HomeMy WebLinkAboutP2 Grease Trap InfoSCOPE OF WORK
PROVIDE ALL PLUMBING FOR NEW RESTAURANT INCLUDING ALL WATER, GAS,
GREASE & SANITARY LINES AND CONNECT TO EXISTING UTILITIES. USE EXISTING
WATER HEATER.
COORDINATE WITH GC AND MECHANICAL CONTRACTOR FOR ANY REQUIRED
CONDENSATE LINES.
PLUMBING NOTES
1. ALL WORKMANSHIP AND MATERIALS SHALL BE IN STRICT ACCORDANCE WITH
APPLICABLE LOCALCODES, RULESAND ORDINANCES.
2. PLUMBING CONTRACTOR SHALL REVIEWALL DRAWINGS OF THIS SET.
CONTRACTOR TO VERIFYTHATALL EQUIPMENT SHOWN AS EXISTING MATCHES
THE DESCRIPTIONS AND SPECIFICATIONS SHOWN ON DRAWINGSAND
SCHEDULES. IF DIFFERENT NOTIFY ARCHITECT/ENGINEER BEFORE BIDDING,
ORDERING OR PRECEDING WITH WORK.
3. ALL EQUIPMENT WHICH IS TO REMAIN MUST BE REFURBISHEDTO A LIKE NEW
CONDITION.
4. PLUMBING CONTRACTOR SHALLVISITTHE JOB SITE ANDTHOROUGHLY
FAMIUARIZE HIMSELF WITH ALL EXISTING CONDITIONS.
S. ALL MATERIALS SHALL BE NEW.
6. ALL WORK SHALL BE PERFORMED BY A LICENSED PLUMBING CONTRACTOR IN
FIRST CLASS WORKMANLIKE MANNER. THE COMPLETED SYSTEM SHALL BE FULLY
OPERATIVE. ALL EXCAVATION AN D BACKFI ILL AS REQUIRED FOR THIS PHASE OF
CONSTRUCTION SHALL BE A PART OF THIS CONTRACT.
7. REQU I RE D I N SU RAN CIE SHALL BE PROVI DIED BY TH E PILL M BI NG CO NTRACTOR FOR
PROTECTION AGAINST PUBLIC LIABILITY AND PROPERTY DAMAGE FOR THE
DURATION OF THE WORK.
8. PLUMBING CONTRACTOR SHALL SECURE AND PAY FOR ALL PERMITS FEES
INSPECTION AND TESTS. PLUMBING CONTRACTOR TO OBTAIN PERMIT AND
APPROVED SUBMITTALS PRIOR TO BEGINNING WORK OR ORDERING EQUIPMENT.
PLUMBING CONTRACTOR MUST BE PRESENT FOR ALL INSPECTIONS OF HIS WORK
BY REGULATORY AUTHORITIES.
9. DRAWINGS ARE DIAGRAMMATIC. DO NOT SCALE FOR THE EXACT LOCATION OF
FIXTURES, PIPING, EQUIPMENT, ETC.
10. ALL WORK SHALL BE COORDINATED WITH OTHER TRADES TO AVOID
INTERFERENCE WITH THE PROGRESS OF CONSTRUCTION. REPORT ANY
DISCREPANCY TO ENGINEER/ARCHITECT PRIOR TO BEGINNING CONSTRUCTION.
11. VERIFY LOCATION, SIZE, DIRECTION OF FLOW AND INVERTS OF ALL EXISTING
UTILITIES PRIOR TO BEGINNING OF CONSTRUCTION. ADVISE ENGINEER OF ANY
DISCREPANCIES.
12. EXPOSED WATER PIPING SHALL BE TYPE "L" COPPER THAT MEEFS ASTM B88
FOR 2" AND UNDER. WATER PIPING IN WALLS AND UNDERGROUND SHALL BE
CPVC OR "PEX" TYPE PIPING THAT MEETS ANSI/NSF STANDARD 61.
