HomeMy WebLinkAboutA000.2STANDARD MOUNTING
HEIGHTS
WALL LEGEND
CODE PLAN LEGEND
CODE REQUIREMENTS
EXISTING WALLS TO REMAIN
ALL WORK UNDER THIS CONTRACT SHALL COMPLY WITH THE PROVISIONS OF THE
SPECIFICATIONS & DRAWINGS AND SHALL SATISFY ALL APPLICABLE CODES, ORDINANCES,
FEC
= FIRE EXTINGUISHER CABINET
AD.A., AND REGULATIONS OF ALL GOVERNING BODIES INVOLVED. ANY MODIFICATIONS TO
M
FLASHING STATION
NEW WALL CONSTRUCTION, NONINSULATEDTHE
CONTRACT W ORK REQUIRED BY SUCH AUTHORITIES SHALL BE AT THE EXPENSE OF THE
M
(WHERE APPLICABLE)
OWNER, SUBJECT TO THE RECEIPT OF AN AFFADAVIT OR LETTER FROM THE GOVERNING
BODY AND OWNER'S PRIOR APPROVAL OF ANY ADDITIONAL COST TO BE INCURRED. ALL
M.D. ARCHITECTS, PC
KEY! PARTIAL HEIGHT INSULATED WALL
= SURFACE MOUNTED FIRE
PERMITS AND LICENSES NECESSARY FOR THE PROPER EXECUTION OF THE WORK SHALL BE
908/ TECHNOLOGY DRIVE
-
CONSTRUCTION
EXTINGUISHER
SECURED AND PAID FOR BY THE CONTRACTOR INVOLVED.
FISHERS, IN 48038
T-19"
6.
TEL:317558.2822
o O
-� _ _ _
CARD READER b
NEW FULL- HEIGHT INSULATED WALL
CONSTRUCTION
---�
PATH OF EGRESS
APPLICABLE CODES INCLUDE, BUT ARE NOT LIMITED TO THE FOLLOWING:
FAX 27
O
(WHERE APPLICABLE)
o
d
o `°
i
LIGHT SWITCH
BUILDING CODE: 2014 INDIANA BUILDING CODE (COMPRISED FROM20121NTL. BUILDING CODE)
0 o 0
<
O O
p
(WHERE APPLICABLE) -
F
\\ /
EXISTING DOOR TO REMAIN
����M
FIRE BARRIER
MECHANICAL CODE: 2014 INDIANA MECHANICAL CODE (COMPRISED FROM 20121NTL. MECHANICAL CODE)
w
g o
}f`''
RECEPTACLE J fD
(WHERE APPLICABLE)
FIRE EXIT
PLUMBING CODE 20121NDIANA PLUMBING CODE (COMPRISED FROM 20761N7L. PLUMBING CODE)
f
NEW DOOR TO BE INSTALLED
ELECTRICAL CODE: 2009INDIANA ELECTRICAL CODE (COMPRISED FROM NFPA 70 2008)
DATA/ PHONE RECEPTACL
HI-LO WATER HI-LOWATER
14ANDICAPPED"HI-DO" ELECTRIC
FIRE CIRCUIT
SECURITY
THERMOSTAT FIRE ALARM ELECTRICAL
(WHERE APPLICABLE)
�
ENERGYCODE: 2010 INDIANA ENERGY CONSERVATION CODE (COMPRISED FROMASHRAE90.h2M7)
COOLER W/ COOLER W/
WATER COOLER FIRE ALARM EXTINGUISHER BREAKER BOX CONTROLS
PULL SWITCH
BOTTLERLLER BOTTLE FILLER
HORN
ALL NEW OR ALTERED SWITCHES, CONTROLS, SECURITY KEYPADS,
ACCESSIBILITY 2014 INDIANA BUILDING CODE (CHAPTER I I ACCESSIBILITY)(COMPRISED FROM 678
(SIDE VIEW)
CREDIT DEBIT CARD SWIPES, ELECTRONIC LOCKSETS, PUBLICALLY
CODE: IAC 13 2.6-12 CHAPTER 11)
VCA STANDARD
NON-VCA STANDARD
ACCESSED TSTATS, COAT HOOKS, WALL PHONES, ETC WILL COMPLY
WITH THE REACH QUALIFICATION STANDARDS OF ICGANSI At 117.1
FIRE CODE: 2014 INDIANA FIRE CODE (COMPRISED FROM 012 INTL. FIRE CODE)
SECTIONS 308 AND 309.
