Loading...
HomeMy WebLinkAboutA000.4(c) Copyright 2015 PulteGroup, Inc.1900 Golf Road - Suite 300Schaumburg, Illinois 60173Midwest Zone Office11/14/2014Rick Starkey Single Family ---- Woodside 101/26/2015.203/12/2015.312/15/2015PLAN REVISIONS403/11/2016PCR REVISIONS511/14/2016PLAN REVISIONS612/01/2017PCR REVISIONS... PRODUCT MANAGERINITIAL RELEASEDATE:REV#DATE/DESCRIPTION GARAGE HANDING SHEET PLAN NAME SPECIFICATION LEVEL NPC CHILD NUMBER2312.300.00.CPM NOTE: SCALES NOTED ON DRAWINGS RELATE TO FULL SIZE PLOTS ON 22x34 SHEETS - 11x17 SHEETS REPRESENT 1/2 SCALE PLOTSPLOTTED: December 11, 2017 / Tiffany Perreault / A3-HR3Q 3SB.1.DWG A3-HR3Q 3SB.1Heartland 3Q3 Car Side EntryFront, Side and Rear Elevations, Roof Plan and Ventilation ScheduleSCALE:LEFT ELEVATION1/8" = 1'-0"-SCALE:RIGHT ELEVATION1/8" = 1'-0"-SCALE:REAR ELEVATION1/8" = 1'-0"- SCALE:FRONT ELEVATION1/4" = 1'-0"-SCALE:ROOF PLAN1/8" = 1'-0"- 1210 1210 1210 12101210 12101210 CL-07AD 2.3 \A1;8'-1{\H0.750000x;\S1#8;}" \A1;9'-1{\H0.750000x;\S1#8;}" \A1;7'-2{\H0.750000x;\S7#8;}"\A1;HDR. HGT. TYP. \A1;8'-2{\H0.750000x;\S7#8;}"\A1;HDR. HGT. TYP.\A1;8'-1{\H0.750000x;\S1#8;}"\A1;AT GARAGE\A1;7'-2{\H0.750000x;\S7#8;}"\A1;HDR. HGT. AT GARAGE \A1;2'-2{\H0.750000x;\S7#8;}" ROOF SHINGLES, PER SPEC.6" FASCIA BOARD, PER SPEC. TOP OF PLATE 6" RAKE BOARD, PER SPEC.FRIEZE, PER SPEC. HORIZONTAL SIDING, PER SPEC. FRIEZE, PER SPEC. TOP OF FLOORTOP OF PLATE TOP OF FOUNDATIONTOP OF FLOOR STONE VENEER, PER SPEC.STONE HEADER, PER SPEC. SHAKE SIDING, PER SPEC. 14" SHUTTERS, PER SPEC. STONE HEADER, PER SPEC. ROWLOCK SILL, PER SPEC. 4" TRIM, PER SPEC. FYPON #BKT14x14, OR APPROVED EQUAL 8" TRIM, PER SPEC. BRICK VENEER, PER SPEC. FYPON #LV12x24 OR APPROVED EQUAL WITH \P4" TRIM SURROUND STONE VENEER, PER SPEC.STONE SILL, PER SPEC. ROWLOCK SILL, PER SPEC. \A1;3'-6" \A1;3'-0" \A1;3'-6" OPT.OPT.OPT. \A1;HDR. HGT. AT GARAGE 128 128 \A1;2'-2{\H0.750000x;\S7#8;}"123.5 6" TRIM, PER SPEC8" TRIM, PER SPECOPT. MASONRY WAINSCOT OPT. MASONRY FIRST FLOOR \A1;7'-6{\H0.750000x;\S5#8;}"\A1;HDR. HGT. @\PBATH 2OPT.\A1;7'-6{\H0.750000x;\S5#8;}"\A1;HDR. HGT. @\PBATH 2 OPT.OPT. OPT. \A1;9'-1{\H0.750000x;\S1#8;}" \A1;8'-1{\H0.750000x;\S1#8;}" \A1;8'-2{\H0.750000x;\S7#8;}"\A1;HDR. HGT. TYP. \A1;7'-2{\H0.750000x;\S7#8;}"\A1;HDR. HGT. TYP. 128 124 127 123.5 TOP OF FOUNDATION TOP OF PLATE TOP OF PLATE ROOF SHINGLES, PER SPEC. 6" FASCIA BOARD, PER SPEC. 6" CORNER BOARD, \PPER SPEC. HORIZONTAL SIDING, PER SPEC.OPT. MASONRY WAINSCOT OPT. MASONRY FIRST FLOOR \A1;HDR. HGT. @\PBATH 2 \A1;14'-5{\H0.750000x;\S1#8;}"\PAT