HomeMy WebLinkAbout32 M104 Enlarged HVAC Plans - 1st FloorRELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and Focal Codes
City of Camel
DATE: 09/10/19
O DP-02-M-102MEZZANINE
1/41, = 1'-01,
Mechanical General Notes
A These plans we diagrammatic in netue ant do not represent every rea essayonset
and hiring. Contractor shall install be work in a manner that will ocntorm with the
structure. Contractor shell avoid obstmot'wns, preserve head room and maintain
maximum cbararwe without additional cost to the owner.
B Conceal all IineseW, piping, power wiring, control wiring and control ocmpon ads
unless otherwise noted. lt concealment is not possible, cannot Enginear for
alternatives prior to fabrication.
C Insulate all interior Howell with 1l2" tltic, fiexihie elastomerio insulation. Insureds
exterior Iineseb with 1" thick flexible elastomerio insulation with ederneL02T
aluminum protective decked.
D Sheet meal supply ductwork in concealed spaces shall be insulated with If12"thick
]5 PCF density, fiberglass dudwrap. All ductwork in unecndltiooed spaces shall be
insuated with 2" thick 1.0 PCF density, fiberglass dudwrap. (Min 116)
E Pherglio duct by Pal -Duct or Kool-Duct is an acceptable alternative to sh estmetal
duct and insulation in wnceaked spaces. Use ranged joints
F Keep all ductwork, duct system ard equipment openings covered with adhesive dud
protective wrap like Venturi 1512, until system start up. This is to prevent
irtrusion of construction dirt and debris into the duct system, and HVAC equipment
G If any questions arise concerning the WAD requirements of these documents,
pleased conead The Engineering Collaborative at (317) 636-3941, prior to coal g,
fabncedion or insta iallon of equipment.
H Sheet metal transitions by Sheet Metal Contractor.
J Huffer to Ml sense sheets for afdbnal requirements and information that applies
to this pmjetl.
O DP-01-M-102FLOOR LINE
1 /41,= 1'-01,
Mechanical Plan Notes
Mt
Existing GRID to remain in pace. Rebalance to CFM indicated.
M2
Rebate existbg Gl to new location Rhoabnce to CFM indicated.
M3
Existing Dlsdwork
M4
New GRUD
M5
Provide Sound Boot. See double for more information
M6
Reboots existing T-stat to new location.
Cooler Design
Architecture, Planning and Interior
Design
9135 N. Meridian
Streit
Suite Al
Indianapo4; IN 46360
(n 317.a16.1144
wwwcooterdeslgn.com
PmrwWPoscwru LiwN
MOT7TNFLMNLC® MWPRIcs /NMR/WMIN4�6.
WckAhXAL
MFOLFR(s FCTPMIC WIM]MF IXPWSS WP/r1FNCpI{FM OT
COCYFPOFL6N 4<
C(M4W(IAl9
��
z
........�,.
O
y�2i z
ILL
I—
�1pR
"Ottunnnoo••
U
PLAN
NORTH
/ 1 1
W
N
ca
z
O
o
¢
0
j
cn
O
O
U
a
C
O
¢
O
U
U
to
CCI
Q
2
Z
0
0
O
_O
LL
in
R
I
Z a
N
Q
c>s
O zIII
°C
U
U
Q
L
H
p w
=
%i
a ~
w ~
w
�C
W
a °
z
V
=
W
� an
LLJ
M104
SHEET NO.