HomeMy WebLinkAboutM001.0IECC 2009 Performance Compliance
Property
7161 ANTIQUITY DR
CARMEL, IN 46033
Model: STOCKBRIDGE
Community: THE GROVE AT LEGA(
GL192A (AS DESIGNED)
THE GROVE AT LEGACY 192A
Organization
TSI Energy Solutions
Devin Sielschott
Builder
PYATT BUILDERS, LLC
Design
Heating
Cooling
Water Heating
SubTotal - Used to determine compliance
Lights & Appliances
Onsite generation
Total
Inspection Status
Results are projected
Annual Energy Cost
IECC 2009 Performance
51,122
$170
$313
$1,605
$780
$0
$2,385
Requirements
C-M,
Energy Solutions
As Designed
51,106
S175
S313
$1,594
S757
SO
$2,360
C4405.3 Performance -based compliance passes by 0.7%
R402.4.12 Air Leakage Testing Air sealing is S.DD ACH at 5D Pa. It must not exceed 7.DD ACH at 50 Pa.
C4402.5 Area -weighted average fenestration SHGC
402.5 Area -weighted average fenestration U-Factor
40322 Duct Testing
Mandatory Checklist Mandatory code requirements that are not
checked by Ekotrope must be met.
R4052 Duct Insulation
Design exceeds requirements for IECC 2009 Performance compliance by 0.7%.
As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of
Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with
the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been
inspected/tested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC orwill be verified as such by another party.
Name: Devin Sielschott
Organization: TSI Energy Solutions
Signature:
Date:
913119at12:07PM
Ekotrope RATER - Version 3.1.0.2243
IECC 2009 Performance compliance results calculated using Ekotrope RATER's energy and code compliance algorithm.
Ekotrope RATER is a RESIN ET Accredited HERS Rating Tool. All results are based on data entered by Ekotrope users.
Ekotrope disclaims all liability for the information shown on this report.
7161 ANTIQUITY DR
CAR M E L, IN 46033
Builder: PYATT BUILDERS, LLC
Ceiling Attic, R-38
Above Grade Walls R-15
Foundation Walls NIA
Framed Floor NIA
Slab R-10.0 Perimeter, R-10.0
Under
Infiltration 5 ACH50
Window U-Value: 0.28, SHGC: 0.31
Building Features
Duct Supply R-20.0, Return R-15.0
Duct Leakage to Outside 103 CFM25 (4.541100 s.f.)
Total Duct Leakage 253 CFM25 (Post -Construction)
Heating Furnace • Natural Gas • 92.1 AFUE
Cooling Air Conditioner • Electric • 13 SEER
Water Heating Water Heater • Electric • 0.93 Energy Factor
As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of
Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. It rating is Projected, I certify that the building design described herein is consistent with the
building plans, specifications. and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and
that the mandatory provisions of the I ECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party.
Name: Dlevin Sielschott
Organization: TSI Energy Solutions
Signature:
Date: 913119 at 12:07 PM
Ekotrope RATER - Version 3.1.0.2243
20091ECC compliance results calculated using Ekotrope RATER's energy and code compliance algorithm.
Ekotrope RATER is a RESIN ETAccredited HERS Rating Tool. All results are based on data entered by Ekotrope users.
Ekotrope disclaims all liability for the information sh own on this report.
Energy Code Inspection Checklist
Property Organization
7161 ANTIQUITY DR TSI Energy Solutions
CARMEL, IN 46033 Devin Sielschott
Model: STOCKBRIDGE
Community: THE GROVE AT LEGAL Builder
PYATT BUILDERS, LLC
GL192A (AS DESIGNED)
THE GROVE AT LEGACY 192A
General Building Information
Conditioned Area (sq ft) 2,267
Conditioned Volume (cubic ft) 23,098
Insulated Shell Area (sq ft) 6,873
inspection Status
Results are projected
C",
Energy Solutions
The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy
features will change in the field from what has been modeled. The inspection process should identify any changes and ensure
that the home continues to meet the applicable energy code.
