HomeMy WebLinkAboutCombined BZA and DP/ADLS Petition Request 160 W. Carmel Drive, Suite 240 Carmel, IN 46032 Phone: 317-810-1677 Fax: 317-810-1679 July 17, 2019 Mr. Mike Hollibaugh City of Carmel Department of Community Services One Civic Square Carmel, IN 46032 Subject: Lot ‘1A’ of North Augusta – 9835 Michigan Road Dear Mr. Hollibaugh, On behalf of the Petitioner, Valvoline, LLC and ECC Michigan Road, LLC, Civil Site Group, Inc. requests a combined zoning variance and DP/ADLS approval through the Carmel Plan Commission. Valvoline, LLC is desirous of constructing a new 2,077 sf +/- Valvoline Instant Oil Change auto facility at 9835 Michigan Road on 0.98 Acres located at the Northeast corner of Michigan Road and West 98th Street within the US 421 Overlay Zone and 96th Street and US 421 TIF District. The subject property is located on the east side of Michigan Road in between Prime Car Wash and Burger King. The site location has an address of 9835 N Michigan Road; Tax ID Parcel #: 17-13-07-04-01-001.001 & 17-13-07-04-01-002.000. VARIANCE REQUESTS: 1) UDO Article 3, Section 3.99 - Reduction in the Minimum Gross Floor Area required from 2,500 sf to 2,077 sf (main floor, excluding basements) 2) UDO Article 3, Section 3.95.F - Vehicle Stacking along the sides of the building 3) UDO Article 5, Section 5.39.H.2 - Building Wall Signage to be allowed facing Walnut Creek Drive (Public Access Easement - Instr. # 2011068594) Property History: The petitioned property was combined from West Carmel Marketplace Block H and part of Lot 1 of North Augusta Subdivision, Section 1 by G. William Armstrong in May, 2014 and is now known as Lot 1a, a Replat of North Augusta, Section 1, Lots 1-3, & West Carmel Marketplace, part of Block H. Instrument No. 2014016689 in Plat Cabinet 5, Slide 205. The property is subject to the West Carmel Marketplace Restriction Agreement and Grant of Easements (RAGE) dated 05/17/2006 as Instr. #200600022526 that restricts competing sale of goods and trade and limits the location and size of the proposed building on the property. Previous Development Standard Variances approved by the BZA on January 22, 2018 (Docket No. 17120014 V & 17120015 V). Mr. Mike Hollibaugh City of Carmel Dept. of Community Services Lot ‘1A’ of North Augusta July 17, 2019 Page 2 of 2 With your approval to proceed, we look forward to presenting both the Development Standard Variance requests and the DP/ADLS petition to the Plan Commission on September 17, 2019. Thank you. Sincerely, Civil Site Group, Inc. Brian S. Cross, P.E. Principal Cc: Valvoline, LLC – Richard Gallegos III; ECC Michigan Road, LLC – Thomas English and Ryan Conrad Attachments: Site Plan, Proposed Valvoline Building Elevations 2,077± G S F 20' SAN . SEWER ESMT .25' WATERMAIN ESMT . 