Loading...
HomeMy WebLinkAbout203JGB - Sewer Permit10i01 N. College Avenue Suite A Indianapolis, Indiana 46280 phone 317-844-9200 fax 317-844-9203 www.trico.eco Residential SANITARY SEWER PERMIT 999913400 Permit Type Final Subdivision Jacksons Grant Project WO Project Name Project Developer Lift Station Treatment Plant Parcel Acreage EDU in Gallons 2017-1339 Section Number Jacksons Grant Section 4 Lot Number Jackson's Grant Real Estate Company Address Number Local Sewer Charge - District Contribution Plan Review and Inspection Application Fee EDU Fee Interceptor Fee Other Fees Fees Due Invoice Number 26 Jacksons Grant Address 2 MIX Street 0.21 City 310 Zip Code County 0.00 guilder 0.00 150.00 Phone Number 1908.00 Owner 0.00 Phone Number 0.00 2058.00 Occupant Phone Number 4 203 12224 Hobby Horse Drive Carmel 46032 Hamilton Wedgewood Building Company 317-669-6315 PLEASE NOTE: Installation of building sewer shall be per the specifications of the TriCo Regional Sewer Utility (see reverse) and any conditions noted below. All installations shall be inspected by TriCo personnel during "open trench" phase and before backfilling with stone to twelve inches above the pipe. NO footing or foundation drains, or other sources of ground or stormwater, shall be permitted to enter TriCo's sanitary sewer system. TriCo will assume no liability for drains which are below the grade level of the nearest downstream manhole nor for laterals which are extended beneath driveways or sidewalks. The permit holder (property owner, developer or builder) will be responsible for damages to TriCo's sewer system. This includes damages to manholes, castings, manhole lids and the like; caused by construction activity on the building site which is the subject of this permit. Inspections by TriCo are MANDATORY and shall be arranged by contacting TriCo's office at 844-9200 24 hours in advance. All new construction will be placed on billing two months after connection has been made or when water is connected, whichever comes first. The building has: Main ID: JG874JG875 Grease Trap Slab Foundation usMH Grease Interceptor Crawl Space ManholelDs JG-874 JG-875 DDSSMH� Grit Interceptor Basement YES Lid Elevation 862.31 �// 861.59 ✓/ Grinder Station First Floor Elevation 864.60, , 864.60v/ Water Service City of Carmel Basement Elevation 854.40v 854.40�r Calculation is based on both Manhole Lid Elevations and the elevation of the First Floor 2.29 3.01 Ft. Per Ordinance 9-13-99 and the elevations provided, the substructure shall be plumbed by: Ejector Pump Only TriCo currently requires that an AI inspection is performed and a Certificate of Compliance is issued prior to occupancy / sale of a property. Please review attached I/I Permit. Manholes shall remain accessible at all times. Buried manholes will be corrected by the Developer/Owner. The proper class of cleanout must be installed every 100 feet of lateral pipe measured from sewer main to structure. The terms of the conditional permit, if any, are listed below Plans have been submitted. All fees have been paid. No certificate of insurance required. No additional permits required. No manhole core permit required. The facility is not classified as a FOG By signing below, I attest that I am Builder / Owner Signature Printed Name (Notes) Yam% U(- -'ltje to Approved By Ryan Permit is valid for agree to accept responsibility for all work done under this permit. Phone Number_ - orra`r" Q1 —off �5 L from the date issued. Permit valid only with K SUMMARY OF LATERAL INSTALLATION REQUIREMENTS 1. Only one building may connect to the sewer main per lateral unless otherwise approved by ThCo. 2. Foundation drains, sump drains, downspouts and other storm water drains shall never be connected to the sanitary sewer. Site dewatering systems shall never be discharged to the sanitary sewer. 3. The existing sewer line from the building to the septic tank may only be reused if it is located under a building addition, patio, porch or paved driveway, and the line passes an air test that is observed by TriCo. Contact TdCo for more information about air testing requirements. The property owner is responsible for testing costs. 