HomeMy WebLinkAboutI38108261.6_Cooper_Run16023 Swingley Ridge Rd Chesterfield, MO 63017 314-434-1200 MiTek USA, Inc. Re: The truss drawing(s) referenced below have been prepared by MiTek USA, Inc. under my direct supervision based on the parameters provided by ProBuild (CarterLee Bldg Components). August 9,2019 Liu, Xuegang Pages or sheets covered by this seal: I38108261 thru I38108324 My license renewal date for the state of Indiana is July 31, 2020. 6_Cooper_Run 6 Cooper Run IMPORTANT NOTE: The seal on these truss component designs is a certification that the engineer named is licensed in the jurisdiction(s) identified and that the designs comply with ANSI/TPI 1. These designs are based upon parameters shown (e.g., loads, supports, dimensions, shapes and design codes), which were given to MiTek or TRENCO. Any project specific information included is for MiTek's or TRENCO's customers file reference purpose only, and was not taken into account in the preparation of these designs. MiTek or TRENCO has not independently verified the applicability of the design parameters or the designs for any particular building. Before use, the building designer should verify applicability of design parameters and properly incorporate these designs into the overall building design per ANSI/TPI 1, Chapter 2. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 6_Cooper_Run Truss GE01 Truss Type GABLE Qty 1 Ply 1 6 Cooper Run Job Reference (optional) I38108261 8.240 s Jul 14 2019 MiTek Industries, Inc. Fri Aug 9 10:19:25 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:VarUFZKVo2kjotTWURxEQNyoteT-QW3NA_91o2rDP9gEBV43lYYIj9bAOtbJ?g3UsbypcQ0 Scale = 1:37.9 Sheet Front Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 9 10 11 12 13 22 21 20 19 18 17 16 15 14 3x6 2x4 4x6 3x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 11-7-8 11-7-8 -1-0-0 1-0-0 5-9-12 5-9-12 11-7-8 5-9-12 12-7-8 1-0-0 1-3-06-1-21-3-010.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-R 0.14 0.06 0.13 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.01 -0.01 0.00 (loc) 13 13 14 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 143 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 6-0-0 oc bracing. REACTIONS.All bearings 11-7-8. (lb) - Max Horz 22=148(LC 5) Max Uplift All uplift 100 lb or less at joint(s) 22, 14, 19, 20, 17, 16, 15 except 21=-103(LC 5) Max Grav All reactions 250 lb or less at joint(s) 22, 14, 18, 19, 20, 21, 17, 16, 15 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(12-13) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 6) Gable studs spaced at 1-4-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 22, 14, 19, 20, 17, 16, 15 except (jt=lb) 21=103. 11) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 12) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 13) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 9,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 6_Cooper_Run Truss GE02 Truss Type GABLE Qty 1 Ply 1 6 Cooper Run Job Reference (optional) I38108262 8.240 s Jul 14 2019 MiTek Industries, Inc. Fri Aug 9 10:19:26 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:VarUFZKVo2kjotTWURxEQNyoteT-uicmNKAfZMz40IFQlDbIIm4LcYmu7CUTEKo2P2ypcQ? Scale = 1:62.0 Sheet Front Right Option 6-2-6 1 Ply 7/16OSB8 1 2 3 4 5 6 16 15 14 12 11 10 9 8 713 3x4 4x6 3x8 3x8 3x4 3x4 4x6 3x6 3x4 2x4 2x4 2x4 2x4 3x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 9-6-0 9-6-0 11-7-8 2-1-8 12-9-10 1-2-2 19-0-0 6-2-6 4-10-4 4-10-4 5-7-13 0-9-9 9-6-0 3-10-3 14-1-12 4-7-12 19-0-0 4-10-4 20-0-0 1-0-0 1-3-09-2-01-3-010.00 12 Plate Offsets (X,Y)-- [18:0-1-11,0-0-0], [19:0-1-10,0-0-12], [19:0-0-6,0-0-1], [27:0-1-9,0-1-0], [29:0-1-9,0-1-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-SH 0.64 0.67 0.67 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.19 -0.48 0.02 (loc) 14-16 14-16 7 l/defl >725 >281 n/a L/d 240 180 n/a PLATES MT20 Weight: 227 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 1-16,5-7: 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 7-8-0 except (jt=length) 16=0-3-8, 13=0-3-8. (lb) - Max Horz 16=-231(LC 4) Max Uplift All uplift 100 lb or less at joint(s) 16, 7, 12, 11 except 13=-126(LC 2) Max Grav All reactions 250 lb or less at joint(s) 12, 11, 10, 9, 8, 13 except 16=724(LC 1), 7=747(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-259/78, 2-3=-609/134, 3-4=-608/133, 5-7=-274/161 BOT CHORD 14-16=-63/512, 13-14=0/500, 12-13=0/500, 11-12=0/500, 10-11=0/500, 9-10=0/500, 8-9=0/500, 7-8=0/500 WEBS 3-14=-78/446, 2-16=-545/41, 4-7=-606/0 NOTES-(10-11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable studs spaced at 1-4-0 oc. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 16, 7, 12, 11 except (jt=lb) 13=126. 9) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 9,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 6_Cooper_Run Truss GE03 Truss Type GABLE Qty 1 Ply 1 6 Cooper Run Job Reference (optional) I38108263 8.240 s Jul 14 2019 MiTek Industries, Inc. Fri Aug 9 10:19:28 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:VarUFZKVo2kjotTWURxEQNyoteT-q5kWo0Cv5zDoGcPotedmNBAoEMbsbDJmieH8SwypcPz Scale = 1:61.4 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 3736 35 34 33 32 31 30 29 28 27 26 25 24 23 22 2120 3x4 3x4 4x6 3x4 3x4 3x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 19-11-0 19-11-0 -1-0-0 1-0-0 9-11-8 9-11-8 19-11-0 9-11-8 20-11-0 1-0-0 1-3-09-6-91-3-010.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-R 0.25 0.12 0.20 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.01 0.00 (loc) 19 19 20 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 116 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 6-0-0 oc bracing. WEBS 1 Row at midpt 10-28 REACTIONS.All bearings 19-11-0. (lb) - Max Horz 37=229(LC 5) Max Uplift All uplift 100 lb or less at joint(s) 29, 30, 31, 32, 34, 35, 26, 25, 24, 23, 22 except 37=-301(LC 4), 20=-242(LC 5), 36=-305(LC 5), 21=-262(LC 4) Max Grav All reactions 250 lb or less at joint(s) 28, 29, 30, 31, 32, 34, 35, 27, 26, 25, 24, 23, 22, 21 except 37=377(LC 5), 20=319(LC 4), 36=254(LC 4) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 9-10=-26/252, 10-11=-26/252 WEBS 10-28=-257/0 NOTES-(12-13) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 6) Gable studs spaced at 1-4-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 29, 30, 31, 32, 34, 35, 26, 25, 24, 23, 22 except (jt=lb) 37=301, 20=242, 36=305, 21=262. 11) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 12) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 13) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 9,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 6_Cooper_Run Truss GE04 Truss Type GABLE Qty 1 Ply 1 6 Cooper Run Job Reference (optional) I38108264 8.240 s Jul 14 2019 MiTek Industries, Inc. Fri Aug 9 10:19:29 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:VarUFZKVo2kjotTWURxEQNyoteT-JHIu0MCXsHMftm_?QL9?vOirbmuhKjevwI1i_NypcPy Scale = 1:18.8 Sheet Front Full Sheathing 1 Ply 7/16OSB8 1 2 3 5 4 3x6 3x6 2x4 2x4 2x4 2x4 2x4 2x4 3x8 -1-0-0 1-0-0 7-4-0 7-4-0 0-8-82-10-32-6-110-3-82-10-33.50 12 Plate Offsets (X,Y)-- [4:0-3-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-R 0.72 0.28 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.15 -0.24 0.00 (loc) 4-5 4-5 4 l/defl >553 >351 n/a L/d 240 180 n/a PLATES MT20 Weight: 50 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)5=356/0-3-8, 4=276/0-1-9 Max Horz 5=86(LC 5) Max Uplift 5=-116(LC 4), 4=-88(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-5=-303/168 NOTES-(11-12) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed; porch left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) Gable studs spaced at 1-4-0 oc. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 7) Bearing at joint(s) 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 4. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4 except (jt=lb) 5=116. 10) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 9,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 6_Cooper_Run Truss GE05 Truss Type GABLE Qty 1 Ply 1 6 Cooper Run Job Reference (optional) I38108265 8.240 s Jul 14 2019 MiTek Industries, Inc. Fri Aug 9 10:19:30 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:VarUFZKVo2kjotTWURxEQNyoteT-nUsGDiDAdaUWVwZB_3gEScFAwAIl39o39ymFXpypcPx Scale = 1:41.2 Sheet Front Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 33 32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 2x4 2x4 4x6 2x4 2x4 3x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 19-7-0 19-7-0 -1-0-0 1-0-0 9-9-8 9-9-8 19-7-0 9-9-8 20-7-0 1-0-0 0-11-05-9-120-11-06.00 12 Plate Offsets (X,Y)-- [29:0-1-8,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-R 0.11 0.03 0.07 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.01 0.00 (loc) 17 17 18 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 216 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 6-0-0 oc bracing. REACTIONS.All bearings 19-7-0. (lb) - Max Horz 33=-63(LC 4) Max Uplift All uplift 100 lb or less at joint(s) 33, 18, 26, 27, 28, 30, 31, 32, 24, 23, 22, 21, 20, 19 Max Grav All reactions 250 lb or less at joint(s) 33, 18, 25, 26, 27, 28, 30, 31, 32, 24, 23, 22, 21, 20, 19 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(12-13) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 6) Gable studs spaced at 1-4-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 33, 18, 26, 27, 28, 30, 31, 32, 24, 23, 22, 21, 20, 19. 11) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 12) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 13) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 9,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 6_Cooper_Run Truss GE06 Truss Type GABLE Qty 1 Ply 1 6 Cooper Run Job Reference (optional) I38108266 8.240 s Jul 14 2019 MiTek Industries, Inc. Fri Aug 9 10:19:31 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:VarUFZKVo2kjotTWURxEQNyoteT-FgQeQ1EoOucN747NYmBT?poKsZdIodgCOcWp3FypcPw Scale = 1:16.2 Sheet Front Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 9 8 7 6 3x6 2x4 2x4 2x4 2x4 2x4 2x4 -1-0-0 1-0-0 6-0-0 6-0-0 0-8-82-5-83.50 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-R 0.10 0.08 0.03 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.00 0.00 0.00 (loc) 1 1 6 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 38 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 6-0-0. (lb) - Max Horz 9=74(LC 5) Max Uplift All uplift 100 lb or less at joint(s) 9, 6, 7, 8 Max Grav All reactions 250 lb or less at joint(s) 9, 6, 7, 8 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(11-12) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) Gable requires continuous bottom chord bearing. 4) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 5) Gable studs spaced at 1-4-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 9, 6, 7, 8. 10) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 9,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 6_Cooper_Run Truss GE07 Truss Type Monopitch Supported Gable Qty 1 Ply 1 6 Cooper Run Job Reference (optional) I38108267 8.240 s Jul 14 2019 MiTek Industries, Inc. Fri Aug 9 10:19:31 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:VarUFZKVo2kjotTWURxEQNyoteT-FgQeQ1EoOucN747NYmBT?poKuZeEod8COcWp3FypcPw Scale = 1:9.3 Sheet Front Full Sheathing 1 Ply 7/16OSB8 1 2 3 5 4 3x6 2x4 2x4 -1-0-0 1-0-0 2-0-0 2-0-0 0-8-81-3-83.50 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-R 0.09 0.02 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.00 -0.00 0.00 (loc) 1 1 4 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 11 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 2-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)5=160/2-0-0, 4=45/2-0-0 Max Horz 5=35(LC 5) Max Uplift 5=-50(LC 4), 4=-5(LC 5) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(11-12) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) Gable requires continuous bottom chord bearing. 4) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 5) Gable studs spaced at 2-0-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 4. 10) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 9,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 6_Cooper_Run Truss J01 Truss Type Jack-Open Qty 23 Ply 1 6 Cooper Run Job Reference (optional) I38108268 8.240 s Jul 14 2019 MiTek Industries, Inc. Fri Aug 9 10:19:32 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:VarUFZKVo2kjotTWURxEQNyoteT-js_1eNFQ9CkElDia6UiiX1KQkzxlX4OLcGFMbiypcPv Scale = 1:26.0 1 2 5 3 4 3x4 3x4 4-0-0 4-0-0 -1-0-0 1-0-0 4-0-0 4-0-0 1-3-04-7-04-1-34-7-010.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-R 0.41 0.19 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.02 -0.03 -0.04 (loc) 4-5 4-5 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 13 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)5=231/0-3-8, 3=99/Mechanical, 4=42/Mechanical Max Horz 5=155(LC 6) Max Uplift 3=-79(LC 6), 4=-4(LC 6) Max Grav 5=231(LC 1), 3=99(LC 1), 4=73(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8-9) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 4. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 9,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 6_Cooper_Run Truss J02 Truss Type Jack-Open Qty 5 Ply 1 6 Cooper Run Job Reference (optional) I38108269 8.240 s Jul 14 2019 MiTek Industries, Inc. Fri Aug 9 10:19:32 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:VarUFZKVo2kjotTWURxEQNyoteT-js_1eNFQ9CkElDia6UiiX1KSgzxqX4OLcGFMbiypcPv Scale = 1:26.0 1 2 3 8 7 6 4 5 3x4 3x6 2x4 3x4 3x4 2-3-8 2-3-8 4-0-0 1-8-8 -1-0-0 1-0-0 2-3-8 2-3-8 4-0-0 1-8-8 1-3-02-11-04-7-03-11-04-1-30-8-010.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-R 0.28 0.18 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.02 -0.03 -0.03 (loc) 7 7 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 15 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)8=231/0-3-8, 4=88/Mechanical, 5=54/Mechanical Max Horz 8=197(LC 6) Max Uplift 4=-62(LC 6), 5=-36(LC 6) Max Grav 8=231(LC 1), 4=88(LC 1), 5=62(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8-9) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4, 5. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 9,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 6_Cooper_Run Truss J03 Truss Type Jack-Open Qty 6 Ply 1 6 Cooper Run Job Reference (optional) I38108270 8.240 s Jul 14 2019 MiTek Industries, Inc. Fri Aug 9 10:19:33 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:VarUFZKVo2kjotTWURxEQNyoteT-B3YPrjG2wVs5MNHmfBDx4EtfLNJ?GWdVrw?v88ypcPu Scale = 1:15.1 1 2 5 3 42x4 3x4 2-0-0 2-0-0 -1-0-0 1-0-0 2-0-0 2-0-0 1-1-02-5-01-11-132-5-08.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-R 0.16 0.06 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.00 -0.00 (loc) 5 4-5 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 7 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 2-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)5=164/0-3-8, 3=37/Mechanical, 4=15/Mechanical Max Horz 5=84(LC 6) Max Uplift 5=-11(LC 6), 3=-31(LC 6), 4=-6(LC 6) Max Grav 5=164(LC 1), 3=37(LC 1), 4=34(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8-9) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 3, 4. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 9,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 6_Cooper_Run Truss J04 Truss Type Jack-Open Structural Gable Qty 2 Ply 1 6 Cooper Run Job Reference (optional) I38108271 8.240 s Jul 14 2019 MiTek Industries, Inc. Fri Aug 9 10:19:34 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:VarUFZKVo2kjotTWURxEQNyoteT-fF5n33Gghp_x_XsyDukAcSPqmnfc?zte4akTgaypcPt Scale = 1:14.9 1 2 5 3 4 2x4 3x4 2-3-13 2-3-13 -1-5-5 1-5-5 2-3-13 2-3-13 1-2-02-4-81-11-122-4-86.25 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-R 0.18 0.04 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.00 -0.00 (loc) 4-5 4-5 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 8 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 2-3-13 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)3=35/Mechanical, 5=216/0-5-10, 4=14/Mechanical Max Horz 5=55(LC 6) Max Uplift 3=-21(LC 6), 5=-46(LC 6) Max Grav 3=35(LC 1), 5=216(LC 1), 4=38(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(10-11) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) Gable studs spaced at 2-0-0 oc. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 7) Refer to girder(s) for truss to truss connections. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 5. 9) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 9,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 6_Cooper_Run Truss J05 Truss Type Jack-Open Structural Gable Qty 1 Ply 1 6 Cooper Run Job Reference (optional) I38108272 8.240 s Jul 14 2019 MiTek Industries, Inc. Fri Aug 9 10:19:34 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:VarUFZKVo2kjotTWURxEQNyoteT-fF5n33Gghp_x_XsyDukAcSPqmnfc?zte4akTgaypcPt Scale = 1:14.9 1 2 5 3 4 2x4 3x4 2-3-13 2-3-13 -1-5-5 1-5-5 2-3-13 2-3-13 1-2-02-4-81-11-122-4-86.25 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-R 0.18 0.04 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.00 -0.00 (loc) 4-5 4-5 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 8 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 2-3-13 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)3=35/Mechanical, 5=216/0-5-10, 4=14/Mechanical Max Horz 5=55(LC 6) Max Uplift 3=-21(LC 6), 5=-46(LC 6) Max Grav 3=35(LC 1), 5=216(LC 1), 4=38(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(10-11) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) Gable studs spaced at 2-0-0 oc. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 7) Refer to girder(s) for truss to truss connections. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 5. 9) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 9,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 6_Cooper_Run Truss J06 Truss Type Jack-Open Structural Gable Qty 1 Ply 1 6 Cooper Run Job Reference (optional) I38108273 8.240 s Jul 14 2019 MiTek Industries, Inc. Fri Aug 9 10:19:35 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:VarUFZKVo2kjotTWURxEQNyoteT-7Rf9GPHIR76ochR9ncFP9fy_5B?lkQ7oJEU0C0ypcPs Scale = 1:13.6 1 2 5 3 4 2x4 3x4 2-0-1 1-11-0 -1-6-13 1-6-13 2-0-1 2-0-1 1-2-02-1-81-8-142-1-85.74 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-R 0.21 0.04 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.00 -0.00 (loc) 5 5 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 8 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 2-0-1 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)3=16/Mechanical, 5=223/0-6-2, 4=8/Mechanical Max Horz 5=47(LC 6) Max Uplift 3=-14(LC 5), 5=-59(LC 6) Max Grav 3=16(LC 1), 5=223(LC 1), 4=31(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(10-11) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) Gable studs spaced at 2-0-0 oc. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 7) Refer to girder(s) for truss to truss connections. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 5. 9) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 9,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 6_Cooper_Run Truss J07 Truss Type Jack-Open Qty 2 Ply 1 6 Cooper Run Job Reference (optional) I38108274 8.240 s Jul 14 2019 MiTek Industries, Inc. Fri Aug 9 10:19:35 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:VarUFZKVo2kjotTWURxEQNyoteT-7Rf9GPHIR76ochR9ncFP9fy?EB?hkQ7oJEU0C0ypcPs Scale = 1:13.8 1 2 5 3 42x4 2x4 2-0-0 2-0-0 -1-0-0 1-0-0 2-0-0 2-0-0 1-0-02-2-01-9-12-2-07.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-R 0.14 0.05 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.00 -0.00 (loc) 5 4-5 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 7 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 2-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)5=164/0-3-8, 3=37/Mechanical, 4=15/Mechanical Max Horz 5=74(LC 6) Max Uplift 5=-20(LC 6), 3=-26(LC 6), 4=-2(LC 6) Max Grav 5=164(LC 1), 3=37(LC 1), 4=34(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8-9) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 3, 4. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 9,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 6_Cooper_Run Truss M01 Truss Type MONOPITCH Qty 4 Ply 1 6 Cooper Run Job Reference (optional) I38108275 8.240 s Jul 14 2019 MiTek Industries, Inc. Fri Aug 9 10:19:36 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:VarUFZKVo2kjotTWURxEQNyoteT-bdDXUlIwCQEfDr0LLJneitV4_aIVTtNxXuDZkTypcPr Scale = 1:17.0 1 2 3 5 4 3x4 3x6 3x8 -1-0-0 1-0-0 6-4-0 6-4-0 0-8-82-6-112-3-30-3-82-6-113.50 12 Plate Offsets (X,Y)-- [4:0-3-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-R 0.52 0.20 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.08 -0.13 0.00 (loc) 4-5 4-5 4 l/defl >873 >559 n/a L/d 240 180 n/a PLATES MT20 Weight: 18 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)5=317/0-3-8, 4=235/0-1-8 Max Horz 5=77(LC 5) Max Uplift 5=-105(LC 4), 4=-75(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-5=-271/157 NOTES-(9-10) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed; porch left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 5) Bearing at joint(s) 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 4. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4 except (jt=lb) 5=105. 8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 9,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 6_Cooper_Run Truss M02 Truss Type Monopitch Qty 5 Ply 1 6 Cooper Run Job Reference (optional) I38108276 8.240 s Jul 14 2019 MiTek Industries, Inc. Fri Aug 9 10:19:36 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:VarUFZKVo2kjotTWURxEQNyoteT-bdDXUlIwCQEfDr0LLJneitV89aJSTtNxXuDZkTypcPr Scale = 1:15.6 1 2 3 5 4 3x4 3x6 3x6 5-4-0 5-4-0 -1-0-0 1-0-0 5-4-0 5-4-0 0-8-82-3-31-11-110-3-82-3-33.50 12 Plate Offsets (X,Y)-- [4:Edge,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-R 0.32 0.14 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.02 -0.06 0.00 (loc) 4-5 4-5 4 l/defl >999 >970 n/a L/d 240 180 n/a PLATES MT20 Weight: 15 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-4-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)5=278/0-3-8, 4=194/0-1-8 Max Horz 5=67(LC 5) Max Uplift 5=-52(LC 4), 4=-19(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(9-10) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 5) Bearing at joint(s) 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 4. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 4. 8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 9,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 6_Cooper_Run Truss M03 Truss Type Monopitch Qty 9 Ply 1 6 Cooper Run Job Reference (optional) I38108277 8.240 s Jul 14 2019 MiTek Industries, Inc. Fri Aug 9 10:19:37 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:VarUFZKVo2kjotTWURxEQNyoteT-4qnwh5JZzkMWr?bXu1ItE41I6_fvCKd5mYz7HvypcPq Scale = 1:16.6 1 2 3 5 4 3x6 2x4 3x6 6-0-0 6-0-0 -1-0-0 1-0-0 6-0-0 6-0-0 0-8-82-5-83.50 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-R 0.37 0.19 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.04 -0.11 0.00 (loc) 4-5 4-5 4 l/defl >999 >602 n/a L/d 240 180 n/a PLATES MT20 Weight: 17 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-5: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)4=223/Mechanical, 5=306/0-3-8 Max Horz 5=74(LC 5) Max Uplift 4=-23(LC 6), 5=-53(LC 4) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-5=-260/153 NOTES-(8-9) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4, 5. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 9,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 6_Cooper_Run Truss T01 Truss Type Hip Qty 1 Ply 1 6 Cooper Run Job Reference (optional) I38108278 8.240 s Jul 14 2019 MiTek Industries, Inc. Fri Aug 9 10:19:38 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:VarUFZKVo2kjotTWURxEQNyoteT-Y0LIuRJBk2UNT8AjSkp6nIaNGOsrxcHE?CigpLypcPp Scale = 1:65.6 1 2 3 4 5 6 7 8 9 10 11 12 24 23 22 21 20 19 18 17 16 15 14 1325 5x8 3x6 5x8 3x4 3x6 2x4 2x4 5x12 3x6 2x4 2x4 3x6 3x8 3x4 5x12 3x4 3x4 6x10 6x6 4x6 4x6 4x8 3-11-12 3-11-12 7-9-0 3-9-4 15-1-12 7-4-12 22-6-8 7-4-12 28-2-0 5-7-8 33-7-8 5-5-8 34-8-0 1-0-8 35-11-0 1-3-0 -1-0-0 1-0-0 3-11-12 3-11-12 7-9-0 3-9-4 15-1-12 7-4-12 22-6-8 7-4-12 28-2-0 5-7-8 33-7-8 5-5-8 34-8-0 1-0-8 35-11-0 1-3-0 36-11-0 1-0-0 1-1-06-3-01-1-00-8-06-3-08.00 12 Plate Offsets (X,Y)-- [2:0-3-0,0-1-12], [4:0-5-12,0-2-0], [8:0-5-12,0-2-0], [11:0-2-14,0-2-0], [16:0-6-8,0-3-12], [18:0-6-0,0-2-0], [23:0-2-8,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-SH 0.72 0.66 0.74 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.16 -0.47 0.19 (loc) 20-21 19-20 13 l/defl >999 >902 n/a L/d 240 180 n/a PLATES MT20 Weight: 153 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-24,11-13: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-5-8 oc purlins, except end verticals, and 2-0-0 oc purlins (3-1-2 max.): 4-8. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)24=1572/0-3-8, 13=1519/0-3-8 Max Horz 24=150(LC 5) Max Uplift 24=-74(LC 5), 13=-74(LC 4) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1886/178, 3-4=-1938/222, 4-5=-2235/278, 5-7=-2330/286, 7-8=-2332/284, 8-9=-2110/211, 9-10=-2479/195, 10-11=-1161/116, 2-24=-1515/175, 11-13=-1461/159 BOT CHORD 21-23=-192/1508, 20-21=-185/1569, 17-18=-82/1677, 16-17=-128/2193 WEBS 7-18=-400/169, 3-23=-288/56, 4-20=-190/907, 5-20=-571/229, 18-20=-254/2162, 8-18=-213/954, 8-17=0/303, 9-17=-535/136, 14-16=-21/1152, 10-16=-147/1596, 10-14=-1457/49, 2-23=-59/1412, 11-14=-31/991 NOTES-(10-11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 24, 13. 8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 9,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 6_Cooper_Run Truss T02 Truss Type Hip Qty 1 Ply 1 6 Cooper Run Job Reference (optional) I38108279 8.240 s Jul 14 2019 MiTek Industries, Inc. Fri Aug 9 10:19:40 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:VarUFZKVo2kjotTWURxEQNyoteT-UPT2J6LRGfk5iSK6a9rasjfgnCVFPXMXSWBntEypcPn Scale = 1:65.5 1 2 3 4 5 6 7 8 9 10 11 23 22 21 20 19 18 17 16 15 14 13 1224 5x6 6x6 3x4 3x6 2x4 2x4 5x8 3x6 2x4 2x4 3x6 3x8 3x4 5x8 3x4 3x4 6x10 6x6 5x6 4x6 4x8 5-2-12 5-2-12 10-3-0 5-0-4 16-4-12 6-1-12 22-6-8 6-1-12 25-8-0 3-1-8 33-7-8 7-11-8 34-8-0 1-0-8 35-11-0 1-3-0 -1-0-0 1-0-0 5-2-12 5-2-12 10-3-0 5-0-4 16-4-12 6-1-12 22-6-8 6-1-12 25-8-0 3-1-8 33-7-8 7-11-8 34-8-0 1-0-8 35-11-0 1-3-0 36-11-0 1-0-0 1-1-07-11-01-1-00-8-07-11-08.00 12 Plate Offsets (X,Y)-- [2:0-3-0,0-1-12], [4:0-4-4,0-2-4], [7:0-3-0,0-2-3], [10:0-2-14,0-2-0], [15:0-6-12,0-3-12], [17:0-2-12,0-2-0], [22:0-2-8,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-SH 0.92 0.85 0.64 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.18 -0.52 0.19 (loc) 15-16 15-16 12 l/defl >999 >824 n/a L/d 240 180 n/a PLATES MT20 Weight: 164 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-23,10-12: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals, and 2-0-0 oc purlins (4-0-7 max.): 4-7. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 5-17, 8-16 REACTIONS.(lb/size)23=1574/0-3-8, 12=1532/0-3-8 Max Horz 23=189(LC 5) Max Uplift 23=-66(LC 6), 12=-66(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1984/181, 3-4=-1868/231, 4-5=-1788/255, 5-6=-1783/247, 6-7=-1784/246, 7-8=-2038/205, 8-9=-2544/205, 9-10=-1166/109, 2-23=-1514/175, 10-12=-1477/155 BOT CHORD 20-22=-159/1579, 19-20=-135/1484, 16-17=-16/1576, 15-16=-196/2370 WEBS 6-17=-271/135, 4-20=-8/310, 4-19=-155/564, 5-19=-446/198, 17-19=-147/1754, 7-17=-198/604, 7-16=0/380, 8-16=-810/253, 13-15=0/1129, 9-15=-252/1835, 9-13=-1416/7, 2-22=-33/1418, 10-13=-6/960 NOTES-(10-11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 23, 12. 8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 9,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 6_Cooper_Run Truss T03 Truss Type Hip Qty 1 Ply 1 6 Cooper Run Job Reference (optional) I38108280 8.240 s Jul 14 2019 MiTek Industries, Inc. Fri Aug 9 10:19:41 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:VarUFZKVo2kjotTWURxEQNyoteT-yb0QXSM31zsyKcuI7tMpPwCt1bvq8_yghAxKQgypcPm Scale = 1:70.5 1 2 3 4 5 6 7 8 9 10 11 12 13 14 26 25 24 23 22 21 20 19 18 17 16 1527 3x6 5x6 5x6 6x8 3x4 3x6 2x4 2x4 8x8 3x6 2x4 2x4 3x6 3x8 3x4 4x10 3x4 3x6 3x4 6x10 6x6 4x6 4x8 6-5-12 6-5-12 12-9-0 6-3-4 17-7-12 4-10-12 22-6-8 4-10-12 28-4-12 5-10-4 33-7-8 5-2-12 34-8-0 1-0-8 35-11-0 1-3-0 -1-0-0 1-0-0 6-5-12 6-5-12 12-9-0 6-3-4 17-7-12 4-10-12 22-6-8 4-10-12 23-2-0 0-7-8 28-4-12 5-2-12 33-7-8 5-2-12 34-8-0 1-0-8 35-11-0 1-3-0 36-11-0 1-0-0 1-1-09-7-01-1-00-8-09-7-08.00 12 Plate Offsets (X,Y)-- [2:0-3-0,0-1-12], [5:0-4-4,0-2-4], [8:0-4-4,0-2-4], [11:0-3-12,0-3-0], [11:0-0-0,0-1-12], [13:0-2-14,0-2-0], [18:0-6-4,0-3-12], [20:0-3-8,Edge], [25:0-2-8,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-SH 0.82 0.64 0.68 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.12 -0.28 0.16 (loc) 22-23 19-20 15 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 179 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 5-22: 2x4 SPF No.2, 2-26,13-15: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-5-14 oc purlins, except end verticals, and 2-0-0 oc purlins (4-7-15 max.): 5-8. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 7-21, 4-23, 6-22, 6-20 REACTIONS.(lb/size)26=1560/0-3-8, 15=1537/0-3-8 Max Horz 26=-228(LC 4) Max Uplift 26=-78(LC 6), 15=-78(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-2011/180, 4-5=-1744/236, 5-6=-1468/246, 6-7=-1439/234, 7-8=-1442/234, 8-9=-1770/237, 9-10=-2158/192, 10-12=-2501/167, 12-13=-1176/107, 2-26=-1495/175, 13-15=-1478/147 BOT CHORD 25-26=-228/285, 23-25=-111/1588, 22-23=-71/1358, 19-20=-1/1729, 18-19=-88/2187 WEBS 4-23=-314/137, 5-23=-21/394, 5-22=-147/349, 6-22=-343/169, 20-22=-55/1455, 8-20=-57/670, 9-20=-451/114, 9-19=0/295, 10-19=-473/97, 16-18=-1/1174, 12-18=-103/1566, 12-16=-1487/34, 2-25=0/1353, 13-16=-27/1013 NOTES-(10-11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 26, 15. 8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 9,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 6_Cooper_Run Truss T04 Truss Type Hip Qty 1 Ply 1 6 Cooper Run Job Reference (optional) I38108281 8.240 s Jul 14 2019 MiTek Industries, Inc. Fri Aug 9 10:19:42 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:VarUFZKVo2kjotTWURxEQNyoteT-QnapkoMhoG_pxmTVhau2x8l5M?EdtRzqwqguy6ypcPl Scale = 1:76.6 1 2 3 4 5 6 7 8 9 10 11 12 24 23 22 21 20 19 18 17 16 15 14 1325 3x6 5x8 6x6 3x4 3x6 2x4 2x4 5x6 2x4 3x4 3x6 3x8 3x4 4x10 5x8 3x6 3x4 6x10 6x6 5x8 4x6 4x8 7-8-12 7-8-12 15-3-0 7-6-4 20-8-0 5-5-0 22-6-8 1-10-8 28-1-0 5-6-8 33-7-8 5-6-8 34-8-0 1-0-8 35-11-0 1-3-0 -1-0-0 1-0-0 7-8-12 7-8-12 15-3-0 7-6-4 20-8-0 5-5-0 22-6-8 1-10-8 28-1-0 5-6-8 33-7-8 5-6-8 34-8-0 1-0-8 35-11-0 1-3-0 36-11-0 1-0-0 1-1-011-3-01-1-00-8-011-3-08.00 12 Plate Offsets (X,Y)-- [2:0-3-0,Edge], [5:0-5-12,0-2-0], [6:0-3-12,0-2-0], [9:0-2-4,0-3-0], [11:0-2-14,0-2-0], [16:0-6-8,0-3-12], [18:0-2-8,0-2-8], [23:0-2-8,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-SH 0.59 0.67 0.70 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.15 -0.34 0.17 (loc) 21-23 21-23 13 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 190 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 5-21,5-20,6-20,6-18,2-24: 2x4 SPF No.2, 11-13: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-4-15 oc purlins, except end verticals, and 2-0-0 oc purlins (4-10-13 max.): 5-6. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 7-19, 4-21, 5-20, 6-20 REACTIONS.(lb/size)24=1647/0-3-8, 13=1584/0-3-8 Max Horz 24=267(LC 5) Max Uplift 24=-88(LC 6), 13=-88(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-2170/177, 4-5=-1699/237, 5-6=-1269/242, 6-7=-1790/318, 7-8=-1848/233, 8-9=-2235/183, 9-10=-2605/165, 10-11=-1216/102, 2-24=-1579/176, 11-13=-1524/142 BOT CHORD 23-24=-276/357, 21-23=-55/1703, 20-21=0/1304, 17-18=0/1788, 16-17=-90/2311 WEBS 4-21=-530/164, 5-21=-20/575, 6-20=-279/85, 18-20=0/1324, 6-18=-138/1006, 8-18=-473/120, 8-17=0/295, 9-17=-536/114, 14-16=0/1215, 10-16=-130/1670, 10-14=-1539/26, 2-23=0/1367, 11-14=-22/1049 NOTES-(11-12) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) The Fabrication Tolerance at joint 2 = 16% 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 24, 13. 9) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 9,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 6_Cooper_Run Truss T05 Truss Type HIP Qty 1 Ply 1 6 Cooper Run Job Reference (optional) I38108282 8.240 s Jul 14 2019 MiTek Industries, Inc. Fri Aug 9 10:19:43 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:VarUFZKVo2kjotTWURxEQNyoteT-u_8By8NJZa6gZw2hFHPHULHE1PYqcuNz8UQRUZypcPk Scale = 1:86.9 1 2 3 4 5 6 7 8 9 10 11 12 24 23 22 21 20 19 18 17 16 15 14 1325 3x6 3x4 3x6 2x4 2x4 5x8 3x6 2x4 3x4 3x6 3x4 4x8 6x8 3x6 3x4 6x10 6x6 5x6 3x8 4x6 4x8 5x6 4-7-0 4-7-0 8-11-12 4-4-12 17-9-0 8-9-4 17-11-8 0-2-8 18-2-0 0-2-8 22-6-8 4-4-8 28-1-0 5-6-8 33-7-8 5-6-8 34-8-0 1-0-8 35-11-0 1-3-0 -1-0-0 1-0-0 4-7-0 4-7-0 8-11-12 4-4-12 17-9-0 8-9-4 18-2-0 0-5-0 22-6-8 4-4-8 28-1-0 5-6-8 33-7-8 5-6-8 34-8-0 1-0-8 35-11-0 1-3-0 36-11-0 1-0-0 1-1-012-11-01-1-00-8-08.00 12 Plate Offsets (X,Y)-- [2:0-3-0,0-1-12], [3:0-3-0,0-3-0], [11:0-2-14,0-2-0], [16:0-6-4,0-3-12], [18:0-3-0,0-2-0], [23:0-2-8,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-AS 0.72 0.80 0.69 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.22 -0.52 0.16 (loc) 20-21 20-21 13 l/defl >999 >820 n/a L/d 240 180 n/a PLATES MT20 Weight: 182 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 4-20,5-18,5-20: 2x4 SPF No.2, 2-24,11-13: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals. BOT CHORD Structural wood sheathing directly applied. WEBS 1 Row at midpt 6-19, 4-20 REACTIONS.(lb/size)24=1604/0-3-8, 13=1541/0-3-8 Max Horz 24=-306(LC 4) Max Uplift 24=-96(LC 6), 13=-96(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1964/147, 3-4=-1965/189, 4-5=-1475/233, 5-6=-1711/319, 6-7=-1772/221, 7-9=-2155/172, 9-10=-2506/145, 10-11=-1182/95, 2-24=-1533/156, 11-13=-1468/135 BOT CHORD 23-24=-280/360, 21-23=-103/1561, 20-21=-63/1623, 17-18=0/1724, 16-17=-72/2190 WEBS 6-18=-276/149, 4-21=0/298, 4-20=-679/182, 18-20=0/1091, 5-18=-174/820, 7-18=-466/118, 7-17=0/296, 9-17=-480/107, 14-16=0/1174, 10-16=-94/1571, 10-14=-1483/20, 2-23=-3/1354, 11-14=-20/979, 5-20=-26/495, 3-23=-254/41 NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 24, 13. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 9,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 6_Cooper_Run Truss T06 Truss Type Roof Special Qty 1 Ply 1 6 Cooper Run Job Reference (optional) I38108283 8.240 s Jul 14 2019 MiTek Industries, Inc. Fri Aug 9 10:19:45 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:VarUFZKVo2kjotTWURxEQNyoteT-rMGxMqPa5BNOoDC4MiRlZmNZHDFi4oxGcnvYZRypcPi Scale = 1:86.9 1 2 3 4 5 6 7 8 9 10 11 12 13 25 24 23 22 21 20 19 18 17 16 15 1426 3x6 3x6 3x4 3x6 2x4 2x4 5x12 3x6 2x4 2x4 3x6 3x8 3x4 3x6 4x8 6x8 3x6 3x4 6x10 6x6 6x6 4x6 4x8 6-1-8 6-1-8 12-0-8 5-11-0 17-11-8 5-11-0 22-6-8 4-7-0 28-1-0 5-6-8 33-7-8 5-6-8 34-8-0 1-0-8 35-11-0 1-3-0 -1-0-0 1-0-0 6-1-8 6-1-8 12-0-8 5-11-0 17-11-8 5-11-0 22-6-8 4-7-0 28-1-0 5-6-8 33-7-8 5-6-8 34-8-0 1-0-8 35-11-0 1-3-0 36-11-0 1-0-0 1-1-013-0-81-1-00-8-08.00 12 Plate Offsets (X,Y)-- [2:0-3-0,0-1-12], [12:0-2-14,0-2-0], [17:0-6-8,0-3-12], [19:0-4-4,0-2-0], [24:0-2-8,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-SH 0.80 0.64 0.68 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.14 -0.30 0.16 (loc) 21-22 21-22 14 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 187 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 5-21,6-21,6-19: 2x4 SPF No.2, 2-25,12-14: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-5-10 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 7-20, 5-21 REACTIONS.(lb/size)25=1576/0-3-8, 14=1543/0-3-8 Max Horz 25=308(LC 5) Max Uplift 25=-96(LC 6), 14=-96(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-2019/158, 4-5=-1808/211, 5-6=-1405/257, 6-7=-1758/339, 7-8=-1777/221, 8-10=-2160/171, 10-11=-2516/146, 11-12=-1181/96, 2-25=-1511/161, 12-14=-1484/135 BOT CHORD 24-25=-296/371, 22-24=-95/1595, 21-22=-9/1425, 18-19=0/1726, 17-18=-75/2207 WEBS 7-19=-316/172, 5-22=-0/385, 5-21=-641/172, 6-21=-86/574, 19-21=0/1069, 6-19=-189/900, 8-19=-463/116, 8-18=0/297, 10-18=-495/111, 15-17=0/1178, 11-17=-99/1588, 11-15=-1491/18, 2-24=0/1368, 12-15=-16/1015 NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 25, 14. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 9,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 6_Cooper_Run Truss T07 Truss Type Common Qty 1 Ply 1 6 Cooper Run Job Reference (optional) I38108284 8.240 s Jul 14 2019 MiTek Industries, Inc. Fri Aug 9 10:19:46 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:VarUFZKVo2kjotTWURxEQNyoteT-JZqJaAQCsVVFQNnGwQy_6_vkqccqpItPqRe55uypcPh Scale = 1:86.5 1 2 3 4 5 6 7 8 9 10 19 18 17 16 15 14 13 12 112021 3x6 5x6 3x6 3x4 3x6 4x8 3x6 3x4 3x6 3x8 3x6 3x4 3x6 3x8 6x6 3x4 6x6 3x6 6-1-8 6-1-8 12-0-8 5-11-0 17-11-8 5-11-0 23-10-8 5-11-0 29-9-8 5-11-0 35-11-0 6-1-8 -1-0-0 1-0-0 6-1-8 6-1-8 12-0-8 5-11-0 17-11-8 5-11-0 23-10-8 5-11-0 29-9-8 5-11-0 35-11-0 6-1-8 1-1-013-0-81-1-08.00 12 Plate Offsets (X,Y)-- [2:0-3-0,0-1-12], [10:Edge,0-1-12], [12:0-2-8,0-1-8], [18:0-2-8,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-SH 0.82 0.59 0.51 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.14 -0.28 0.08 (loc) 13-15 13-15 11 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 173 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 6-15,7-15,5-15: 2x4 SPF No.2, 2-19,10-11: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-7-13 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 7-15, 5-15 REACTIONS.(lb/size)19=1629/0-3-8, 11=1558/0-3-8 Max Horz 19=317(LC 5) Max Uplift 19=-95(LC 6), 11=-59(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-2098/157, 4-5=-1892/211, 5-6=-1496/256, 6-7=-1496/256, 7-8=-1896/212, 8-10=-2101/156, 2-19=-1564/160, 10-11=-1493/123 BOT CHORD 18-19=-305/359, 17-18=-107/1661, 15-17=-21/1495, 13-15=0/1496, 12-13=-39/1671 WEBS 6-15=-171/1216, 7-15=-629/172, 7-13=-3/378, 8-13=-253/114, 5-15=-628/172, 5-17=-1/371, 2-18=0/1432, 10-12=-17/1487 NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 19, 11. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 9,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 6_Cooper_Run Truss T08 Truss Type Common Qty 8 Ply 1 6 Cooper Run Job Reference (optional) I38108285 8.240 s Jul 14 2019 MiTek Industries, Inc. Fri Aug 9 10:19:47 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:VarUFZKVo2kjotTWURxEQNyoteT-nlOinWQqdpd52XMSU7TDeBSxY0y3Yl6Z35OfdKypcPg Scale = 1:85.7 1 2 3 4 5 6 7 8 9 18 17 16 15 14 13 12 11 101920 3x6 5x6 3x6 3x4 3x6 4x8 3x6 3x4 3x6 3x8 3x6 3x4 3x6 3x8 5x6 3x4 5x6 3x6 6-1-8 6-1-8 12-0-8 5-11-0 17-11-8 5-11-0 23-10-8 5-11-0 29-9-8 5-11-0 35-11-0 6-1-8 6-1-8 6-1-8 12-0-8 5-11-0 17-11-8 5-11-0 23-10-8 5-11-0 29-9-8 5-11-0 35-11-0 6-1-8 1-1-013-0-81-1-08.00 12 Plate Offsets (X,Y)-- [1:Edge,0-1-12], [9:Edge,0-1-12], [11:0-2-8,0-1-8], [17:0-2-8,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-SH 0.63 0.59 0.51 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.14 -0.28 0.08 (loc) 14-16 14-16 10 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 172 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 5-14,6-14,4-14: 2x4 SPF No.2, 1-18,9-10: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-7-13 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 6-14, 4-14 REACTIONS.(lb/size)18=1559/Mechanical, 10=1559/Mechanical Max Horz 18=305(LC 5) Max Uplift 18=-59(LC 6), 10=-59(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-3=-2103/156, 3-4=-1898/212, 4-5=-1498/256, 5-6=-1498/256, 6-7=-1898/212, 7-9=-2103/156, 1-18=-1494/123, 9-10=-1494/123 BOT CHORD 17-18=-288/348, 16-17=-110/1672, 14-16=-21/1497, 12-14=0/1497, 11-12=-39/1672 WEBS 5-14=-171/1216, 6-14=-629/172, 6-12=-3/378, 7-12=-253/114, 4-14=-629/172, 4-16=-3/378, 3-16=-253/115, 1-17=-17/1488, 9-11=-17/1488 NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 18, 10. 8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 9,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 6_Cooper_Run Truss T09 Truss Type Roof Special Qty 1 Ply 1 6 Cooper Run Job Reference (optional) I38108286 8.240 s Jul 14 2019 MiTek Industries, Inc. Fri Aug 9 10:19:48 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:VarUFZKVo2kjotTWURxEQNyoteT-Fxy4?rRSN6lyfhxe2r_SBP?4sQILH9giIl7C9mypcPf Scale = 1:74.4 1 2 3 4 5 6 7 8 9 18 17 16 15 14 13 12 11 10 3x6 5x6 3x6 3x4 3x6 3x6 3x8 3x4 3x6 4x8 3x6 3x4 3x6 3x8 5x6 3x4 4x6 3x6 6-6-9 6-6-9 12-10-10 6-4-1 19-2-11 6-4-1 24-8-10 5-5-15 30-2-9 5-5-15 35-11-0 5-8-7 6-6-9 6-6-9 12-10-10 6-4-1 19-2-11 6-4-1 24-8-10 5-5-15 30-2-9 5-5-15 35-11-0 5-8-7 1-0-012-2-91-1-07.00 12 8.00 12 Plate Offsets (X,Y)-- [1:Edge,0-1-12], [5:0-3-8,0-2-8], [9:0-3-0,0-1-8], [11:0-2-8,0-1-8], [17:0-2-8,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-SH 0.72 0.58 0.68 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.15 -0.32 0.08 (loc) 14-16 14-16 10 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 161 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 5-14: 2x4 SPF No.2, 1-18,9-10: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-4-12 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 4-14, 6-14 REACTIONS.(lb/size)18=1539/Mechanical, 10=1548/Mechanical Max Horz 18=286(LC 5) Max Uplift 18=-68(LC 6), 10=-56(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-3=-2263/165, 3-4=-1990/209, 4-5=-1518/242, 5-6=-1547/248, 6-7=-1910/208, 7-9=-2074/154, 1-18=-1469/125, 9-10=-1487/120 BOT CHORD 17-18=-263/345, 16-17=-125/1876, 14-16=-35/1637, 12-14=0/1513, 11-12=-42/1653 WEBS 3-16=-318/110, 4-16=0/409, 4-14=-709/162, 5-14=-148/1188, 6-14=-569/159, 6-12=-3/333, 1-17=-30/1626, 9-11=-25/1492 NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 18, 10. 8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 9,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 6_Cooper_Run Truss T10 Truss Type Roof Special Qty 1 Ply 1 6 Cooper Run Job Reference (optional) I38108287 8.240 s Jul 14 2019 MiTek Industries, Inc. Fri Aug 9 10:19:51 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:VarUFZKVo2kjotTWURxEQNyoteT-fWdCdtTLg17XW8fDjzY9p1daudJBUYL8_jMsm5ypcPc Scale = 1:74.7 1 2 3 4 5 6 7 8 9 18 17 16 15 14 13 12 11 10192021 3x6 5x8 5x6 3x6 3x4 3x6 3x6 3x8 3x4 3x6 3x6 3x8 3x6 3x8 5x6 3x4 6x6 3x6 5-10-12 5-10-12 11-7-0 5-8-4 17-3-5 5-8-4 20-11-2 3-7-13 28-3-13 7-4-11 35-11-0 7-7-3 5-10-12 5-10-12 11-7-0 5-8-4 17-3-5 5-8-4 20-11-2 3-7-13 28-3-13 7-4-11 35-11-0 7-7-3 1-0-011-0-151-1-011-0-157.00 12 8.00 12 Plate Offsets (X,Y)-- [1:Edge,0-1-12], [5:0-6-0,0-2-4], [6:0-3-12,0-2-0], [9:Edge,0-1-12], [11:0-2-8,0-1-8], [17:0-2-8,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-SH 0.79 0.64 0.56 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.14 -0.33 0.08 (loc) 11-12 11-12 10 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 171 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 5-14,5-12,6-12: 2x4 SPF No.2, 1-18,9-10: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-0-6 oc purlins, except end verticals, and 2-0-0 oc purlins (4-11-13 max.): 5-6. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 4-14, 5-12, 7-12 REACTIONS.(lb/size)18=1524/Mechanical, 10=1546/0-3-8 Max Horz 18=260(LC 5) Max Uplift 18=-62(LC 6), 10=-50(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-3=-2220/169, 3-4=-2024/212, 4-5=-1593/243, 5-6=-1274/238, 6-7=-1664/234, 7-9=-2124/172, 1-18=-1458/126, 9-10=-1480/135 BOT CHORD 17-18=-239/306, 16-17=-113/1846, 14-16=-33/1676, 12-14=0/1299, 11-12=-36/1676 WEBS 4-16=0/360, 4-14=-633/144, 5-14=-65/596, 6-12=-25/532, 7-12=-540/164, 1-17=-47/1630, 9-11=-3/1444 NOTES-(11-12) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 7) Refer to girder(s) for truss to truss connections. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 18, 10. 9) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 9,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 6_Cooper_Run Truss T11 Truss Type Half Hip Qty 2 Ply 1 6 Cooper Run Job Reference (optional) I38108288 8.240 s Jul 14 2019 MiTek Industries, Inc. Fri Aug 9 10:19:54 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:VarUFZKVo2kjotTWURxEQNyoteT-45JLFvWDzyV6NcOoO55tQgEDtrSkh0qbghaWNQypcPZ Scale = 1:21.8 1 2 3 6 4 5 3x4 3x4 3x4 2-0-0 2-0-0 3-11-4 1-11-4 4-0-0 0-0-12 -1-0-0 1-0-0 3-0-0 3-0-0 4-0-0 1-0-0 1-3-03-9-010.00 12 Plate Offsets (X,Y)-- [3:0-1-6,0-0-10] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-R 0.30 0.14 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.02 -0.03 -0.05 (loc) 5-6 5-6 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 13 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins: 3-4. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)4=99/Mechanical, 6=231/0-3-8, 5=42/Mechanical Max Horz 6=100(LC 6) Max Uplift 4=-60(LC 7), 6=-5(LC 6) Max Grav 4=99(LC 1), 6=231(LC 1), 5=73(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(11-12) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 7) Refer to girder(s) for truss to truss connections. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4, 6. 9) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 9,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 6_Cooper_Run Truss T12 Truss Type Half Hip Qty 1 Ply 1 6 Cooper Run Job Reference (optional) I38108289 8.240 s Jul 14 2019 MiTek Industries, Inc. Fri Aug 9 10:19:54 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:VarUFZKVo2kjotTWURxEQNyoteT-45JLFvWDzyV6NcOoO55tQgED4rTth0SbghaWNQypcPZ Scale = 1:21.8 1 2 3 4 9 8 7 5 6 3x6 3x4 2x4 2x4 2x4 3x4 2-3-8 2-3-8 3-11-5 1-7-13 4-0-0 0-0-11 -1-0-0 1-0-0 2-3-8 2-3-8 3-0-0 0-8-8 4-0-0 1-0-0 1-3-03-9-03-1-00-8-03-9-010.00 12 Plate Offsets (X,Y)-- [4:0-3-2,0-2-2] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-SH 0.29 0.13 0.02 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.06 -0.07 -0.09 (loc) 8 8 5 l/defl >789 >662 n/a L/d 240 180 n/a PLATES MT20 Weight: 15 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-9: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins: 4-5. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)5=124/Mechanical, 9=231/0-3-8, 6=17/Mechanical Max Horz 9=132(LC 6) Max Uplift 5=-63(LC 6), 9=-1(LC 6) Max Grav 5=124(LC 1), 9=231(LC 1), 6=35(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(11-12) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 7) Refer to girder(s) for truss to truss connections. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 9. 9) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 9,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 6_Cooper_Run Truss T13 Truss Type Common Qty 7 Ply 1 6 Cooper Run Job Reference (optional) I38108290 8.240 s Jul 14 2019 MiTek Industries, Inc. Fri Aug 9 10:19:55 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:VarUFZKVo2kjotTWURxEQNyoteT-YHtjTFXrkGdz?mz?ypc6ztnJjFgMQIPkvLK4vsypcPY Scale = 1:58.3 1 2 3 4 5 6 7 11 10 9 8121314 4x6 3x8 3x8 3x4 3x4 3x4 4x6 4x6 3x4 9-11-8 9-11-8 19-11-0 9-11-8 -1-0-0 1-0-0 5-1-0 5-1-0 9-11-8 4-10-8 14-10-0 4-10-8 19-11-0 5-1-0 20-11-0 1-0-0 1-3-09-6-91-3-010.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-SH 0.61 0.69 0.75 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.18 -0.47 0.02 (loc) 9-11 9-11 8 l/defl >999 >506 n/a L/d 240 180 n/a PLATES MT20 Weight: 87 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-11,6-8: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)11=947/0-3-8, 8=947/0-3-8 Max Horz 11=-229(LC 4) Max Uplift 11=-60(LC 6), 8=-60(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-346/124, 3-4=-764/145, 4-5=-764/145, 5-6=-346/124, 2-11=-375/142, 6-8=-375/142 BOT CHORD 9-11=-63/624, 8-9=0/625 WEBS 4-9=-87/570, 3-11=-621/18, 5-8=-621/17 NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 11, 8. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 9,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 6_Cooper_Run Truss T14 Truss Type Common Qty 3 Ply 1 6 Cooper Run Job Reference (optional) I38108291 8.240 s Jul 14 2019 MiTek Industries, Inc. Fri Aug 9 10:19:56 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:VarUFZKVo2kjotTWURxEQNyoteT-0UQ5gbXTValqdvYBWW8LW5KUTe0Z9kAt8?3dSIypcPX Scale = 1:58.3 1 2 3 4 5 6 10 9 8 7111213 4x6 3x4 3x8 3x8 3x4 3x4 3x4 4x6 4x6 9-11-8 9-11-8 19-11-0 9-11-8 -1-0-0 1-0-0 5-1-0 5-1-0 9-11-8 4-10-8 14-10-0 4-10-8 19-11-0 5-1-0 1-3-09-6-91-3-010.