HomeMy WebLinkAbout217JGB - Sewer Permit10701 N. College Avenue Suite A Indianapolis, Indiana 46280 phone 3174344-9200 fax 3174344-9203 www.tnca.eco
Residential
SANITARY SEWER PERMIT
999913381
Permit Type
Final
Subdivision
Jacksons Grant
Project WO
2017-1339
Section Number
4
Project Name
Jacksons Grant Section 4
Lot Number
217
Project Developer
Jackson's Grant Real Estate Company
Address Number
12217
Lift Station
26 Jacksons Grant
Address 2
Treatment Plant
MIX
Street
Hobby Horse Drive
Parcel Acreage
0.22
City
Carmel
EDU in Gallons
310
Zip Code
46032
County
Hamilton
Local Sewer Charge-
District Contribution 0.00
Builder
Wedgewood Building Company
Plan Review and Inspection 0.00
- --
Application Fee
150.00
Phone Number
317-669-6315
EDU Fee
1908.00
Owner
Interceptor Fee
0.00
Phone Number
Other Fees
0.00
Fees Due
2058.00
Occupant
Invoice Number
Phone Number
PLEASE NOTE: Installation of building sewer shall be per the specifications of the TriCo Regional Sewer Utility (see
reverse) and any Conditions noted below. All installations shall be inspected by TrCo personnel during "open trench"
phase and before backflling with stone to twelve inches above the pipe. NO footing or foundation drains, or other
sources of ground or stormwater, shall be permitted to enter TriCo's sanitary sewer system. TriCo will assume no
liability for drains which are below the grade level of the nearest downstream manhole nor for laterals which are
extended beneath driveways or sidewalks. The permit holder (property owner, developer or builder) will be
responsible for damages to TriCo's sewer system. This includes damages to manholes, castings, manhole lids and
the like; caused by construction activity on the building site which is the subject of this permit.
Inspections by T r Co are MANDATORY and shall be arranged by contacting TnCo's office at 844-9200 24 hours in
advance. All new construction will be placed on billing two months after connection has been made or when water is
connected, whichever comes first.
The building has: Maln ID: JG874JG875
Grease Trap Slab Foundation usnH
Grease Interceptor Crawl Space Manhole Os JG-874 JG-875 DSMH
Grit Interceptor Basement YES Lid Elevation 862.3Vj 861.59
Grinder Station First Floor Elevation 864.80 V/ 864.80 ✓ /
Water Service Carmel Utilities Basement Elevation 854.80s/ 854.80 ✓
Calculation is based on bath Manhole Lid Elevah'ons and the elevation ofthe First Floor 2.49 3.21 Ft.
Per Ordinance 9-13-99 and the elevations provided, the substructure shall be plumbed by: Ejector Pump Only
TnCo currently requires that an I&I inspection is performed and a Certificate of Compliance is issued prior to occupancy /
sale of a properny. Please review attached 1/1 Permit.
Manholes shall remain accessible at all times. Buried manholes will be corrected by the Developer/Owner.
The proper Gass of cleanout must be installed every 100 feet of lateral pipe measured from sewer main to structure.
The terms of the conditional permit, if any, are listed below
_ No manhole core permit required.
The facility is not classified as a FOG facility.
By signing below. I attest Nat 1 strife it th the 0� 'd's s e eons and agree to accept mi
Builder / Owner Signature Phone
Printed Name t " n
Approved By
Permit is valid for ONE-YEAR from the date issued. Permit valid only with TnCo
T r i C o
pennit.
_Qkso
SUMMARY OF LATERAL INSTALLATION REQUIREMENTS
1. Only one building may connect to the sewer main per lateral unless otherwise approved by TrOo.
2. Foundation drains, sump drains, downspouts and other stone water drains shall never be connected to the sanitary sewer.
Site dewatering systems shall never be discharged to the sanitary sewer.
3. The existing sewer line from the building to the septic tank may only be reused if it is located under a building addition, patio,
porch or paved driveway, and the line passes an air test that is observed by TnCc. Contact TrOo for more information about
air testing requirements. The property owner is responsible for testing costs.
4. TriCo shall inspect all new laterals or lateral repairs in their entirety. Final connection to the sanitary sewer must be observed
by Trim. The property owner or contractor must notify TnCo prior to backfilling. Inspections must be scheduled at least 24
hours in advance. If an inspection fails and subsequent inspections are required, or if the contractor is not on site for the
scheduled inspection, a $100 fee will be assessed and must be paid prior to scheduling the reinspection.