4. TriCo shall inspect all new laterals or lateral repairs in their entirety. Final connection to the sanitary sewer must be observed by Trico. The property owner or contractor must notify TriCo prior to backfilling. Inspections must be scheduled at least 24 hours in advance. If an inspection fails and subsequent inspections are required, or if the contractor is not on site for the scheduled inspection, a $100 fee will be assessed and must be paid prior to scheduling the reinspection. 5. Septic system contents or effluent shall never be discharged to the sanitary sewer. Be advised that your county health department regulates septic systems. Upon connection to sanitary sewer, a septic tank must typically be abandoned, pumped clean, and filled completely with earthen material. Contact your county health department for more information on septic system and abandonment requirements, and to notify the department of any abandonment. 6. The following materials are acceptable for use in gravity sewer lateral installation or repair: PVC pipe: SDR 35 or SDR 26, ASTM D3034, 6" diameter PVC pipe, pressure rated: SDR 21, ASTM D2241, 6" diameter PVC restrained joint pipe for directional drilling: Certaflo Greenline SDR 21, ASTM D2241, 6" diameter All gasketed joints shall meet ASTM D3212 All fittings shall be SDR26 or better Ductile iron mechanical joint fittings with proper hardware SDR 26 gasketed repair sleeves or Indiana Seal shear guard Fernco and similar flexible couplings are only acceptable in certain circumstances and shall not be used without prior approval from TdCo Cleanouts: 6" threaded PVC caps Bedding: Use #8 crushed stone or fractured face aggregate The following materials are acceptable for use in low-pressure sewer lateral installation or repair: HDPE pipe for directional drilling: OR 11 IPS, 1.25" diameter, PE4710 Connections shall be made via electrofusion or using polypropylene or stainless steel compression fittings Electrofusion high volume tapping tee, rated 200 psi, PE4710 1.25" IPS full port 1/4 turn fusible PE ball valve, rated 200 psi Threaded swing check valve, 316 stainless steel, rated 200 psi Contact TriCo for acceptable pump station materials, equipment, pumps and other requirements 7. For gravity and low-pressure systems, the line leaving the building shall not exceed 3' in length before a cleanout must be added and the line is transitioned to 6" diameter SDR 35 PVC pipe. Glued joints are not allowed after 3'. No additional glued fittings are allowed between the building and the transition/cleanout. For all gravity lines, cleanouts shall not be spaced more than 100' apart between the building and the sewer main. See TdCo's standard drawings for more information on cleanout installation. 8. Bedding material shall be placed from at least 6 inches below to 12 inches above the pipe surface. The trench shall be a minimum of 18" wide with at least 6" of clearance on both sides of the pipe. Material shall be placed over the pipe and tracer wire after inspection. Soft, unstable or unsuitable material found below and near the lateral, including any fill or foundation backfill material, must be removed and replaced with #8 stone. The contractor is solely responsible for establishing stable pipe bedding conditions. 9. #10-AWG solid copper tracer wire shall be laid on top of and run the entire length of the lateral. All splicing of tracer wire shall use 3M splice kit model DBR/Y-6, King Innovation Dryconn Direct Bury Lug Aqua catalog #90220, or TdCo approved 10. Laterals shall be installed at least 20' from water wells unless PVC pressure grade pipe is used. Any proposed installation requiring pressure pipe shall be reviewed by TriCo prior to installation. Where a transition is made between SDR 35 pipe and pressure grade SDR 21 pipe, a ductile iron gasketed mechanical couplings must be used. 11. Laterals less than 5' deep shall be at least 24" from the property line. Laterals more than 5' deep shall be at least 36" from the property line. Where the lateral runs in close proximity to the property line the property corners must be accurately staked by a professional land surveyor prior to inspection. 12. Laterals running parallel to a building or structure shall be at least 36" from the face of a crawl space or slab on grade foundation and 60" from the face of a basement foundation wall. Spacing requirements also apply with respect to the ancillary structure's foundation depth. Ancillary structures (e.g. window wells) and other utilities shall not be placed over or near the lateral. TriCo may adjust requirements where future access to the lateral may be obstructed by other utilities. The contractor should call to discuss further if he/she believes this could be an issue. 