Loading...
HomeMy WebLinkAbout4 A111 1st Floor Mezzanine Architectural Floor PlanARCHITECTURAL LEGEND GENERAL NOTES PLAN NOTES NEW CONSTRUCTION WALL W7 PARTIAL HEIGHT WALL ® o—u WINDOW/SIDELIGHT DOOR AND FRAME N� (SEE DOOR SCHEDULE) EXISTING TO REMAIN I. SEE ELECTRICAL PLAN FOR INTENDED FURNITURE LAYOUT. WALL 2. REFERTORNISH PLAN FOR ALL ACCENT/SPECIALTY PAINT OR WALLCOVERING THAT REQUIRES LEVEL 4 OR LEVEL 5 DRYWALL FINISH, REFER TO MANUFACTURER RECOMMENDATIONS. ® PARTIAL HEIGHT WALL �a WINDOW/SIDELIGHT iIH DOOR AND FRAME NOTE: IF IN GOOD CONDITION, EXISTING DOORS SALVAGED FROM DEMOLITION CAN BE SUBSTITUTED FOR NEW DOORS. WALL TYPES NOTE: ALL PLAN DIMENSIONS ARE FROM FACE TO FACE OF FINISHED WALL. ALL WALLS ARE TO BE Wl UNLESS OTHERWISE NOTED. PROVIDE MOISTURE RESISTANT / GREEN BOARD AS REQUIRED IN RESTROOM AND/OR SHOWER ROOMS. NOT ALL WALL TYPES LISTED BELOW ARE NECESSARILY USED ON THIS PROJECT. REFER TO REFLECTED CEILING PLAN FOR CEILING HEIGHTS. W7 WALL WITH INSULATION 35%"METAL STUDS AT 16" O.C.; ONE LAYER OF s/"TYPE "X" GYPSUM BOARD EACH SIDE; EXTEND WALLTO UNDERSIDE OF CEILING; FIBERGLASS SOUND BATT INSULATION INSIDE W ALL AN D 2'-0" EACH SIDE OF WALL ABOVE CEILING W2 WITH INSULATION DEMISING WALL TO DECK 3% METAL STUDS AT 16" O.CJ ONE LAYER OF S/g" TYPE"X" GYPSUM BOARD EACH SIDE; EXTEND WALLTO UNDERSIDE OF DECK; FIBERGLASS SOUND BATT INSULATION INSIDE WALL W3 PARTIAL HEIGHT WALL 3% METAL STUDS AT 16'O.CJ ONE LAYER OF sJ"TYPE'X' GYPSUM BOARD EACH SIDE; PROVIDE WALL BRACKETS AS REQUIRED AND SEE ELEVATION FOR WALL HEIGHT; PROVIDE 1"BIEL PIPE ANCHORS INTO CONCRETE FLOOR FOR SUPPORT AS REQUIRED; RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Camel DATE: 09/10/19 SEPARATE PRICING iiiiiIIIIIIIIIIN I. OPTIONA: (9) WINDOWS ON EXTERIOR TO REMAIN, APPLY OPAQUE FILM TO LOWER PANES AND COORDINATING TRANSLUCENT WINDOW FILM TO ABOVE PANES (AS NEEDED). INFILL WALL OVER LOWER PANES ON INSIDE OF BUILDING AND VENTILATE WALL AS REQUIRED, RUN THINVENEERSTONE AS NOTED IN COOLER DEISGN'S PLANS AROUND EXTERNAL WINDOW SIDE, 2. OPTION B: REMOVE WINDOWS REPLACE WITH SHORTER WINDOW (HALF OF CURRENT HEIGHT). INFILL WALL TO MATCH EXTERIOR THICKNESS AND RUN THIN -VENEER STONE UNDERNEATH NEW WINDOWS AT EXTERIOR. 3. PROVI DE S EPARATE PRI CE TO R EPLACE ALL EXISTI NO BLI NDS WITH MANUAL MECHO SHADES; COLOR PRO. 4. PROVIDE SEPARATE PRICE TO ADD FILTRATION SYSTEM TO BREAK 117, EMPLOYEE BREAK 120, AND COFFEE 133. 