HomeMy WebLinkAboutSmock Fansler/Eng/CO #4/5,614/Gray Road Landscaping Improvements – Project #16-ENG-16, 54 & 55 CITY OF CARMEL TO: Jeremy Kashman CONTRACT CHANGE ORDER NO: 4 City Engineer DATE: 8-20-19 City of Carmel PROJECT NAME:Gray Rd 16-ENG-16,54,55 One Civic Square CITY REQ. NO: Carmel,IN 46032 CITY PO NO: CITY PO DATE: I. You are directed to make the following changes in this Contract: Added receptacles in P1 cabinets and inside roundabout for service and maintenance for the Street Department. Additional bore required for some locations. 0 cll. ITEM AMOUNT SCHEDULED ADJUSTMENT j+)OR(-)DAYS II. The following referenced documents further describe the changes outlined in paragraph I, and are to be considered a part of this Change Order R.F.P.: W.D.C. NO: Other:See contract change request No.004 The changes result in the following adjustment of Contract Price and Contract Time: Contract price prior to this change order $864,630.50 Contract price will be increased/decreased by this Change Order $5,614.00 New Contract Price including this Change Order $870,244.50 Contract Time prior to this Change Order Days Completion Date Net increased/decreased resulting from this Change Order Days Current Contract Time including this Change Order Completion Date This Change Order is for full and final settlement of all direct,indirect, impact costs and Time extensions incurred at any time resulting from the performance of the changed work. The Above Changes Are The Above Changes Are Approved Recommended Accepted Jason Evers Smock Fansler Ad+ ENGINEER CONTRACTOR James Brainard, Mayor One Civic Square 2910 W.Minnesota St. ADDRESS ADDRESS er a re City-Ef eer Carmel IN 46032 Indpls, IN 46241 _. City/S a e/Zip City/State/Zip /c Mary A rke,Me ber By: By: son Eyers /' L Joe Davee V.P. Lori Wat ember Phone: 311, W//04Ptione: 317-248-8371 A T G�iG(�l�u�� GGcc.&f Date: 1211/I q Date: 8/21/2 019 stifle Pauley, Cj rk-Treasurer CITY OF CARMEL TO: City of Carmel CONTRACT CHANGE REQUEST NO.: 004 Engineering Department DATE: June 25, 2019 One Civic square PROJECT NAME: 16-ENG-16,54,55 Gray Road Roundabouts Carmel, IN 46032 FROM: IT IS REQUESTED THAT A CONTRACT CHANGE BE MADE TO THE ABOVE REFERENCED CONTRACT. I. SCOPE OF WORK (USE ADDITIONAL PAGES IF REQUIRED. ALSO LIST OTHER CONTRACTS INVOLVED.) Added receptacles in P1 cabinets and inside roundabouts for service and maintenance. Additional Bore Required for some locations. 2. REASON FOR CHANGE: Carmel Street Department made the request after reviewing the project on site with electrician and irrigation subcontractors. Email stating request attached. 3. APPROXIMATE COST CHANGE TO CONTRACT PRICE: Add $5,614.00 4. WILL THE CONTRACT NEED ADDITIONAL CONTRACT TIME TO COMPLETE THE CHANGE IN WORK SCOPE? -YES X -NO -(CALENDAR DAYS) 5. WILL THE CONTRACTOR NEED ADDITIONAL PERSONNEL TO COMPLETE THE CHANGE IN WORK SCOPE? -YES X -NO IF NO, TRADE(S): Electrical Subcontractor installing along with other scope items. NO. OF PERSONNEL: 1 DURATION: approximately 2 days per roundabout location 6. IDENTIFICATION OF ATTACHMENTS: Series of three emails and photo attachments from Carmel Street Department requesting upgrades to electrical infrastructure not included in scope of gray Road contract. DATE: 6/25/2019 DATE: PREPARED REVIEWED BY: Smock Fansler REVIEWED BY: ENGINEER Comments and Recommendation: AR-5 Version 201 h-08-1 I Joe Davee From: Kalogeros, Mike <mkalogeros@carmel.in.gov> Sent Tuesday, November 27, 2018 2:33 PM To: Pease, Bradley Cc: Joe Davee;Williams, Ron D; Morris, Nathan Subject: New Project same Problems Attachments: IMG_0673.JPG;ATT00001.txt; IMG_0674.JPG;ATT00002.txt; IMG_0675.jpeg; ATT00003.txt; IMG_0678.JPG;ATT00004.txt;IMG_0679 