HomeMy WebLinkAbout3 D111 1st Floor Mezzanine Demolition PlanLEGEND
wim
EXISTING TO BE REMOVED
---- WALL
xxvxvx PARTIAL HEIGHT WALL
r DOOR AND FRAME
WINDOW/SIDELIGHT
Ji _L CEILING GRID AND
T --T
TILES, 2'x4'
_4—
CEILING GRID AND
TILES, 2'x2'
SUPPLY AIR DIFFUSERS
e_a
eeuo
� —�
EXHAUST FAN
� LIGHT FIXTURE,
�L___ Jj FLUORESCENT, 2'x4'
F�1
LIGHT FIXTURE,
L_J
FLUORESCENT, 2'x2'
.*1
LIGHT FIXTURE, CAN
d==3
WALL SCONCE
•----+
LIGHT FIXTURE,
FLUORESCENT
eye—..—LLi
LIGHT FIXTURE, TRACK
LIGHT FIXTURE,
LIGHT FIXTURE,
shD
PENDANT
sS
LIGHT SWITCH
<Y
EXIT LIGHT
E—]
EMERGENCY LIGHT
�' ELECTRIC OUTLET(S)
'e)'9";I
DATA OR
COMMUNICATION
OUTLET
EXISTING TO REMAIN
WALL
»�
PARTIAL HEIGHT WALL
DOOR AND FRAME
x
WINDOW/SIDELIGHT
NOTE EXISTING FIXTURES THAT ARE REMOVED CAN BE REUSED IF IN
GOOD CONDITION.
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and Local Codes
City of Camel
DATE: 09/10/19
GENERAL NOTES
I. REFER TO ALL DECONSTRUCTION NOTES ON TITLE SHEET TI II.
2. ALL ITEMS BEING REMOVED FROM PROJECT AREA ARE TO BE
CAREFULLY CONSIDERED FOR REUSE IN THE PROJECT OR
BUILDING IF POSSIBLE. FOR ALL ITEMS DETERMINED FOR
REMOVAL, REFER TO THE DECONSTRUCTION MANAGEMENT
CHECKLIST BELOW.
3. REMOVE EXISTING RECEPTACLES AND/OR SWITCHES AS SHOWN
ON PLAN PER LEGEND. PATCH WALL AND PREPARE FOR NEW
FINISHES AS REQUIRED.
PLAN NOTES
D01 REMOVE EXISTING CABINETRY AND COUNTERTOP.
D02 REMOVE EXISTING SINK. NO SERVICE SINKS ARE BEING REMOVED.
REMOVE EXISTING BREAK ROOM SINK AND SALVAGE PLUMBING
D03 LOCATION FOR NEW SINK. SEE AI I I AND A211 FOR MORE
INFORMATION.
REMOVE AND SALVAGE AND RELOCATE SINK AT RESTROOM
1, D04 COUNTERTOP. EXISTING PLUMBING TO REMAIN SEE A I I I FOR
MORE INFORMATION.
REMOVE EXISTING URINAL PARTITION FOR NEW IN SAME
D08 DOS LOCATION. SEE SHEET AI I I FOR MORE INFORMATION.
D15
D06 ALL RESTROOM ACCESSORIES SUCH AS MIRROR, SOAP DISPENSER,
__er i DO6 TRASH RECEPTACLE AND PAPER TOWEL DISPENSER TO REMAIN.
REMOVE WALL HEATER. PATCH AND REPAIR WALL FOR NEW
FINISHES.
j REMOVE RESTROOM WALL LIGHT FIXTURE AND PATCH WALL FOR
008 NEW FINISHES. NEW METALUX FIXTURE TO BE INSTALLED SEE
UO2 REFLECTED CEILING PLAN FOR MORE INFORMATION.
rr
D01 / D09 REMOVE EXISTING STAIRCASE DEMO PLAN BY OTHER, SEE DETAIL
O I/AI01 DEMOLITION PLAN.
)� I\ REMOVE AND SALVAGE DOOR AND HARDWARE FOR
Ex
D10 RELOCATION. SEE DOOR SCHEDULE FOR MORE INFORMATION.
OIREMOVE EXISTING SINKANDRNEWSI KIITHNEW.ALLA SALVAGE
D11EXISTING PLUMBING LINE FOR NEW $INK INSTALLATION. SEE
ARCHITECTURAL PLAN At I I FOR MORE INFORMATION.
EXISTING HVAC EQUIPMENTTO REMAIN.
D06 D11 / p13 REMOVE PORTION OF EXISTING WALL AS REQUIRED LEAVING I"
BELOW EXISTING CEILING GRID AND TILE DESIGN INTENT IS FOR
D08 DOB BULKHEAD TO REMAIN TO CREATE TRANSITION FOR OPEN DECK
CEILING. PAINT UNDERSIDE OF BULKHEAD CEILING WHITE. SEE
1 / D06 1I REFLECTED CEILING PLAN FOR MORE INFORMATION.
1, D10 ill IIIIIIII
6------------ d__.h1111111kL441.Viir-� D14 NO WORK IN THIS ROOM UNLESS OTHERWISE NOTED.
D09
D15 SALVAGE DOOR OR RELOCATION TO OFFICE I 11.
OSALVAGE DOOR AND FRAME FOR REUSE. SEE ARCHITECTURAL
D16 PLAN FOR MORE INFORMATION.
o
o j
o vx
lia
1os
Do4
DOS D12 j
_' D13
DOS D01 D13
nTnH
l06 D04-'�
u �
D16 j Iu - j
D01 D03
j
010 IIIIIIII Ir'I 'I,I IIIIIIIIIIII j
/ _Y___ IIIIIIII IIIIIIIIIIIIIIII--
D09 /
j
1ST FLOOR MEZZANINE
AREA NOT IN CONTRACT
❑ AREA OF WORK
DECONSTRUCTION PLAN N
0 4' B' 16'
THIS DRAWING, AND THE IDEAS,
DESIGNS AND CONCEPTS CONTAINED
HEREIN, ARE THE EXCLUSIVE
INTELLECTUAL PROPERTY OF SCH07
DESIGN, INC., AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE, OR
IN PART. WITHOUT THE WR17EN
CONSENT OF SCHOTT DESIGN.
I
' ^
(y)
V
Z
�
Q
OC
LU
Q
W U
LLJ
W
F-
Ow �
ii
W O
Li F-
V 00
ISSUE
DATE
DESCRIPTION
3.22.19
REVIEW SET
06.02.19
REVIEWSET2
OS.17.19
PERMIT SET
EVISIONS
ARK
DATE
DB
DESCRIPTION
iiiiiiiim
H 80�_
No.
ARI0700017 ,
STATE OF �.
TFRED PR��
PROJECT NUMBER
2018. 431
PROD. MGR DRAWN BY
JJ JJ
1ST FLOOR/ MEZZANINE
DEMOLITION PLAN
D111