HomeMy WebLinkAboutM001.0IECC 2009 Performance Compliance Property 7167 ANTIQUITY ❑R CARMEL, IN 46033 Model: GEORGETOWN Community: THE GROVE AT LEGA( GL192B (AS DESIGNED) THE GROVE AT LEGACY 192E Organization TSI Energy Solutions Matthew Timmons Builder PYATT BUILDERS, LLC Design Heating Cooling Water Heating SubTotal - Used to determine compliance Lights & Appliances Onsite generation Total Inspection Status Results are projected Annual Energy Cost IECC 2009 Performance $1,185 $171 $329 $1,685 $639 $0 $2,324 Requirements C4405.3 Performance -based compliance passes by 2.5% R402.4.12 Air Leakage Testing C4402.5 Area -weighted average fenestration SHGC 402.5 Area -weighted average fenestration U-Factor 40322 Duct Testing Mandatory Checklist Mandatory code requirements that are not checked by Ekotrope must be met. R4052 Duct Insulation C-M, Energy Solutions As Designed $1,148 $165 $329 $1,642 $623 $0 $2,265 Air sealing is 5.47 ACH at 50 Pa. It must not exceed 7.00 ACH at 50 Pa. Design exceeds requirements for IECC 2009 Performance compliance by 2.5%. As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC orwill be verified as such by another party. Name: Matthew Timmons Organization: TSI Energy Solutions Signature: Date: 913119 at 12:09 PM Ekotrope RATER - Version 3.1.0.2243 IECC 2009 Performance compliance results calculated using Ekotrope RATER's energy and code compliance algorithm. Ekotrope RATER is a RESIN ET Accredited HERS Rating Tool. All results are based on data entered by Ekotrope users. Ekotrope disclaims all liability for the information shown on this report. 7167 ANTIQUITY DR CAR M E L, IN 46033 Builder: PYATT BUILDERS, LLC Ceiling Attic, R-38 Above Grade Walls R-15 Foundation Walls NIA Framed Floor R-30 Slab R-10.0 Perimeter, R-10.0 Under Infiltration 2283 CFM50 (5.47ACH50) Window U-Value: 0.31, SHGC: 0.28 Building Features Duct Supply R-15.0, Return R-10.0 Duct Leakage to Outside 167 CFM25 (6.331100 s.f.) Total Duct Leakage 281 CFM25 (Post -Construction) Heating Furnace • Natural Gas • 92.1 AFUE Cooling Air Conditioner • Electric • 13 SEER Water Heating Water Heater • Electric • 0.93 Energy Factor As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. It rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications. and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and that the mandatory provisions of the I ECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party. Name: Matthew Timmons Organization: TSI Energy Solutions Signature: Date: 913119 at 12:09 PM Ekotrope RATER - Version 3.1.0.2243 20091ECC compliance results calculated using Ekotrope RATER's energy and code compliance algorithm. Ekotrope RATER is a RESIN ETAccredited HERS Rating Tool. All results are based on data entered by Ekotrope users. Ekotrope disclaims all liability for the information sh own on this report. Energy Code Inspection Checklist Property Organization 7167 ANTIQUITY DR TSI Energy Solutions CARMEL, IN 46033 Matthew Timmons Model: GEORGETOWN Community: THE GROVE AT LEGA( Builder PYATT BUILDERS, LLC GL192B (AS DESIGNED) THE GROVE AT LEGACY 192E General Building Information Conditioned Area (sq ft) 2,640 Conditioned Volume (cubic ft) 25,056 Insulated Shell Area (sq ft) 7,553 inspection Status Results are projected C", Energy Solutions The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy features will change in the field from what has been modeled. The inspection process should identify any changes and ensure that the home continues to meet the applicable energy code. Slab Name: SLAB(1,928 s.f., 176 ft. exterior perimeter) R-10 perimeter insulation, R-10 under slab insulation. Framed Floor El Name: AMBIENT (144 s.f.) R-0 continuous insulation, R-30 cavity insulation Insulation Grade: I Foundation Wall None Present Above