13. SOIL, WASTE, VENT AND RAINWATER PIPING SHALL BE PVC SCHEDULE 40 THAT
M EEFS ASTM D 2665/ASTM F 891/ASTM F 1488 BUT MAY NOT RUN THRU RATED
ASSEMBLIES OR IN PLENUMS.
14. ALL FIXTURES MUST BE PROVIDED WITH READILY ACCESSIBLE STOPSAND
APPROPRIATELY MARKED ACCESS PANELS. COORDINATE LOCATIONS WITH
GENERAL CONTRACTOR PRIOR TO INSTALLATION.
15. FURNISH AND INSTALL APPROVED AIR CHAMBERS AT EACH PLUM BING FIXTU RE
GROB P AS PER CODE AND WITH GOOD ENGINEERING PRACTICE.
16. DIELECTRIC COUPLINGS ARE REQUIRED BETWEEN ALL DISSIMILAR METAL IN
PIPING AN D EQUIPMENT CONNECTIONS; EXCEPT AT WATER HEATER AS PER CODE.
17. ISOLATE COPPER PIPE FROM HANGER OR SUPPORTS WITH ISOLATOR PAD.
18. ALL FIRE RATED FLOOR AND WALL PEN ETRATIONS SHALL BE PROPERLY
PROTECTED FROM FIRE, SMOKE AND WATER PENETRATION BY FILLING VOIDS
BETWEEN PIPE AND WALL/FLOOR SLEEVES WITH FIRE RATED FOAM, TO ACHIEVE
THE SAME RATING AS WALLS OR FLOORS AS PART OF THE PLUM BER'S WORK.
19. PLUMBING CONTRACTOR SHALL GUARANTEE ALL MATERIALS AN D
WORKMANSHIP FREE FROM DEFECTS FOR A PERIOD OF NOT LESS THAN ON E (1)
20. STUDDS MINI/MAXI AIR ADMITTANCE VALVES MAY NOT BE USED AS AN
ALTERNATE TO VENT PIPING THRU ROOF.
21. PROVIDE CHROME PLATED COMBINATION COVER PLATE AND CLEAN OUT PLUG
OR ACCESS PAN EL FOR ALL CLEANOUTS.
22. NO COMBUSTIBLE MATERIAL TO BE USED IN MECHANICAL ROOMS OR IN CEILING
SPACES WHERE USED AS RETURN AIR PLENUMS.
23. NO WATER, SANITARY OR DRAINAGE PIPING PERMITTED IN ELECTRICAL OR
25. CON DENSATE DRAIN LINES TO BE RUN UNDER SLAB IN PVC SCH40 PIPE AN D
26. PROVIDE ANGLE STOPS ON ALL WATER SERVICE LIN ES TO FIXTURES FOR
INDIVIDUAL SHUT-OFF.
27. NO JOINTS UNDERGROUND FOR COPPER.
28. PLUMBING FIXTURES SHALL COMPLY WITH IBC -PLUMB.
29. WATER HAM MER ARRESTORS AS PER IBC -PLUMB.
30. PLUMBING CONTRACTOR TO PROVIDE ANTI -SCALDING VALVE FOR TUBS AND
SHOWERS.
31. PLUMBING CONTRACTOR SHALL REVIEW ALL BID DOCUMENTATION.
32. PLUMBING CONTRACTOR SHALL REVIEW WALL FINISHES Lal LOCATION REQUIRING
BARRIER -FREE COMPLIANCE (EXAMPLE: CENTER LINE TO TOILET).
33. CONSTRUCTION "AS BUILT" DRAWINGS AND DOCUMENTS SHALL BE PROVIDED TO
THE OWNER WITHIN 30 DAYS AFTER THE DATE OF ACCEPTANCE.
34. OPERATION MANUALS AND MAINTENANCE MANUALS SHALL BE PROVIDED TO
THE BUILDING OWNER.