5. PROVIDE SEPARATE PRICING TO FURR OUT CMU WALL AND PROVIDE INSULATION IN NEW WALL CAVITY ON EAST SIDE OF EMPLOYEE BREAK AND RESTROOM CORRIDOR. CONTRACTOR TO PROVIDE WATER BARRIER AND INSULATION AS REQUIRED FOR MOISTURE IN PRODUCTION ROOM. PROVIDE SOUNDS BATT INSULATION ABOVE ENTIRE CEILING IN EMPLOYEE BREAK, RESTROOM, AND RESTROOM CORRIDOR TO ABSORB HEAT TRANSFER FROM WINDOWS ABOVE. COORDINATE DESIRED INTENT WITH OWNER. COORDINATE WITH SDI ON FINAL SPECIFICATION TO CONFIRM DIMENSIONS WILL MEET CODE. ALIGN FINISHED WALL SURFACES, PROVIDE SAME THICKNESS A01 STUDS AS EXISTING WALL AT DOOR INFILLS OR WHERE NEW WALLS ARE IN LINE WITH EXISTING WALLS, A02 EXISTING SERVER ROOM TO REMAIN, NO WORK IN THIS ROOM OEXISTING FIRE EXTINGUISHER TO REMAIN. CONTRACTOR TO A03 ENSURE EXTINGUISHER IS IN WORKING ORDER AND ALL FIRE EXTINGUISHERS ARE TO BE INSTALLED ACCORDING TO NFPA 10. EPROVIDE 24" W X 12" D X 6' -0" H SINGLE DOOR AND 4" W IRE PULL A04 WARDROBE STYLE PLASTIC LAMINATE CABINET (PLI) WITH (6) ADJUSTABLE WHITE MELAMINE SHELVES. PROVIDE BLOCKING AS REQUIRED, A0E CONFIRM THAT EXISTING WALL MATCHES WALL TYPE"WI". IF NOT, ALTER EXISTING WALL AS REQUIRED TO MATCH I". OPROVI D E AD DITIONAL BLOCKING IN WALLAS REQUIRED FOR A06 TENANT'S WALL MOUNTED TELEVISION; COORDINATE EXACT LOCATION WITH TENANT. AO] REFER TO SEPARATE PRICING NOTES PROVIDE 3'-0"W MOZ DECORATIVE METAL PANEL; EBONY FOG - POLY COAT MATTE. O DESIGN) NTENTISFORTTOBEFROM FLOOR i0 CEILING. SCREEN i0 BE MOUNTEDTED IN IN "U'CHANNEL HARDWARE, A09 WHERE EXISTING DOUBLE DOOR WAS LOCATED. INFILL WITH WALL AND WINDOW. WINDOW TO MATCH EXISTING FRAME, GLASS, AND SILL HEIGHT TO THE SOUTH. CONTRACTOR TO FIELD VERIFY OPENING PRIOR TO ORDERING WINDOW SYSTEM, A10 NEW VESTIBULE; SEE DETAIL 2/A 104 ENLARGED ARCHITECTURAL PLAN BY OTHER. All ENCLOSED STAIRCASE' SEE DETAILS AND WALL TYPES ON 3 104 AND SHEET 104 ENLARGED ARCHITECTURAL PLAN BY OTHER, O2PROVIDE NEW 3'-0'Wx42'H PRIVACY URINAL PARTITION AT THIS A1LOCATION. PARTITION TO MATCH EXISTING STYLE AND FINISH. NEW FIRE EXTINGUISHER TO BE PROVIDED AND INSTALLED BY A13 CONTRACTOR. ALL FIRE EXTINGUISHERS ARE TO BE INSTALLED ACCORDING TO NFPA 10. PROVIDE 6'-0Wx 2'-0'D x 3'-0" H PLASTIC LAMINATE ILLS) TRASH A14 AND RECYCLING RECEPTACLE, DESIGN INTENT IS FOR (2) 12" DIA HOLES IN TOP WITH STAINLESS GROMMET AND ACCESSIBILITY