HomeMy WebLinkAboutD-1 Demolition PlanDEMOLITION KEYNOTES xO
1 (E) INTERIOR PARTITION WALL TO BE REMOVED. G.C. TO PATCH AND REPAIR ADJACENT WALL AFFECTED BY
DEMOLITION.
) 2 I E INTERIOR DOOR, FRAME & HARDWARE TO BE REMOVED.
3 IE) INTERIOR PARTITION WALL TO REMAIN.
4 (E) SERVICE COUNTER TO BE REMOVED.
5 (E) EXTERIOR WALL TO REMAIN.
6 (E) TENANT SEPARATION WALL TO REMAIN. GC TO PROTECT WALL DURING CONSTRUCTION AND MAINTAIN
FIRE RATING THROUGHOUT CONSTRUCTION PROCESS.
7 (E)SINK TO BE REMOVED,D.C. TO CAP AND SEAL ANY PLUMBING LINE NOT BEING USED
B (E) EGRESS DOOR AND PANIC HARDWARE TO REMAIN
9 (E) EXTERIOR STOREFRONT DOOR AND STOREFRONT SYSTEM TO REMAIN.
10 (E) ELECTRICAL PANELS TO REMAIN.
11 (E) MOP SINK TO REMAIN.
12 LEI WATER HEATER TO REMAIN.
13 (E) FLOORING MATERIAL TO REMAIN.
14 (E) ACOUSTICAL CEILING TO BE REMOVED. SEE 1/1)2.
15 (E) RESTROOM FIXTURES, WALLS, FINISHES, ACCESSORIES & CEILING TO REMAIN U.N.O.
16 (E) CEILING GRID, CEILING TILES & LIGHTING FIXTURES TO REMAIN. SEE 1/D-2.
17 IE) 3 COMPARTMENT SINK TO REMAIN
18 (E) PREP. SINK TO REMAIN
19 (E) HAND SINK TO REMAIN
20 (E) FLOORING TO REMAIN
21 (E) CEILING CLOUDS, LIGHTNING FIXTURE AND SOFFITS TO REMAIN. SEE 1/D-L. REFER TO ELECTRICAL
PLANS FOR DETAILS.
22 (E) MECHANICAL SYSTEM(DUCTWORK, RETURN ANDEXHAUST) TO REMAIN. REFER TO MECHANICAL PLANS
FOR DETAILS.
22 (E) MECHANICAL SYSTEM (DUCTWORK, RETURN AND EXHAUST) TO REMAIN. REFER TO MECHANICAL PLANS
FOR DETAILS.
23 (E) PORTION OF INTERIOR WALL TO BE REMOVED AS NOTED.
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and meal Codes
City
GF Canted
�VT�t�D*141WML
DATE: 09/06/19
DEMOLITION NOTES
1. THIS PORTION OF THE WORK TO INCLUDE ALL LABOR, MATERIALS AND SERVICES NECESSARY FOR ALL DISMANTLING, DEMOLITION AND SALVAGE
AS SHOWN ON THE DRAWING AND SPECIFIED HEREIN.
2, DEMOLITION WORK SHALL BE CONDUCTED IN ACCORDANCE WITH THE APPLICABLE SAFETY REQUIREMENTS OF THE LANDLORD, CITY AND STATE
OF THE PROJECT THE ASSOCIATED GENERAL CONTRACTOR'S MANUAL OF ACCIDENT PREVENTION ON CONSTRUCTION LATEST EDITION AND
THE APPLICABLE REQUIREMENTS OF THE LOCAL BUILDING CODE.
3. ALL REWIRED BUILDING AND OTHER PERMITS IN CONNECTION WITH THE CONSTRUCTION AND COMPLETION OF THE TENANTS WORK IS THE
SOLE RESPONSIBILITY OF THE TENANT / TENANT'S CONTRACTORS).
