HomeMy WebLinkAbout4 A111 1st Floor Mezzanine Architectural Floor PlanARCHITECTURAL LEGEND GENERAL NOTES
PLAN NOTES
NEW CONSTRUCTION
WALL
W7
PARTIAL HEIGHT WALL
®
o—u
WINDOW/SIDELIGHT
DOOR AND FRAME
N�
(SEE DOOR SCHEDULE)
EXISTING TO REMAIN
I. SEE ELECTRICAL PLAN FOR INTENDED FURNITURE LAYOUT.
WALL
2. REFERTORNISH PLAN FOR ALL ACCENT/SPECIALTY PAINT OR
WALLCOVERING THAT REQUIRES LEVEL 4 OR LEVEL 5 DRYWALL
FINISH, REFER TO MANUFACTURER RECOMMENDATIONS.
® PARTIAL HEIGHT WALL
�a WINDOW/SIDELIGHT
iIH DOOR AND FRAME
NOTE: IF IN GOOD CONDITION, EXISTING DOORS SALVAGED FROM
DEMOLITION CAN BE SUBSTITUTED FOR NEW DOORS.
WALL TYPES
NOTE:
ALL PLAN DIMENSIONS ARE FROM FACE TO FACE OF FINISHED WALL.
ALL WALLS ARE TO BE Wl UNLESS OTHERWISE NOTED.
PROVIDE MOISTURE RESISTANT / GREEN BOARD AS REQUIRED IN
RESTROOM AND/OR SHOWER ROOMS.
NOT ALL WALL TYPES LISTED BELOW ARE NECESSARILY USED ON THIS
PROJECT. REFER TO REFLECTED CEILING PLAN FOR CEILING HEIGHTS.
W7 WALL WITH INSULATION
35%"METAL STUDS AT 16" O.C.;
ONE LAYER OF s/"TYPE "X" GYPSUM BOARD
EACH SIDE;
EXTEND WALLTO UNDERSIDE OF CEILING;
FIBERGLASS SOUND BATT INSULATION INSIDE
W ALL AN D 2'-0" EACH SIDE OF WALL ABOVE
CEILING
W2 WITH INSULATION
DEMISING WALL TO DECK
3% METAL STUDS AT 16" O.CJ
ONE LAYER OF S/g" TYPE"X" GYPSUM BOARD
EACH SIDE;
EXTEND WALLTO UNDERSIDE OF DECK;
FIBERGLASS SOUND BATT INSULATION INSIDE
WALL
W3 PARTIAL HEIGHT WALL
3% METAL STUDS AT 16'O.CJ
ONE LAYER OF sJ"TYPE'X' GYPSUM BOARD
EACH SIDE;
PROVIDE WALL BRACKETS AS REQUIRED AND
SEE ELEVATION FOR WALL HEIGHT;
PROVIDE 1"BIEL PIPE ANCHORS INTO
CONCRETE FLOOR FOR SUPPORT AS
REQUIRED;
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and Local Codes
City of Camel
DATE: 09/10/19
SEPARATE PRICING
iiiiiIIIIIIIIIIN
I. OPTIONA: (9) WINDOWS ON EXTERIOR TO REMAIN, APPLY
OPAQUE FILM TO LOWER PANES AND COORDINATING
TRANSLUCENT WINDOW FILM TO ABOVE PANES (AS NEEDED).
INFILL WALL OVER LOWER PANES ON INSIDE OF BUILDING AND
VENTILATE WALL AS REQUIRED, RUN THINVENEERSTONE AS
NOTED IN COOLER DEISGN'S PLANS AROUND EXTERNAL WINDOW
SIDE,
2. OPTION B: REMOVE WINDOWS REPLACE WITH SHORTER
WINDOW (HALF OF CURRENT HEIGHT). INFILL WALL TO MATCH
EXTERIOR THICKNESS AND RUN THIN -VENEER STONE UNDERNEATH
NEW WINDOWS AT EXTERIOR.
3. PROVI DE S EPARATE PRI CE TO R EPLACE ALL EXISTI NO BLI NDS WITH
MANUAL MECHO SHADES; COLOR PRO.
4. PROVIDE SEPARATE PRICE TO ADD FILTRATION SYSTEM TO BREAK
117, EMPLOYEE BREAK 120, AND COFFEE 133.
