HomeMy WebLinkAboutE101.01900 Golf Road - Suite 300Schaumburg, Illinois 60173Midwest Zone Office101-26-2015.23-12-2015.312-15-2015PLAN REVISIONS403-11-2016PCR REVISIONS511-14-2016Plan Revisions............
PLAN NAME
SHEET
PRODUCTION MANAGER
DATE / DESCRIPTION
NPC PLAN NUMBERLAWSON PLAN ID
GARAGE HANDING
REV #
NOTE: SCALES NOTED ON DRAWINGS RELATE TO FULL SIZE PLOTS ON 22x34 SHEETS - 11x17 SHEETS REPRESENT 1/2 SCALE PLOTS
INITIAL RELEASE DATE:CURRENT RELEASE DATE:
(c) Copyright Pulte Home Corporation - 2016
Rick Starkey11-14-2014
LEFT
WOODSIDE
2312.300.00.CPM
--
03-11-2016
PLOTTED: December 5, 2016 / Annie Ki / 2312-WOODSIDE-CZ-BASE-UTIL.DWG
U1
4-1.20First Floor Utility Plan - Options4" Exterior WallsOPT.\PWATER LINE+44"GFI
GFI+44"
GFI+44"
SDISPDW
R
GFI
GFI
\A1;4'-0"
R
R
R
\A1;6'-7"
R
R
R
\A1;5'-10"
\A1;5'-10"
\A1;2'-0"
220VOPT. GAS VALVE+68" FOR \PHOOD
GFI+44"
SCALE:BUILT IN KITCHEN OPTION1/4" = 1'-0"SEE BASE PLANS FOR INFORMATION NOT SHOWN SCALE:BUILT IN KITCHEN 2 OPTION1/4" = 1'-0"SEE BASE PLANS FOR INFORMATION NOT SHOWN SCALE:BUILT IN KITCHEN 3 OPTION1/4" = 1'-0"SEE BASE PLANS FOR INFORMATION NOT SHOWN SCALE:
CABINET ISLAND DESIGNER STYLE
OPTION1/4" = 1'-0"SEE BASE PLANS FOR INFORMATION NOT SHOWN
SCALE:BEDROOM 6 w/BATH 6 OPTION1/4" = 1'-0"SEE BASE PLANS FOR INFORMATION NOT SHOWN SCALE:BATH 6 w/SHOWER OPTION1/4" = 1'-0"SEE BASE PLANS FOR INFORMATION NOT SHOWN
FAN-EXHAUST
GFI
SS
GFI
SSFAN-EXHAUST
SS
220VOPT. GAS VALVE+68" FOR \PHOOD
OPT.\PWATER LINE+44"GFI OPT.\PWATER LINE+44"GFI
SDISPDWGFI
GFI
SDISPDWGFI
GFI
R R
GFI+44"
GFI+44"
GFI+44"
GFI
\A1;4'-0"
R
R
R
\A1;6'-7"
R
R
R
\A1;5'-10"
\A1;5'-10"
\A1;2'-0"
GFI
\A1;4'-0"
R
R
R
\A1;6'-7"
R
R
R
\A1;5'-10"
\A1;5'-10"
\A1;2'-0"
GFI
GFI+68" FOR \PMICRO220V +68" FOR \PMICRO220V
+68" FOR \PMICROGFI+44"
GFI+44"
220VOPT. GAS VALVE+68" FOR \PHOOD
GFI
220V
+44"
BEDROOM 6
BATH 6 BATH 6S/C
S
FLEXFLEX
TO SWITCH TO SWITCH TO SWITCH
SCALE:DOOR OPTION AT FLEX1/4" = 1'-0"SEE BASE PLANS FOR INFORMATION NOT SHOWN
UTILITY LEGEND
SYMBOL SYMBOL TYPE ADDITIONAL NOITES
ADDRESS SIGN ADDRESS SIGN - VISIBLE FROM STREET. LETTERS OR NUMBERS FOR THE ADDRESS SHALL BE 4" MIN. IN HEIGHT AND 0.5" MIN. IN STROKE OF A CONTRASTING COLOR TO THE BACKGROUND ITSELF
CHIMES - DOORBELLDETECTOR - HEATCEILING MOUNTED HEAT DETECTOR TO BE HARD WIRED TO FIRE ALARM SYSTEM (INSTALL PER CODE)
DETECTOR - SMOKE/CARBON MONOXIDE COMBINATIONUL APPROVED CEILING MOUNTED SMOKE /CO DETECTOR TO BE HARD WIRED WITH BATTERY BACK-UP (INSTALL PER CODE)
DETECTOR - CARBON MONOXIDE UL APPROVED CEILING MOUNTED CO DETECTOR TO BE HARD WIRED WITH BATTERY BACK-UP (INSTALL PER CODE)
DETECTOR - SMOKE UL APPROVED CEILING MOUNTED SMOKE DETECTOR TO BE HARD WIRED WITH BATTERY BACK-UP (INSTALL PER CODE)
DISCONNECT - SWITCHEDFAN - CEILING W/ LIGHTFAN BOX PER CODE. PROVIDE 4-WIRE CABLE FROM SWITCH(ES) (CLG FAN OPTIONAL)
FAN - EXHAUSTEXHAUST TO EXTERIORFAN - EXHAUST W/ LIGHTEXHAUST TO EXTERIORLIGHT - CEILINGLIGHT - CEILING-PULL CHAINLIGHT - FLUORESCENT-48X9LIGHT - FLUORESCENT-UNDER CAB-14
LIGHT - RECESSEDLIGHT - RECESSED-VAPOR PROOFLIGHT - WALLLIGHT - WALL-PULL CHAINMETER - ELECTRICVERIFY LOCATION IN FIELDOUTLET - 220VOUTLET - DISHWASHEROUTLET - DUPLEXOUTLET - DUPLEX-SPLIT WIREDOUTLET - FLOOROUTLET - GFIOUTLET - GARAGE DOOROUTLET - PHONE CAT 5EOUTLET - TVRG-6OUTLET - WATERPROOF-GFIPANEL - ELECTRICVERIFY LOCATION IN FIELDSWITCH - DISPOSALSWITCH - LIGHTSWITCH - THREE WAYSWITCH - FOUR WAYSWITCH - PUSH BUTTONTHERMOSTATTHERMOSTAT SHALL BE PROGRAMMABLEHOSE BIBBWATER SERVICEGAS VALVEGAS METERRETURN AIR GRILLEWATER METER
HS/C
C
S
PC
14RV
PCE220VDW
GFIGFI
PHTVWP/GFI
SDISPS3SS4
THBOPT.\PWATER LINE
GAS VALVEGR.A.G.W
09/09/19
William Hohlt