5. Septic system contents or effluent shall never be discharged to the sanitary sewer. Be advised that your county health
department regulates septic systems. Upon connection to sanitary sewer, a septic tank must typically be abandoned,
pumped clean, and filled completely with earthen material. Contact your county health department for more information on
septic system and abandonment requirements, and to notify the department of any abandonment.
6. The following materials are acceptable for use in gravity sewer lateral installation or repair:
PVC pipe: SDR 35 or SDR 26, ASTM D3034, 6' diameter
PVC pipe, pressure rated: SDR 21, ASTM D2241, 6' diameter
PVC restrained joint pipe for directional drilling: Certaflo Greenline SDR 21, ASTM D2241, 6" diameter
All gasketed joints shall meet ASTM D3212
All fittings shall be SDR26 or better
Ductile iron mechanical joint fittings with proper hardware
SDR 26 gasketed repair sleeves or Indiana Seal shear guard
Femco and similar flexible couplings are only acceptable in certain circumstances and shall not be used without
prior approval from TriCo
Cleanouts: 6'threaded PVC caps
Bedding: Use #8 crushed stone or fractured face aggregate
The following materials are acceptable for use in low-pressure sewer lateral installation or repair:
HDPE pipe for directional drilling: DR 11 IPS, 1.25' diameter, PE4710
Connections shall be made via electrofusion or using polypropylene or stainless steel compression fittings
Electrofusion high volume tapping tee, rated 200 psi, PE4710
1.25" IPS full port 1/4 turn fusible PE ball valve, rated 200 psi
Threaded swing check valve, 316 stainless steel, rated 200 psi
Contact TnCo for acceptable pump station materials, equipment, pumps and other requirements
7. For gravity and low-pressure systems, the line leaving the building shall not exceed 3' in length before a cleanout must be
added and the line is transitioned to 6` diameter SDR 35 PVC pipe. Glued joints are not allowed after 3'. No additional glued
fittings are allowed between the building and the transition/cleanout. For all gmvfty lines, cleanouts shall not be spaced more
than 100' apart between the building and the sewer main. See TriCo's standard drawings for more information on cleanout
installation.
8. Bedding material shall be placed from at least 6 inches below to 12 inches above the pipe surface. The trench shall be a
minimum of 18" wide with at least 6' of clearance on bath sides of the pipe. Material shall be placed over the pipe and tracer
wire after inspection. Soft, unstable or unsuitable material found below and near the lateral, including any fill or foundation
backfill material, must be removed and replaced with #8 stone. The contractor is solely responsible for establishing stable
pipe bedding conditions.
9. #16AWG solid copper tracer wire shall be laid on lop of and run the entire length of the lateral. All splicing of tracer wire
shall use 3M splice kit model DBR/Y5, King Innovation Dryconn Direct Bury Lug Aqua catalog #90220, or TnC0 approved
10, Laterals shall be installed at least 20' from water wells unless PVC pressure grade pipe is used. Any proposed installation
requiring pressure pipe shall be reviewed by TriCo prior to installation. Where a transition is made between SDR 35 pipe and
pressure grade SUR 21 pipe, a ductile iron gasketed mechanical couplings must be used.
11. Laterals less than 5' deep shall be at least 24' from the property line. Laterals mare than Steep shall be at least 36' from
the property line. Where the lateral runs in close proximity to the property line the properly corners must be accurately
staked by a professional land surveyor prior to inspection.
12. Laterals running parallel to a building or structure shall be at least 36' from the face of a crawl space or slab on grade
foundation and 60" from the face of a basement foundation wall. Spacing requirements also apply with respect to the
ancillary structure's foundation depth. Ancillary structures (e.g. window wells) and other utilities shall not be placed over or
near the lateral. TdCo may adjust requirements where future access to the lateral may be obstructed by other utilities. The
contractor should call to discuss further if he/she believes this could be an issue.
13. All infrastructure connected to TnCo's sewer system may be tested, inspected, or televised at TnCo's discretion, and must
remain accessible and properly maintained.