15' ELE C. E S M T. 10' TEL E C O M E S M T.15' UT IL ITY ESMT .ACCESS ESMT . INST . #2011068594 ,#201168418, #20130763198' TELECOM ESMT . 15' UTILITY ESMT.S 31°29'44" W 56.50'N 69°48' 1 6" E 2 7 6. 5 5'S 20°11 '44 " E 125 .39 ' S 70°03' 3 3" W 2 3 5. 0 0'N 20°25'02" W 125.88'N 17°33'17" W 48.94'N 17°34'49" W25.66'N 89°33'49" E 11.90' S 20°19'58" E 16.84' S 09°16'26" E 23.16' F.F.E. = 88 5. 2 5 EX. "NO BUILD" LINE E EXISTING POND "E" NORMAL POOL = 874.0 100-YR STAGE = 881.14 DO NOT ENTERDO NOTENTER67.3'31.5 ' 37.7' 37.8'68.6 ' 41.25'63.47 ' R20' R24'R30'9' 40'25' 25'9' 15'25' R6'R4'R8'R3' 1 6 '10.3'14' 42.67' 25'20' 6' 5.3'20' R25' R1 0 ' R35' R50' R5'5' 5.7' R10 0 ' R5' 20' R4' R4' 25'R4' R2' R9' R2' R4' R4'R4' R4' R4' R4' R3' R3' R12' R5' R15' 5'WA L N U T C R E E K D R I V E30' GREENBELT30' M IN . B .S .L120' MAX . B .S .L 15' B.S. LMICHIGAN ROAD (US 421)WA L N U T C R E E K D R I V EWALNUT CREEK DRIVE **17120 0 1 4 V APPROV E D 0 1/ 2 2/ 1 8 * * 11 PARKI N G S P A C E S REFER T O A R C HI T E C T U R A L PLANS F O R B L D G. DI M E N SI O N S 9 EX. CONC . WA LKEX. CONC. WALKEX. PVMT . BURGE R KI N G EX. PVMT . PRIME C A R W A S H HOME DEPOT BICYCL E R A C K S (QTY. 2, 4 S P A C E S) PER CA R M E L U D O 5. 2 9 P K- 0 2. B C C SW SW SW D D J F G H B6 B6 TR FL A A A A A A A A MB 59'± R/W 50' R/W C C 2 D D D D BR D A A A A A A B6 B6 A A A A A A A A A A A AA A A A A A A A A A A A A T T A A A FL FL FL FL HDW T BC BC BC BC BC BC S D PROJECT NUMBER DRAWING NUMBER SHEET OF SCALE: DATE: DWN BY: CHKD. BY:CIVIL SITE GROUP, INC.GROUP, INC.PRO F ESS ION A L E NG INEERIND IA NA PE10910647STATE OF -oNREGIS TERE DBRIANSCRO S SVIOC.001 C2.0LEXINGTON, KY 40509100 VALVOLINE WAYVALVOLINE INSTANT OIL CHANGESITE PLANVALVOLINE INSTANT OIL CHANGE9835 MICHIGAN ROAD - LOT '1A' of NORTH AUGUSTACARMEL, INDIANA 46032REVISION RECORD ENGINEER: SURVEYOR: OWNER: NOTE REFER TO ARCHITECTURAL & FOUNDATION PLANS FOR ALL BUILDING DIMENSIONS. ARCHITECT: SITE LAYOUT NOTES LAND DESCRIPTION TOPOGRAPHIC & BOUNDARY NOTE UTILITY LOCATE NOTE LEGEND: CONTRACTOR NOTE NO EARTH DISTURBING ACTIVITY MAY COMMENCE WITHOUT AN APPROVED STORM WATER MANAGEMENT PERMIT. IF IT WILL BE NECESSARY TO RELOCATE EXISTING UTILITIES, THE EXPENSE OF SUCH RELOCATION SHALL BE THE RESPONSIBILITY OF THE DEVELOPER. ALL UTILITY POLES SHALL BE LOCATED WITHIN ONE-FOOT OF THE PROPOSED