HomeMy WebLinkAboutM000.11 1 1 _11LTI E%'IS7I145 2" DRAIN " ABOVE'IJ RELOCATE ABOVE CEILING a CONNECT INTO NEW DRAIN AS SHOWR 1 r� ti 5� INSTALL NEW' IC VENT UPT 1 CONNECT TO EXISTING� VENT PIPING EX 4' 0 Q 0 0 PLUMBING NOTES: � I I I I 1 I I I x w E-CO PLUMBING RENOVATION PLAN SCALE: 1/4" = 1'-0" I. CONTRACTOR 15 RESPONSIBLE FOR OBTAINING AND PAYMENT OF ALL PEWITS REQUIRED FOR ELECTRICAL WORK. 2. CONTRACTOR SHALL PROVIDE ALL MATERIAL AND LABOR AS REQUIRED TO ACHIEVE COMPLETE AND OPERATING SYSTEM. 3. PLUMBING FIXTURES, DRAINS AND OTHER COMPONENTS SHALL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS, SPECIFICATIONS AND THE INTENDED DESIGN LAYOUT, 4. PROVIDE FIXTURES OF TYPE, STYLE AND MATERIALS INDICATED. FOR EACH TYPE OF FIXTURE, PROVIDE TRIM AND FITTINGS INCLUDING FAUCETS, SUPPLIES, STOPS, TRAPS, TAILPIECES, WASTE NIPPLES, HANGERS. PLATES, BRACKETS, ANCHORS, SUPPORTS AND HARDWARE AND FASTENING DEVICES REQUIRED FOR A COMPLETE OPERATING INSTALLATION. 5. CONNECTION TO THE POTABLE WATER SUPPLY SHALL BE IN THE BUILDING AS INDICATED ON PLANS, CONTRACTOR SHALL COORDINATE ANY NECESSARY SHUT-DOUIN REQUIREMENTS WITH BUILDING OWNER. 6. POTABLE COLD WATER PIPING SHALL BY OF ANY LOCALLY APPROVED MATERIAL. THE COLD WATER PIPE EXTENSION SHALL BE INSULATED TO PREVENT CONDENSATION. SANITARY SEWER AND VENT PIPING SHALL BE PVC SEWER PIPE. ALL UNDERGROUND SELLER PIPE SHALL BE SCHEDULE 40 PVC WITH SOLVENT WELD FITTINGS, 1. CONTRACTOR SHALL PROVIDE ALL NECESSARY PIPE, PIPE SUPPORTS, ANCHORS, ETC. AS REQUIRED TO MAINTAIN ALIGNMENT AND PREVENT DEFLECTION ACCORDING TO ANSI/ASME STANDARDS AND REGULATIONS, AND SHALL INCLUDE EXPANSION LOOPS, EXPANSION OFFSETS AND/OR JOINT5 AS REQUIRED ON LONGER PIPE RUNS. B. CONTRACTOR 15 RESPONSIBLE FOR PROTECTING ALL WATER SUPPLY LINES FROM FREEZING AND CONDENSATION. INSULATION SHALL BE PROVIDED AND INSTALLED ON THE COLD WATER SUPPLY LINES, WHERE EXPOSED, TO PREVENT CONDENSATION. HOT WATER SUPPLY PIPING SHALL BE INSULATED WITH SERVICE JACKET TO PREVENT HEAT LOSS, S. PROVIDE SLEEVES FOR ALL PIPING PASSING THROUGH FLOORS, WALL5 AND CEILING5. 10, LOCATE ALL VALVES, CLEAN -OUTS, AND OTHER OPERABLE FIXTURES. REOUIRING ACCESS AND/OR MAINTENANCE, IN AN ACCESSIBLE LOCATION, It. DUE TO THE NATURE OF THE PROJECT, THE CONTRACTOR SHALL FIELD VERIFY ALL CONDITIONS. LOCATIONS. SIZES, ETC, OF EXISTING SANITARY AND WATER SUPPLY PIPING, PRIOR TO INITIATING ANY WORK. DO NOT SCALE DRAWINGS. 11 ALL PIPING SYSTEMS SHALL BE PRESSURE TESTED IN ACCORDANCE WITH ANSI/ASME CRITERIA. RELEASED FOR CONSTRUCTION 4AL REQUIREMENTS WITH DINER Subject to compliance with all regulations of State and meal Codes City of Cannel (� ' V"`MaxTcllaA�L %0 0 O i CAP DRAIN IN WALL 0 B•• A.F.F. FOR FUTURE USE i FIELD VERIFY EXISTING INVERT t INSTALL NEW 2" A5 5NOY01. EX 4" FROM TWINNED FURNACE 5 a 6 ON MEZZANINE FROM TWINNED FURRACE 3 A 4 ON MEZZANINE N6 S x +o Y I RELOCATE EXISTING �A 'a EX 10'x10" E '1PPLY GRILLE AS SHOWN w PLUMBING FIXTURE SCHEDULE WASTE MARK DESCRIPTION MANUFACTURER REMARKS / ACCESSORIES DRAIN VENT COLDUPPLHOT C-CO EXISTING WA TO REMAIN CLEAN -OUT MIXING VALVE WATTS PROVIDE & INSTALL AT ALL REQUIRED FIXTURES (SEE NOTE IT) OR EOUAL JA:tl 1 _ (LV1, LV2 & WS) RELOCATED EXISTING 2-COMPARTMENT, STAINLESS STEEL. 