Grade Wall El Name: CONDIAMB (1,500 s.f.) R-0 continuous insulation, R-15 cavity insulation Insulation Grade: III El Name: CONDIGAR (414 s.f.) R-0 continuous insulation, R-15 cavity insulation Insulation Grade: III Name: CONDIATTIC (769 s.f.) R-0 continuous insulation, R-15 cavity insulation Insulation Grade: III Energy Code Inspection Checklist Property Organization 7167 ANTIQUITY ❑R TSI Energy Solutions CARMEL, IN 46033 Matthew Timmons Model: GEORGETOWN Community: THE GROVE AT LEGA[ Builder PYATT BUILDERS, LLC GL192B (AS DESIGNED) THE GROVE AT LEGACY 192E Name: CONDICOND (603 s.f.) R-0 continuous insulation, R-22 cavity insulation Insulation Grade: III Rim Joist El Name: CONDIAMB (13 s.f.) R: 10.36 Roof Name: CONDIATTIC (110 s.f.) R: 10.36 Name: MAIN (2,072 s.f.) R-27.55 continuous insulation, R-10.15 cavity insulation Insulation Grade: I Opaque Door El Name: FRONT (20 s.f.) U: 0.182 Name: GARAGE (20 s.f.) U: 0.182 Glazing Inspection Status Results are projected E] Name: FRONT (135 s.f.), U: 0.310, SHGC: 0.28, Orientation: WEST E] Name: BACK (59 s.f.), U: 0.310, SHGC: 0.28, Orientation: EAST El Name: LEFT SIDE (116 s.f.), U: 0.310, SHGC: 0.28, Orientation: SOUTH El Name: SLIDER (64 s.f.), U: 0.310, SHGC: 0.28, Orientation: SOUTH Skylight None Present C-M, Energy Solutions 2 Energy Code Inspection Checklist Property Organization 7167 ANTIQUITY ❑R TSI Energy Solutions CARMEL, IN 46033 Matthew Timmons Model: GEORGETaWN Community: THE GROVE AT LEGA( Builder PYATT BUILDERS, LLC GL192B (AS DESIGNED) THE GROVE AT LEGACY 192B Mechanical Ventilation Inspection Status Results are projected Mechanical ventilation system rated for, and capable of, providing continuous ventilation. System shall include automatic timing controls. System type: Exhaust Only, 24 hrslday, 6.5 Watts. Mechanical Equipment 0 Fuel -fired air distribution • Natural Gas • 100% Heating Load @ 92.1 AFUE El Air conditioner • Electric • 100% Cooling Load @ 13 SEER El Water Heating • Electric • 100% Hot Water Load @ 0.93 Energy Factor Air Leakage Control Test Status: Blower -door tested House is air -sealed as to achieve 2,283 CFM50 (5.47 ACH50) or less at final blower -door test. Infiltration Requirements for IECC in Climate Zone 5 2009 IECC Infiltration limit for the design home is 7 ACH50. 2012 IECC Infiltration limit for the design home is 3 ACH50. 2015 IECC Infiltration limit for the design home is 3 ACH50. Duct Leakage Duct System 1 NOT entirely within conditioned space, testing required Leakage to Outside specified as: 167 CFM25 (6.33 J 100 s.f.) Total Leakage specified as: 281 CFM25 (Post -Construction) C-M, Energy Solutions 3 Energy Code Inspection Checklist Property Organization 7167 ANTIQUITY DR TSI Energy Solutions CARMEL, IN 46033 Matthew Timmons Model: GEORGETOWN Community: THE GROVE AT LEGA( Builder PYATT BUILDERS, LLC GL192B (AS DESIGNED) THE GROVE AT LEGACY 192E Duct Leakage Code Requirements for IECC 2009 IECC: Inspection Status Results are projected Postconstruction Leakage Test: Duct Leakage to Outdoors t= 8 CFM25 / 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 6 CFM25 / 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. 2012 IECC and 2015 IECC Prescriptive Path: Postconstruction Leakage Test: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 3 CFM25 / 100 sq ft CFA. 2015 Performance Path (Cost Compliance): C", Energy Solutions Leakage testing is required UNLESS all ducts and air handlers are located entirely within the thermal envelope. There is no pass/fail threshold for duct leakage on the performance path. Project Notes 4 Building Summary Property 7167 ANTIQUITY DR CARMEL, IN 46033 Model: GEORGETOWN Community: THE GROVE AT LEGACY 192B GL192B [AS DESIGNED] THE GROVE AT LEGACY 192E enera?Building Information Number Of Bedrooms Number Of