HomeMy WebLinkAboutA200 FLOOR PLANrl
II
II
2
1
TOILET RM t
50' 0-1/2"
12' 6-1/2" 5'-0"
123 I
F
-ly
2 i I 3 i I 3
F-3 122 I i I
HALL /� CLOSET
00 BREAK ROOM 1 123 I / 3 \ F-z t 12s
tz2 SERVICE 007
SINK a OFFICE F-3
'� ❑t tea Q Iza Izs
z 2 ® z� z oo ® oo ® oo ® o0
1 8'-0" 8'-0" 5'-7" 8'-0"
IZ
CONSULTING CONSULTING CONSULTING HOLD CONSULTING
1112-0 Fill 118 tl7 I76
F-2 F_p F-1 F_1 F-1
1 120 119 I tte t — — — � 1 II6 I
CORRIDOR
t t 1,_2��41-0416 ° 8 _2" F-2 5 6'! ° 6 t81_Dlt
I
� nl
PRETEST l07 PIRETEST
m7 __ 11u -
1 I 'i 11 II o
PRETEST --- 1
m 108 I F-2
_ CORRIDOR CONTACT LENS CC RRIDOR
--- -- - i C08 F-2 STORAGE; t 11z
o
1 i
_--�`_-' SP CIAL TESTINGILET RM, `I 113 tl3 0
Itl 06
IF —I r i F-2 F`
ro
00 1
3 WORK ROOM • F-1
Itta4 03 1 i
F-3 I 1 I
F— 1 i
RISER ROOM 4'-0" 8'-2" 4'-0"
N.LC. 0 o
F_2 1 CONTACT LENS
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and meal Codes
City of Carmel
DATE: 09/17/19
t
RECEPTION
F I tUt
2 0
F-1
CONSULTING
Itt is
F-2
tte
114
CONSULTING
Itt to
/2
177111
A00
WAITING
toe
Ora
❑2
10"-
F-I 2
U 2
2
00 L
J FLOOR PLAN
I
FLOOR PLAN KEYED NOTES
Ol P. LAM. RECEPTION DESK WITH ACCESSIBLE COUNTER.
EXISTING 1 HOUR RATED DIMISING PARTITION
FLOOR PLAN LEGEND
EXISTING WALLS AND PARTITION TO REMAIN
NEW WALLS OR PARTITIONS:
( DOOR MARK: REFER TO DOOR SCHEDULE
F-2 FINISH: REFER TO FINISH SCHEDULE
SLAB TO CEILING PARTITION (NOT RATED)
5/8" GYP BD ON BOTH SIDES OF
3-5/81' 20 GA METAL STUDS, 241, O.C.
TO UNDERSIDE OF CEILING
ALL PARTITIONS ARE TYPE t UNLESS OTHERWISE NOTED
FURRING PARTITION
5/8" GYP BD ON ONE SIDE OF
3-5/8" 20 GA METAL STUDS, 2411 O.C.
TO UNDERSIDE OF CEILING
EXTERIOR WALL FURRING PARTITION
ADD 5/8" TYPE X GYP BD ON STUDS TO 6" ABOVE CEILING
AT EXSITING EXTERIOR WALL, TYP
1
CRA
CRAIG
BENNETT
ASSOCIATES
ARCHITECTS
TENANT
MY EYE DR
1950 OLD GALLOWS RD
SUITE 520
VIENNA, VIRGINIA 20182
703-847-8899 FAX 966-414-6476
Contact: Suzanne Berardi -Gould
571-455-8191
ARCHITECT:
CBA ARCHITECTS, PC
1239 PINE HILL ROAD
McLEAN, VIRGINIA 22101
703-847-6900 FAX 847-6955
www.cba-architects.com
Contact: Craig Bennett
cbennett@cba-architects.com
703-975-2400
MEP ENGINEER:
DWYER ENGINEERING
552 FORT EVANS ROAD NE, #200
LEESBURG, VIRGINIA 20176
703-777-5988 FAX 703-439-2588
www.dwyer.com
Contact: Brian Davis
BDovis@dwyer.com
703-777-5988 EXT. 110
MY EYE DR
SHOPPES ON MAIN
SOUTHWEST CORNER OF
MAIN ST & GRAND AVE
CARMEL, INDIANA
For Permit 07/18/19
```GwoDnuB
STATE OF -
�'. /4, I ANP P
%aiglRCi nin �C'C`o�a`
Craig ysigned
by Craig Bennett
Bennett Date.2019.0907
15.21 24-0400
FLOOR PLAN
SHEET
A200