Slab
Name: SLAB(1,685 s.f., 156 ft. exterior perimeter)
R-10 perimeter insulation, R-10 under slab insulation.
Framed Floor
None Present
Foundation Wall
None Present
Above Grade Wall
El Name: CONDIAMB (2,501 s.f.)
R-0 continuous insulation, R-15 cavity insulation
Insulation Grade: I
El Name: CONDIGAR (630 s.f.)
R-0 continuous insulation, R-15 cavity insulation
Insulation Grade: I
Name: CONDIATTIC (212 s.f.)
R-0 continuous insulation, R-15 cavity insulation
Insulation Grade: I
Name: CONDICOND (160 s.f.)
R-0 continuous insulation, R-22 cavity insulation
Insulation Grade: I
Energy Code Inspection Checklist
Property
7161 ANTIQUITY DR
CARMEL, IN 46033
Model: STOCKBRIDGE
Community: THE GROVE AT LEGAL
GL192A (AS DESIGNED)
THE GROVE AT LEGACY 192A
Rim Joist
None Present
Roof
Organization
TSI Energy Solutions
Devin Sielschott
Builder
PYATT BUILDERS, LLC
Name: MAIN (1,685 s.f.)
R-27.55 continuous insulation, R-10.15 cavity insulation
Insulation Grade: I
Opaque Door
Name: FRONT (20 s.f.)
U: 0.182
Name: GARAGE (18 s.f.)
U: 0.182
Glazing
Inspection Status
Results are projected
E] Name: FRONT (60 s.f.), U: 0.280, SHGC: 0.31, Orientation: SOUTH
El Name: SLIDER (120 s.f.), U: 0.280, SHGC: 0.31, Orientation: NORTH
El Name: BACK(168 s.f.), U: 0.280, SHGC: 0.31, Orientation: NORTH
El Name: LEFT SIDE (109 s.f.), U: 0.280, SHGC: 0.31, Orientation: WEST
11 Name: SLIDER (48 s.f.), U: 0.280, SHGC: 0.31, Orientation: WEST
11 Name: RIGHT SIDE (34 s.f.), U: 0.280, SHGC: 0.31, Orientation: EAST
Skylight
None Present
Mechanical Ventilation
C",
Energy Solutions
2
Energy Code Inspection Checklist
TSI Energy Solutions
Property Organization Inspection Status
7161 ANTIQUITY DR TSI Energy Solutions Results are projected
CARMEL, IN 46033 Devin Sielschott
Model: STOCKBRIDGE
Community: THE GROVE AT LEGAL Builder
PYATT BUILDERS, LLC
GL192A (AS DESIGNED)
THE GROVE AT LEGACY 192A
ElMechanical ventilation system rated for, and capable of, providing continuous ventilation.
System shall include automatic timing controls.
System type: Exhaust Only, 24 hrslday, 8 Watts.
Mechanical Equipment
El Fuel -fired air distribution • Natural Gas • 100% Heating Load @ 92.1 AFUE
0 Air conditioner • Electric • 100% Cooling Load @ 13 SEER
Water Heating • Electric • 100% Hot Water Load @ 0.93 Energy Factor
Air Leakage Control
ElTest Status: Blower -door tested
House is air -sealed as to achieve 1,925 CFM50 (5.00 ACH50) or less at final blower -door test.
Infiltration Requirements for IECC in Climate Zone 5
2009 IECC Infiltration limit for the design home is 7 ACH50.
2012 IECC Infiltration limit for the design home is 3 ACH50.
2015 IECC Infiltration limit for the design home is 3 ACH50.
Duct Leakage
Duct System 1
NOT entirely within conditioned space, testing required
Leakage to Outside specified as: 103 CFM25 (4.541 100 s.f.)