FIXTURE BRANCH SCHEDULES
F
FIXTURE
4' WATER CLOSET(TANK)
T LAVATORY
COLD
WATER
HOT
WATER
WASTE
VENT
112-
3'
T
1r2'
1r2'
1112'-T
3'SERVICE SINK
FLOOR DRAIN/SINK
12'
12'
11ITT
-
-
T-4'
11/T-2"
PLUMBING LEGEND
SANITARY SEWER PIPING
VENT PIPING
DOMESTIC COLD WATER PIPING
HOT WATER PIPING B1ED)
HOT WATER PIPING N40°)
CONDENSATE PIPING
COMPRESSED AIR PIPING
TEMPERATURE & PRESSURE RELIEF
STORM DRAIN PIPING
GAS PIPING
PIPE RISE OR DROP
PIPE RISER UP
rr
- - -
--�
- - �
- - �
cD _ cD
�" -GA - - -
Pv - NN
r w _ w
T
GAS - Gu ---
C
CAPPED END OF PIPE
(r-CO
CLEAN OUT
0DF0
P-TRAP
S,Q,V,
SHUT-OFF VALVE
COLIC
CLEAN OUT TO GRADE
CW
DOMESTIC COLDWATER
'T{W
DOMESTIC HOT WATER
HWR
DOMESTIC HOT WATER RETURN
o-j-HB
HOSE BIBB
VTR
VENT THRU ROOF
DQ
GATE VALVE
GLOBE VALVE
N
CHECKVALVE
BALANCING VALVE
GAS COCK
WATER HAMMER ARRESTER
® FD
FLOOR DRAIN
F.W.
FILTERED WATER
BACKFLOW PREVENTOR
I. W.
INDIRECT WASTE
FLOOR SINK
AIR ADMITTANCE VALVE
HDOr(I
HUB DRAIN
IJI,IITT��
THERMOSTATIC MIXING VALVE
RESTROOM FIXTURE SCHEDULE
WATER
WASTE
Item No.
Oly.
Descnpton
Manufacturer
Model
Hot
Cod
Waste
Usage
Spec
A
2
LAVATORY
EXISTING
EXISTING TO REMAIN
1
2
LAVATORYFAUCET
IXISTING
EXISTING TO REMAIN
2
THERMALMIXINGVALVES
EXISTING
EXISTING TO REMAIN
2
INSULATED PLUMBING COVERS
IXISTING
EXISTING TO REMAIN
C
2
WATER CLOSET
EXISTING
EXISTING TO REMAIN
2
ELONGATED SEAT
IXISTING
EXISTING TO REMAIN
KITCHEN EQUIPMENT PLUMBING SCHEDULE
WATER
WASTE
ITEM NO.
Ow.
DESCRIPTION
MANUFACTURER
MODEL
HOT
COW
Direct
Indirect
F3
1
ICE MAKER
MMIFTOWOC
499UYFo140AA
1/2"
34"
FT
1
COLD PANS
ADVANCE TABOO
DIRI
3/4"
FB
4
SOFT SERVE MACHINES
TAYLOR CROWN
C723
RE
18
1
SODA MACHINE
BYOTHERS
BYOTHERS
1/2"
1"
27
1
HAND SINK
EXISTING
EXISTINGTOREMAIN
39
1
BAG-N-BOX
BY OTHERS
1/2"
42
1
MOPSINK
EXISTING
EXISTING TO REMAIN
42A
1
MOP SINK FAUCET
EXISTING
EXISTINGTOREMAIN
45B
1
PREP SINK
EXISTING
EXISTING TO REMAIN
1
PREP SINK FAUCET
EXISTING
EXISTING TO REMAIN
45C
1 1
SINK,3COMPARTMENT
EXISTING
EXISTING TO REMAIN
49
1
FAUCET
EXISTING
EXISTING TO REMAIN
51
1
SODADISPENSER
MO UNITED ICE MAKER
HOSHIZAM
KMD410MM
1l2"
1l2"
57
1 1
1WATER HEATER
SEE SCHEDULE
SEE SCHEDULE
EHS-1HL ll2" ll2" 1112"