Floors Conditioned Floor Area [sq_ ft.] Unconditioned, attached garage? Conditioned Volume [cu. ft.] Total Units in Building Residence Type Floor Number Model Community Climate Zone Foundation Wall Foundation Wall Library List Slab Organization Inspection Status TSI Energy Solutions Results are projected Matthew Timmons Builder PYATT BUILDERS, LLC 3 2 2;640 Yes 25;056 1 Duplex, single unit GEORGETOWN THE GROVE AT LEGACY 192B 5A None Present None Present Masonry Area C-M, Energy Solutions n SLAB R-10, 1'down, 2' in 176 On Grade 1.23 0 1:928.0 TO Exposed Exterior Conditioned Space Slab Library List Name Wall Construction Slab Completel Underslab Perimeter Perimeter Thermal Break Effective R-value Type Insulated. Insulation Width [ft] Insulation Depth [ft] Insulation R Value R-10, 1'down, 2' in Wood Frame /Other No 2 1 10 No 10.00 1 Building Summary Property Organization 7167 ANTIQUITY DR TSI Energy Solutions CARMEL, IN 46033 Matthew Timmons Model: GEORGETOWN Community: THE GROVE AT LEGACY 192B Builder PYATT BUILDERS, LLC GL192B [AS DESIGNED] THE GROVE AT LEGACY 192B Name Library Type Ca AMBIENT R-30, GR1 Framed Floor Library List Name Effective R-value R-30, GR1 27.493 Rim Joist Name CONDIAMB CONDIATTIC Rim Joist Library List Name C-M Energy Solutions Inspection Status Results are projected e Surface Area Location 1.23 Above Grade 144.0 fL' Exposed Exterior G3 R-15, OSB 13.0 fF Exposed Exterior G3 R-15, OSB 110.0 fF Attic 10.36 Name Library Type Surface Color Surface Area Location CONDIAMB G3 R-15 BATT, OSB Medium 1.500.0 f[' Exposed Exterior CONDIATTIC G3 R-15 BATT, OSB Medium 769.0 f[' Attic CONDJCOND G3 R-22 DbI. Wall Medium 603.0 f[' Conditioned Space [Adiabatic] CONDIGAR G3 R-15 Gar Walls Medium 414.0 f[' Unconditioned, attached garage 2 Building Summary Property Organization Inspection Status C-MEnergy Solutions 7167 ANTIQUITY DR TSI Energy Solutions Results are projected CARMEL, IN 46033 Matthew Timmons Model: GEORGETOWN Community: THE GROVE AT LEGACY 192B Builder PYATT BUILDERS, LLC GL192B [AS DESIGNED] THE GROVE AT LEGACY 192B RVall-library List Name Effective R-value G3 R-15 BATT, OSB 12293 G3 R-15 Gar Walls 10.683 G3 R-22 Dhl Wall 15.364 Glazing �w Name Library Type Wall Assignment Foundation Wall Overhang Depth Overhang Ft To Overhang Ft To Orientation Surface Area Assignment Top Bottom BACK U-.31, SHGG28 CONDIAMB 0 0 0 East 59.0 fF FRONT 11-.31, SHGG28 CONDIAMB 0 0 0 West 135.0 fts LEFT SIDE 11-.31, SHGG28 CONDIAMB 0 0 0 South 116.0 R2 SLIDER 11-.31, SHGG28 CONDIAMB 0 0 0 South 64.0 fF Glazing Library List Name U-.31, SHGC-28 Skylight Skylight Library List 028 None Present None Present 0.310 9 Building Summary Property Organization 7167 ANTIQUITY DR TSI Energy Solutions CARMEL, IN 46033 Matthew Timmons Model: GEORGETOWN Community: THE GROVE AT LEGACY 192B Builder PYATT BUILDERS, LLC GL192B [AS DESIGNED] THE GROVE AT LEGACY 192B Ppopaque Door "`V����� Name Library Type Wall Assignment Foundation Wall Assignment FRONT Fiberglass/Steel CONDIAMB Door GARAGE Fiberglass/Steel CONDIGAR Door Opaque Door Library List i Name Effective U-factor Fiberglass/Steel Door 0.182 C-M Energy Solutions Inspection Status Results are projected Solar Surface Color Surface Area Location Absorptance 0.9 0.75 Medium 20.0 fr Exposed Exterior 0.9 0.75 Medium 20.0 fr Exposed Exterior Roof Insulation i Name Library Type Attic Exterior Area Clay or Concrete Roof Surface Color Surface Area Location P.f.] Tiles F•,1AIN R-38 Blown, GR1 2,072 No Medium 2,072.0 ff Attic Roof Insulation Library List Name Has Radiant Barrier Effective R-value ?