Total Leakage specified as: 253 CFM25 (Post -Construction)
3
Energy Code Inspection Checklist
Property Organization
7161 ANTIQUITY DR TSI Energy Solutions
CARMEL, IN 46033 Devin Sielschott
Model: STOCKBRIDGE
Community: THE GROVE AT LEGAL Builder
PYATT BUILDERS, LLC
GL192A (AS DESIGNED)
THE GROVE AT LEGACY 192A
Duct Leakage Code Requirements for IECC
2009 IECC:
Inspection Status
Results are projected
Postconstruction Leakage Test: Duct Leakage to Outdoors t= 8 CFM25 / 100 sq ft CFA.
Rough in Test with AHU: Total Duct Leakage <= 6 CFM25 / 100 sq ft CFA.
Rough in Test without AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
2012 IECC and 2015 IECC Prescriptive Path:
Postconstruction Leakage Test: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
Rough in Test with AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
Rough in Test without AHU: Total Duct Leakage <= 3 CFM25 / 100 sq ft CFA.
2015 Performance Path (Cost Compliance):
C",
Energy Solutions
Leakage testing is required UNLESS all ducts and air handlers are located entirely within the thermal envelope.
There is no pass/fail threshold for duct leakage on the performance path.
Project Notes
4
Building Summary
Property
7161 ANTIQUITY DR
CARMEL, IN 46033
Model: STOCKBRIDGE
Community: THE GROVE AT LEGACY 192A
GL192A [AS DESIGNED]
THE GROVE AT LEGACY 192A
enera?Building Information
Number Of Bedrooms
Number Of Floors
Conditioned Floor Area [sq_ ft.]
Unconditioned, attached garage?
Conditioned Volume [cu. ft.]
Total Units in Building
Residence Type
Floor Number
Model
Community
Climate Zone
Foundation Wall
Foundation Wall Library List
Slab
Organization Inspection Status
TSI Energy Solutions Results are projected
Devin Sielschoft
Builder
PYATT BUILDERS, LLC
3
2
2;267
Yes
23;498
1
Duplex, single unit
STOCKBRIDGE
THE GROVE AT LEGACY 192A
5A
None Present
None Present
Masonry Area
C-M,
Energy Solutions
n
SLAB R-10, 1'down, 2' in 156
On Grade 1.23
0 1:665.0 R' Exposed Exterior
Conditioned
Space
Slab Library List
Name Wall Construction Slab Completel Underslab Perimeter
Perimeter Thermal Break
Effective R-value
Type Insulated. Insulation
Width [ft] Insulation Depth [ft]
Insulation R Value
R-10, 1'down, 2' in Wood Frame /Other No
2 1
10 No
10.00
Framed Floor
None Present
1
Building Summary
Property
Organization
7161 ANTIQUITY DR
TSI Energy Solutions
CARMEL, IN 46033
Devin Sielschoft
Model: STOCKBRIDGE
Community: THE GROVE AT LEGACY 192A
Builder
PYATT BUILDERS, LLC
GL192A [AS DESIGNED]
THE GROVE AT LEGACY 192A
Framed Floor LibraryLis#
iiM��
None Present
Rim Joist
Rim Joist Library List _
None Present
Wall
Inspection Status
Results are projected
C-M,
Energy Solutions
Name
Library Type
Surface Color
Surface Area
Location
CONDIAMB
Exposed Exterior
G1 R-15 BATT, OSB
Medium
2.501.0 ft'
CONDIATTIC
Attic
G1 R-15 BATT, OSB
Medium
212.0 ft'
CONDICOND
Conditioned Space [Adiabatic]
G1 R-22 Dbl Wall
Medium
160.0 ft'
CONDIGAR
Unconditioned, attached garage
G1 R-15 Gar Walls
Medium
630.0 f[s
Wall Library List
Name
Effective R value
G1 R-15 BATT, OSB
13.423
G1 R-15 Gar Walls
11.972
G1 R-22 Dhl Wall
18.407
2
Building Summary
Property Organization Inspection Status
7161 ANTIQUITY DR TSI Energy Solutions Results are projected
CARMEL, IN 46033 Devin Sielschott
Model: STOCKBRIDGE
Community: THE GROVE AT LEGACY 192A Builder
