HomeMy WebLinkAbout215JGB - Sewer PermitAvenue Suite A
IKesiaeriyaf SANITARY SEWER PERMIT 999913392
Permit Type
Final
Subdivision
Project WO
2017-1339
Section Number
Project Name
Jacksons Grant Section 4
Lot Number
Project Developer
Jackson's Grant Real Estate Company
Address Number
Lift Station
26 Jacksons Grant
Address 2
Treatment Plant
MIX
Street
Parcel Acreage
0.22
City
EDU in Gallons
310
Zip Code
County
Local Sewer Charge - District Contribution
Plan Review and Inspection
Application Fee
EDU Fee
Interceptor Fee
Other Fees
Fees Due
Invoice Number
0.00 Builder
0.00
150.00 Phone Number
1908.00 Owner
0.00 Phone Number
0.00
2068.00 Occupant
Phone Number
4
215
19999
Hobby Horse Drive
Cannel
46032
Hamilton
Wedgewood Building Company
317-669-6315
rL OM NU i C: insianauon oT oonaing sewer snau oe per the specincations otme 1 nGo Negional Sewer Utility (see
reverse) and any conditions noted below. All installations shall be inspected by TriCo personnel during "open trench"
phase and before backflling with stone to twelve inches above the pipe. NO footing or foundation drains, or other
sources of ground or stormwater, shall be permitted to enter ThCo's sanitary sewer system. TriCo will assume no
liability for drains which are below the grade level of the nearest downstream manhole nor for laterals which are
extended beneath driveways or sidewalks. The permit holder (property owner, developer or builder) will be
responsible for damages to TriCo's sewer system. This includes damages to manholes, castings, manhole lids and
the like; caused by construction activity on the building site which is the subject of this permit.
Inspections by TriCo are MANDATORY and shall be arranged by contacting TriCo's office at 844-920024 hours in
advance. All new construction will be placed on billing two months after connection has been made or when water is
connected, whichever comes first.
The building has: Main ID: JG856JG867
Grease Trap Slab Foundation
Grease Interceptor Crawl Space Manhole IDS USMH JG-856 JG-857—DSSMMH—
Grit Interceptor Basement YES Lid Elevation 861.76✓861.88J
Grinder Station First Floor Elevation 864.70✓// / / 864.70�
Water Service City of Cannel Basement Elevation 854.70 J 854.70 ✓
Caloulalion is based on both Manhole Lid Elevations and me elevation o/the First Flow _ 2.94 2.82 Ft.
Per Ordinance 9-13-99 and the elevations provided, the substructure shall be plumbed by: Ejector Pump Only
P« TnCo currently requires that an I&I inspection is performed and a Certificate of Compliance is issued prior to occupancy /
sale of a property. Please review attached 1/1 Permit
TA Manholes shall remain accessible at all times. Buried manholes will be corrected by the Developer/Owner.
%C a The proper class of cleanout must be installed every 100 feet of lateral pipe measured from sewer main to structure
The terms of the conditional permit, if any, are listed below. `GOAL asty
Plans have been submitted,
eo a9�
All fees have been paid. o �A
No certificate of insurance required. tf t
_ No additional permits required.
TriCo
_ No manhole core permit required.
The facility is not classified as a FOG facility.
8
(Notes)
¢'
HONE-M1MRy nM
,mvnyccw1—. LceMuusu,IllY lur all m m none uneer due permit.
Builder/Owner Signature Phone Number 31,7 G69
t7 G31�
Printed Name f A v l A j`•r,pi%—
Approved By
Rv.6NEAR
c, 'lEnpnes, 09/05/2019
Permit is valid fo from Ne date i.sued. PertnR valitl only with TriCo seal in red ink.
SUMMARY OF LATERAL INSTALLATION REQUIREMENTS
1. Only one building may conned to the sewer main per lateral unless otherwise approved by TnCo.
2. Foundation drains, sump drains, downspouts and other storm water drains shall never be connected to the sanitary sewer.
Site dewatenng systems shall never be discharged to the sanitary sewer.
3. The existing sewer line from the building to the septic tank may only be reused if it is located under a building addition, patio,
porch or paved driveway, and the line passes an air test that is observed by TnCc. Contact TriCo for more information about
air testing requirements. The property owner is responsible for testing costs.
4. TnCo shall inspect all new laterals or lateral repairs in their entirety. Final connection to the sanitary sewer must be observed
by Trico. The property owner or contractor must notify TnCc prior to backfilling. Inspections must be scheduled at least 24
hours in advance. If an inspection fails and subsequent inspections are required, or if the contractor is not on site for the
scheduled inspection, a $100 fee will be assessed and must be paid prior to scheduling the reinspection.