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-SH 0.61 0.69 0.78 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.18 -0.47 0.02 (loc) 7-8 8-10 7 l/defl >999 >505 n/a L/d 240 180 n/a PLATES MT20 Weight: 85 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-10,6-7: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)10=949/0-3-8, 7=876/0-3-8 Max Horz 10=240(LC 5) Max Uplift 10=-60(LC 6), 7=-25(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-346/124, 3-4=-767/144, 4-5=-768/145, 5-6=-326/86, 2-10=-375/142, 6-7=-285/77 BOT CHORD 8-10=-74/626, 7-8=0/633 WEBS 4-8=-88/576, 3-10=-624/17, 5-7=-647/41 NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 10, 7. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 9,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 6_Cooper_Run Truss T15 Truss Type Common Qty 1 Ply 1 6 Cooper Run Job Reference (optional) I38108292 8.240 s Jul 14 2019 MiTek Industries, Inc. Fri Aug 9 10:19:57 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:VarUFZKVo2kjotTWURxEQNyoteT-Ug_UuwY6GtthE37N3Efa2Isf12MzuBt1MfpB_lypcPW Scale = 1:58.3 1 2 3 4 5 6 10 9 8 7111213 4x6 3x4 3x8 3x4 3x8 3x4 3x4 4x6 6x6 9-11-8 9-11-8 19-7-8 9-8-0 19-11-0 0-3-8 -1-0-0 1-0-0 5-1-0 5-1-0 9-11-8 4-10-8 14-8-4 4-8-12 19-7-8 4-11-4 19-11-0 0-3-8 1-3-09-6-90-3-810.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-SH 0.62 0.68 0.81 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.19 -0.48 0.02 (loc) 8-10 8-10 7 l/defl >999 >484 n/a L/d 240 180 n/a PLATES MT20 Weight: 85 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-10,6-7: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)10=937/0-3-8, 7=868/0-3-8 Max Horz 10=243(LC 5) Max Uplift 10=-60(LC 6), 7=-23(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-346/123, 3-4=-751/144, 4-5=-748/146, 5-6=-263/93, 2-10=-374/141 BOT CHORD 8-10=-79/615, 7-8=0/596 WEBS 4-8=-89/559, 3-10=-608/18, 5-7=-680/33 NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 10, 7. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 9,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 6_Cooper_Run Truss T16 Truss Type Common Qty 1 Ply 1 6 Cooper Run Job Reference (optional) I38108293 8.240 s Jul 14 2019 MiTek Industries, Inc. Fri Aug 9 10:19:57 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:VarUFZKVo2kjotTWURxEQNyoteT-Ug_UuwY6GtthE37N3Efa2Isf22MbuEo1MfpB_lypcPW Scale = 1:36.4 1 2 3 4 5 6 7 11 10 9 8 4x6 3x8 3x8 3x6 3x6 3x4 4x6 3x4 4x6 9-9-8 9-9-8 19-7-0 9-9-8 -1-0-0 1-0-0 5-0-0 5-0-0 9-9-8 4-9-8 14-7-0 4-9-8 19-7-0 5-0-0 20-7-0 1-0-0 0-11-05-9-120-11-06.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-SH 0.62 0.70 0.63 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.17 -0.44 0.03 (loc) 9-11 9-11 8 l/defl >999 >525 n/a L/d 240 180 n/a PLATES MT20 Weight: 73 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-11,6-8: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)11=840/0-5-8, 8=840/0-5-8 Max Horz 11=63(LC 5) Max Uplift 11=-73(LC 6), 8=-73(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-334/57, 3-4=-870/148, 4-5=-870/148, 5-6=-334/57, 2-11=-333/118, 6-8=-333/118 BOT CHORD 9-11=-72/896, 8-9=-72/896 WEBS 4-9=-22/483, 3-11=-779/143, 5-8=-779/143 NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 11, 8. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 9,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 6_Cooper_Run Truss T17 Truss Type Roof Special Qty 1 Ply 1 6 Cooper Run Job Reference (optional) I38108294 8.240 s Jul 14 2019 MiTek Industries, Inc. Fri Aug 9 10:19:58 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:VarUFZKVo2kjotTWURxEQNyoteT-ysYs5GZk1B?YsDiZdxApbWPnzScidj2AbJYkWBypcPV Scale = 1:66.5 1 2 3 4 5 6 7 8 9 10 11 19 18 17 16 15 14 13 122021 3x6 5x6 5x6 3x6 10x10 3x6 3x6 3x8 4x8 3x4 4x8 3x6 3x8 3x4 6x6 3x8 MT18HS 7-3-12 7-3-12 14-5-0 7-1-4 23-5-2 9-0-2 29-6-13 6-1-11 35-11-0 6-4-3 -1-0-0 1-0-0 7-3-12 7-3-12 14-5-0 7-1-4 18-11-1 4-6-1 23-5-2 4-6-1 29-6-13 6-1-11 35-11-0 6-4-3 36-11-0 1-0-0 1-0-09-4-151-1-09-4-157.00 12 8.00 12 Plate Offsets (X,Y)-- [5:0-4-0,0-2-4], [7:0-4-4,0-2-4], [10:0-3-0,0-1-12], [13:0-2-8,0-1-8], [18:0-2-8,0-1-8], [19:Edge,0-8-0], [19:0-1-12,0-0-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-SH 0.80 0.97 0.50 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.36 -0.65 0.08 (loc) 14-17 14-17 12 l/defl >999 >661 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 153 lb FT = 20% GRIP 169/123 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-19: 2x4 SPF No.2, 10-12: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-5-15 oc purlins, except end verticals, and 2-0-0 oc purlins (4-8-1 max.): 5-7. BOT CHORD Structural wood sheathing directly applied or 2-2-0 oc bracing. WEBS 1 Row at midpt 4-17, 6-17, 6-14 REACTIONS.(lb/size)19=1587/0-3-8, 12=1598/0-3-8 Max Horz 19=-224(LC 4) Max Uplift 19=-88(LC 6), 12=-76(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-2233/189, 4-5=-1876/226, 5-6=-1523/232, 6-7=-1442/226, 7-8=-1838/227, 8-10=-2054/179, 2-19=-1507/178, 10-12=-1525/174 BOT CHORD 18-19=-221/393, 17-18=-85/1837, 14-17=-34/1544, 13-14=-19/1624, 12-13=-23/254 WEBS 4-17=-402/147, 5-17=-3/553, 6-14=-344/162, 7-14=-23/653, 8-14=-262/141, 2-18=0/1452, 10-13=-2/1383 NOTES-(11-12) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 19, 12. 9) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 9,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 6_Cooper_Run Truss T18 Truss Type ROOF SPECIAL Qty 1 Ply 1 6 Cooper Run Job Reference (optional) I38108295 8.240 s Jul 14 2019 MiTek Industries, Inc. Fri Aug 9 10:19:59 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:VarUFZKVo2kjotTWURxEQNyoteT-Q36EJcaMoV7OUNGmBeh27jyxys1VM7oKqzIH2dypcPU Scale = 1:61.9 1 2 3 4 5 6 7 8 9 18 17 16 15 14 13 12 11 101920 5x8 5x8 10x10 3x6 3x6 3x8 3x4 2x4 3x8 3x4 3x6 3x8 3x4 5x6 3x6 5-10-10 5-10-10 11-6-11 5-8-2 18-8-15 7-2-3 25-11-2 7-2-3 30-9-13 4-10-11 35-11-0 5-1-3 -1-0-0 1-0-0 5-10-10 5-10-10 11-6-11 5-8-2 18-8-15 7-2-3 25-11-2 7-2-3 30-9-13 4-10-11 35-11-0 5-1-3 36-11-0 1-0-0 1-0-07-8-151-1-07-8-157.00 12 8.00 12 Plate Offsets (X,Y)-- [4:0-5-0,0-1-12], [6:0-4-8,0-1-8], [8:0-3-0,0-1-12], [11:0-2-8,0-1-8], [17:0-2-8,0-1-8], [18:Edge,0-8-0], [18:0-1-12,0-0-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-AS 0.85 0.67 0.66 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.17 -0.35 0.09 (loc) 14-16 14-16 10 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 149 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-18,8-10: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals, and 2-0-0 oc purlins (3-7-7 max.): 4-6. BOT CHORD Structural wood sheathing directly applied. REACTIONS.(lb/size)18=1627/0-3-8, 10=1639/0-3-8 Max Horz 18=-185(LC 4) Max Uplift 18=-74(LC 6), 10=-64(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2264/190, 3-4=-2076/231, 4-5=-1988/256, 5-6=-1988/256, 6-7=-1984/227, 7-8=-2064/179, 2-18=-1554/177, 8-10=-1572/174 BOT CHORD 17-18=-175/329, 16-17=-145/1876, 14-16=-125/1722, 12-14=-23/1588, 11-12=-33/1643 WEBS 4-16=0/369, 4-14=-161/491, 5-14=-479/201, 6-14=-150/656, 6-12=0/306, 2-17=-43/1561, 8-11=-35/1441 NOTES-(11-12) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 18, 10. 8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 9,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 6_Cooper_Run Truss T19 Truss Type Roof Special Qty 1 Ply 1 6 Cooper Run Job Reference (optional) I38108296 8.240 s Jul 14 2019 MiTek Industries, Inc. Fri Aug 9 10:20:00 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:VarUFZKVo2kjotTWURxEQNyoteT-uFgcWya_ZoFF5XrylMCHgxUAoGMj5Y5T2d1rb4ypcPT Scale = 1:62.9 1 2 3 4 5 6 7 8 9 10 11 21 20 19 18 17 16 15 14 13 12222324 5x8 3x6 5x6 3x4 3x6 3x6 3x8 3x4 4x8 2x4 2x4 3x8 3x8 3x6 3x8 4x6 3x4 4x6 3x6 4-5-7 4-5-7 8-8-7 4-2-15 15-3-12 6-7-5 21-9-13 6-6-1 28-5-2 6-7-5 32-0-13 3-7-11 35-11-0 3-10-3 -1-0-0 1-0-0 4-5-7 4-5-7 8-8-7 4-2-15 15-3-12 6-7-5 21-9-13 6-6-1 28-5-2 6-7-5 32-0-13 3-7-11 35-11-0 3-10-3 36-11-0 1-0-0 1-0-06-0-151-1-06-0-157.00 12 8.00 12 Plate Offsets (X,Y)-- [2:0-3-0,0-1-8], [4:0-5-8,0-2-0], [8:0-3-12,0-2-0], [10:0-3-0,0-1-12], [13:0-2-8,0-1-8], [20:0-2-8,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-SH 0.59 0.74 0.78 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.17 -0.39 0.12 (loc) 15-17 15-17 12 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 147 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-21,10-12: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-9-14 oc purlins, except end verticals, and 2-0-0 oc purlins (3-2-2 max.): 4-8. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 7-17, 7-14 REACTIONS.(lb/size)21=1628/0-3-8, 12=1627/0-3-8 Max Horz 21=-146(LC 4) Max Uplift 21=-65(LC 5), 12=-69(LC 4) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2183/188, 3-4=-2181/228, 4-5=-2463/278, 5-7=-2463/278, 7-8=-1646/208, 8-9=-2015/219, 9-10=-1950/176, 2-21=-1569/175, 10-12=-1574/174 BOT CHORD 19-20=-192/1822, 17-19=-188/1833, 15-17=-217/2448, 14-15=-217/2448, 13-14=-45/1562 WEBS 4-17=-185/902, 5-17=-413/171, 7-15=0/291, 7-14=-1122/184, 8-14=-26/785, 9-13=-298/55, 2-20=-73/1655, 10-13=-60/1475 NOTES-(10-11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 21, 12. 8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 9,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 6_Cooper_Run Truss T20 Truss Type Half Hip Qty 1 Ply 1 6 Cooper Run Job Reference (optional) I38108297 8.240 s Jul 14 2019 MiTek Industries, Inc. Fri Aug 9 10:20:01 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:VarUFZKVo2kjotTWURxEQNyoteT-NRE_jIbcK6O6jhQ8I3jWC81RafrOqBZdHHnO7WypcPS Scale = 1:13.7 1 2 3 6 4 5 4x6 2x4 2x4 1-1-3 1-1-3 3-11-4 2-10-1 4-0-0 0-0-12 -1-0-0 1-0-0 1-1-3 1-1-3 4-0-0 2-10-13 1-3-02-2-010.00 12 Plate Offsets (X,Y)-- [3:0-2-4,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-R 0.21 0.13 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.01 -0.03 0.04 (loc) 5-6 5-6 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 12 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins: 3-4. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)4=101/Mechanical, 6=231/0-3-8, 5=41/Mechanical Max Horz 6=51(LC 6) Max Uplift 4=-36(LC 4), 6=-30(LC 6) Max Grav 4=102(LC 11), 6=231(LC 1), 5=72(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(11-12) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) -1-0-0 to 3-11-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 7) Refer to girder(s) for truss to truss connections. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4, 6. 9) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 9,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 6_Cooper_Run Truss T21 Truss Type Half Hip Qty 1 Ply 1 6 Cooper Run Job Reference (optional) I38108298 8.240 s Jul 14 2019 MiTek Industries, Inc. Fri Aug 9 10:20:01 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:VarUFZKVo2kjotTWURxEQNyoteT-NRE_jIbcK6O6jhQ8I3jWC81QYfrMqBZdHHnO7WypcPS Scale = 1:19.6 1 2 3 6 4 5 3x6 3x4 2x4 2-6-0 2-6-0 3-11-4 1-5-4 4-0-0 0-0-12 -1-0-0 1-0-0 2-6-0 2-6-0 4-0-0 1-6-0 1-3-03-4-010.00 12 Plate Offsets (X,Y)-- [3:0-4-0,0-1-12] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-R 0.27 0.14 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.01 -0.03 0.05 (loc) 5-6 5-6 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 13 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins: 3-4. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)4=100/Mechanical, 6=231/0-3-8, 5=42/Mechanical Max Horz 6=87(LC 6) Max Uplift 4=-51(LC 7), 6=-14(LC 6) Max Grav 4=100(LC 1), 6=231(LC 1), 5=72(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(11-12) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 7) Refer to girder(s) for truss to truss connections. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4, 6. 9) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 9,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 6_Cooper_Run Truss T22 Truss Type Half Hip Qty 1 Ply 1 6 Cooper Run Job Reference (optional) I38108299 8.240 s Jul 14 2019 MiTek Industries, Inc. Fri Aug 9 10:20:02 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:VarUFZKVo2kjotTWURxEQNyoteT-reoNxecE4QWzLq?LsnEllMabf3BXZepmWxWyfyypcPR Scale = 1:22.8 1 2 3 6 4 5 4x6 3x4 3x4 2-0-0 2-0-0 3-11-4 1-11-4 4-0-0 0-0-12 -1-0-0 1-0-0 3-3-0 3-3-0 4-0-0 0-9-0 1-3-03-11-810.00 12 Plate Offsets (X,Y)-- [3:0-2-4,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-R 0.31 0.14 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.02 -0.03 -0.05 (loc) 5-6 5-6 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 13 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins: 3-4. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)4=99/Mechanical, 6=231/0-3-8, 5=42/Mechanical Max Horz 6=106(LC 6) Max Uplift 4=-65(LC 7) Max Grav 4=99(LC 1), 6=231(LC 1), 5=73(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(11-12) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 7) Refer to girder(s) for truss to truss connections. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4. 9) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 9,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 6_Cooper_Run Truss TG01 Truss Type Hip Girder Qty 1 Ply 1 6 Cooper Run Job Reference (optional) I38108300 8.240 s Jul 14 2019 MiTek Industries, Inc. Fri Aug 9 10:20:04 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:VarUFZKVo2kjotTWURxEQNyoteT-n0v7MKeVc1mha89j_CHDqnfqWthj1Jr3zF?2krypcPP Scale: 3/16"=1' 1 2 3 4 5 6 7 8 9 10 11 12 13 14 28 27 26 25 24 23 22 21 20 19 18 17 16 15 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 6x8 3x6 6x10 10x10 4x8 2x4 3x6 3x6 2x4 10x10 3x6 8x8 4x6 5x12 2x4 3x12 8x8 8x10 2x4 5x12 4x6 8x10 6x6 6x10 2-9-4 2-9-4 5-3-0 2-5-12 11-0-3 5-9-3 16-9-5 5-9-3 22-6-8 5-9-3 26-7-4 4-0-12 30-8-0 4-0-12 33-7-8 2-11-8 34-7-8 1-0-0 35-11-0 1-3-8 -1-0-0 1-0-0 2-9-4 2-9-4 5-3-0 2-5-12 11-0-3 5-9-3 16-9-5 5-9-3 22-6-8 5-9-3 26-7-4 4-0-12 30-8-0 4-0-12 33-7-8 2-11-8 34-7-8 1-0-0 35-11-0 1-3-8 36-11-0 1-0-0 1-1-04-7-01-1-00-8-04-7-08.00 12 Plate Offsets (X,Y)-- [4:0-5-12,0-2-0], [10:0-7-8,0-1-12], [15:0-1-12,0-0-0], [15:Edge,0-8-2], [18:0-7-8,0-5-0], [21:0-6-8,0-6-4], [23:0-3-8,0-4-0], [27:0-3-8,0-4-0], [28:0-1-12 ,0-0-0], [28:Edge,0-8-2] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-SH 0.67 0.86 0.99 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.38 -0.66 0.24 (loc) 22-23 22-23 15 l/defl >999 >648 n/a L/d 240 180 n/a PLATES MT20 Weight: 194 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 4-7,7-10: 2x4 SPF 2100F 1.8E BOT CHORD 2x6 SPF No.2 *Except* 18-21: 2x6 SP 2400F 2.0E WEBS 2x4 SPF-S Stud *Except* 8-22,11-17,4-26,4-24,5-24,6-23,21-23,12-18: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-6-11 oc purlins, except end verticals, and 2-0-0 oc purlins (3-1-15 max.): 4-10. BOT CHORD Structural wood sheathing directly applied or 5-6-9 oc bracing. WEBS 1 Row at midpt 8-20 REACTIONS.(lb/size)28=1954/0-3-8, 15=1951/0-3-8 Max Horz 28=108(LC 4) Max Uplift 28=-652(LC 4), 15=-714(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2208/809, 3-4=-2498/998, 4-5=-3557/1511, 5-6=-3556/1511, 6-8=-4928/2147, 8-9=-3759/1663, 9-10=-3759/1663, 10-11=-2966/1273, 11-12=-3823/1513, 12-13=-1544/616, 2-28=-1850/636, 13-15=-1769/658 BOT CHORD 26-27=-724/1781, 24-26=-857/2063, 23-24=-1799/4176, 20-21=-2181/4994, 19-20=-1016/2449, 18-19=-1303/3425 WEBS 8-21=-222/661, 11-18=-239/720, 3-27=-542/234, 3-26=-264/447, 4-24=-867/1869, 5-24=-479/315, 6-24=-786/386, 6-23=-452/305, 21-23=-1738/4037, 6-21=-424/878, 8-20=-1606/708, 9-20=-292/173, 10-20=-817/1757, 11-19=-1049/347, 16-18=-603/1607, 12-18=-898/2351, 12-16=-2225/861, 2-27=-582/1667, 13-16=-454/1196 NOTES-(12-13) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 28=652, 15=714. 8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. Continued on page 2 August 9,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 6_Cooper_Run Truss TG01 Truss Type Hip Girder Qty 1 Ply 1 6 Cooper Run Job Reference (optional) I38108300 8.240 s Jul 14 2019 MiTek Industries, Inc. Fri Aug 9 10:20:04 2019 Page 2 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:VarUFZKVo2kjotTWURxEQNyoteT-n0v7MKeVc1mha89j_CHDqnfqWthj1Jr3zF?2krypcPP NOTES-(12-13) 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 58 lb down and 78 lb up at 5-3-0, 56 lb down and 78 lb up at 7-3-12, 56 lb down and 78 lb up at 9-3-12, 56 lb down and 78 lb up at 11-3-12, 56 lb down and 78 lb up at 13-3-12, 56 lb down and 78 lb up at 15-3-12, 56 lb down and 78 lb up at 17-3-12, 56 lb down and 78 lb up at 19-3-12, 56 lb down and 78 lb up at 21-3-12, 59 lb down and 60 lb up at 23-3-12, 59 lb down and 60 lb up at 25-3-12, 59 lb down and 60 lb up at 27-3-12, and 59 lb down and 60 lb up at 29-3-12, and 51 lb down and 60 lb up at 30-8-0 on top chord, and 34 lb down and 17 lb up at 2-0-12, 33 lb down at 4-0-12, 33 lb down and 16 lb up at 5-3-12, 33 lb down and 16 lb up at 7-3-12, 33 lb down and 16 lb up at 9-3-12, 33 lb down and 16 lb up at 11-3-12, 33 lb down and 16 lb up at 13-3-12, 33 lb down and 16 lb up at 15-3-12, 33 lb down and 16 lb up at 17-3-12, 33 lb down and 16 lb up at 19-3-12, 33 lb down and 16 lb up at 21-3-12, 34 lb down and 48 lb up at 23-3-12, 34 lb down and 48 lb up at 25-3-12, 34 lb down and 48 lb up at 27-3-12, 34 lb down and 48 lb up at 29-3-12, 34 lb down and 48 lb up at 30-7-4, and at 31-10-4, and 34 lb down and 17 lb up at 33-9-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 11) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 12) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 13) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 2-4=-60, 4-10=-60, 10-13=-60, 13-14=-60, 22-28=-20, 18-21=-20, 15-17=-20 Concentrated Loads (lb) Vert: 4=-39(B) 7=-39(B) 10=-28(B) 26=-22(B) 24=-22(B) 5=-39(B) 19=-34(B) 18=-19(B) 29=-39(B) 30=-39(B) 31=-39(B) 32=-39(B) 33=-39(B) 34=-39(B) 35=-28(B) 36=-28(B) 37=-28(B) 38=-28(B) 39=-19(B) 40=-22(B) 41=-22(B) 42=-22(B) 43=-22(B) 44=-22(B) 45=-22(B) 46=-22(B) 47=-22(B) 48=-34(B) 49=-34(B) 50=-34(B) 51=-34(B) 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 6_Cooper_Run Truss TG02 Truss Type Half Hip Girder Qty 3 Ply 1 6 Cooper Run Job Reference (optional) I38108301 8.240 s Jul 14 2019 MiTek Industries, Inc. Fri Aug 9 10:20:05 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:VarUFZKVo2kjotTWURxEQNyoteT-FDTVZge7NLuYCIkwXvoSN_C6GHAkm?YCCvlcGHypcPO Scale = 1:14.9 1 2 3 6 7 4 8 9 5 3x4 2x4 3x4 1-4-13 1-4-13 3-11-4 2-6-7 4-0-0 0-0-12 -1-0-0 1-0-0 1-4-13 1-4-13 4-0-0 2-7-3 1-3-02-5-010.00 12 Plate Offsets (X,Y)-- [3:0-2-8,0-2-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-R 0.22 0.30 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.02 -0.04 0.05 (loc) 5-6 5-6 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 12 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF-S Stud WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins: 3-4. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)4=101/Mechanical, 6=227/0-3-8, 5=38/Mechanical Max Horz 6=59(LC 5) Max Uplift 4=-57(LC 6), 6=-53(LC 5), 5=-5(LC 5) Max Grav 4=101(LC 1), 6=227(LC 1), 5=74(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(13-14) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 7) Refer to girder(s) for truss to truss connections. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4, 6, 5. 9) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 11) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 77 lb down and 32 lb up at 1-4-13, and 34 lb down and 29 lb up at 3-5-9 on top chord, and 3 lb down and 16 lb up at 1-4-13, and 4 lb down and 15 lb up at 3-5-9 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 12) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 13) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 14) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 2-3=-60, 3-4=-60, 5-6=-20 Concentrated Loads (lb) Vert: 8=5(F) 9=-0(F) August 9,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 6_Cooper_Run Truss TG03 Truss Type Common Girder Qty 1 Ply 2 6 Cooper Run Job Reference (optional) I38108302 8.240 s Jul 14 2019 MiTek Industries, Inc. Fri Aug 9 10:20:06 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:VarUFZKVo2kjotTWURxEQNyoteT-jP1tn?fl8e0PqSJ65dJhvCkA9gSQVEJMRZU9ojypcPN Scale = 1:37.0 1 2 3 4 5 6 7 15 14 13 12 11 10 9 8 16 17 18 19 20 21 22 10x10 6x6 10x10 5x10 MT18HS 10x10 4x8 8x8 3x6 8x8 4x8 8x8 3x6 8x8 3-5-8 3-5-8 6-7-8 3-2-0 9-9-8 3-2-0 12-11-8 3-2-0 16-1-8 3-2-0 19-7-0 3-5-8 3-5-8 3-5-8 6-7-8 3-2-0 9-9-8 3-2-0 12-11-8 3-2-0 16-1-8 3-2-0 19-7-0 3-5-8 0-11-05-9-120-11-06.00 12 Plate Offsets (X,Y)-- [1:0-3-12,0-3-4], [7:0-3-12,0-3-4], [8:0-3-4,0-1-10], [9:0-3-8,0-4-0], [10:0-3-8,0-4-0], [12:0-3-8,0-4-0], [14:0-3-8,0-4-0], [15:0-3-4,0-1-10] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-SH 0.66 0.53 0.93 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.13 -0.29 0.06 (loc) 11-12 11-12 8 l/defl >999 >782 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 224 lb FT = 20% GRIP 169/123 244/190 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SP 2400F 2.0E WEBS 2x4 SPF-S Stud *Except* 4-11,1-14,7-9: 2x4 SPF No.2, 1-15,7-8: 2x8 SP 2400F 2.0E BRACING- TOP CHORD Structural wood sheathing directly applied or 3-2-10 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)15=7905/0-5-8 (req. 0-6-3), 8=7453/0-5-8 (req. 0-5-14) Max Horz 15=-66(LC 3) Max Uplift 15=-367(LC 5), 8=-343(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-10537/501, 2-3=-10037/495, 3-4=-8118/428, 4-5=-8118/428, 5-6=-10009/493, 6-7=-10468/496, 1-15=-6413/317, 7-8=-6403/315 BOT CHORD 14-15=-136/2053, 12-14=-450/9355, 11-12=-396/8956, 10-11=-359/8931, 9-10=-401/9294, 8-9=-85/1898 WEBS 4-11=-329/6991, 5-11=-2673/180, 5-10=-108/2725, 6-10=-477/62, 6-9=-11/425, 3-11=-2713/183, 3-12=-111/2768, 2-12=-522/66, 2-14=-15/468, 1-14=-321/7467, 7-9=-323/7563 NOTES-(13-14) 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc, 2x8 - 2 rows staggered at 0-9-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-5-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc, Except member 6-9 2x4 - 1 row at 0-7-0 oc, member 2-14 2x4 - 1 row at 0-7-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 5) All plates are MT20 plates unless otherwise indicated. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) WARNING: Required bearing size at joint(s) 15, 8 greater than input bearing size. 9) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 15=367, 8=343. 11) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. Continued on page 2 August 9,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 6_Cooper_Run Truss TG03 Truss Type Common Girder Qty 1 Ply 2 6 Cooper Run Job Reference (optional) I38108302 8.240 s Jul 14 2019 MiTek Industries, Inc. Fri Aug 9 10:20:06 2019 Page 2 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:VarUFZKVo2kjotTWURxEQNyoteT-jP1tn?fl8e0PqSJ65dJhvCkA9gSQVEJMRZU9ojypcPN NOTES-(13-14) 12) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 1539 lb down and 71 lb up at 1-5-12, 1539 lb down and 71 lb up at 3-5-12, 1539 lb down and 71 lb up at 5-5-12, 1539 lb down and 71 lb up at 7-5-12, 1539 lb down and 71 lb up at 9-5-12, 1539 lb down and 71 lb up at 11-5-12, 1539 lb down and 71 lb up at 13-5-12, and 1539 lb down and 71 lb up at 15-5-12, and 1528 lb down and 68 lb up at 17-5-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 13) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 14) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced) + Uninhab. Attic Storage: Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-4=-60, 4-7=-60, 8-15=-20 Concentrated Loads (lb) Vert: 13=-1539(F) 14=-1539(F) 16=-1539(F) 17=-1539(F) 18=-1539(F) 19=-1539(F) 20=-1539(F) 21=-1539(F) 22=-1528(F) 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 6_Cooper_Run Truss TG04 Truss Type Roof Special Girder Qty 1 Ply 1 6 Cooper Run Job Reference (optional) I38108303 8.240 s Jul 14 2019 MiTek Industries, Inc. Fri Aug 9 10:20:07 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:VarUFZKVo2kjotTWURxEQNyoteT-BbbF_LgNvy8GRcuIfKqwSPHHO4jyEhaVfDEiKAypcPM Scale = 1:62.4 1 2 3 4 5 6 7 8 9 10 11 12 23 22 21 20 19 18 17 16 15 14 13 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 5x12 3x6 8x10 8x8 5x8 3x6 4x8 4x6 5x12 2x4 2x4 3x8 2x4 5x12 4x6 3x6 8x8 10x10 5x8 3-2-10 3-2-10 6-1-11 2-11-2 12-4-3 6-2-7 18-4-14 6-0-11 24-5-9 6-0-11 30-8-0 6-2-7 33-1-12 2-5-12 35-11-0 2-9-4 -1-0-0 1-0-0 3-2-10 3-2-10 6-1-11 2-11-2 12-4-3 6-2-7 18-4-14 6-0-11 24-5-9 6-0-11 30-8-0 6-2-7 33-1-12 2-5-12 35-11-0 2-9-4 36-11-0 1-0-0 1-0-04-7-01-1-04-7-07.00 12 8.00 12 Plate Offsets (X,Y)-- [4:0-9-0,0-1-12], [9:0-5-12,0-1-4], [13:Edge,0-8-2], [13:0-1-12,0-0-0], [14:0-3-8,0-4-0], [22:0-3-8,0-2-0], [23:0-1-12,0-0-0], [23:Edge,0-6-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-SH 0.95 0.89 0.93 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.32 -0.58 0.12 (loc) 18-20 18-20 13 l/defl >999 >738 n/a L/d 240 180 n/a PLATES MT20 Weight: 178 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 4-20,6-20,6-16,9-16,2-22: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-3-14 oc purlins, except end verticals, and 2-0-0 oc purlins (2-1-13 max.): 4-9. BOT CHORD Structural wood sheathing directly applied or 5-7-14 oc bracing. REACTIONS.