RELMEDFORCONSTRUCTION Z190 311ZS19o0IFINEXPOSEDAREAS)
Subject to compliance with all regulations ZS415 W/ TYPE BS STRAINER
of State and meal Codes •• CHILLED WATER
City of Camel
DATE: 09/06/19
` V
MANUFACTURER
LOCHINNR
MODEL
LTA04ow
NEW
EXISTING
CAPACITY
40 GALLONS
FUEL
ELECTRIC
KW
4.5
RECOVERY
21 GPHA
VOLTAGE
"ll/So
AMPERAGE
19
WRIGHT FMPTY)
EXISTING
. 0 90- F TEMPERATURE
RISE
o
Cl
roNENNE sox.NTEl
U PM ENT EE
Fell RED
wv mmE DCOR
,w,ox zi wo��EaXV i�/T x�]ny�� orou:x nrE
F=R FARM
xexr
REFEREED
RMING
MAM
ewvrcx®x
IIm AP cwPross:w
FLOOR DRAIN
RITINE
TRAP RESEAL DETAIL
FLOOR CLEANOUT
FLOOR GRATE TO BE DRNNUNE
FASTENED DOWN WITH
SCREENS
MOUNT FLUSH WITH
FINISHED FLOOR
AIRG4P=2%FOR (2MIN.) a xwF
r. c
a -
`
p �
4 Ao ✓
Q W d
HUB OURET
FLUSH TO FLOOR SINK DETAIL
NOT TO SCALE
GAS SHUT-OFF 4� o ,
INTERCONNECTED TO HOOD
SUPPRESSION SYSTEM
J
-' CONNECT TO IXISTING 39
j- WATER LINE (V.I.F)
INK AND WATER HEATER t BACK KITCHEN U
KISTING TO REMAIN PREP SINK IS,,0
COMPSINKIS EXISTING TO REMAIN -
WIN GREAM INTERCEPTER
SANITARY RISER SCALE 3 I
N.T.S
Ji
CONNECT NEW
YOGURT MACHINE TO
EXISTING UTILITIES O
FOREVER YOGURT MACHINES 1YOGURT O
EQUIPMENT? �x r �1 F O
UP TO "'- - - - - ❑ I I BULK CANDY
KISTING TO REMIAN O
49 (E) 49 27 MUA
5 (E1 6 (E) iONNECT NEW GAS
LINE TO EXISTING GAS
LINE VALF I I\ FY POS
CO NNECTTO \��x
M min SINK IS PREVO
EXISTING TO REMAIN FIXTURE (V. F)
FRONT SERVICEUS
/
(E) WOMEN
ACCESSIBLE
(] MEN
ACCESSIBLE
/RESTROOM
(EI 1 lr1
HALLWAY
RESTROOM
(E)
AREA
THERMAL
MIXING VALVE
REQUIRED
I
_ II CONNECT TO
WATER L
\-EXISTING LINES FROM
CHILLER RECONNECT TO
SELF SERVE STATION NEW YOGURT MACHINES
QUEUE LINE
WAITING AREA
SCALE
WATER PLAN 1/4" = r-O^ 2
all
00
e zTeR
CERC
8�
C NNp CE
FEE$ "T E m
a Mom IRO
..
-m$Ell: Ec
mul is
i�< RE S;
OF
OF
ME
so
N
o
0
a
cp
z
w
Iljju•'I•II w
f� Z
CIE
w
PROTECT
W
Ell
O
VH
M
-EIFFy�
REVISIONS DATES:
1 0123/19PROJECTCOORDINATION
PROFESfeSEAL
\\�\�1ENGE�ll4���
4U �:
1 NO.PE102oa w
WEF
% yf` allATEOF i= E
FE
SSI\\\ I'
HUCENGELLPEMI@gM%
REUSTEREDENGINEER
STATEOFINDIANA
ISSUE DATE: 03.01.19
PROJECT#: 282C.1268C1
DRAWN BY: LD
CHECKED BY: AK
PLUMBING PLANS,
DETAILS NOTES,
LEGEND &
SCHEDULE
P-1