BUILDING INFORMATION
FIRE AREA
EXISTING OFFICES & ASSEMBLY
8223SFTOTAL
OCCUPANCY: A3 ASSEMBLYCHURCH(PER SEC DON 303)
19645F OFFICES @ 100SF/OCC = 20OCC.
87CSF UNCONCENTRATED @ 15SFDCC =58 OGG.
53898F STANDING ASSEMBLY @ 5SF/OCC=1078 OCC.
TOTAL =1156 OCCUPANT LOAD
CONSTRUCTION TYPE: ORIGINAL BUILDING PLANS INDICATE TYPE V-B MOT SPRINKLERED) (PER
4 EXITS REWIRED PER IBC. 1015.1.1
SECTION W2.3). ALL NEWCONS7RUC71ON COMPLIES WITH VRB CONTRUCTION.
4 EXITS PROVIDED
TOTAL AREA OF EXISTING BUILDING:481625F
PER IBC 1014.3 COMMON PATH OF TRAVEL DOES
TOTAL AREA OF WORK: AREAL DAYCAREAREA-1205SF
7
NOT EXCEED 751N AN UNSPRINKLERED BUILDING
AREA 2- HALLWAY, CONFERENCE& COFFEE AREA 1440SF
L
PER IBC 1016.2(NOTSPRINKLERED) MAX TRAVEL
ARF43-LIBRARY, KITCHEN, SANCTUARYDOORS -873SF
TO AN EXITDOESNOT EXCEED 200'.
AREA 4-CHOIR ROOM -1424SF
O
PER IBC 1015,1 OFFICE SPACES DO NOT EXCEED
MAXIMUM OCCUPANT LOAD OF 49 SO ONE EXIT TO
TOTAL AREA OF WORK -4950SF
C0
EXITACCESS DOORWAY
TIRE AREA 3
C')
EXISTING FELLOWSHIP WING
O
NUMBER OF STORIES: 1(1 ALLOWABLE PER TABLE 503) WITH BASEMENT IN DA YCARE WING
CD
9389SF UNCONCENTRATED TABLES & CHAIRS @ISSF/OCCUPANT
Q V
OCCUPANT LOAD: "ales of woM s.f."/sf PER OCCUPANT (PER CHAPTER 10, TABLE 1004. 1.2)
EXIT =701 OCCUPANT LOAD
3 EXITS REQUIRED PER IBC. 1015.1.1
> Q
FIRE AREA
FIRE AREA2
3EXITS REQUIRED
= jSEENOTES ON PLAN, THIS SHEE77 OCCUPANTS
Z
EXISTING DAYCARE WING
TOTAL AREACAREF
-
PER IBC 1014.3 COMMONPATH OF TRAVEL DOES
(SEE NOTES ON THIS SHEE77EXITS REQUIRED, [SEEPLANIPROVIDED
Q
O
NOT EXCEE076 IN AN UN-SPRINKLERED BUILDING
CLASSROOMS @20SF/OCCUPANT
r
PER IBC 1016.2 MOT SPRINKLERED) MAX. TRAVEL
TO AN EXITDOES NOT EXCEED 200'.