RIGHT-OF-WAY. DEVELOPMENT SUMMARY PROPOSED BUILDING = 2,030± G.S.F. TOTAL SITE AREA = 0.98± Ac. CURRENT ZONING = B3 / US 421 MICHIGAN RD. OVERLAY GREENSPACE AREA = 39% (16,331 SF/ 42360 SF) TOTAL DISTURBED AREA = 41,183± SF = 0.95± Ac ANTICIPATED CONSTRUCTION START/COMPLETION DATE SEPTEMBER, 2019 / OCTOBER, 2020 TOTAL PARKING SPACES PROVIDED = 11 TOTAL PARKING SPACES REQ'D = 6 (2 SPACES PER SERVICE BAY) PLAN NOTES: A SW TR D F G J C SIDEWALK NOTE ALL SIDEWALKS CONSTRUCTED WITHIN THE PUBLIC RIGHT-OF-WAY SHALL COMPLY WITH STANDARD CITY OF CARMEL AND/OR INDOT DETAILS. H B# CARMEL ENGINEERING DEPT. NOTE ALL PAVING WITHIN THE EXISTING AND PROPOSED CITY RIGHT-OF-WAY SHALL CONFORM TO THE REQUIREMENTS OF THE DEPARTMENT OF ENGINEERING. THE CONTRACTOR SHALL CONTACT THE DEPARTMENT OF ENGINEERING TO SCHEDULE A PRE-CONSTRUCTION MEETING TO REVIEW THE DEPARTMENT'S CONSTRUCTION REQUIREMENTS, STAFF NOTIFICATION REQUIREMENTS, REQUIRED INSPECTIONS FOR CERTAIN STAGES OF THE WORK AND TO REVIEW THE AUTHORITY OF THE DEPARTMENT AS IT RELATES TO WORK WITHIN THE EXISTING AND PROPOSED RIGHT-OF-WAY. MB 07/17/2019 L ALL PROPERTY CORNER MONUMENTS SHOULD BE MARKED PRIOR TO COMMENCING WITH CONSTRUCTION AND PROTECTED DURING ALL CONSTRUCTION ACTIVITY. PROPERTY CORNER MONUMENTS NOTE BR T FL DW PRELIMINARYNOT FOR CONSTRUCTIONBC S 2" 1'-8"1'-6"112"2" Application of GRACE Liquid Membrane ·ALL SURFACES MUST BE FREE FROM DIRT, GREASE, DUST, CONCRETE GROUT, OR OTHER CONTAMINANTS. ·BITUTHENE LIQUID MAY BE APPLIED AT TEMPERATURES ABOVE 26° F NOTE: THE ABOVE IS WITHIN GRACE MANUFACTURING WARRANTY SPECIFICATIONS. THIS DETAIL IN NO WAY RELIEVES THE CONTRACTOR FROM FOLLOWING ALL MANUFACTURER SPECIFICATIONS. THIS DRAWING DEPICTS MANUFACTURER'S STANDARD WATERPROOFING DETAILS. REFER TO DRAWINGS HEREIN FOR SPECIFIC FOUNDATION CONSTRUCTION. PREPRUFE 300 MEMBRANE 2'-5"PILASTER67'-6" w/ PILASTERS OVERALL BUILDING LENGTH 50'-1112"10'-812" 2'-5" PILASTER 2'-5" PILASTER 1'-0" WALL 29'-0" LUBE PITOVERALL INTERIOR WIDTH1'-0"WALL1'-0"WALL6"3 A-4 2 A-4 1 A-4 1 A-4 2 A-4 3 A-4 4 A-4 4 A-4 12'-1112" F.O. WALL TO STAIR 6"6"1'-0"1'-0" 12'-1112" F.O. WALL TO STAIR UP F.E. 17 2'-0 5/8"±11'-9"UNDER STAIR WALL ENCLOSURE800 3'-8 3/4" STAIR WIDTH13'-9"15 TREADS @ 11" EA.2'-5"PILASTER10'-812"2'-5" PILASTER 2'-5" PILASTER 6"6"6"1'-0"1'-0"27'-2"50'-1112"32'-0" TYP. EXTENDED TOWERBUILDING WIDTH w/ PILASTERS1'-0" WALL 2'-113 8" CHANGING ROOM 7'-8"A A-7.1 C A-7.1 E A-7.1 B A-7.1 O A-6.1 SIM BREAK AREA F A-7.1 8'-1012"7'-1012"5'-1038"11'-9"4'-1"D A-7.1 LUBE PIT BULK OIL 703 300 704a 3 6 7 TYP. 89 300 D1 500 708 12 