(lb/size)23=1955/0-3-8, 13=1993/0-3-8 Max Horz 23=-109(LC 3) Max Uplift 23=-572(LC 5), 13=-671(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2513/808, 3-4=-2755/1013, 4-5=-3801/1523, 5-6=-3801/1523, 6-8=-3689/1516, 8-9=-3690/1516, 9-10=-2563/1018, 10-11=-2251/822, 2-23=-1853/571, 11-13=-1885/655 BOT CHORD 21-22=-751/2115, 20-21=-900/2363, 18-20=-1719/4227, 16-18=-1719/4227, 15-16=-806/2124, 14-15=-624/1816 WEBS 3-22=-458/227, 3-21=-281/393, 4-20=-816/1768, 5-20=-517/339, 6-20=-546/276, 6-18=0/348, 6-16=-674/272, 8-16=-523/349, 9-16=-832/1911, 10-15=-285/485, 10-14=-567/241, 2-22=-599/1934, 11-14=-584/1695 NOTES-(12-13) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 23=572, 13=671. 8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. Continued on page 2 August 9,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 6_Cooper_Run Truss TG04 Truss Type Roof Special Girder Qty 1 Ply 1 6 Cooper Run Job Reference (optional) I38108303 8.240 s Jul 14 2019 MiTek Industries, Inc. Fri Aug 9 10:20:08 2019 Page 2 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:VarUFZKVo2kjotTWURxEQNyoteT-fn9eBhh?gGG73lSUD1L9?dqS8U3Bz8qfuszGtcypcPL NOTES-(12-13) 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 58 lb down and 78 lb up at 6-1-11, 56 lb down and 78 lb up at 8-2-7, 56 lb down and 78 lb up at 10-2-7, 56 lb down and 78 lb up at 12-2-7, 56 lb down and 78 lb up at 14-2-7, 56 lb down and 78 lb up at 16-2-7, 56 lb down and 78 lb up at 18-2-7, 56 lb down and 78 lb up at 20-2-7, 56 lb down and 78 lb up at 22-2-7, 56 lb down and 78 lb up at 24-2-7, 56 lb down and 78 lb up at 26-2-7, 56 lb down and 78 lb up at 28-2-7, and 56 lb down and 78 lb up at 29-4-14, and 58 lb down and 78 lb up at 30-8-0 on top chord, and 31 lb down at 2-0-12, 32 lb down at 4-0-12, 33 lb down at 5-1-10, 33 lb down and 16 lb up at 6-2-7, 33 lb down and 16 lb up at 8-2-7, 33 lb down and 16 lb up at 10-2-7, 33 lb down and 16 lb up at 12-2-7, 33 lb down and 16 lb up at 14-2-7, 33 lb down and 16 lb up at 16-2-7, 33 lb down and 16 lb up at 18-2-7, 33 lb down and 16 lb up at 20-2-7, 33 lb down and 16 lb up at 22-2-7, 33 lb down and 16 lb up at 24-2-7, 33 lb down and 16 lb up at 26-2-7, 33 lb down and 16 lb up at 28-2-7, 33 lb down and 16 lb up at 29-4-14, 33 lb down and 16 lb up at 30-7-4, and 33 lb down at 31-10-4, and 34 lb down and 17 lb up at 33-10-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 11) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 12) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 13) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 2-4=-60, 4-9=-60, 9-11=-60, 11-12=-60, 13-23=-20 Concentrated Loads (lb) Vert: 4=-39(F) 7=-39(F) 9=-39(F) 19=-22(F) 21=-22(F) 20=-22(F) 5=-39(F) 18=-22(F) 6=-39(F) 8=-39(F) 16=-22(F) 15=-22(F) 17=-22(F) 24=-39(F) 25=-39(F) 26=-39(F) 27=-39(F) 28=-39(F) 29=-39(F) 30=-39(F) 31=-39(F) 32=-18(F) 33=-22(F) 34=-22(F) 35=-22(F) 36=-22(F) 37=-22(F) 38=-22(F) 39=-22(F) 40=-22(F) 41=-22(F) 42=-22(F) 43=-19(F) 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 6_Cooper_Run Truss TG05 Truss Type Half Hip Girder Qty 1 Ply 1 6 Cooper Run Job Reference (optional) I38108304 8.240 s Jul 14 2019 MiTek Industries, Inc. Fri Aug 9 10:20:08 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:VarUFZKVo2kjotTWURxEQNyoteT-fn9eBhh?gGG73lSUD1L9?dqdOUCWzMIfuszGtcypcPL Scale = 1:13.7 1 2 3 6 7 4 8 9 5 4x6 2x4 3x4 1-1-3 1-1-3 3-11-5 2-10-1 4-0-0 0-0-11 -1-0-0 1-0-0 1-1-3 1-1-3 4-0-0 2-10-13 1-3-02-2-010.00 12 Plate Offsets (X,Y)-- [3:0-2-4,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-R 0.23 0.30 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.01 -0.04 0.05 (loc) 5-6 5-6 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 11 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF-S Stud WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins: 3-4. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)4=101/Mechanical, 6=225/0-3-8, 5=37/Mechanical Max Horz 6=51(LC 5) Max Uplift 4=-43(LC 4), 6=-51(LC 5) Max Grav 4=103(LC 10), 6=225(LC 1), 5=71(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(13-14) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 7) Refer to girder(s) for truss to truss connections. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4, 6. 9) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 11) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 66 lb down and 22 lb up at 1-1-3, and 39 lb down and 22 lb up at 3-1-15 on top chord, and 2 lb down and 12 lb up at 1-1-3, and 3 lb down and 12 lb up at 3-1-15 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 12) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 13) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 14) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 2-3=-60, 3-4=-60, 5-6=-20 Concentrated Loads (lb) Vert: 8=8(B) 9=2(B) August 9,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 6_Cooper_Run Truss TG08 Truss Type Common Girder Qty 1 Ply 2 6 Cooper Run Job Reference (optional) I38108305 8.240 s Jul 14 2019 MiTek Industries, Inc. Fri Aug 9 10:20:09 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:VarUFZKVo2kjotTWURxEQNyoteT-8_j0P1hdRZO_hv1hmltOXqMmluX?idZo7WjpP2ypcPK Scale = 1:57.2 1 2 3 4 5 6 7 15 14 13 12 11 10 9 8161718192021 10x16 4x8 10x16 6x8 10x10 4x8 8x8 3x6 8x8 4x8 8x8 3x6 8x8 3-4-5 3-4-5 6-5-3 3-0-13 9-6-0 3-0-13 12-6-13 3-0-13 15-7-11 3-0-13 19-0-0 3-4-5 3-4-5 3-4-5 6-5-3 3-0-13 9-6-0 3-0-13 12-6-13 3-0-13 15-7-11 3-0-13 19-0-0 3-4-5 1-3-09-2-01-3-010.00 12 Plate Offsets (X,Y)-- [1:0-2-4,0-2-8], [7:0-2-4,0-2-8], [8:0-2-5,0-2-13], [9:0-3-8,0-4-0], [10:0-3-8,0-4-0], [12:0-3-8,0-4-0], [14:0-3-8,0-4-0], [15:0-2-5,0-2-13] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-SH 0.32 0.34 0.83 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.08 -0.18 0.02 (loc) 10 10-11 8 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 292 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x8 SP 2400F 2.0E WEBS 2x4 SPF-S Stud *Except* 4-11,1-14,7-9: 2x4 SPF No.2, 1-15,7-8: 2x8 SP 2400F 2.0E BRACING- TOP CHORD Structural wood sheathing directly applied or 4-6-9 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)15=8392/0-3-8 (req. 0-6-9), 8=8465/0-3-8 (req. 0-6-10) Max Horz 15=-212(LC 3) Max Uplift 15=-385(LC 5), 8=-378(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-7113/352, 2-3=-6685/375, 3-4=-5525/371, 4-5=-5525/371, 5-6=-6688/374, 6-7=-7128/347, 1-15=-6100/296, 7-8=-6104/292 BOT CHORD 14-15=-223/930, 12-14=-304/5408, 11-12=-246/5095, 10-11=-180/5098, 9-10=-216/5419, 8-9=-42/958 WEBS 4-11=-409/6778, 5-11=-1954/190, 5-10=-115/2339, 6-10=-512/100, 6-9=-39/533, 3-11=-1948/192, 3-12=-117/2331, 2-12=-499/104, 2-14=-44/516, 1-14=-189/4716, 7-9=-188/4698 NOTES-(12-13) 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc, 2x8 - 2 rows staggered at 0-9-0 oc. Bottom chords connected as follows: 2x8 - 2 rows staggered at 0-6-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) WARNING: Required bearing size at joint(s) 15, 8 greater than input bearing size. 8) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 15=385, 8=378. 10) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. Continued on page 2 August 9,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 6_Cooper_Run Truss TG08 Truss Type Common Girder Qty 1 Ply 2 6 Cooper Run Job Reference (optional) I38108305 8.240 s Jul 14 2019 MiTek Industries, Inc. Fri Aug 9 10:20:10 2019 Page 2 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:VarUFZKVo2kjotTWURxEQNyoteT-cAHOcNiFCtWrI3ctKSOd42vxUIsER3pxMASNxVypcPJ NOTES-(12-13) 11) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 1549 lb down and 71 lb up at 0-3-10, 1519 lb down and 80 lb up at 2-6-12, 1539 lb down and 71 lb up at 4-6-12, 1539 lb down and 71 lb up at 6-6-12, 1539 lb down and 71 lb up at 8-6-12, 1539 lb down and 71 lb up at 10-6-12, 1539 lb down and 71 lb up at 12-6-12, 1539 lb down and 71 lb up at 14-6-12, and 1539 lb down and 71 lb up at 16-6-12, and 1545 lb down and 68 lb up at 18-8-6 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 12) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 13) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced) + Uninhab. Attic Storage: Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-4=-60, 4-7=-60, 8-15=-20 Concentrated Loads (lb) Vert: 15=-1549(F) 10=-1539(F) 12=-1539(F) 8=-1545(F) 16=-1519(F) 17=-1539(F) 18=-1539(F) 19=-1539(F) 20=-1539(F) 21=-1539(F) 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 6_Cooper_Run Truss V01 Truss Type GABLE Qty 1 Ply 1 6 Cooper Run Job Reference (optional) I38108306 8.240 s Jul 14 2019 MiTek Industries, Inc. Fri Aug 9 10:20:10 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:VarUFZKVo2kjotTWURxEQNyoteT-cAHOcNiFCtWrI3ctKSOd42vsmIkVRFoxMASNxVypcPJ Scale = 1:15.0 1 2 3 2x4 2x4 2x4 7-6-10 7-6-10 0-0-42-2-73.50 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.69 0.84 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 16 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF-S Stud WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 7-6-10 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 7-2-4 oc bracing. REACTIONS.(lb/size)1=255/7-6-10, 3=255/7-6-10 Max Horz 1=62(LC 5) Max Uplift 1=-18(LC 4), 3=-26(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8-9) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 9,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 6_Cooper_Run Truss V02 Truss Type GABLE Qty 1 Ply 1 6 Cooper Run Job Reference (optional) I38108307 8.240 s Jul 14 2019 MiTek Industries, Inc. Fri Aug 9 10:20:11 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:VarUFZKVo2kjotTWURxEQNyoteT-4MrmqjjuzBehwDB3uAvscFS6hhGQAi95aqCwTxypcPI Scale: 1/2"=1' 1 2 3 4 5 8 7 63x4 3x6 3x4 2x4 2x4 2x4 2x4 2x4 13-8-14 13-8-14 6-10-7 6-10-7 13-8-14 6-10-7 0-0-43-5-40-0-46.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-SH 0.36 0.09 0.06 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 31 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 13-8-14. (lb) - Max Horz 1=-31(LC 4) Max Uplift All uplift 100 lb or less at joint(s) 8, 6 Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 7=284(LC 1), 8=304(LC 10), 6=304(LC 11) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8, 6. 8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 9,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 6_Cooper_Run Truss V03 Truss Type GABLE Qty 1 Ply 1 6 Cooper Run Job Reference (optional) I38108308 8.240 s Jul 14 2019 MiTek Industries, Inc. Fri Aug 9 10:20:11 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:VarUFZKVo2kjotTWURxEQNyoteT-4MrmqjjuzBehwDB3uAvscFS4_hDMAiR5aqCwTxypcPI Scale = 1:15.8 1 2 3 4 2x4 3x4 2x4 2x4 8-4-14 8-4-14 4-2-7 4-2-7 8-4-14 4-2-7 0-0-42-1-40-0-46.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.47 0.29 0.04 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 15 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=151/8-4-14, 3=151/8-4-14, 4=296/8-4-14 Max Horz 1=-18(LC 4) Max Uplift 1=-22(LC 6), 3=-25(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 9,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 6_Cooper_Run Truss V04 Truss Type GABLE Qty 1 Ply 1 6 Cooper Run Job Reference (optional) I38108309 8.240 s Jul 14 2019 MiTek Industries, Inc. Fri Aug 9 10:20:12 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:VarUFZKVo2kjotTWURxEQNyoteT-YZO813kWkUmYYNmGStQ59T_KP5ZXv7yEpUxT0NypcPH Scale = 1:42.0 1 2 3 4 5 9 8 7 610113x4 4x6 3x4 3x4 2x4 2x4 2x4 2x4 2x4 16-3-9 16-3-9 8-1-12 8-1-12 16-3-9 8-1-12 0-0-46-9-80-0-410.