'D'SINK WA /2' 1/2' RELOCATED FROM EXISTING KITCHEN, INCLUDING FAUCET & GARBAGE DISPOSAL NOTES: al -PER 'IPL' 4165. REFEREHCING'ASSE' 1010, A TEMPERATURE LIMITING DEVICE, IN THE RANGE OF 1050 - IIO°. SHALL DE FRWIDE ON ALL 5INK5, LAVATORIES AND BATHS. MECHANICAL RENOVATION PLAN SCALE: 1/4' = 1'.0" MECHANICAL NOTES: THIS WORK SHALL INCLUDE ALL HEATING, VENTILATING AND AIR CONDITIONING SYSTEMS REQUIRED AS INDICATED ON THE DRAWINGS. AND INCLUDES BUT 15 NOT LIMITED TO HEATERS, FANS, FILTERS, CONTINUOUS DUCTS, DAMPERQ GRILLES, REGISTERS, DIFFUSERS DUCT INSULATICN AND ALL ACCESSORY ITEMS REQUIRED FOR A COMPLETE AND OPERABLE SYSTEMS. CONCEALED SUPPLY DUCTWI TRUNKS SHALL BE EITHER SHEET METAL OF THE PROPER GAUGE FOR THE DUCT SIZE AND AIR VOLUME HANDLED WITH IQ" INTERIOR INSULATION OR I ROD FIBERGLASS DUCT BOARD WITH VAPOR JACKET BRACED AS REQUIRED FOR THE DUCT SIZE AND AIR VOLUME HANDLED. ALL DUCTWORK SHALL BE SECURELY HUNG AND FASTENED TO PRIMARY AND SECONDARY STRUCTURAL MEMBERS ONLY. PROVIDE ALL NECESSARY ISOLATORS, CONNECTORS, DAMPERS AND VOLUME CONTROLS FOR A COMPLETE AND CONTROLLABLE MECHANICAL SYSTEM, GRILLES AND DIFFUSERS SHALL BE AS NOTED ON THE PLANS OR EQUAL, PROVIDE ALL NECESSARY SPIN -INS, TAKE -OFFS, DAMPERS. SUPPORTS, CONNECTORS AND MISC. ITEMS FOR A COMPLETE INSTALLATION. MECHANICAL CONTRACTOR SHALL INCLUDE ALL CONTROLS, CONDUIT AND CONTROL WIRING FOR ALL HVAC CONTROL SYSTEMS IN HIS WORK, MECHANICAL CONTRACTOR SHALL INCLUDE THE COST OF ALL REQUIRED PERMITS, LICENSES INSPECTIONS AND TESTS AS PART OF HIS WOK, ALL SUPPLY, RETURN. EXHAUST. ETC, DUCT DIMENSIONS ARE INTERIOR CLEAR FREE AREA. INSULATION 15 IN ADDITION TO SIZES SHOUN. COORDINATE ANY / ALL ADDITIONAL REQUIREMENTS WITH OWNER DIFFUSER SCHEDULE SYMBOL MANUFACTURER MOUNT LOCATION SIZE NOTES & ACCESSORIES EXISTING IM E-51 EXISTING SUPPLY LAY -IN 24' x 24' TO REMAIN CEILING E-S2 EXISTING DRYWALL 240 x 120 T O R E M A I N e SUPPLY WALL E-R EXISTING RETURN LAY -IN 240 x 240 TO REMAIN CEILING RELOCATE RELOCATE AS INDICATED EXISTING DRYWALL IS.X IS' R-S SUPPLY CEILING FIELD VERIFY SUPPLY STE PANELW/TDAMPER W/ 1-WAY ®Sl TITUS ORYKA.LL IS. x 18' M CEILING OR EQUAL COORDINATE FINISH At COLOR W/ OWNER. RETURN STEEL, FLAT PANEL. EGG -CRATE TUTUS DRYWALL ®Rl 16' x 16' OR EQUAL CEILING COORDINATE FINISH At COLOR W/ OWNER. GRILLE N/A a M.D. ARCHITECTS, PC 9084 TECHNOLOGY DRIVE FISHERS, IN 46038 TEL:317.558.2822 FAX:317.558.2872 www.mdarchitects.com IIIIII A KEELER - WEBB ASSOCIATES Consulting Engineers Planners - Surveyors 486 CRADLE DRIVE CARMEL. INDIANA 46032 317-574-0140 www keelerwebb-com Q Z ua Z J LU 2 Q U J LU Lr H 75 Tn I— CO N V f w O O V c Mo d Mw Z Oa mw ar 'n �V 7 �U 5� w r DATE: L)U/L)U/-I`J