•8 3 :a l No 38268 Whole House Infiltratio Infiltration Measurement Type Shelter Class 2283 CFM at 50 Pa Blower -door tested 4 M Building Summary Property 7167 ANTIQUITY DR CARMEL, IN 46033 Model: GEORGETOWN Community: THE GROVE AT LEGACY 192B GL192B [AS DESIGNED] THE GROVE AT LEGACY 192B Mechanical Ventilation I Ventilation Type Ventilation Rate [fle f Minute] IExhaust Only 30 Lighting Interior Fluorescent Lighting 1X Onsite Generation w 0 Organization TSI Energy Solutions Matthew Timmons Builder PYATT BUILDERS, LLC Onsite Generation Library List None Present Solar Generation None Present Solar Generation Library List per Inspection Status Results are projected C-M, Energy Solutions Jay Fan Watts Runs once every three Energy Recovery Percent hours 24 6.5 Yes crescent ! Exterior LED Lighting % Garage Fluorescent Lighting Lighting 100 100 D Lighting 0 .01 Building Summary Property Organization Inspection Status 7167 ANTIQUITY DR TSI Energy Solutions Results are projected CARMEL, IN 46033 Matthew Timmons Model: GEORGETOWN Community: THE GROVE AT LEGACY 192B Builder PYATT BUILDERS, LLC GL192B [AS DESIGNED] THE GROVE AT LEGACY 192E onditivning�quipme Name Library Type Heating Percent Load Cooling Percent Load Air conditioner 4AC`42P 0% 100% I Fuel -fired air 9125A4a060517 100% 0% distribution IWater Heating RE350` 0% 0% 1 Equipment Type: 4AC*42P w==Pw Fuel Type Electric Distribution Type Forced Air Motor Type PSG (Single Speed) Cooling Efficiency 13 SEER Cooling Capacity [kBtulh] 40 Equipment Type: 9125A48060SI7 Fuel Type Natural Gas Distribution Type Forced Air Motor Type PSG (Single Speed) Heating Efficiency 92.1 AFUE Heating Capacity [kBtulh] 56 Use default EAE No EAE [kWh] 649 Equipment Type: RE350* Fuel Type Electric Distribution Type Hydronic Delivery Hot Water Efficiency 0.93 Energy Factor Tank Capacity (gal.) 50 Hot Water Capacity [kBtulh] 15.4 Recovery Efficiency 0.99 C-M, Energy Solutions r Percent Load Location 0% Conditioned Space ❑ I Conditioned Space 100% Conditioned Space 61 Building Summary Property 7167 ANTIQUITY DR CARMEL, IN 46033 Model: GEORGETOWN Community: THE GROVE AT LEGACY 192B GL192B [AS DESIGNED] THE GROVE AT LEGACY 192B 1butivn System Lion Type Equipment Equipment t Served i Grilles Xct R Value ]uct R Value Xct Area r] ]uct Area [ft2] 5 to Outdoors akage akage Duct Test Conditions fault Flow Rate cation Supply Area Return Area cation Supply Area Return Area cation Supply Area Return Area cation Supply Area Return Area cation Supply Area Return Area cation Supply Area Return Area rCeiling Fan Has Ceiling Fan Cfm Per Watt Organization TSI Energy Solutions Matthew Timmons Builder PYATT BUILDERS, LLC Forced Air Fuel -fired air distribution Air conditioner 2640 2 15 1❑ 712.8 264 167 CFM25 (6.331 100 s.f.) 281 CFM25 Post -Construction Yes Attic (well vented; under insulation) 75 50 Conditioned Space 2❑ 5❑ Attic (well vented) 5 0 Conditioned Space Conditioned Space Conditioned Space No Inspection Status Results are projected C-M, Energy Solutions 7 Building Summary Property 7167 ANTIQUITY DR CARMEL, IN 46033 Model: GEORGETOWN Community: THE GROVE AT LEGACY 192B GL192B [AS DESIGNED] THE GROVE AT LEGACY 192B ater Distribution Water Fixture Type Use Default Hot Water Pipe Length Hot Water Pipe Length [ft] At Least R3 Pipe Insulation? Hot Water Recirculation System? Recirculation System Pipe Loop Length [ft] Drain Water Heat Recovery? Clothes Dryer Fuel Type Cef Field utilization Clothes Washer Label Energy Rating Electric Rate Annual Gas Cost Gas Rate Capacity I met Appliances and Controls Programmable thermostat? Dishwasher Size Dishwasher Efficiency Range/Oven Fuel Convection Oven? Induction Range? Refrigerator Consumption Organization Inspection Status TSI Energy Solutions Results are projected Matthew Timmons Builder PYATT BUILDERS, LLC Standard No 55 No No 20 No Electric Timer Controls ff"W 704 kWh/Year $0.081kWh $23.00 $0.581Therm 2.874 ❑.33053 Yes Standard 270 kWh Natural Gas No No 709 kWh/Year "M � C-M, Energy Solutions ,