903 13 1 ABOVE 102102 104 300 104 104101101 1'-1012" 14 2 10348003123105653103123103 4 800 312 310 5 6 5 310 312 3 33 300 907 5'-0" CLEAR SPACE 4'-0" NOTE: .11 10 201 TYP. 203 TYP. 206 TYP. 200 TYP. 204 TYP. 205 TYP. 7 TYP. 201 TYP. 15 TYP. 100 AIR FLOW 100 AIR FLOW 100 AIR FLOW 100 AIR FLOW ITEM QTY DESCRIPTION MANUF.MODEL # SIZE (OVERALL)ELECTRICAL PLUMBING SUPP BY INST BY REMARKSW D H V PH HP KW AMP CW HW FW W GAS 100 20” WORK STATION FAN DAYTON 20” 6” 18” 120 GC GC GC TO PROVIDE BLOCKING IN WALL AS REQUIRED 101 TBD SR-500 60” 32” 64”OWNER GC PER UL 142 SPECIFICATIONS GC SHALL RECEIVE, SET AND VENT TANKS 102 TBD SR-500 50/50 60” 32” 64”OWNER GC PER UL 142 SPECIFICATIONS GC SHALL RECEIVE, SET AND VENT TANKS 103 200 GAL. TANK –WASTE ANTIFREEZE OWNER GC 104 TBD 76” 32” 64”OWNER GC PER UL 142 SPECIFICATIONS GC SHALL RECEIVE, SET AND VENT TANKS 200 CATWALK w/ STEPS AND HANDRAILS DEVON E915 180” 52”OWNER DEVON 201 DRUM SUPPORT BRACKET DEVON INDUSTRIES E903-B OWNER DEVON 202 DRIP CATCH PAN DEVON INDUSTRIES E903-DP OWNER DEVON NOT SHOWN ON PLAN 203 OIL FILTER DISPENSING RACK DEVON INDUSTRIES E304 OWNER DEVON 204 TECHNICIAN TOOL BOARD DEVON INDUSTRIES E430-V OWNER DEVON 205 UTILITY SHELF (2-TIER)DEVON INDUSTRIES E300-2 OWNER DEVON M-307 MOLDED RUBBER BUMPER BOTH BOTTOM CORNERS 206 UTILITY SHELF (3-TIER)DEVON INDUSTRIES E300-3 OWNER DEVON M-307 MOLDED RUBBER BUMPER BOTH BOTTOM CORNERS 207 TECHNICIAN STEP STOOL COTTERMAN OWNER GC NOT SHOWN ON PLAN. ONE AT EACH CATWALK AND ONE AT UPPER LEVEL UPPER LEVEL UPPER LEVEL - A1N2222A320B8C2P6-D9990010 LOWER LEVEL LOWER LEVEL - A2N2222A320B8C2P6-D9990001 300 SEEPLAN INVENTORY SHELVING DEVON INDUSTRIES E-601 OWNER DEVON SEE PLANS TO DETERMINE LINEAR FOOTAGE NEEDED 301 CASHIER / COMPUTER STATION w/ DOORS DEVON INDUSTRIES C7030-DX 30” 30.5” 54”OWNER DEVON BLACK 302 PEDESTAL POST PODIUM CP-09 OWNER DEVON G.C. TO PROVIDE ELECT. REF. ELECTRICAL PLANS 302A PEDESTAL POST PODIUM FP-13 OWNER DEVON G.C. TO PROVIDE ELECT. REF. ELECTRICAL PLANS.SPACE SAVER 303 DEVON INDUSTRIES E101 30”14” 41”OWNER DEVON REQUIRES 26”x10” FLOOR OPEN’G. HOSE GUIDES INCLUDED w/ UNIT (BY GC) 304 ROLLING DRAIN PAN DEVON INDUSTRIES E203 OWNER DEVON NOT SHOWN ON PLAN 305 “PIT BULL” SAFETY NET PIT BULL OWNER GC OPTIONAL TO #305 PIT COVER. VERIFY W/ OWNER REP. 306 AUTOMATIC TRANSMISSION FLUID EXCHANGE EQUIPMENT RTI 15.5” 29.5”44”115 1 2 OWNER OWNER 307 ANTIFREEZE DRAIN AND FILL SYSTEM RTI 28” 21” 44”OWNER OWNER 308 FLUID EVACUATOR FLUID EVACUATORS EZ1 10” Ø 30”OWNER OWNER NOT SHOWN ON PLAN 309 LOW RISE CAR LIFT NORCO 79324G W/VIOC