13. All infrastructure connected to TriCo's sewer system may be tested, inspected, or televised at ThCo's discretion, and must remain accessible and properly maintained. 14. Call 811 or 1-800-382-5544 before you dig. For more information go to www.indiana811.org. TnCo Regional Sewer Utility 10701 North College Avenue Suite A Indianapolis, Indiana 46280 Phone (317)-844-9200 Fax (317)-844-9203 Revised 03/1912019 TriCo Regional Sewer Utility 1 or01 N. College Avenue Suite A Indianapolis, Indiana 46280 phone 317-844-9200 fax 317-844-9203 www.trica.eco Residential 1 & I Permit Ordinance 12-08-08 Lateral Location Address Number Address 2 Street City .._. _.... State Zip Code Subdivision Section Number Lot Number Permit Information 12224 Hobby Horse Drive Carmel IN 46032 Jacksons Grant 4 ...... __. _203 Facility Features and Addition Information Slab Foundation Crawl Space Basement Cleanout Ejector Pump Sump Pump Grinder Station Program Specifications Owner / Occupant Information Owner First Name Last Name Phone Number Mobile Number Fax Number Email Address Owner Address if Different Address Number Address 2 Street City _.. _._ _... State Zip Code Builder Information Builder Phone Number Square Footage Water Type YES Basement Status YES Main ID YES Lift Station YES Wedgewood Building Company 317-669-6315 City of Carmel Ejector Pump Only JG874-JG875 26 Jacksons Grant ■ This program requires prior to the sale/occupance of a property that the property owner/builder notify TriCo and schedule an inspection. The inspection will verify that: • Downspouts are not connected to the sanitary sewer • The sump pump is not connected to the sanitary sewer • Cleanout caps are in place and watertight • No yard drains are connected to the sanitary sewer • There are no sinkholes or other indications that the sewer lateral is leaking • 5 Ton or greater HVAC units do not dishcarge condenstion to the sanitary sewer. • If deficiencies are found, the property owner will be notified and must make corrections immediately. The property owner will need to schedule a follow up inspection. If a certificate of compliance is not issued within 30 days of the change in ownership, a sewer surcharge of $20 per month will be assessed and added to the sewer bill. Owner /Occupant SatureDate: Approved By: PV AA. f Date: tall 2619 '19 SEP 11 PH 2:08 JACKSON'S GRANT PLOT PLAN ON WILLIAMS CREEK Nei INST.#2018-009549 II LOT #203 —SECTION 4 I V PREPARED FOR CITY OF CARMEL, INDIANA WEDGEWOOD BUILDING COMPANY 12224 HOBBY HORSE DRIVE APPROVED er al y r..ww •r ss, m, a..,4 aro LOT SIZE: 8.975 SQ.FT. CONC. DRIVEWAY: 1,180t SQ.FT. PUBLIC WALK: 244t SQ.FT. PRIVATE WALK: 25t SQ.FT. SEEDING: 1,711 SQ.FT. SOD: 302f SQ.YD. LOT #203 8,975 S.F. POs(y1 PROPOSED 16 A. RESIDENCE 0 0. \\•✓ F.F. = 864.6' �• GAR. = 863.3' Q \ F BSM'T = 854.4' "ol+t-NA1M�T" �9 PROP. % DRIYE MANN�A1`n�J yry,3+ ��Ess18LE REMAINT GAApE a \ & A TIMES AT AA -At ue \� s1oEWPlx M A A``````````Quuuum �/Q No. * LS20300026' Tt STATE OF %�A'"`````` NOTE,DRIVE ENTRY TO CONFORM N1TH CITY OF CARMEL STANDARDS — THE LOCATIONS, DIMENSIONS, AND WIDTH ALONG THE PROPOSED PUBLIC SIDEWALK WERE SCALED OR TAKEN FROM ENGINEERING CONSTRUCTION PLANS PREPARED BY OTHERS OR AS FRONDED. K — VERIFY SANITARY LATERAL LOCATION PRIOR TO CONSTRUCTION — IT SHALL BE THE RESPONSIBILITY OF THE BUILDER/CONTRACTOR TO VERIFY THE BUILDING 000.0 — PROPOSED GRADE DIMENSIONS, BUILDING LOCATIONS. THE LOCATION OF OTHER PERTINENT FEATURES AND ELEVATIONS PRIOR TO THE START OF CONSTRUCTION. THE INTENDED USE OF THIS PLOT PLAN IS 000.0 — EXISTING GRADE FOR SECURING BUILDING PERMITS ONLY AND SHALL NOT BE USED FOR ANY OTHER PURPOSE. LAND DEVELOPMENT CONSULTING DRWN: TAT DATE 09/10/18 SCALE: 1" = 30' �/JULW @ LAND SURVEYING SERVICES JOBf 19-640 REV.: 1111./L 11650Olio Road. Suite#1000-269 ZONED: BRIDGEMONT F.F.E. HSE: 864.6' NORMFishers, Indima 46037 mil ll Phone: (317)-841-8754 ZONING: 5'/10' SIDE F.F.E. GAR: 863.3' 'PUINTIN. TUUINTMWUHTDOUX71JM Fax:(317}E41-6762 F.F.E. BSM'T: 854.6' E-mad: Tmy®Tmenonhindy.mn 20' REAR