GATHERING\A1;9'-1{\H0.750000x;\S1#8;}"\A1;8'-2{\H0.750000x;\S7#8;}"\A1;HDR. HGT. TYP. \A1;8'-1{\H0.750000x;\S1#8;}"\A1;7'-2{\H0.750000x;\S7#8;}"\A1;HDR. HGT. TYP. TOP OF FOUNDATIONTOP OF FLOOR TOP OF PLATETOP OF FLOOR TOP OF PLATE MASONRY WAINSCOT HORIZONTAL SIDING, PER SPEC MASONRY FIRST FLOOR OPT. DECK, PER SPEC 1210 126126 1210 \A1;1'-0"\PTYP. \A1;1'-0"\PTYP. \A1;1'-0"\PTYP. "B"561ROOF AREA:SQ. FT. \A1;7'-0" \A1;1'-0"\PTYP. 10:12 10:12 \A1;1'-0"\PTYP. \A1;1'-0"\PTYP. \A1;1'-0"\PTYP. 8:12 8:12 3.5:12 3.5:12 10:12 10:12 7:12 PROVIDE ADEQUATE OPENING FOR AIR MOVEMENT BETWEEN ATTIC SPACES TO SUPPORT REQUIRED VENTILATION \A1;16'-0" \A1;8'-0" OPT. POT VENTS "A"1909ROOF AREA:SQ. FT. MIN. 108 SQ. IN. OF VENTILATION REQUIRED AT EAVE FOR ROOF 10:12 10:12 6:126:12 OPT. POT VENTS \A1;HDR. HGT. TYP. \A1;9'-1{\H0.750000x;\S1#8;}"\A1;8'-2{\H0.750000x;\S7#8;}"\A1;HDR. HGT. TYP. \A1;8'-1{\H0.750000x;\S1#8;}"\A1;7'-2{\H0.750000x;\S7#8;}"\A1;HDR. HGT. TYP. TOP OF FOUNDATIONTOP OF FLOOR TOP OF PLATETOP OF FLOOR TOP OF PLATE SCALE: SIDE AND REAR WINDOW TRIM PER COMMUNITY SPECS1/4" = 1'-0"- VINYL DIMENSIONAL TRIM Heartland 3Q ATTIC VENT SCHEDULE ROOF AREA "A"SQ FTG 1909 AT / NEAR RIDGE AT / NEAR EAVE VENT TYPE SQ. FT. REQUIRED RANGE SQ. FT. SUPPLIED PERCENT OF TOTAL SUPPLIED POT LARGE (SQ. IN. EACH) POT SMALL (SQ. IN. EACH) RIDGE VENT (SQ. IN. PER LF) EAVE VENT (SQ. IN. EACH) CONT. VENT (SQ. IN. PER LF) 61.00 40.00 18.00 28.00 10.00 POT VENTS ONLY 2.55 3.18 2.97 46.06 7 0 AT EAVE 3.82 3.18 3.47 53.94 0 50.00 TOTAL (MIN)6.36 6.36 6.44 100.00 RIDGE VENT 2.55 3.18 3.00 46.35 0 0 24.00 AT EAVE 3.82 3.18 3.47 53.65 0 50.00 TOTAL (MIN)6.36 6.36 6.47 100.00 ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE{\Fromans|c0;VENTILATION REQUIRED AND SUPPLIED IS BASED ON POT VENT VALUES AND RIDGE VENT VALUES SHOWN IN TABLE ABOVE\P** CONTRACTORS INSTALLING VENTILATION ARE RESPONSIBLE FOR VERIFYING THAT VENTS USED WILL SUPPY VENTILATION TO MEET CODE REQUIREMENTS\P* SCHEDULE HAS BEEN CALCULATED ASSUMING EAVE VENTILATION AT 50-60% OF TOTAL AND RIDGE AT 40-50% OF TOTAL REQUIRED VENTILATION} ROOF AREA "B"SQ FTG 561 AT / NEAR RIDGE AT / NEAR EAVE VENT TYPE SQ. FT. REQUIRED RANGE SQ. FT. SUPPLIED PERCENT OF TOTAL SUPPLIED POT LARGE (SQ. IN. EACH) POT SMALL (SQ. IN. EACH) RIDGE VENT (SQ. IN. PER LF) EAVE VENT (SQ. IN. EACH) CONT. VENT (SQ. IN. PER LF) 61.00 40.00 18.00 28.00 10.00 POT VENTS ONLY 0.75 0.94 0.85 44.85 2 0 AT EAVE 1.12 0.94 1.04 55.15 0 15.00 TOTAL (MIN)1.87 1.87 1.89 100.00 RIDGE VENT 0.75 0.94 0.88 45.65 0 0 7.00 AT EAVE 1.12 0.94 1.04 54.35 0 15.00 TOTAL (MIN)1.87 1.87 1.92 100.00 ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE 09/09/19 William Hohlt