5 A121 1st Floor Mezzanine Reflected Ceiling Plan
LEGEND NEW OR RELOCATED Rl LIGHT FIXTURE, 2'x4', MEFALUX CRUZE LED OR EUQAL S- SUSPENDED IN OPEN CEILING ❑LIGHT FIXTURE, 2'x2' MEFALUX CRUZE LED OR EQUAL S= SUSPENDED IN OPEN CEILING FOCAL POINT -VERVE IV OR EQUAL 6 OR OWMENWERX-FORTEX EQUAL WHITE FINISH ®LIGHT FIXTURE, PENDANT, ALLOWANCE OF $500 MATERIAL COST EACH ® EXIT LIGHT FIXTURE EMERGENCYLIGHT FIXTURE $N LIGHT SWITCH $N3 LIGHT SWITCH, SWAY $ND LIGHT SWITCH, DIMMER $NP SWITCH, PROJECTOR SCREEN NG SWITCH, GARBAGE DISPOSAL (ABOVE COUNTERTOP) $ E SWITCH, EXHAUST FAN i — LIGHT CIRCUIT CEILING GRID, SUSPENDED, 2'x4' GYPSUM BOARD GYPSU ■ UNG EXPOSED TO DECK RELOCATED DIFFUSER, LAY -IN, Tx7 RELOCATED DIFFUSER, LAY IN, 1'x4' RELOCATED ® DIFFUSER, LAY -IN, XX ® EXHAUST FAN, 7x2' GENERAL NOTES I AI: L' U]YI:41iiNl�n\;iZ�_\: UIT.IYIIn1:IN IiailFiiY:IFiIN [tl CEILING GRID AND REPLACE EXISTING CEILING TILES WITH NEW 2X4 DUNE REVEAL EDGE CEILING TILES. 2. IN SOUTH EMPLOYEE BREAK AND RESTROOM AREAS REUSE EXISTING CEILING GRID AND TILE. REPLACE ANY DAMAGED OR SOILED CEILING ULES FOR LIKE NEW APPEARANCE. 3. PROVIDE LIKE CEILING PLES IN INDIVIDUAL ROOMS WHERE POSSIBLE TO CREATE UNIFORM LOOK. 4. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ON LV. IN RECEPTION AREAS, CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN SUITE, ALL LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDI OR TENANT PRIOR TO INSTALLATION. FAILURE TO DO SO MAY RESULT IN CONTRACTOR RELOCATING THESE ITEMS AT THEIR EXPENSE. 5. LAYOUT SHOWN IS INTENDED TO MEEF ASHRAE 90.1 STANDARDS. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR COMPLIANT INSTALLATION. IF ADJUSTMENT IS REQUIRED TO MEET ASHRAE 90.1, CONTRACTOR MUST NOTIFY SDI. 6. IF PROJECT CRITERIA REQUIRES ALL NEW SWITCHES TO BE OCCUPANCY SENSORS PROVIDE COMBO UNIT WITH BOTH ULTRASONIC AND INFRARED TECHNOLOGY WITH A ONE BUTTON OVERRIDE. OCCUPANCY SENSORS ARE TO BE LOCATED SUCH THAT OCCUPANCY WITHIN ANY PORTION OF INCLUDED AREA IS DETECTED. PROVIDE CEILING MOUNTED OCCUPANCY SENSORS IN OPEN AREAS AS REQUIRED, OR RELAY TIME CLOCK CONTROLS (COORDINATE WITH SDI). EXISTING SWITCHES TO BE CONVERTED IF REQUIRED BY CODE. 7. NEW DEVICES AND FACE PLATES TO MATCH EXISTING WHERE POSSIBLE, GANG MULTIPLE SWITCHES TO ACCOMMODATE MULTI -SWITCH PLATE WHEN SWITCHES ARE SHOWN ADJACENT ON PLAN. B. ELECTRICAL WORK 15 LIMITED TO A DESIGN -BUILD SCOPE AND IS OUTLINED IN THESE DRAWINGS. ALL ELECTRICAL WORK IS LIMITED TO ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES AND LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE EXISTING ELECTRICAL SERVICE IN THE BUILDING, ELECTRICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH ALL APPLICABLE CODES. SEPARATE PRICING I. PROVIDE SEPARATE PRICE FOR ALL EXISTING AND NEW SWITCHES AND FIXTURES TO BE ON OCCUPANCY SENSORS. MECHANICAL NOTES _ I. SEE MECHANICAL DRAWINGS COMPLETED BY OTHER - PLAN NOTES ROt CONTROL LOBBY AND HALLWAY LIGHTING WITH 4-WAY SWITCH ATTHISLOCATION. PROVIDE MULTIPLE SWITCHES AS REQUIRED. R02 NO CEILING WORK IN THIS ROOM UNLESS OTHERWISE NOTED. CONTROL BREAK ROOM AND HALLWAY LIGHTING WITH 3-WAY R03 SWITCH AT THIS LOCATION. PROVIDE MULTIPLE SWITCHES AS REQUIRED. R04 CONTROL OPEN OFFICE AND HALLWAY LIGHTING WITH 3-WAY SWITCH AT THIS LOCATION. PROVIDE MULTIPLE SWITCHES AS REQUIRED. R05 PROVIDENEW 2x4CEILINGGRID AND 2X4 DUNE REVEAL EDGE CEILING TILE. DESIGN INTENT IS GRID TO BEAT SAME HEIGHT AS EXISTING OFFICES. PROVIDE