TO EMPTY BINS THROUGH FRONT. PROVIDE RECEPTACLE BINS AND 4" WIRE PULLS. SHOP DRAWINGS TO BE PROVIDED FOR SDI FOR APPROVAL. CONTRACTOR TO PROVIDE FLOOR MOUNTED WALL CARRIER AS A15 REQUIRED TO SUPPORT SINK AT THIS LOCATION. IF POSSIBLE REUSE EXISTING SINK. IN NOT, PROVIDE NEW SINK SIMILAR OR EQUAL TO EXISTING AND REUSE EXISTING PLUMBING LOCATION. A16 PROVIDE I F0"LONG x3'-0" WIDE SOLID SURFACE(SS2) ISLAND COUNTERTOP AT BAR STOOL HEIGHT SUPPORTED BY INDUSTRIAL 'STEEL BEAM STYLE" LEGS. DESIGN INTENT IS FOR COUNTER TO BE OPEN UNDERNEATH FOR BAR STOOLS. CONTRACTOR TO COORDINATE WITH SDI FOR SUBMITTAL OF ISLAND LEGS SUPPORTS. A1] NO WORK IN THIS ROOM UNLESS OTHERWISE NOTED. OSEE SHEET A 104 FOR ENLARGED ARCHITECTURAL PLAN -OUTDOOR A18 BREAK AREA PLAN BY OTHER, A19 REWORK EXISTING DOOR AND FRAME PER NEW DOOR LOCATION AND SWING IF POSSIBLE, IF NOT PROVIDE NEW TO MEET LAYOUT SHOWN. PROVIDE DRYWALL OPENING WHERE PORTION OF WALL WAS A20 REMOVED. PREPPED FOR PT (PTI) P01 IF POSSIBLE, EXISTING PLUMBING TO REMAIN OR REWORKED FOR NEW LOCATION. IF NOT, PROVIDE POTABLE HOT AND COLD WATER AN D SANITARY WASTE AND VENT PIPING FOR SINKS. REFER TO LANDLORD FOR SOURCE OF HOT WATER AND LOCATION ALLOWED IN THIS BUILDING. PROVIDE WATER LINE FOR COFFEE, WATER COOLER, AND P02 REFRIGERATOR, IN EMPLOYEE BREAK ROOM REUSE EXISITNG WATERLINE LOCATION FOR WATERCOOLER. CONFIRM LOCATION WITH TENANT, P03 PROVIDE POTABLE HOT AND COLD WATER AND SANITARY WASTE AND VENT PIPING FOR BAR SINK AND JANITORS SINK. REFER TO LANDLORD FOR SOURCE OF HOT WATER AND LOCATION ALLOWED IN THIS BUILDING. OFFICE OFFICE Cm OFFICE LOBBY 1111171 l] OFFICE Dm Al ] SHARED STAIRWELL A11 UP EMPLOYEE BREAK 1 ST FLOOR ® AREA NOT IN CONTRACT ❑ AREA OF WORK LOCKED GALLEY SLG MEZZANINE ARCHITECTURAL PLAN 0 4' 8' 16polil Q 00 N b O O U m a o c n Z ' ^ Lwo O p=PJ 0 O w O M N OO C 25z G THIS DRAWING, AND THE IDEAS. iESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCH07 DESIGN, INC., AND ARE NOT TO BE ISED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUTTHE WRITTEN CONSENT OF SCH07 DEIGN. 0 U CIIII 0 LLJ LLM QT i N CD LJJ U LJJ LJJ cn S I— LJJ 00 ISSUE DATE DESCRIPTION 3.22.19 REVIEW SET 06.02.19 REVIEWSET2 OS.17.19 PERMITSET REVISIONS ARK DATE DB DESCRIPTION No. AR10700017 , E STATE OF �. TFRED PR�� PROJECT NUMBER 2018. 431 PROD. MGR DRAWN BY JJ JJ T rT• o nne L uev� A Kuue ARCHITECTURAL FLOOR PLAN A111