jpeg;ATT00005.txt; IMG_ 0680.JPG;ATT00006.txt; IMG_0681.JPG;ATT00007.txt; IMG_0682.JPG;ATT00008.txt Hello Brad, I wanted to touch base with you reference the three RAB's currently under construction( Main, 126th,and 136th and Gray Road)? I know your working on a solution to the P1 problem but in the mean time who is working on these issues?I should first clarify if this is your project and if not can you direct me to the right individual for discussion please? The only information I have is that Smock Fansler is the GC and Barthuly is doing the irrigation.The Street Department hasn't been forwarded any other information on these RAB areas?I did find out that there is lightning being planned for these areas and I believe the lightning packages are ordered?This is where the project gets interesting,where are we going to mount the equipment in the current P1 cabinets? I have attached pictures of all three P1 cabinets in question and they are all different?There currently aren't enough outlets, NO mounting plates for equipment,with the Communications Rack installed can we get everything in the current cabinet at Main and Gray?These are all questions that will be put in our lap to answer when installation is started?Some of the contractors feel it's our responsibility to have the cabinets ready for them to install there equipment and when they aren't ready we get dinged for change orderers! I personally have a hard time paying twice for things that should have been completed with the initial installation,there are times where changes need to be made that's normal but in this case all three P1 cabinets need attention and upgrades? The project hasn't been released to the Street Department however, I am the one starting to get phone calls about water tap locations as one example.When doing a pre inspection to get a handle on the progress with construction that's when I starting finding issues?It would appear that weather is starting to slow things down which means in the Spring everyone is going to be making up for lost time and there will be delays if we don't address some of these issues sooner rather than later. Please let me know your thoughts please? Respectfully, Mike Kalogeros Carmel Street Department 317-752-6057 Attachments from Mike K. email 11/27/2018: .,-- .. - ..,:•' . 2"...7%,...- , -;,--:•_.: \ ' ,-' • .• --rr--Y. i ., . 1 , i . . kAtAilitr'?' ii.ikt-44:•'• '1"k*.'• .- • , re • c, . . A .. ,‘• • 1 ..4... •••-•\-- ;t- ... r .,. , lit. I,itiff . ,,..i: . ... .. 1 k, I I I , , ;;Ijr-,,'''- ----...'.• ,, .... \ 1 .s •:i fft 0. ,- ._,.;4, . , .-.-t- .*y. ____. -._..._s‘. ..-. .,_,,:i . , . ...._j‘.._.....---- i: ":4—‘-' 4r `v '''' II r)•-! 3, . ;- '''._ .. , . a I --...m.......iimil -... , lip ., : • '-' ... - " t1- 'i'. - 1„ • •.. ., .,, / \ i - • .. ., .. 111 II 1 '''' -I..7-,!'"S - • _1 . -- 1 /.i / r .,„L. 4 •- ,.. f., -- _----.._ -•..''''•"\ .'....;;-'..% _ . . -..‘ .. . - -(cdi4///i - ir k _ e..:1-,-,4, ••••,, . \\ • = -.-..,4 4.... :7'7,-....;...I ,1 • -: ,. .:. Ilicic.,./ ; ),t , •..:1.,.V.,2:400 %ill r,... :--- ...: -__..!.A.A.... lV,, / - // - ' • , : '70: ...4.‘ do .1' is , r 1 aE a ;It rl ' Y r • ® z:i • 7 J _ 'I - „',ice+`: ,! i dj;F ,I Si Joe Davee From: Kalogeros, Mike <mkalogeros@carmel.in.gov> Sent: Thursday, November 29, 2018 1:24 PM To: Williams, Ron D; Morris, Nathan;Joe Davee; 'brett@barthulyirrigation.com' Cc: Kalogeros, Mike Subject: Gray Road Follow-up Attachments: IMG_0673.jpg Joe, Thank you for the update Joe. I defiantly would agree that on this project information has been less than available! am not pointing the finger at anyone and I am not trying to indicate your behind at all. I just feel