HomeMy WebLinkAboutM200_Mechanical Planr RELEASED FOR CONS] Subject to compliance with all of State and Local Cot City of Carmel ROOFTOP A/C UNIT FLEXIBLE CONNECTION GASKET FULL SIZE OF UNIT CONNECTION TOP OF CURB MUST BE SET DEAD LEVEL RIGID INSULATION CANT STRIP--- ROOFING DECK ROOF JOIST FRAME AROUND OPENING PER STRUCTURAL DETAIL HOLD TOP OF DUCTWORK CEILING AS TIGHT AS POSSIBLE TO BOTTOM OF JOIST DUCT— SEE PLAN FOR FIELD VERIFY SIZE AND ROUTING RTU MOUNTING DETAIL NO SCALE DUCT w SPIN —IN FITTING w BALANCING DAMPER WITH LOCKING QUADRANT *TRUNK EXTRACTOR BRANCH DUCT, SEE PLANS FOR S1ZE W SPIN —IN FITTING WITH SCOOP AND BALANCING DAMPER AS MANUFACTURED BY CREATIVE METALS, INC. OR APPROVED EQUAL. RUNOUT CONNECTION DETAIL NO SCAL^ 2" FLEXIBLE DUCT— SEE PLAN FOR SIZE TIGHTLY TAPE TWO WRAPS PRIOR TO INSTALLING STRAP DUCT OR EQUIP. COLLAR ® 1" WIDE X 20 GA. STRAP WITH TIGHTENING SCREW OUTER EDGE OF COLLAR SECURE STRAP WITH SHEET METAL SCREWS 3"OC MAX FLEX DUCT CONNECTION DETAIL NO SCALE FASTEN FLEX WITH PANDUIT STRAPS 3" MINIMUM EXTENSION FLUSH MOUNTED, OPPOSED BLADE, RADIAL DAMPER (PER SCHEDULE) DIFFUSER F-I F_X DUCT CONNECTION TO RUCTION -USER DETAIL egulafions aLE �{VT�'lmAp)(wAaL DATE: \ 09/17/19 ANGLE IRON 1/2" SCREEN 135' MIN. DUCT WITH WATERPROOF R SEAMS AND ` JOINTS TREATED R=W/2 WOOD NAILER WOOD CONTINUOUS 12. BASE FLASHING 18" SEAL MIN. MIN. FIBER CANT STRIP 2"x4" TREATED 14" WOOD NAILER MIN. ROOFING DUCT GOOSENECK TERMINATION DETAIL ROOF TOP PACKAGED A/C UNIT BY GASKET SEALER BY M.C. 2x4 WOOD NAILER BY G.C. — INSULATION BY G.C. ROOF OONECTIUUSING TRUN DECK UNDER UNIT EXCEPT AT DUCT OPENINGS A/C UNIT ROOFTOP CURB DETAIL NO SCALE NUMBERED NOTES OThermostat on wall at +60" ASS, verify mounting height with tenant and architect prior to install. Ora Ceiling exhaust fan, see schedule on sheet M1. Suspend fan from structure with vibration isolation. Fan shall run continuously during occupied hours. ODo not run ducts or piping over electric panels. OGas -electric roof top unit level on roof curb, see schedule on sheet M100. Verify exact location with structure. Follow all manufacturer's installation instructions and clearances, including minimum 10'-0" from outside air intake to any exhaust. Run condensate towards roof drains, a minimum of 10'-0" from unit, see detail this sheet. Do not splash at curb. OTerminate exhaust duct at gooseneck, 18" above roof with birdscreen. Maintain minimum 10'-0" distance from any outside air intake. Coordinate exact location with structure and intakes. OReturn duct type smoke detectors factory installed by There. Remote multi -signal devices shall be installed and wired by MC. Verify location of remote test/reset switches with inspector. OTerminate dud open above ceiling with hardware screen. Return air via plenum above ceiling. MC shall remove all combustible material in plenum. Report problems to engineer. NOTES: Coordinate equipment locations and Flashing and weatherproofing with general contractor and with structure. DUCT ELBOW NOTES ALL 90 DEGREE TURNS MUST EITHER BE MITERED ELBOWS WITH TURNING VANES PER SMACNA: OR, SMOOTH RADIUS w ELBOWS (R/W=1.0): ` � R OTHER TYPES OF ELBOWS, INCLUDING THOSE LISTED BELOW ARE NOT PERMITTED: MITERED ELBOW WITHOUT VANES: 3 SEE GENERAL NOTES ON SHEET M7 FOR ADDITIONAL INFORMATION. MECHANICAL PLAN M200 1/4' = 1'0" C HA CRAIG BENNETT ASSOCIATES ARCHITECTS TENANT MY EYE DR 1950 OLD GALLOWS RD SUITE 520 VIENNA, VIRGINIA 20182 703-847-8899 FAX 866-414-6476 Contact: Suzanne Berardi —Gould 571-455-8191 ARCHITECT: CBA ARCHITECTS, PC 1239 PINE HILL ROAD MCLEAN, VIRGINIA 22101 703-847-6900 FAX 847-6955 www.cba—urchiiecis.com Contact: Craig Bennett cbenneit@cba—architecis.com 703-975-2400 MEP ENGINEER: DWYER ENGINEERING 552 FORT EVANS ROAD NE, #200 LEESBURG, VIRGINIA 20176 703-777-5988 FAX 703-439-2588 www.dwyer.com Contact: Brian Davis BDavis@dwyer.com 703-777-5988 EXT. 110 MY EYE DR SHOPPES ON MAIN SOUTHWEST CORNER OF MAIN ST & GRAND AVE CARMEL, INDIANA For Permit 07/18/19 For Review 07/03/19 No. 11 0 0 SA O fill v Wo ode MECHANICAL PLAN SHEET M200