NEW SPIRAL DUCTWORK 8 PREPARE TO BE PAINTED PT3. R06 CLEAN AND PREPARE FOR DRVFALL PAINT. AS SPECIFIED PAINT EXISTING EXPOSED CEILING DECK, EXPOSED DUCTWORK, SPRINKLER PIPING, JUNCTION BOXES, CONDUIT, STRUCTURAL BEAMS AND FIREPROOFING IN ACCORDANCE WITH NFPA 13 6.3.8. EXTEND PAINT PAST BULKHEAD AS FAR BACK AS REQUIRED SUCH THAT ALL VISIBLE DECK AND COMPONENTS FROM EVE -LEVEL AT ANY POINT IN THE SPACE IS FINISHED WITH DRYFALL PAINT IPT_.I REFERENCE SHEET A131 FOR FU RILL ER DETAIL. R07 EXISTING OPEN DECK CEILING TO REMAIN. CONTRACTOR TO EXTEND HVAC AS REQUIRED FOR PROPER VENTILATION. SEE MECHANICAL DRAWINGS FOR MORE INFORMATION. CONTROL STAIRCASE LIGHTING WITH 3-WAY SWITCH AT THIS R08 LOCATION. PROVIDE MULTIPLE SWITCHES AS REQUIRED. R09 STAIRCASE TO HAVE WALL MOUNTED LIGHT FIXTURES SIMILAR OR EQUAL TO METALUX"BE'. VESTIBULE CEILING DRAWINGS AND LIGHTING COMPLETED BY RIO OTHER SEE DETAIL 61A105. PROVIDE BULKHEAD AT EXISTING WALL LOCATION ]"BELOW RJ 1 EXISTING CEILING GRID AND TILE. DESIGN INTENT IS FOR BULKHEAD TO REMAIN TO CREATE TRANSITION FOR OPEN DECK CEILING. PAINT UNDERSIDE OF BULKHEAD CEILING WHITE. PROVIDE STORAGE ROOM UNDER STAIR WITH (1) WALL MOUNTED R12 FIXTURE SIMILAR OR EQUAL TO FCT LED SURFACE CONFINEMENT FIXTURE. FIXTURE TO BE CEILING MOUNTED IF POSSIBLE UNDER STAIR, IF NOT, WALL MOUNT FIXTURE. PROVIDE POWER FOR EXTERIOR BREAK AREA LIGHTING AS R13 REQUIRED. COORDINATE EXACT LOCATIONS AND REQUIREMENTS WITH COOLER DESIGN. R14 PROVIDE NEW 2X4 FIXTURE AND EXAUST FAN IN RESTROOM. FIXTURE AND FAN TO BE ON SAME SWITCH. ® EXISTING DIFFUSER LAWN, 7x7 I ® EXISTING DIFFUSER, LAWN, 1'x4' AI21 0 © j I©I - F LJ E 0 lac n ❑ LJ Io ® / R12 j I I I / I I / I AI / aY / I / 1 J I F__________�3 R03 � �N GYPSUM BOARD CHUNG I- zl 0 _ NR R10 ®0 EXISTING TO REMAIN IJLIGHT FIXTURE, 2x4', FLUORESCENT, PRISMATIC LIGHT FIXTURE, 2'x2', FLUORESCENT. PRISMATIC 0 LIGHT FIXTURE, 1'X4', FLUORESCENT, PRISMATIC LIGHT FIXTURE, 1'X4', FLUORESCENT, INDIRECT Efti WALL WASHER RECESSED LIGHT FIXTURE ® EXIT LIGHT FIXTURE ® EMERGENCY LIGHT FIXTURE LIGHT SWITCH V3 LIGHT SWITCH, SWAY $D LIGHT SWITCH, DIMMER $p $G SWITCH, PROJECTOR SCREEN SWITCH. GARBAGE DISPOSAL $G SWITCH, EXHAUST FAN -\ LIGHT CIRCUIT - COUNGGRID, r SUSPENDED,2'x4' ��������� L3 m EXISTING DIFFUSER LAWN, d"xd' i I I EXISTING EXHAUST FAN, 2x2' I i JI�II W NOTE: IF IN GOOD CONDITION, EXISTING H.V.A.C. DEVICES AND CEILING TILES SALVAGED FROM DEMOLITION CAN BE SUBSTITUTED FOR NEW, NONEW HVAC DUCTWORK IS TO BE INSTALLED PER THIS SHEET. RELOCATE DIFFUSERS 8 nMECHANICAL DIFFUSER RELOCATION RELEASED FOR CONSTRUCTION `REFER TO MECHANICAL NOTES FOR FURTHER INFORMATION Subject to compliance with all regulations of State and Local Codes City of Camel �VT�SJ'�B*S4\WML DATE: \ 09/10/19 u E UJ v 1 ST FLOOR AREA NOT IN CONTRACT ❑ AREA OF WORK MEZZANINE REFLECTED CEILING PLAN N 0 4' 8' 16' � o N O m a o c L O = O Q1� O w O M N o C VG THIS DRAWING, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HERBN ARE TH E EXCLUSIVE INTELLECTUAL PROPERTY OF SCH07 DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PAWL WITHOUT THE WRITTEN CONSENT OF SCHOTT DEIGN. CV Q Z � Q O L1J U Q w U W W^' O F_ A Ri Cl W Cr Q N W V � vi L0 � ISSUE DATE DEBCRIPTION 3.22.19 REVIEW SET 06.02.19 REVIEW SET 0S.17.19 PERMIT SET REVISIONS MARK DATE DB DESCNPUON No. AR10700017 , E �. STATE OF TIERED PRD� PROJECT NUMBER 2018. 431 PROD. MGR DRAWN BY 1ST FLOOR/ MEZZANINE REFLECTED CEILING PLAN Al21