ipfi ,' 4 Bill, 1 A' 0 ' 4 A�..M-�UAF t 431 1 i,-i µn1961h sued 4\ ^ryt VICINITY MAP LOCATION MAP N.T.S. N.T.S. SHEETINDEX LEGEND DENOTES CURRENT SHEET DENOTES SHEET WAS SUPERCEDED r w m C SHEET NO. SHEET TITLE CS-1 COVER SHEET CS-2 GENERAL NOTES & TYPICAL DETAILS CS-3 ACCESSIBILITY PLAN CS-4 UL LISTINGS CS-4.1 UL LISTINGS LS-1 LIFE SAFETY PLAN ARCHITECTURAL D-1 DEMOLITION PLAN D-2 DEMOLITION CEILING PLAN A-1 FLOOR PLAN A-1.1 EQUIPMENT PLAN A-2 REFLECTED CEILING PLAN A-3 FINISH PLAN A-4 MILLWORK & DETAILS PLUMBING P-1 PLUMBING PLANS,DETAILS, NOTES, LEGEND & SCHEDULE MECHANICAL M-1 MECHANICAL DETAILS. NOTES, LEGEND & SCHEDULE M-2 HVAC PLANS ELECTRICAL E-1 ELECTRICAL RISER, PANELS, NOTES, LEGEND & SCHEDULE E-2 POWER AND ROOF POWER PLAN RELEASED FOR CONSTRUCTION "'A .. Subjecttoance d Local all regulaiipns Lof State and Local Codes City d Camel V wb U0+ DATE: 09/06/19 SCOPE OF WORK TENANT IMPROVEMENT CONSISTING OF THE CONSTRUCTION OF A NEW HAMBURGER RESTAURANT WITHIN AN EXISTING BUILDING SHELL, TO INCLUDE ALL ELECTRICAL, PLUMBING AND MECHANICAL MODIFICATIONS, NTERIOR PARTITIONS AND EQUIPMENT NO STRUCTURAL OR STOREFRONT MODIFICATIONS ARE PART OF THE SCOPE. THIS TENANT IS FULLY EQUIPPED WITH FIRE SPRINKLER. PROJECT DIRECTORY TENANT CHEEEBURGER ZIONSVILLE, LLC 712 SETTLERS WALK DR. BROWNSBURG, IN 46112 CONTACT: HIEN B. LY(HELEN) PH: 317-459-1636 CELL: 317-459-1636 EMAIL: HIENBLY@ICLOUD.COM LANDLORD OWNER: CRI WEST CARMEL, LLC(INDIANA CO.) COMPANY: CASTO 250 CIVIC CENTER DR., STE 500 COLUMBUS, OH 43215 CONTACT: KELLY FENIMORE PH: 614-227-3466 FAX: 614-221-3076 EMAIL: KFENIMORE@CASTOINFO.COM GOVERNING AGENCIES CITY OF CARMEL HAMILTON COUNTY HEALTH DEPARTMENT BUILDING & CODE SERVICES 18030 FOUNDATION DRIVE SUITE ONECIVICSQUARE NOBLESVILLE, IN 46060 CARMEL, IN 46032 PHONE: 31 T-TT6-8500 317-571-2444 FAX: 317-776-8506 CODE INFORMATION J 2012 INTERNATIONAL BUILDING CODE W/2014 INDIANA AMENDMENTS ® 2012 INTERNATIONAL FIRE CODE W/2014 INDIANA AMENDMENTS ® 2010 INTERNATIONAL ENERGY CONSERVATION CODE ® 2012 INTERNATIONAL FUEL GAS CODE ® 2006 INDIANA PLUMBING CODE W/ 2014 INDIANA AMENDMENTS ® 2012 INTERNATIONAL MECHANICAL CODE W/2014 INDIANA AMENDMENTS ® 2008 NATIONAL ELECTRIC CODE W/ 2014 INDIANA AMENDMENTS ® 2012 ADA STANDARD CLASSIFICATION OF WORK (IEBC, 2012 CHAPTER 5) ❑ ALTERATION LEVEL 1 -ALTERATIONS INCLUDE THE REMOVAL AND REPLACEMENT OR THE COVERING OF EXISTING MATERIALS, ELEMENTS, EQUIPMENT, OR FIXTURES USING NEW MATERIALS, ELEMENTS, EQUIPMENT, OR FIXTURES THAT SAVE THE SAME PURPOSE. ® ALTERATIONLEVEL2- ALTERATIONS INCLUDE THE RECONFIGURATION OF SPACE, THE ADDITION OR ELIMINATION OF ANY DOOR OR WINDOW, THE RECONFIGURATION OR EXTENSION OF ANY SYSTEM, OR THE INSTALLATION OF ANY ADDITIONAL EQUIPMENT. ❑ ALTERATION LEVEL 3- ALTERATIONS APPLY WHERE THE WORK AREA EXCEEDS 50% OF THE AGGREGATE AREA OF THE BUILDING. BUILDING DESCRIPTION 1. NUMBER OF FLOORS IN BUILDING: ................................ 