ACCESSORIES OWNER GC PLUMB DEVON 310 WINDSHIELD WASHER FLUID VISIBLE SOLUTIONS OWNER OWNER 105 GALLON TANK 311 OIL DISPENSING BAR OWNER DEVON 312 ANTIFREEZE TANK OWNER GC 400 AIR COMPRESSOR SAYLOR-BEALL SINGLE PHASE VT-735-120-1-B THREE PHASE VT-735-120-3 OWNER GC WIRING BY GC, VIBRATION ISOLATION DAMPERS ON COMPRESSOR SHALL BE INSTALLED BY ZONES 401 NOT USED 402 ELECTRONIC TIMER DRAIN VALVE SYSTEM AIRCEL OWNER OWNER INSTALLED ON BOTTOM OF AIR COMPRESSOR 403 HOSE GUIDE ASSEMBLY ALEMITE OWNER DEVON 404 HOSE REELS ALEMITE OWNER DEVON 405 AUTOMATIC TIRE INFLATOR 89-XDA-VAV 110 1 OWNER HALTEC (1) STAND; ALL OTHERS WALL MOUNTED; PEX PIPING 406 SERVICE BELL RINGER GC GC 500 LOCKERS 31” 21¼” 84½”OWNER GC SECURE TO WALL PER MANUF'S RECOMMENDATIONS 501 WAITING ROOM CHAIRS OWNER OWNER 502 STOOL OWNER OWNER 503 SECURITY CABINET OWNER GC 504 RECTANGULAR CONVEX MIRROR GRAINGER 1CYZ1 18”12”GC GC MOUNT AT 77” A.F.F. 600 LOGO SIGN OWNER SIGN GC SHALL COORDINATE w/ SIGN CONTRACTOR 601 FASCIA SIGN OWNER SIGN GC SHALL COORDINATE w/ SIGN CONTRACTOR 700 GRAB BAR - 36”BOBRICK B6806X36 GC GC 701 GRAB BAR - 42”BOBRICK B6806X42 GC GC 702 TOILET PAPER HOLDER BOBRICK B-685 GC GC 703 PAPER TOWEL DISPENSER GRAINGER 4TE15 12¾” 10½” 14¼”GC GC 704 LIQUID SOAP DISPENSER GRAINGER 3U515 7”5¾” 16½”GC GC 704A FOAM SOAP DISPENSER GRAINGER 3WU72 6” 4”10½”GC GC GOJO DISPENSER 705 MIRROR BOBRICK B-165X1836 GC GC 706 GRAB BAR – 18” (VERTICAL)BOBRICK B7806X18 GC GC 707 BABY CHANGING STATION KOALA KARE KB200-00 CREAM GC GC 708 REFRIGERATOR AMANA ASI2175GRB GC GC 21 CF SIDE BY SIDE – BLACK w/ ICE MAKER BEST BUY SKU# 6191419 708 **REFRIGERATOR (ALTERNATE)**FRIGIDAIRE LFSS2312TE GC GC 22.1 CF SIDE BY SIDE – BLACK W/ ICE MAKER LOWE’S ITEM# 852865 800 AMEREX B456 GC GC ALL FIRE EXTINGUISHER TYPES/ MODELS SHALL BE CONFIRMED WITH LOCAL FIRE MARSHAL PRIOR TO PROCUREMENT AND INSTALLATION 801 FLOOR SAFE MB2014K-SG4440 GC GC 901 MURAL OWNER GC 902 SNAP FRAME DISPLAY 28”44”OWNER GC 903 1 TABLE & 4 CHAIRS OWNER GC BREAKROOM FURNITURE 904 INFORMATION SIGN 28”44”OWNER GC 905 1’-10” X 2’-6” ACCESS PANEL BEST ACCESS DOORS SKU: BA-AHD-22-30 22” 30”GC GC 906 ANTIFREEZE WASTE SINK 18” 12” 14”GC GC SEE DETAIL 1/A-7 7 2 2 1 3 3 6 3 3 3 6 3 1 3 1 3 0 2 3 3 1 1 1 3 2 1 2 1 1 3 2 4 1 2 4 1 1 3 3 3 1 1 1 3 1 2 1 1 1 1 - 5 1 1 4 1 2 3 1 500 GAL TOTAL SINGLE WALL 1 COMPARTMENT TANK 500 GAL TOTAL SINGLE WALL 2 COMPARTMENT TANK 250 GAL EACH COMPARTMENT 600 GAL TOTAL SINGLE WALL 3 COMPARTMENT TANK 200 GAL. EACH COMPARTMENT FIRE EXTINGUISHER 10LB ABC W/ WALL MOUNT BRACKET CORPORATE SAFE SPECIALIST HALTEC