14. Call 811 or 1-800-3825544 before you dig. For more information go to www. indiana811.org.
TriCo Regional Sewer Utility
10701 North College Avenue Suite A
Indianapolis, Indiana 46280
Phone(317)-844-9200 Fax(317)-844-9203
Revised 031IM019
TriCo Regional Sewer Utility
I u r U IN, college Avenue bUte A
mosmapolls, Ind Tana 46280
phone 317-844-9200 fax 317-8449203 wow. mw.eco
Residential
I & i Permit
Ordinance 12-08-08
Lateral Location
Owner/ Occupant Information
Address Number
12217
Owner
Address 2
First Name
Street
Hobby Horse Drive
Last Name
-
City
Carmel
phone Number
State
IN
Mobile Number
Zip Code
46032
_
Fax Number
Subdivision
Jackson Grant
Email Address
Section Number
4
Lot Number
217
Permit Information
Owner Address if Different
Address Number
Address 2
Street
City
State
Zip Code
Builder Information
Builder Wedgewood Building Company
Phone Number
317-569-6315
Facility Features and Addition Information
Slab Foundation
Square Footage
Crawl Space
Water Type
Cannel Utilifies
Basement
YES
Basement Status
Ejector Pump Only
Cleanout
YES
Main ID
JG874-JG875
Ejector Pump
YES
Lift Station
26 Jacksons Grant
Sump Pump
YES
Grinder Station
Program Specifications
a This program requires prior to the sale/occupance of a property that the property owner/builder notify TriCo and
schedule an inspection. The inspection will verify that:
e Downspouts are not connected to the sanitary sewer
a The sump pump is not connected to the sanitary sewer
e Cleanout caps are in place and watertight
e No yard drains are connected to the sanitary sewer
e There are no sinkholes or other indications that the sewer lateral is leaking
e 5 Ton or greater HVAC units do not dishcarge condenstion to the sanitary sewer.
• If deficiencies are found, the property owner will be notified and must make corrections immediately. The property
owner will need to schedule a follow up inspection. If a certificate of compliance is not issued within 30 days of the
change in ownership, K a se surcharge �Il"n,'per month will be assessed and added to the sewer bill.
Owner/ Occupant Signatu \ 'U,u��ri. Date: �I' C, k� C'
Approved BY: > Date- 19 %�7nICr
e
'19AUG 27PN3:18
JACKSON'S GRANT P LOT PLAN
I N WILLIAMS CREEK n
NST./2018-009549 II N
LOT #217 — SECTION 4 PREPARED FOR
CITY OF CARMEL, INDIANA WEDGEWOOD BUILDING COMPANY
12217 HOBBY HORSE DRIVE
LOT SIZE:
9.507 SO.FT.
CONC. DRIVEWAY:
1,0583 SO.FT.
PUBLIC WALK:
340t SO.FT.
PRIVATE WALK:
03 SO.FT.
SEEDING:
2.5103 SOFT.
SOD:
344t SO.YD.
—E7 a.. z NOTE,
- THE L CTIO TO CONFORM N1TX W OF CARMEL STANDARDS
- 0 LOCATONS DIMENSION; AND ITOTN ALONG THE PROPOSED Y Ol-I NS ON A HERE SCALED
OR TAKEN FROM FNdNEQONG CONSTRUCTION PLANS PREPMED BY OT1ER5 dt AS PNONDED.
- VERIFY SANITARY LATERAL LOCATION PRIM TO CONSTRUCTCN
- IT SHLL BMI ABE THE RESPONSIBUTY OF T DFA/CONTRACTOR TO VERFY THE BUILDING
000.0 — PROPOSED GRADE dME49ON% BUILDING LOCATIONS. THE LOCATION OF OTHER PERTNEHT FEATURES AND
ELEVATIONS PRIOR TO THE START OF CONSTRUCTGN. THE INTENDED VSE OF THIS PLOT PUN IS
000.0 — EXISTING GRADE FOR SECURING SUIMNC PERMITS ONLY AND SHALL NOT BE USED FOR ANY OTHER PURPOSE
LAND DEVELOPMLN ICONSULTING ORMN: TAT DAIS 08/19/19 SCALE 1' m 50'
�1RL Q LANDSURVEYINGSERVICES JOB0 19-578 REV.: ➢B/27/19
L /�IJL I1650OIWRob.SuimPl000.289 ZONED: BRIDGEMONT F.F.E. HSE: 864.8'
Fishers, Indism a603]
NORTH elmxe:(317"41-R75a ZONING: 5'/10' SIDE F.F.E. GAR: 863.5'
wixnxu vuu lx TnE4mrtaaeaTArr F—(SI7"41-atta F.F.E. BSM'T: 854.8'
B-mil: �y@Tm=oMindy.com 20' REAR