it's my job to protect the City's interest with the irrigation and now lighting that is being installed on ever new project?My biggest concern is the Main and Gray P1?Communication doesn't have any equipment installed yet and usually all fits into their rack(see attached Photo. I need two(2) plugs one outlet for irrigation, landscape lightning has three (3)component's that needs power, plugging into a four(4)gang outlet doesn't work as well as having 2 single outlets,the plugs have different power supplies and they don't fit as well, I am sure Scott has a remedy? If you review the picture there isn't a lot of room?They have the main power feed on the right side of the cabinet and no mounting plate?We have four pretty good size components to be installed?This is the same issue we had on the Keystone RAB project? Scott installed two new P1 cabinets on Hazel Dell and they were correct. I can discuss with Scott Apple but I think we need another sub cabinet if you will mount on the back of this P1 similar to what we had to do at 136`h and Keystone?Even if we cram everything in this cabinet at some point maintenance has to be considered. That means power has to be feed through the existing P1 cabinet along with all the irrigation control wire etc.? I try to help bring these issues to the table in advance when I know about them to avoid all the up charges and changes. I haven't heard a word from Scott and I know from experience that if it's an extra task it's an additional charge and I understand that, but to my knowledge he hasn't seen the application sites?Assuming that they are all the same is a big mistake in Carmel as you well know. I also wanted to make sure that there was at least one GFI outlet somewhere in the center of the RAB?I haven't seen any prints but observation tells me you're putting up walls of some sort? Let me know what I can do to help remedy some of these issues. I talked to the water department and they are coordinating with me the tap for 136th and Gray RAB,supposed to dig one day and tap the next just not sure of which day FYI? Respectfully, Michael Kalogeros Carmel Street Department 3400 W 131 n Street Carmel, IN 46074 Irrigation and Fountains Office: 317-733-2001 Cell:317-752-6057 Fax:317-733-2015 mkalogeros@carmel.in.gov 1 Attachment from Mike K. email 11/29/2018: f 1N ; y- : arrl ` ' y110 ea la I ,` • r F Joe Davee From: Kalogeros, Mike <mkalogeros@carmel.in.gov> Sent Friday, November 30, 2018 2:44 PM To: Joe Davee;Williams, Ron D; Morris, Nathan Cc: Scott Apple; Kalogeros, Mike; Brett Berry Subject: Gray Road P1 Cabinets Attachments: IMG_0684.JPG;ATT00001.txt;IMG_0685.JPG;ATT00002.txt Joe, I have made modifications to 136 and Gray and 126 and Gray P1 cabinets so Apple electric should be able to install their landscaping lighting equipment in both those locations.We will however need additional electrical outlets at both of these locations? I have attached a photo for Main and Gray with the dimensions for two additional mounting plates, 12x20 and 20x30. It'll be a little tight but I believe the irrigation components can mount on the 12 x 20 mounting plate and the landscape lighting should mount on the 20 x 30 mounting plate?We may also need an additional outlet in this P1. Hopefully this makes Things a little easier to deal with and save Scott from making a trip up here to take a look at the cabinets. If I can be of any other assistance please don't hesitate to let me know? If I need to meet anyone on site let me know as well. Respectfully, Mike Kalogeros Carmel Street Department 317-752-6057 1 Attachment from Mike K.email 11/30/2018: , i,\ , iii .' ,': ' •1 \ at , ,. , 'i w x;: F !i 1 1r71 i i may. ) u . • ,I 4 