HomeMy WebLinkAboutM200_Mechanical Planr
RELEASED FOR CONS]
Subject to compliance with all
of State and Local Cot
City of Carmel
ROOFTOP
A/C UNIT
FLEXIBLE CONNECTION GASKET
FULL SIZE OF UNIT
CONNECTION
TOP OF CURB MUST
BE SET DEAD LEVEL
RIGID INSULATION
CANT STRIP--- ROOFING
DECK
ROOF JOIST
FRAME AROUND
OPENING PER
STRUCTURAL
DETAIL
HOLD TOP OF DUCTWORK CEILING
AS TIGHT AS POSSIBLE
TO BOTTOM OF JOIST DUCT— SEE PLAN FOR
FIELD VERIFY SIZE AND ROUTING
RTU MOUNTING DETAIL
NO SCALE
DUCT
w SPIN —IN FITTING
w BALANCING
DAMPER WITH
LOCKING
QUADRANT
*TRUNK
EXTRACTOR
BRANCH DUCT, SEE
PLANS FOR S1ZE
W SPIN —IN FITTING WITH SCOOP AND BALANCING DAMPER
AS MANUFACTURED BY CREATIVE METALS,
INC.
OR APPROVED EQUAL.
RUNOUT CONNECTION
DETAIL
NO SCAL^
2"
FLEXIBLE DUCT— SEE
PLAN FOR SIZE
TIGHTLY TAPE TWO
WRAPS PRIOR TO
INSTALLING STRAP
DUCT OR EQUIP.
COLLAR
®
1" WIDE X 20 GA.
STRAP WITH
TIGHTENING SCREW
OUTER EDGE OF
COLLAR
SECURE STRAP
WITH SHEET METAL
SCREWS 3"OC MAX
FLEX
DUCT
CONNECTION
DETAIL
NO SCALE
FASTEN FLEX WITH
PANDUIT STRAPS
3" MINIMUM EXTENSION
FLUSH MOUNTED, OPPOSED
BLADE, RADIAL DAMPER
(PER SCHEDULE)
DIFFUSER
F-I F_X DUCT CONNECTION TO
RUCTION -USER DETAIL
egulafions aLE
�{VT�'lmAp)(wAaL
DATE: \ 09/17/19
ANGLE IRON
1/2" SCREEN
135'
MIN.
DUCT WITH
WATERPROOF
R
SEAMS AND
`
JOINTS
TREATED
R=W/2
WOOD NAILER
WOOD
CONTINUOUS 12.
BASE FLASHING
18"
SEAL MIN.
MIN.
FIBER CANT
STRIP
2"x4" TREATED
14"
WOOD NAILER
MIN.
ROOFING
DUCT
GOOSENECK TERMINATION
DETAIL
ROOF TOP PACKAGED A/C UNIT BY
GASKET SEALER BY M.C.
2x4 WOOD NAILER
BY G.C. —
INSULATION BY G.C.
ROOF
OONECTIUUSING
TRUN DECK
UNDER UNIT EXCEPT
AT DUCT OPENINGS
A/C UNIT ROOFTOP
CURB DETAIL
NO SCALE
NUMBERED NOTES
OThermostat on wall at +60" ASS, verify mounting height with tenant and architect prior to install.
Ora Ceiling exhaust fan, see schedule on sheet M1. Suspend fan from structure with vibration isolation.
Fan shall run continuously during occupied hours.
ODo not run ducts or piping over electric panels.
OGas -electric roof top unit level on roof curb, see schedule on sheet M100. Verify exact location with
structure. Follow all manufacturer's installation instructions and clearances, including minimum
10'-0" from outside air intake to any exhaust. Run condensate towards roof drains, a minimum of
10'-0" from unit, see detail this sheet. Do not splash at curb.
OTerminate exhaust duct at gooseneck, 18" above roof with birdscreen. Maintain minimum 10'-0"
distance from any outside air intake. Coordinate exact location with structure and intakes.
OReturn duct type smoke detectors factory installed by There. Remote multi -signal devices shall be
installed and wired by MC. Verify location of remote test/reset switches with inspector.
OTerminate dud open above ceiling with hardware screen. Return air via plenum above ceiling. MC
shall remove all combustible material in plenum. Report problems to engineer.
NOTES:
Coordinate equipment locations and Flashing and weatherproofing with general contractor and
with structure.
DUCT ELBOW NOTES
ALL 90 DEGREE TURNS
MUST EITHER BE MITERED
ELBOWS WITH TURNING
VANES PER SMACNA:
OR, SMOOTH RADIUS w
ELBOWS (R/W=1.0): ` � R
OTHER TYPES OF ELBOWS,
INCLUDING THOSE LISTED
BELOW ARE NOT
PERMITTED:
MITERED ELBOW WITHOUT
VANES: 3
SEE GENERAL NOTES ON
SHEET M7 FOR ADDITIONAL
INFORMATION.
MECHANICAL PLAN
M200 1/4' = 1'0"
C HA
CRAIG
BENNETT
ASSOCIATES
ARCHITECTS
TENANT
MY EYE DR
1950 OLD GALLOWS RD
SUITE 520
VIENNA, VIRGINIA 20182
703-847-8899 FAX 866-414-6476
Contact: Suzanne Berardi —Gould
571-455-8191
ARCHITECT:
CBA ARCHITECTS, PC
1239 PINE HILL ROAD
MCLEAN, VIRGINIA 22101
703-847-6900 FAX 847-6955
www.cba—urchiiecis.com
Contact: Craig Bennett
cbenneit@cba—architecis.com
703-975-2400
MEP ENGINEER:
DWYER ENGINEERING
552 FORT EVANS ROAD NE, #200
LEESBURG, VIRGINIA 20176
703-777-5988 FAX 703-439-2588
www.dwyer.com
Contact: Brian Davis
BDavis@dwyer.com
703-777-5988 EXT. 110
MY EYE DR
SHOPPES ON MAIN
SOUTHWEST CORNER OF
MAIN ST & GRAND AVE
CARMEL, INDIANA
For Permit 07/18/19
For Review 07/03/19
No. 11 0 0
SA O
fill
v Wo
ode
MECHANICAL
PLAN
SHEET