PYATT BUILDERS, LLC
GL192A [AS DESIGNED]
THE GROVE AT LEGACY 192A
Rlazin
Name Library Type Wall Assignment Foundation Wall Overhang Depth Overhang Ft To
Assignment Top
Overhang Ft To
Bottom
Energy Solutions
C-M
Orientation Surface Area
BACK 11-28, SHGG.31
CONDIAMB
0
0
❑
North
168.0 fts
FRONT 11-28, SHGG.31
CONDIAMB
❑
0
❑
South
60.0 fF
LEFT SIDE 11-28, SHGC-.31
CONDIAMB
❑
0
❑
West
109.0 R2
RIGHT SIDE 11-28, SHGG.31
CONDIAMB
0
0
❑
East
34.0 ft
SLIDER U-28, SHGC-.31
CONDIAMB
0
0
❑
North
1200.fts
SLIDER U-28, SHGG.31
CONDIAMB
0
0
0
West
48.0 fF
Glazing Library Li
Name
Shgc
U -factor
U-28, SHGC-.31
0.31
0280
Skylight
None Present
Skylight Library List
None Present
Opaque Door
Name Library Type Wall Assignment Foundation Wall
Emi tance
Solar
Surface Color
Surface Area
Location
Assignment
Absorptance
FRONT Steel Door
CONDIAMB
0.9
0.75
Medium
20.0 f'
Exposed Exterior
GARAGE Steel Door
CONDIGAR
0.9
0.75
Medium
18.0 fts
Exposed Exterior
Building Summary
Property
C-MEnergy Solutions
Organization Inspection Status
7161 ANTIQUITY DR
TSI Energy Solutions Results are projected
CARMEL, IN 46033
Devin Sielschott
Model: STOCKBRIDGE
Community: THE GROVE AT LEGACY 192A
Builder
PYATT BUILDERS, LLC
GL192A [AS DESIGNED]
THE GROVE AT LEGACY 192A
POpaque Door Library List
Name
Effective U-factor
Steel Door
0.182
Roof Insulation
Name Library Type Attic Exterior Area Clay or Concrete Roof Surface Color Surface Area Location
V11.1 Tiles
f;1AIN R-38 Blown, GR1 1,685 No Medium 1.685.0 fts Attic
Roof Insulation Library List
Name Has Radiant Barrier Effective R-value
'•0 ? :a l No 38268
Whole House Infiltration
Infiltration Measurement Type
5 ACH at 50 Pa Blower -door tested
Mechanical Ventilation
Ventilation Type Ventilation Rate �fta! Operational hours per day
Minute]
Exhaust Only 24 24
Lighting
% Interior Fluorescent % Interior LED Lighting % Exterior Fluore
Lighting Lig
0 ❑
Shelter Class
4
Fan Watts Runs once every three Energy Recovery Percent
hours
8 Yes
4
Building Summary
Property
Organization
7161 ANTIQUITY DR
TSI Energy Solutions
CARMEL, IN 46033
Devin Sielschott
Model: STOCKBRIDGE
Community: THE GROVE AT LEGACY 192A
Builder
PYATT BUILDERS, LLC
GL192A [AS DESIGNED]
THE GROVE AT LEGACY 192A
rnsite Generation
None Present
Gnsite Generation Library List I
None
Solar Generation
None Present
Solar Generation Library List
None Present
Conditioning Equipment
Inspection Status
Results are projected
C-M,
Energy Solutions
Name
Library Type
Heating Percent Load
Cooling Percent Load
Hot Water Percent Load
Location
Air conditioner
CA13NA036
0%
100%
❑%
Conditioned Space
Fuel4red air 9125A4B060517 100% 0% ❑% Conditioned Space
distribution
Water Heating ENT 50 100 0% 0% 100% Conditioned Space
Equipment Type: 912SA48060S17
Fuel Type Natural Gas
Distribution Type Forced Air
Motor Type PSG (Single Speed)
Heating Efficiency 92.1 AFUE
Heating Capacity [kBtulh] 56
Use default EAE No
EAE [kWh] 649
A
Building Summary
Property
7161 ANTIQUITY DR
CARMEL, IN 46033
Model: STOCKBRIDGE
Community: THE GROVE AT LEGACY 192A
GL192A [AS DESIGNED]
THE GROVE AT LEGACY 192A
■
quipment Type:
Fuel Type
Distribution Type
Motor Type
Cooling Efficiency
Cooling Capacity [kBtulh]
CA13NA036
Equipment Type: ENT 50 100
Fuel Type
Distribution Type
Hot Water Efficiency
Tank Capacity (gal.)