5. Septic system contents or effluent shall never be discharged to the sanitary sewer. Be advised that your county health
department regulates septic systems. Upon connection to sanitary sewer, a septic tank must typically be abandoned,
pumped clean, and filled completely with earthen material. Contact your county health department for more information on
septic system and abandonment requirements, and to notify the department of any abandonment
6. The following materials are acceptable for use in gravity sewer lateral installation or repair.
PVC pipe: SDR 35 or SDR 26, ASTM D3034, 6' diameter
PVC pipe, pressure rated: SDR 21, ASTM =41, 6' diameter
PVC restrained joint pipe for directional drilling: Certafto Greenline SDR 21, ASTM D2241, 6' diameter
All gasketed joints shall meet ASTM D3212
All fittings shall be SDR26 or better
Ductile iron mechanics] joint fittings with proper hardware
SDR 26 gasketed repair sleeves or Indiana Seal shear guard
Femw and similar flexible couplings are only acceptable in certain circumstances and shall not be used without
prior approval from TnCo
Cleanouts: 6' threaded PVC caps
Bedding: Use #8 crushed stone or fractured face aggregate
The following materials are acceptable for use in low-pressure sewer lateral installation or repair.
HDPE pipe for directional drilling: DR 11 IPS, 1.25' diameter, PE4710
Connections shall be made via electrofusion or using polypropylene or stainless steel compression fittings
Electrofusion high volume tapping tee, rated 200 psi, PE4710
1.25' IPS full port 114 turn fusible PE ball valve, rated 200 psi
Threaded swing check valve, 316 stainless steel, rated 200 psi
Contact TnCo for acceptable pump station materials, equipment, pumps and other requirements
7. For gravity and low-pressure systems, the line leaving the building shall not exceed 3' in length before a deanout must be
added and the line is transitioned to 6' diameter SDR 35 PVC pipe. Glued joints are not allowed after 3'. No additional glued
fittings are allowed between the building and the transition/deanout For all gravity lines, deanouts shall not be spaced more
than 100' apart between the building and the sewer main. See TnCo's standard drawings for more information on deanout
installation.
8. Bedding material shall be placed train at least 6 inches below to 12 inches above the pipe surface. The trench shall be a
minimum of 1 B' wide with at least 6° of clearance on both sides of the pipe. Material shall be placed over the pipe and tracer
wire after inspection. Soft, unstable or unsuitable material found below and near the lateral, including any fill or foundation
backfill material, must be removed and replaced with #8 stone. The contractor is solely responsible for establishing stable
pipe bedding conditions.
9. #10-AWG solid copper tracer wire shall be laid on top of and run the entire length of the lateral. All splicing of tracer wire
shall use 31y splice kit model DBRN-6, king Innovation Dryconn Direct Bury Lug Aqua catalog #90220, or TnCo approved
10. Laterals shall be installed at least 20' from water wells unless PVC pressure grade pipe is used. Any proposed installation
requiring pressure pipe shall be reviewed by Tr Co prior to installation. Where a transition is made between SDR 35 pipe and
pressure grade SDR 21 pipe, a ductile iron gasketed mechanical couplings must be used.
11. Laterals less than 5' deep shall be at least 24' from the property line. Laterals more than 5' deep shall be at least 36' from
the property line. Where the lateral runs in close proximity to the property line the property comers must be accurately
staked by a professional land surveyor prior to inspection.
12. Laterals running parallel to a building or structure shall be at least 36' from the face of a crawl space or slab on grade
foundation and 60' from the face of a basement foundation wall. Spacing requirements also apply with respect to the
ancillary structure's foundation depth. Ancillary structures (e.g. window wells) and other utilities shall not be placed over or
near the lateral. TnCo may adjust requirements where future access to the lateral may be obstructed by other utilities. The
contractor should call to discuss further if he/she believes this could be an issue.
13. All infrastructure connected to TdCo's sewer system maybe tested, inspected, or televised at TdCo's discretion, and must
remain accessible and property maintained.