5. PROVIDE SEPARATE PRICING TO FURR OUT CMU WALL AND
PROVIDE INSULATION IN NEW WALL CAVITY ON EAST SIDE OF
EMPLOYEE BREAK AND RESTROOM CORRIDOR. CONTRACTOR TO
PROVIDE WATER BARRIER AND INSULATION AS REQUIRED FOR
MOISTURE IN PRODUCTION ROOM. PROVIDE SOUNDS BATT
INSULATION ABOVE ENTIRE CEILING IN EMPLOYEE BREAK,
RESTROOM, AND RESTROOM CORRIDOR TO ABSORB HEAT
TRANSFER FROM WINDOWS ABOVE. COORDINATE DESIRED
INTENT WITH OWNER. COORDINATE WITH SDI ON FINAL
SPECIFICATION TO CONFIRM DIMENSIONS WILL MEET CODE.
ALIGN FINISHED WALL SURFACES, PROVIDE SAME THICKNESS
A01 STUDS AS EXISTING WALL AT DOOR INFILLS OR WHERE NEW WALLS
ARE IN LINE WITH EXISTING WALLS,
A02 EXISTING SERVER ROOM TO REMAIN, NO WORK IN THIS ROOM
OEXISTING FIRE EXTINGUISHER TO REMAIN. CONTRACTOR TO
A03 ENSURE EXTINGUISHER IS IN WORKING ORDER AND ALL FIRE
EXTINGUISHERS ARE TO BE INSTALLED ACCORDING TO NFPA 10.
EPROVIDE 24" W X 12" D X 6' -0" H SINGLE DOOR AND 4" W IRE PULL
A04 WARDROBE STYLE PLASTIC LAMINATE CABINET (PLI) WITH (6)
ADJUSTABLE WHITE MELAMINE SHELVES. PROVIDE BLOCKING AS
REQUIRED,
A0E CONFIRM THAT EXISTING WALL MATCHES WALL TYPE"WI". IF NOT,
ALTER EXISTING WALL AS REQUIRED TO MATCH I".
OPROVI D E AD DITIONAL BLOCKING IN WALLAS REQUIRED FOR
A06 TENANT'S WALL MOUNTED TELEVISION; COORDINATE EXACT
LOCATION WITH TENANT.
AO] REFER TO SEPARATE PRICING NOTES
PROVIDE 3'-0"W MOZ DECORATIVE METAL PANEL; EBONY FOG -
POLY COAT MATTE. O DESIGN) NTENTISFORTTOBEFROM FLOOR i0 CEILING. SCREEN i0 BE MOUNTEDTED IN IN "U'CHANNEL
HARDWARE,
A09 WHERE EXISTING DOUBLE DOOR WAS LOCATED. INFILL WITH
WALL AND WINDOW. WINDOW TO MATCH EXISTING FRAME,
GLASS, AND SILL HEIGHT TO THE SOUTH. CONTRACTOR TO FIELD
VERIFY OPENING PRIOR TO ORDERING WINDOW SYSTEM,
A10 NEW VESTIBULE; SEE DETAIL 2/A 104 ENLARGED ARCHITECTURAL
PLAN BY OTHER.
All
ENCLOSED STAIRCASE' SEE DETAILS AND WALL TYPES ON 3 104
AND SHEET 104 ENLARGED ARCHITECTURAL PLAN BY OTHER,
O2PROVIDE NEW 3'-0'Wx42'H PRIVACY URINAL PARTITION AT THIS
A1LOCATION. PARTITION TO MATCH EXISTING STYLE AND FINISH.
NEW FIRE EXTINGUISHER TO BE PROVIDED AND INSTALLED BY
A13
CONTRACTOR. ALL FIRE EXTINGUISHERS ARE TO BE INSTALLED
ACCORDING TO NFPA 10.
PROVIDE 6'-0Wx 2'-0'D x 3'-0" H PLASTIC LAMINATE ILLS) TRASH
A14 AND RECYCLING RECEPTACLE, DESIGN INTENT IS FOR (2) 12" DIA
HOLES IN TOP WITH STAINLESS GROMMET AND ACCESSIBILITY TO
EMPTY BINS THROUGH FRONT. PROVIDE RECEPTACLE BINS AND 4"
WIRE PULLS. SHOP DRAWINGS TO BE PROVIDED FOR SDI FOR
APPROVAL.