1 2. CONSTRUCTIONTYPE:................................................ II-B 3. FLOOR(S) OF PROPOSED RENOVATION: ....................... 1 4. CURRENT OCCUPANCY: ....................................... VACANT 5. PROPOSED OCCUPANCY :............................................ A-2 ADJACENT OCCUPANCY (NORTH):................................B ADJACENT OCCUPANCY (SOUTH):.............................All 6. REQUIRED SEPARATION OF OCCUPANCY: ................. Tor 11:61CG: ]. EXTERIOR STOREFRONT RENOVATION? ❑ 8. PROPOSED STRUCTURAL ALTERATIONS? ❑ 9. ENERGY CALCULATION ATTACHED? ® ❑ 10. TOILET FACIUTIES PROVIDED? ® ❑ 11. EXISTING FIRE SPRINKLERS? ® ❑ 12. `FIRE ALARM SYSTEM MODIFICATIONS? ❑ 13. *FIRE SPRINKLER SYSTEM MODIFICATIONS? ❑ * G.C. TO PROVIDE FIRE SPRINKLER AND FIRE ALARM SHOP DRAWINGS FOR MODIFICATIONS TO FIRE SPRINKLER AND FIRE ALARM SYSTEM. SCOTT LASKY ARCHITECT 3330 NE 34 STREET FT. LAUDERDALE, FL 33308 WWW. LASKYARCHITECT.COM 954.566.5051 FIRE TABLE (I IBC 2012 RATING CONSTRUCTION TYPE TYPE II BUILDING ELEMENTS B STRUCTURALFRAME: INCL: COLUMNS, GIRDERS, TRUSSES 0 BEARING WALLS: EXTERIOR 0 INTERIOR 0 NONBEARING WALLS AND PARTITIONS: EXTERIOR 0 NONBEARING WALLS AND PARTITIONS: INTERIOR 0 FLOOR CONSTRUCTION: INCL.: SUPPORTING BEAMS, JOISTS 0 ROOF CONSTRUCTION: INCL.: SUPPORTING BEAMS, JOISTS 0` c. IN ALL OCCUPANCIES, HEAVY TIMBER SHALL BE ALLOWED WHERE A 1-HOUR OR LESS FIRE -RESISTANCE RATING IS REQUIRED. PLUMBING FUTURE REQUIREMENTS TABLE 403.1, PC 2006 MIN. NUMBER OF PLUMBING FIXTURES OCCUPANCY A-2 RESTAURANT 55 OCCUPANTS - 28 MALES/28 FEMALES CODE REQUIRED PROVIDED WATER CLOSETS 1 PER 75 MALE 2 2 1 PER 75 FEMALE LAVATORIES 1 PER 200 OCCUPANTS 1 2 WATER FOUNTAIN 1 PER 500 OCCUPANTS 0* 0* SERVICE SINK 1 1 *SECTION 410.1 WHERE RESTAURANTS PROVIDE DRINKING WATER IN A CONTAINER FREE OF CHARGE, DRINKING FOUNTAINS SHALL NOT BE REQUIRED IN THOSE RESTAURANTS. 