14. Call 811 or 1-800382-5544 before you dig. For more information go to www.indiana811.org.
TnCo Regional Sewer Utility
10701 North College Avenue Suite A
Indianapolis, Indiana 46280
Phone (317)-844-9200 Fax (317)4844-9203
Revised 03/1912019
TriCo Regional Sewer Utility
10701 N. College Avenue Suite A
Indianapolis, Indiana 46280
phone 317-844-9200 fax 317-844-9203 www.tdco.eco
Residential
1 & 1 Permit Ordinance 12-08-08
Lateral Location
Owner/Occupant Information
Address Number
12229
Owner
Address 2
First Name
Street
Hobby Home DrYs
Last Name
City
Carmel
Phone Number
State
IN
Mobile Number
Zip Code
40032
Fax Number
Subdivision
Jacksons Grant
Email Address
Section Number
4
Lot Number
215
Permit Information
Owner Address if Different
Address Number
Address2
Street
City
State
Zip Code
Builder Information
Builder
Wedgewood Building Company
Phone Number
317-669-6315
Facility Features and Addition Information
Slab Foundation
Square Footage
Crawl Space _
Water Type
City of Cannel
Basement
YES
Basement Status
Ejector Pump Only
Cleanoul
YES
Main lD
JG856-JG857
Ejector Pump
YES
LIB Station
26 Jacksons Grant
Sump Pump
YES
Grinder Station
• This program requires prior to the sale/occupance of a property that the property owner/builder notify TdCo and
schedule an inspection. The inspection will verify that:
• Downspouts are not connected to the sanitary sewer
• The sump pump is not connected to the sanitary sewer
• Cleanout caps are in place and watertight
• No yard drains are connected to the sanitary sewer
• There are no sinkholes or other indications that the sewer lateral is leaking
• 5 Ton or greater HVAC units do not dishcarge condenstion to the sanitary sewer.
• If deficiencies are found, the property owner will be notified and must make corrections immediately. The property
owner will need to schedule a follow up inspection. If a certificate of compliance is not issued within 30 days of the
change in ownership, a sewer surcharge of $20 er month will be assessed and added to the sewer bill.
v / //j
i� 1r
Owner / Occupant Signature: Date:
Approved By: r— Date:
APPROVED
ex W r..eKxn v:ss.x. a.R a, m1v
119SEP 5AN9'00
JACKSON'S GRANT
ON WILLIAMS CREEK
INST.p2018-009549
LOT #215 — SECTION 4
CITY OF CARMEL, INDIANA
12229 HOBBY HORSE DRIVE
LOT SIZE: 9,6DO SO.FT.
CONIC. DRIVEWAY: 1,196t SOFT.
PUBLIC WALK: 334t SO.FT.
PRIVATE WALK: Ot SO.FT.
SEEDING: 2,1853 SO.FT.
SOD: 365t SO.VD.
M PLOT PLAN
II
PREPARED FOR
WEDGEWOOD BUILDING COMPANY
1156
T.C. - 86138'
A. Z_
NOTE-
- DRIVE ENTRY TO CONFORM WN CITY M CARMEL STANDARDS
- NE LOCAnONS. DIMENSIONS, AND WON ALONG THE PROPOSED PUBLIC SDEWALK WRE SCALED
OR TAKEN FROM ENGINEERING CMSTRUCTWN PLANS PREPARED BY OTHERS OR AS PRONDED.
- VERIFY SANITARY LATERAL LOCATON PRIOR TO CONSTRUCTION
- IT SHALL BE THE RESPONSBII3TY OF THE BUILDER/CMIRACTM TO VERIFY NE BUILDING
000.0 — PROPOSED GRADE DDAMSMS. BUILDING LDDATONS. THE ,OCAnON DF ONER PERTINENT FEATURES AND
ELEVATMS PRIM TO THIN START OF CONSTRUrnDN. THE INTENDED USE OF THIS PLDT PLAN IS
000.0 — EXISTING GRADE FOR SECURING BUILDING PERMITS MLY AND SHALL NOT BE USED FOR ANY OTHER PURPOSE
,AND DEVELONALM' CONSULTWG
DAMN: TAT
DATE O9/03/19
SCALE: 1' = 30'
�{��
TRL
A uNDSURVEYINGSERVICES
JBBR 19-621
REV.:
ZONED: BRIDGEMONT
F.F.E. HSE: 864.7'
NORTH
Fnh.I I. 46Bimp1000-389
Fu6m.lndiw a603T
Fu
ZONING: 5'/10' SIDE
F.F.E. GAR: 863.4'
•roltn'Iw Yuu lx Txe Al[NI'WQTKIH'
(317YPi.87RTSa
F il: Tj-0AI RT61
Cw:,: Tmy®TrvmaMiMy.wm
20' REAR
F.F.E. BSM'T: 854.7'