CORPORATION DEVON INDUSTRIES DEVON INDUSTRIES GRAINGER #2LY89 SR-600 33/33/33 LUBE DISPENSING CONSOLE 11 DISPENSERS BRW UNLIMITED. SEVICES, INC. MILTON #805 100' HOSE GC TO PROVIDE BLOCKING AS REQUIRED SAFE TO BE PROVIDED w/ (5) KEYS 105 GALLON TANK WITH PNEUMATICPUMP 300A SEEPLAN INVENTORY SHELVING DEVON INDUSTRIES E-601 (1'-0" DEPTH)OWNER DEVON SEE PLANS TO DETERMINE LINEAR FOOTAGE NEEDED 907 FAST TRACK RACK (GLOVE DRYING)48”2”GC GC PROVIDE MOUNTING HDWR. & 10 COMPACT HOOKS2RUBBERMAIDMODEL# 48" RAIL (BLACK) SCALE:0 FLOOR PLAN LOWER LEVEL 1/4" = 1'-0" Date Drawing No. Project No. Scale Checked Drawn Drawing Title 2019 CESO, INCc DateNo.Revisions/SubmissionsJSBVALVOLINE INSTANT OIL CHANGEPROJECT ADDRESS CITY, ST XXXX(SEE 2BAY, 3BAY, 4BAY PROTOTYPE CODES IN SHEET TITLE BELOW)- xx.xx.19OWNER REVIEWXX.XX.19175 MONTROSE WEST AVE., SUITE 400, AKRON, OH 44321 PHONE: (330) 665-0660 FAX: (888) 208-4826 \\cesoinc.local\root\data\PROJECTS\VALVOLINE\Z_Reformatted Prototype\3BLH-STnD-EXTwR ArchCAD 2019-05\EXTR_3BLH A1 Lower Level Floor Plan, 5/7/2019 12:10:18 PM, RICHARDCESO AS NOTED A-1 LOWER FLOOR PLAN BRICK-EIFS OPTIONSTONE-EIFS OPTIONBRICK-BRICK OPTIONSTONE-BRICK OPTION REMARKSFINISHITEMWAINSCOTFULLREMARKSEXPOSEDCEILING /WALLSBASEFLOORROOMNOTES:BOTTOMHEIGHTHEIGHTSTRUCTURETOPMark ColorFinish Manufacturer ProductPrimers:Paints:Wall Panels:-Plastic Laminate:Floor Finish:Base:Solid Surface:PR-1PR-2PR-3Tinted to matchTinted to matchTinted to matchSherwin WilliamsHeavy Duty Block Filler B42W46Sherwin WilliamsSherwin WilliamsPrep-Rite 200 Prim er B28W200PT-1PT-2PT-3PT-4PT-5SW7012 (Creamy)SW7515 (HomesteadBrown)Ceiling WhiteValvoline RedUltra WhiteSemi -glossSemi -glossSemi -glossSemi -glossSemi -glossSherwin WilliamsSherwin WilliamsSherwin WilliamsSherwin WilliamsSherwin WilliamsWater Base Industrial Enamel B53-300 SeriesSher -Cryl HPA B66 -300 SeriesWater Base Industrial Enamel B53-300 SeriesWater Base Industrial Enamel B53-300 SeriesW-1W-2P 151 Light Gray#731 RedSmoothSandstoneMarliteCrane CompositesFRP Panel w/ Matching Color Trims – Class CFRP Panel w/ Matching Color TrimsPL-1Dove GreyMatte WilsonartStandard HPL Finish D92-60F-1F-2F-3B-1B-2SS-1See Finish Note F51910 Classic BlackClearHigh GlossSilikal / SherwinWilliamsArmstrongMastureKureBlackSee Finish Note C#9030 MLSmoothRoppe or Eq.SilikalWilsonArtGibralter (Window Sills )Seamless, Resinous System700 Series 4” Rubber Cove BaseMastureKure CC 300 , 3 Coats, Min. See Finish Note E12”x12”x1/8” VCT (Wax Floor)Seamless, Resinous System - See Finish Note FPro -Cryl Primer B66 -310 SeriesBaja