CONTRACTOR TO PROVIDE FLOOR MOUNTED WALL CARRIER AS
A15 REQUIRED TO SUPPORT SINK AT THIS LOCATION. IF POSSIBLE REUSE
EXISTING SINK. IN NOT, PROVIDE NEW SINK SIMILAR OR EQUAL TO
EXISTING AND REUSE EXISTING PLUMBING LOCATION.
A16 PROVIDE I F0"LONG x3'-0" WIDE SOLID SURFACE(SS2) ISLAND
COUNTERTOP AT BAR STOOL HEIGHT SUPPORTED BY INDUSTRIAL
'STEEL BEAM STYLE" LEGS. DESIGN INTENT IS FOR COUNTER TO BE
OPEN UNDERNEATH FOR BAR STOOLS. CONTRACTOR TO
COORDINATE WITH SDI FOR SUBMITTAL OF ISLAND LEGS
SUPPORTS.
A1] NO WORK IN THIS ROOM UNLESS OTHERWISE NOTED.
OSEE SHEET A 104 FOR ENLARGED ARCHITECTURAL PLAN -OUTDOOR
A18 BREAK AREA PLAN BY OTHER,
A19 REWORK EXISTING DOOR AND FRAME PER NEW DOOR LOCATION
AND SWING IF POSSIBLE, IF NOT PROVIDE NEW TO MEET LAYOUT
SHOWN.
PROVIDE DRYWALL OPENING WHERE PORTION OF WALL WAS
A20 REMOVED. PREPPED FOR PT (PTI)
P01 IF POSSIBLE, EXISTING PLUMBING TO REMAIN OR REWORKED FOR
NEW LOCATION. IF NOT, PROVIDE POTABLE HOT AND COLD
WATER AN D SANITARY WASTE AND VENT PIPING FOR SINKS.
REFER TO LANDLORD FOR SOURCE OF HOT WATER AND
LOCATION ALLOWED IN THIS BUILDING.
PROVIDE WATER LINE FOR COFFEE, WATER COOLER, AND
P02 REFRIGERATOR, IN EMPLOYEE BREAK ROOM REUSE EXISITNG
WATERLINE LOCATION FOR WATERCOOLER. CONFIRM LOCATION
WITH TENANT,
P03 PROVIDE POTABLE HOT AND COLD WATER AND SANITARY WASTE
AND VENT PIPING FOR BAR SINK AND JANITORS SINK.
REFER TO LANDLORD FOR SOURCE OF HOT WATER AND
LOCATION ALLOWED IN THIS BUILDING.
OFFICE
OFFICE
Cm
OFFICE
LOBBY
1111171
l]
OFFICE
Dm
Al ] SHARED
STAIRWELL
A11
UP
EMPLOYEE BREAK
1 ST FLOOR
® AREA NOT IN CONTRACT
❑ AREA OF WORK
LOCKED GALLEY
SLG
MEZZANINE
ARCHITECTURAL PLAN
0 4' 8' 16polil
Q
00
N b O
O
U
m a o
c
n Z
'
^
Lwo
O
p=PJ
0
O
w O M
N
OO C
25z
G
THIS DRAWING, AND THE IDEAS.
iESIGNS AND CONCEPTS CONTAINED
HEREIN, ARE THE EXCLUSIVE
INTELLECTUAL PROPERTY OF SCH07
DESIGN, INC., AND ARE NOT TO BE
ISED OR REPRODUCED IN WHOLE, OR
IN PART, WITHOUTTHE WRITTEN
CONSENT OF SCH07 DEIGN.
0
U
CIIII
0
LLJ
LLM
QT
i
N
CD
LJJ
U
LJJ
LJJ
cn
S
I—
LJJ
00
ISSUE
DATE
DESCRIPTION
3.22.19
REVIEW SET
06.02.19
REVIEWSET2
OS.17.19
PERMITSET
REVISIONS
ARK
DATE
DB
DESCRIPTION
No.
AR10700017 ,
E STATE OF �.
TFRED PR��
PROJECT NUMBER
2018. 431
PROD. MGR DRAWN BY
JJ JJ
T rT• o nne L uev� A Kuue
ARCHITECTURAL
FLOOR PLAN
A111