9873 NORTH MICHIGAN ROAD CARMEL, IN 46032 WALL AND CEILING FINISH REQUIREMENTS BY OCCUPANCY TABLE 803.9, IBC 2012 SPRINKLERED' GROUP INTERIOR EXIT CORRIDORSAND STAIRWAYS, INTERIOR ENCLOSURE FOR ROOMS EXIT RAMPS AND EXIT EXIT ACCESS ENCLOSED SPACES PASSAGEWAYS" STAIRWAYS AND EXIT ACCESS RAMPS A-2 B B C For 61: 1 Inch = 25Amm,1 aquwa loot = 0.0929 m a. CLASS C INTERIOR FINISH MATERIALS SHALL BE PERMITTED FOR WAINSCOTTING OR PANELING OF NOT MORE THAN 1,000 SQUARE FEET OF APPLIED SURFACE AREA IN THE GRADE LOBBY WHERE APPLIED DIRECTLY TO A NONCOMBUSTIBLE BASE OR OVER FURRING STRIPS APPLIED TO A NONCOMBUSTIBLE BASE AND FIREBLOCKED AS REQUIRED BY SECTION 803.11.1. b. IN OTHER THAN GROUP 1-2 OCCUPANCIES IN BUILDINGS LESS THAN THREE STORIES ABOVE GRADE PLANE OF OTHER THAN GROUP 1-3, CLASS B INTERIOR FINISH FOR NONSPRINKLERED BUILDINGS AND CLASS C INTERIOR FINISH FOR SPRINKLERED BUILDINGS SHALL BE PERMITTED IN INTERIOR EXIT STAIRWAYS AND RAMPS. c. REQUIREMENTS FOR ROOMS AND ENCLOSED SPACES SHALL BE BASED UPON SPACES ENCLOSED BY PARTITIONS. WHERE A FIRE -RESISTANCE RATING IS REQUIRED FOR STRUCTURAL ELEMENTS, THE ENCLOSING PARTITIONS SHALL EXTEND FROM THE FLOOR TO THE CEILING. PARTITIONS THAT DO NOT COMPLY WITH THIS SHALL BE CONSIDERED ENCLOSING SPACES AND THE ROOMS OR SPACES ON BOTH SIDES SHALL BE CONSIDERED ONE. IN DETERMINING THE APPLICABLE REQUIREMENTS FOR ROOMS AND ENCLOSED SPACES, THE SPECIFIC OCCUPANCY THEREOF SHALL BE THE GOVERNING FACTOR REGARDLESS OF THE GROUP CLASSIFICATION OF THE BUILDING OR STRUCTURE. d. LOBBY AREAS IN GROUP A-1, A-2 AND A-3 OCCUPANCIES SHALL NOT BE LESS THAN CLASS B MATERIALS. e. CLASS C INTERIOR FINISH MATERIALS SHALL BE PERMITTED IN PLACES OF ASSEMBLY WITH AN OCCUPANT LOAD OF 300 PERSONS OR LESS. I. FOR PLACES OF RELIGIOUS WORSHIP, WOOD USED FOR ORNAMENTAL PURPOSES, TRUSSES, PANELING OR CHANCEL FURNISHING SHALL BE PERMITTED. g. CLASS B MATERIAL IS REQUIRED WHERE THE BUILDING EXCEEDS TWO STORIES. h. CLASS C INTERIOR FINISH MATERIALS SHALL BE PERMITTED IN ADMINISTRATIVE SPACES. I. CLASS C INTERIOR FINISH MATERIALS SHALL BE PERMITTED IN ROOMS WITH A CAPACITY OF FOUR PERSONS OR LESS. j. CLASS B MATERIALS SHALL BE PERMITTED AS WAINSCOTING EXTENDING NOT MORE THAN 48 INCHES ABOVE THE FINISHED FLOOR IN CORRIDORS AND EXIT ACCESS STAIRWAYS AND RAMPS. R. FINISH MATERIALS AS PROVIDED FOR IN OTHER SECTIONS OF THIS CODE. I. APPLIES WHEN PROTECTED BY AN AUTOMATIC SPRINKLER SYSTEM INSTALLED IN ACCORDANCE WITH SECTION 903.3.1.1 OR 903.3.1.2. p� 0 p� y v Ua TV O M W S Z w o DID v M � So a V 69 m y w F ad w x D a r Y In a J F a D Nrtf(i,>A AND THEPROTESTS NOTT BE REEF IOF SI(4D x UNCUT THE wITTEN CONSENT BE Rf01ECT l� �I Fon W Con VVV zN M W C7 SIC w�z� M �rr 00 ll REVISIONS DATES: PROFESSIONAL •; \ i fA •' 9 rn r �n K07 L. LASKl # ARI14WIS RESTTE OFINDH A STATEOFINUTANA ISSUE DATE: 03.01.19 PROJECT #: 282C.1268C 1 DRAWN BY: RJ CHECKED BY: SL/VO COVER SHEET CS-1