MelangeWater Base Industrial Enamel B53-300 SeriesColor to match Pantone 485 RED4'-0" OR PERCIVIL DRAWINGS67'-0" (TYP.)BUILDING LENGTH3'-33 4" 31'-0" TYPICAL SERVICE BAY OVERALL BUILDING WIDTH 5'-0" OR PER CIVIL DRAWINGS (BLACK CONC.)2A-4DOWN3'-934"OPN'G WIDTH6'-0"14'-0" OVERALL13'-0"OPENING LENGTHSTUD TO OPN'G1A-43A-44A3b3A3b2A3a1A3a5'-0" OR PER CIVIL DRAWINGS (BLACK CONC.)9'-0"67'-6" (TYP.) LENGTH@ STANDARD TOWERSw/ PILASTERS4'-0" OR PERCIVIL DRAWINGS5'-1012"MASONRY OPN'G 6'-412"MASONRY OPN'G 5" 1'-212" 1'-7" M.O.4A-44A-43A-43'-412"M.O.2'-5"10'-812"2'-5"2'-5"10'-0"MASONRY OPN'G3'-4"10'-0"MASONRY OPN'G6'-312"2A-410'-0"MASONRY OPN'G3'-4"10'-0"MASONRY OPN'G2'-8"2'-5"10'-812"2'-5"2'-5"3'-412"M.O.1'-712"4'-0"5TYP.111820411393912181818181211111212393932'-0" TYP. EXTENDED TOWERBUILDING WIDTH w/ PILASTERS 136"TYP. 2'-51 4"3'-11"1'-914"11" TYP.2'-1134"7'-658"5'-434" 1'-7"M.O.11" TYP.1A-4.12A-4.11A-414'-6"44203"VEHICLEENTRANCEVEHICLEENTRANCEVEHICLEEXITVEHICLEEXIT42TYP.42TYP.10'-0"MASONRY OPN'G3'-4"10'-0"MASONRY OPN'G3'-4"1118121112VEHICLEENTRANCEVEHICLEEXIT13'-47 8"BAY 1BAY 2OFFICEUTILITY ROOMDRUMTRANSFERSTATIONJA-7.1LA-7.1KA-7.1GA-7.1IA-7.1HA-7.17A-7BAY 35'-114"17'-8"2'-8"3A-7JKLIA-7NOPM12681515151516172321FD800902TYP.504504800800706707502503801703704A306405300A30728313214341001035303623515406100301405ALIGN(TYP.)90240590129293790640311OA6.1SIMOA6.1SIMLA6.1GA6.1C15'-934"EQ.EQ.388'-13 8"DD3D5D7D12AD12CD12BD12DD6D11D10D12ED12F6'-078"STORAGEAREA4'-0"5'-314"OPP.HANDD1315714"WAITING AREAA-7BCDA27BA7'-73 4"19D2D4BA6.1501TYP.19UNISEX R.R.MECH. ROOM2'-434"FD703704A-7FGHE2162323FD700702701400402244042627251515EA6.1TYP.3'-7"OA6.1SIM705D8D910"512"512"92"1'-0"1'-0"5041004051ALIGN(TYP.)302403403302BAY 1BAY 2309TYP.2305TYP.22223FD3033323FD332212'-5"8'-3"4'-012"(TYP.)7"5'-0"(TYP.)10'-2"6'-1134"3'-8"3'-2"OPN'G3'-2"OPN'GEQUAL(TYP.)EQUAL(TYP.)414140330222223FD3033323FD4'-012"(TYP.)7"5'-0" (TYP.)10'-2"3'-2"OPN'G41SCALE:0FLOOR PLANUPPER LEVEL1/4" = 1'-0"DateDrawing No.Project No.ScaleCheckedDrawnDrawing Title2019 CESO, INCcDateNo.Revisions/SubmissionsJSBVALVOLINE INSTANT OIL CHANGE PROJECT ADDRESS CITY, ST XXXX (SEE 2BAY, 3BAY, 4BAY PROTOTYPE CODES IN SHEET TITLE BELOW)-xx.xx.19OWNER REVIEW XX.XX.19 175 MONTROSE WEST AVE., SUITE 400, AKRON, OH 44321PHONE: (330) 665-0660 FAX: (888) 208-4826 \\cesoinc.local\root\data\PROJECTS\VALVOLINE\Z_Reformatted Prototype\3BLH-STnD-EXTwR ArchCAD 2019-05\EXTR_3BLH A2 Upper Level Floor Plan, 5/7/2019 12:10:07 PM, RICHARD CESOAS NOTEDA-2UPPER FLOORPLANBRICK-EIFS OPTIONSTONE-EIFS OPTIONBRICK-BRICK OPTIONSTONE-BRICK OPTION