4, CONTRACTOR TO VISIT THE SITE TO DETERMINE DEMOLITION REQUIREMENTS FAILURE OF CONTRACTOR TO ACQUAINT HIMSELF WITH ALL
AVAILABLE INFORMATION CONCERNING CONDITIONS WILL NOT RELIEVE HIM FROM THE RESPONSIBILITY FOR ACCURATELY ESTIMATING THE
DIFFICULTY OR THE COST OF THE WORK
5, GC MUST VERIFY CONDITIONS FOR ALL DEMISING WALLS. PATCH AND REPAIR AS NECESSARY. FIRE SEPARATION BETWEEN TENANTS MUST
COMPLY WITH ALL LOCAL CODES. ALL DEMISING WALL WORK TO BE DONE PRIOR TO INTERIOR CONSTRUCTION DEMISING WALLS SHALL BE
1-HOUR RATED, PATCHED AND FIRE STOPPED AS REWIRED. NONMETALLIC PIPES PENETRATING DEMISING WALLS SHALL USE ATTACHED FIRE
COLLAR.
6, THE EXISTING CONCRETE SLAB SHALL BE WELL PREPARED TO RECEIVE NEW FLOORINGS.
]. ALL MATERIALS USED IN THE CONSTRUCTION OF THE SPACE MUST BE ASBESTOS FREE.
6 NOTIFY ARCHITECT IMMEDIATELY OF ANY INCONSISTENCIES OR DISCREPANCIES WITH PLANS IN RELATION TO EXIST NO FIELD CONDITIONS.
9, IT IS THE TENANT / TENANTS CONTRACTOR RESPONSIBILITY TO FIELD VERIFY ALL EXISTI NO CONDITIONS AND DIMENSIONS.
10, IF ANY EXISTING FIRE PROOFING OR FIRE ASSEMBLIES TO REMAIN ARE DAMAGED DURING DEMOLITION, THEY SHALL BE REPAIRED TO CONFORM
TO THE ORIGINAL FIRE PROTECTION REQUIREMENTS. CONTACT ARCHITECT TO VERIFY UL ASSEMBLIES TO BE USED FOR REPAIRS
11, REFER TO MECHANICAL, PLUMBING, FIRE PROTECTION, COMMUNICATIONS INFORMATION SYSTEMS AND ELECTRICAL DRAWINGS FOR EXTENT
AND LOCATION OF CHANNELING OF EXISTING FLOOR SLAB. IF EXISTING PIPING OR CONDUIT WORK (OTHER THAN THE DESIRED CONNECTION) IS
ENCOUNTERED WHILE CHANNELING, THE CONTRACTOR SHALL NOTIFY THE ARCHITECT BEFORE CONTINUING
12, THE CONTRACTOR SHALL VERIFY THAT CONSTRUCTION OF EXISTING WALLS MEETS THE FIRE PROTECTION RATING DESIGNATED ON THESE
DRAWINGS HE SHALL ALSO MAKE ANY REPAIRS OR MODIFICATIONS NECESSARY TO BRING EXISTING WALLS, FLOORS, DUCTS, ETC UP TO THE
PROPER INDICATED FIRE PROTECTION RATING. DOORS AND FRAMES NOT MEETING RATING REQUIREMENTS OR BEARING PROPER LABELS SHALL
BE REPLACED.
w�
0
N
N
v
Ua
TV
o
M
W
S
Z w
O
Qj
�
N
m
y
W
f
U
W
F
U
a
}
Y
in
a
J
I—
I—
D
N
. xnrzT PA ENO sx�.ueo REPRCD'LJ(:c)
WMOUT WEwwrhN CONSENT OF
ROE
IIIIIIIIIIIIIIIN
�
r TOTW
v
z
N
M
W
C7
Zo
w�z�
M
Q
00
REVISIONS DATES:
PROFESSIONAL
IM
m
Mybdm � r
�n
K07L. LASKY# AKIN 1W
REGISTEREDAVTUTCT
STATEGFINDIANA
ISSUE DATE:
03.01.19
PROJECT#:
28C.126RCI
DRAWN BY:
HJ
CHECKED BY:
SL/VO
DEMOLITION
PLAN
D-1