Hot Water Capacity [kBtulh]
Recovery Efficiency
Organization
TSI Energy Solutions
Devin Sielschott
Builder
PYATT BUILDERS, LLC
Electric
Forced Air
PSG (Single Speed)
13 SEER
34.2
Electric
Hydronic Delivery
0.93 Energy Factor
50
15.4
❑.99
Inspection Status
Results are projected
C-M,
Energy Solutions
Building Summary
Property
7161 ANTIQUITY DR
CARMEL, IN 46033
Model: STOCKBRIDGE
Community: THE GROVE AT LEGACY 192A
GL192A [AS DESIGNED]
THE GROVE AT LEGACY 192A
1butivn System
Lion Type
Equipment
Equipment
t Served
i Grilles
Xct R Value
]uct R Value
Xct Area r]
]uct Area [ft2]
5 to Outdoors
akage
akage Duct Test Conditions
fault Flow Rate
cation
Supply Area
Return Area
cation
Supply Area
Return Area
cation
Supply Area
Return Area
cation
Supply Area
Return Area
cation
Supply Area
Return Area
cation
Supply Area
Return Area
rCeiling Fan
Has Ceiling Fan
Cfm Per Watt
Organization
TSI Energy Solutions
Devin Sielschott
Builder
PYATT BUILDERS, LLC
Forced Air
Fuel -fired air distribution
Air conditioner
2267
2
2❑
15
612.09
226.7
103 CFM25 (4.541 100 s.f.)
253 CFM25
Post -Construction
Yes
Attic (well vented; under insulation)
75
50
Conditioned Space
25
5❑
Conditioned Space
0
0
Conditioned Space
Conditioned Space
Conditioned Space
No
Inspection Status
Results are projected
C-M,
Energy Solutions
7
Building Summary
Property
7161 ANTIQUITY DR
CARMEL, IN 46033
Model: STOCKBRIDGE
Community: THE GROVE AT LEGACY 192A
GL192A [AS DESIGNED]
THE GROVE AT LEGACY 192A
ater Distribution
Water Fixture Type
Use Default Hot Water Pipe Length
Hot Water Pipe Length [ft]
At Least R3 Pipe Insulation?
Hot Water Recirculation System?
Recirculation System Pipe Loop Length [ft]
Drain Water Heat Recovery?
Clothes Dryer
Fuel Type
Cef
Field utilization
Clothes Washer
Label Energy Rating
Electric Rate
Annual Gas Cost
Gas Rate
Capacity
I met
Appliances and Controls
Programmable thermostat?
Dishwasher Size
Dishwasher Efficiency
Range/Oven Fuel
Convection Oven?
Induction Range?
Refrigerator Consumption
Organization Inspection Status
TSI Energy Solutions Results are projected
Devin Sielschott
Builder
PYATT BUILDERS, LLC
Standard
No
25
No
No
10
No
Electric
Timer Controls
ff"W
704 kWh/Year
$0.081kWh
$23.00
$0.581Therm
2.874
❑.33053
Yes
Standard
270 kWh
Natural Gas
No
No
709 kWh/Year
"M �
C-M,
Energy Solutions
,