MAX TRAVEL_200-0"(f0f6.2,) 'A'000UPANCY-NOTSPRINKLERED
DISTANCE:
z Z
Z
5,710 SF 120
= 286 OCCUPANT LOAD
2 EXITS REQUIRED
II
III n II
I
PER INC 10151 OFFICE SPACES DO NOTEXCEED
MAXIMUM OCCUPANT LOAD OF 49 SO ONE EXIT TO
-
w _J
Q
3 PROVIDED
- �y�
L�
J
EXITACCESS DOORWAY
MAX COMMON PATH = ]50"(f0f4.3, A30CCUPANCY-NOT SPRINKLERED)
OFEGRESS TRAVEL
W
Q
PER IBC PATH DOES
f0f43COMMON OFTRAVEL
EXISTING FIRE BARRIER
_ �TAµCE157T
- - - -
NOTEXCEEO 75',
PER IBC 10162 MAX EXITACCESS DISTANCE
(SPRINIQERED)DOESNOTEXCEED250'.
CONSTRUCTION TO
REMAIN
r Eyy�ppCES'
r MNX.
� �
1 �\ U
J
MAX DEAD END =5d-0"(PER SECTION f0184, EXCEPTION 2)('B, E'OCCUPANCY-NOT SPRINKLERED
CORRIDOR:
Q
C 1)
load X0.2"(FACTOR PER SECTION 1018.2)
\
v U
LL
PER INC 1015.1 INDIVIDUAL CLASSROOM SPACES DO
NOTEXCEED MAXIMUMOCCUPANTLOAD OF49SO
ONE EXITTO EXITACCESS DOORWAY.
1 J1
- �) / ,(�
- \
III L
MIN. EGRESS = occupant
CORRIDOR WIDTH:=OCCUPANCYA3, 8-USE 44"MIN, OCCUPANCY E-72"MIN,
�
LL
z
EXIT
FIRE AREA
EXIT
FIRE AREA I
/� 1
L�
III
//
K
MIN, EGRESS SEE CODE NOTES ON SHEETA6.4 FOR BASEMENTSCOPE OF WORK.
EXIT
X. EXIT ACCESS DISTANCE IS 92'< 2W
EXIT
STAIRWAYWIDTH:
O
4 \
.
/ /
��`�
^yI
r
IREAREA3
U
�t
-�
[
/
MIN. DISTANCE EXIT OR EXIT ACCESS DOORWAYS MUST BE PLACED APART FROM EACH
BETWEEN EXITS: OTHER 113 THE LENGTH OF THE OVERALL DIAGONAL DIMENSION OF AREA
=
III
/
SERVED (PER 10152.1, EXCEPTION 2).
CD
III
��
NEW CORNER CAFE'
EXIT POSITIONS ARE EXISTING AND ADEQUATELY SPACED.
EXIT
�
/
/
PROJECT NOTES
LLI
�� "
FIREAREAI
- -� L - -
- <�
��
�-'°
-
L_ MAX. EXIT ACCESS DISTANCE IS 79'< 250'
p- EXIT
\/
A�
III
/
THI S PROJECT IS AN INTERIOR RENOVATION ONLY AND DOES NOT INVOLVE ANY
CO
I�
FIRE AREA 2
/
FIRE AREA 2
IRE AREA 3
ADDITION. IT IS ALSO NOT A CHANGE IN USE
�
` ,III
If v
_ \
�// o �
�-
THE EXISTING BUILDING IS SEPARATED INTO DIFFERENT FIRE AREAS BY FIRE
BARRIERS SEE PLAN ON THIS SHEET. THESE AREAS HAVE VARYING USES WHICH ARE
ACCESSORY USES TO THE PRIMARY CHURCH FUNCTION.
r^
RENOVATIONS PLANNED IN DAYCARE AREA ARE TO THE ENTRANCE TO THE EXISTING
(�
UNLICENSED, REGISTERED CHILD CARE MINISTRY, AND IS AN ACCESSORY USE TO THE
/
ATRIUM
@
/
IREAREA4
PRIMARY CHURCH (A-3) OCCUPANCY.
EXIT
RENOVATION AT SANTUARY ENTRANCE (SEE SHEET NO. A6.I FOR WORK AREA 3) IS
�
COURTYARD
/
IRE FIRE AREA
TO CHANGE DOOR SWING TO SUPPORT EGRESS REQUIREMENTS OUT OF THIS AREA
FOR DA YCARE WING BASEMENT SEE
EXISTING FIRE BARRIER
CONSTRUCTION TO
REMAIN FIRE AREA 11
6/
sn�'/
5
�
COURTYARD EXISTING FIRE BARRIER
CODE NOTES ON SHEET A6.4
CONSTRUCTION TO REMAIN
EXISTING FIRE BARRIER
ate/ f'II
/
CONSTRUCTION TO
@ / Q
CURRENT FIRE EXIT IS INTO ENCLOSED
REMAIN
\
/ EXIT A
COURTYARD. WORK PROPOSED IN THIS AREA
'�D RENSC
/ FIRE AREA5�r�� (SEE PLANS ON SHEET NO. A6.3 FOR 'WORK
AREA4-)INTENDS TO PROVIDE A MORE
r
EFFECTIVE EXIT OPTION OUT OF THE HRE AREA.
o,
•""""
EXISTING FIRE BARRIER
FIRE
AREA
EXIT
CONSTRUCTION TO
FIRE AREAS �
REMAIN
t1o. 199000A8 [� E
- S7 e
S
D
C„N�
EG
I
EXIT
ryg
FIRE AREAS \
4L
\ d
MECHARICALYARDRE
ti
AREA
�
FIRE AREA I
w
FIRE AREA EXISTING FIRE I y EXISTING TEEN EDUCATION WING
EXISTING SANCTUARY
W
BARRIER eY
CONSTRUCTION
7615SF TOTAL @20SROCCUPANT
= 381 OCCUPANT LOAD
a
B
^
TOTAL AREA 10212SF
TO REMAIN
2EXITS REQUIRED PER IBC. 1015.1.1
"
FIXED SEATS-570 a 3EXITS PROVIDED
STANDING ASSEMBLY 49WSF @ 5SFOCC =1000 OCC. LOAD
PER IBC 1014.3 COMMON PATH OF TRAVEL DOES
ASSEMBLY CONCENTRATED CHAIRS ONLY -2212 @ 7SF/0CC.=316 GC C. LOAD
��
NOTEXCEED 75!
TOTAL OCCUPANT LOAD -18M
PER IBC 10162 MAXEXITACCESS DISTANCE
4 EXITS REQUIRED PER IBC. 1015.1.1
(UNSPRINKLERED) DOES NOT EXCEED200'.
r
4 PROVIDED
PER IBC 10151 INDIVIDUAL CLASSROOM
w
h
OF DOES
PER 10EED
COLUMBARIUM COURTYARD
SPACES DO NOTEXCEED MAXIMUMOCCUPANT
7. IN AN UNNPAT
KLEREDTRAVEL
NOTEXCEED IN AN UNSPRINKLEREO BUILDING
LOAD OF 49 SO ONE EXIT TO EXITACCESS
PER IBC 1016.2 (UNSPRINKLERED) MAX. TRAVEL TO
EXIT
DOORWAY
o
LL
AN EXIT DOES NOT EXCEED 2W'
FIRE AREAS
w
XIT
¢
FIRE AREA4
y
0
N
3
2
S
_
0
a
rc
o
z
Z
W O
O
EXIT
FIRE AREA
3tj
RELEASED FOR CONSTRUCTION
>w°LL_�
w:oi z i�w
Subject to compliance with all regulations
>�a
Doti coo
of State and local Codes
2 CODE
PLAN
aw�w wtS
36
City at caimel
AD.1 1 150
o
m
„w E €3LL
a? o w
6
DATE: 09/09/ 19