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-SH 0.17 0.29 0.15 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 46 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 16-3-9. (lb) - Max Horz 1=-151(LC 4) Max Uplift All uplift 100 lb or less at joint(s) 1 except 9=-135(LC 6), 6=-135(LC 7) Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 7=396(LC 1), 9=422(LC 10), 6=422(LC 11) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-9=-277/178, 4-6=-277/177 NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1 except (jt=lb) 9=135, 6=135. 8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 9,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 6_Cooper_Run Truss V05 Truss Type GABLE Qty 1 Ply 1 6 Cooper Run Job Reference (optional) I38108310 8.240 s Jul 14 2019 MiTek Industries, Inc. Fri Aug 9 10:20:13 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:VarUFZKVo2kjotTWURxEQNyoteT-0lyXFPl8VouP9XLS?bxKigXS0VxDeaWO28h1YpypcPG Scale = 1:37.6 1 2 3 4 5 8 7 69103x4 5x6 3x4 2x4 2x4 2x4 2x4 2x4 14-5-15 14-5-15 7-3-0 7-3-0 14-5-15 7-3-0 0-0-46-0-80-0-410.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-SH 0.37 0.13 0.13 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 39 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 14-5-15. (lb) - Max Horz 1=-134(LC 4) Max Uplift All uplift 100 lb or less at joint(s) 1 except 8=-122(LC 6), 6=-122(LC 7) Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 7=392(LC 1), 8=352(LC 10), 6=352(LC 11) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1 except (jt=lb) 8=122, 6=122. 8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 9,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 6_Cooper_Run Truss V06 Truss Type GABLE Qty 1 Ply 1 6 Cooper Run Job Reference (optional) I38108311 8.240 s Jul 14 2019 MiTek Industries, Inc. Fri Aug 9 10:20:14 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:VarUFZKVo2kjotTWURxEQNyoteT-UxWvSklmG60GngweZISZEu4b8vG7N0AXGoQa4GypcPF Scale = 1:66.6 1 2 3 4 5 6 7 8 9 10 19 18 17 16 15 14 13 12 113x4 3x6 3x6 2x4 4x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 13-2-11 13-2-11 11-11-15 11-11-15 13-2-11 1-2-12 0-0-49-11-158-11-1010.00 12 Plate Offsets (X,Y)-- [10:0-3-4,Edge], [11:Edge,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-SH 0.47 0.22 0.23 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 11 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 77 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 9-10: 2x3 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 10-11, 9-12, 8-13 REACTIONS.All bearings 13-2-11. (lb) - Max Horz 1=332(LC 5) Max Uplift All uplift 100 lb or less at joint(s) 1, 11, 12, 13, 14, 15, 16, 17, 18, 19 Max Grav All reactions 250 lb or less at joint(s) 1, 11, 12, 13, 14, 15, 16, 17, 18, 19 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-329/171, 2-3=-284/159, 3-4=-256/158 WEBS 9-12=-275/155 NOTES-(10-11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) The Fabrication Tolerance at joint 10 = 4% 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 11, 12, 13, 14, 15, 16, 17, 18, 19. 9) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 9,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 6_Cooper_Run Truss V07 Truss Type GABLE Qty 1 Ply 1 6 Cooper Run Job Reference (optional) I38108312 8.240 s Jul 14 2019 MiTek Industries, Inc. Fri Aug 9 10:20:14 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:VarUFZKVo2kjotTWURxEQNyoteT-UxWvSklmG60GngweZISZEu4d2vH0N1DXGoQa4GypcPF Scale = 1:53.7 1 2 3 4 5 9 8 7 63x4 3x6 3x6 2x4 4x6 2x4 2x4 2x4 2x4 11-7-8 11-7-8 10-4-12 10-4-12 11-7-8 1-2-12 0-0-48-7-157-7-1010.00 12 Plate Offsets (X,Y)-- [5:0-3-4,0-0-0], [6:Edge,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-SH 0.35 0.16 0.16 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 6 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 47 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 4-5: 2x3 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 6-0-0 oc bracing. WEBS 1 Row at midpt 4-7 REACTIONS.All bearings 11-7-8. (lb) - Max Horz 1=285(LC 5) Max Uplift All uplift 100 lb or less at joint(s) 1, 6, 7, 9 except 8=-128(LC 6) Max Grav All reactions 250 lb or less at joint(s) 1, 6 except 7=353(LC 1), 8=439(LC 10), 9=251(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-289/153 WEBS 3-8=-270/182 NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 6, 7, 9 except (jt=lb) 8=128. 8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 9,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 6_Cooper_Run Truss V08 Truss Type GABLE Qty 1 Ply 1 6 Cooper Run Job Reference (optional) I38108313 8.240 s Jul 14 2019 MiTek Industries, Inc. Fri Aug 9 10:20:15 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:VarUFZKVo2kjotTWURxEQNyoteT-y84Hf4mO1P87PqVr70zon5cpFJbo6TogVSA8diypcPE Scale = 1:45.2 1 2 3 4 7 6 53x4 3x4 2x4 2x4 4x6 2x4 2x4 10-0-4 10-0-4 8-9-8 8-9-8 10-0-4 1-2-12 0-0-47-3-156-3-1010.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-SH 0.26 0.32 0.21 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 36 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 3-4: 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 6-0-0 oc bracing. REACTIONS.All bearings 10-0-4. (lb) - Max Horz 1=239(LC 5) Max Uplift All uplift 100 lb or less at joint(s) 1, 5, 6 except 7=-148(LC 6) Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 6=336(LC 1), 7=490(LC 10) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-7=-303/202 NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5, 6 except (jt=lb) 7=148. 8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 9,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 6_Cooper_Run Truss V09 Truss Type GABLE Qty 1 Ply 1 6 Cooper Run Job Reference (optional) I38108314 8.240 s Jul 14 2019 MiTek Industries, Inc. Fri Aug 9 10:20:22 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:VarUFZKVo2kjotTWURxEQNyoteT-FU?w7UrnNZ18kvXB1_bRZZPyU7_HFg4i62M?MoypcP7 Scale = 1:38.8 1 2 3 4 7 6 582x4 3x4 2x4 2x4 2x4 2x4 2x4 8-5-1 8-5-1 7-2-5 7-2-5 8-5-1 1-2-12 0-0-45-11-154-11-1010.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.45 0.26 0.11 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 26 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 8-5-1. (lb) - Max Horz 1=193(LC 5) Max Uplift All uplift 100 lb or less at joint(s) 1, 5, 6 except 7=-130(LC 6) Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 6=306(LC 1), 7=373(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-7=-264/187 NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5, 6 except (jt=lb) 7=130. 8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 9,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 6_Cooper_Run Truss V10 Truss Type GABLE Qty 1 Ply 1 6 Cooper Run Job Reference (optional) I38108315 8.240 s Jul 14 2019 MiTek Industries, Inc. Fri Aug 9 10:20:27 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:VarUFZKVo2kjotTWURxEQNyoteT-cRopBBvwC5fQrgP8qXBcGd6in8eKwxaSGK4m2?ypcP2 Scale = 1:30.3 1 2 3 5 42x4 2x4 2x4 2x4 4x6 6-9-14 6-9-14 5-7-2 5-7-2 6-9-14 1-2-12 0-0-44-7-153-7-1010.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.92 0.46 0.09 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 4 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 20 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud *Except* 2-3: 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=199/6-9-14, 4=-6/6-9-14, 5=316/6-9-14 Max Horz 1=145(LC 5) Max Uplift 1=-7(LC 6), 4=-68(LC 2), 5=-23(LC 5) Max Grav 1=199(LC 1), 4=6(LC 5), 5=316(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 4, 5. 8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 9,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 6_Cooper_Run Truss V11 Truss Type GABLE Qty 1 Ply 1 6 Cooper Run Job Reference (optional) I38108316 8.240 s Jul 14 2019 MiTek Industries, Inc. Fri Aug 9 10:20:29 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:VarUFZKVo2kjotTWURxEQNyoteT-YqwabtxAkjv84_ZXxyD4L2B9cyNcOrtkjeZt6uypcP0 Scale = 1:22.4 1 2 3 5 4 2x4 3x4 2x4 2x4 2x4 5-2-11 5-2-11 3-11-15 3-11-15 5-2-11 1-2-12 0-0-43-3-152-3-1010.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.46 0.22 0.04 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 4 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 14 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-2-11 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=141/5-2-11, 4=21/5-2-11, 5=225/5-2-11 Max Horz 1=98(LC 5) Max Uplift 1=-10(LC 7), 4=-44(LC 7), 5=-16(LC 5) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 4, 5. 8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 9,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 6_Cooper_Run Truss V12 Truss Type Valley Qty 1 Ply 1 6 Cooper Run Job Reference (optional) I38108317 8.240 s Jul 14 2019 MiTek Industries, Inc. Fri Aug 9 10:20:29 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:VarUFZKVo2kjotTWURxEQNyoteT-YqwabtxAkjv84_ZXxyD4L2BFDyPLOrVkjeZt6uypcP0 Scale = 1:12.8 1 2 3 4 2x4 2x4 2x4 2x4 3-7-8 3-7-8 2-4-12 2-4-12 3-7-8 1-2-12 0-0-41-11-150-11-1010.00 12 Plate Offsets (X,Y)-- [2:0-2-0,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-R 0.10 0.11 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 4 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 7 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-7-8 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=129/3-7-3, 4=129/3-7-3 Max Horz 1=51(LC 5) Max Uplift 1=-4(LC 6), 4=-7(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 4. 8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 9,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 6_Cooper_Run Truss V13 Truss Type GABLE Qty 1 Ply 1 6 Cooper Run Job Reference (optional) I38108318 8.240 s Jul 14 2019 MiTek Industries, Inc. Fri Aug 9 10:20:30 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:VarUFZKVo2kjotTWURxEQNyoteT-00UypDyoU01?i88jVflJuFkLYMjn7GKuyIIQeKypcP? Scale = 1:53.6 1 2 3 4 5 6 7 8 9 17 16 15 14 13 12 11 103x4 3x8 3x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 11-3-5 11-3-5 0-0-49-4-1310.00 12 Plate Offsets (X,Y)-- [9:0-4-2,Edge], [10:Edge,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-SH 0.44 0.22 0.16 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 10 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 61 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 9-10 REACTIONS.All bearings 11-3-5. (lb) - Max Horz 1=270(LC 5) Max Uplift All uplift 100 lb or less at joint(s) 1, 10, 11, 12, 13, 14, 15, 16, 17 Max Grav All reactions 250 lb or less at joint(s) 1, 10, 11, 12, 13, 14, 15, 16, 17 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-268/146 NOTES-(8-9) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 10, 11, 12, 13, 14, 15, 16, 17. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 9,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 6_Cooper_Run Truss V14 Truss Type GABLE Qty 1 Ply 1 6 Cooper Run Job Reference (optional) I38108319 8.240 s Jul 14 2019 MiTek Industries, Inc. Fri Aug 9 10:20:31 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:VarUFZKVo2kjotTWURxEQNyoteT-UD2K0YyQFK9sKIjv3NGYQTHXFl2asjl1By2_BnypcP_ Scale = 1:47.5 1 2 3 4 7 6 52x4 3x6 2x4 2x4 2x4 2x4 2x4 9-10-9 9-10-9 0-0-48-2-1310.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-SH 0.38 0.32 0.14 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 33 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x3 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 4-5 REACTIONS.All bearings 9-10-9. (lb) - Max Horz 1=237(LC 5) Max Uplift All uplift 100 lb or less at joint(s) 1, 5, 7 except 6=-124(LC 6) Max Grav All reactions 250 lb or less at joint(s) 1, 5, 7 except 6=457(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 3-6=-270/162 NOTES-(8-9) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5, 7 except (jt=lb) 6=124. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 9,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 6_Cooper_Run Truss V15 Truss Type GABLE Qty 1 Ply 1 6 Cooper Run Job Reference (optional) I38108320 8.240 s Jul 14 2019 MiTek Industries, Inc. Fri Aug 9 10:20:32 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:VarUFZKVo2kjotTWURxEQNyoteT-yPciEuz30eIjxSI6d4nnzgpdy9NObBkBPbnXiDypcOz Scale = 1:43.1 1 2 3 5 462x4 2x4 2x4 2x4 2x4 8-5-12 8-5-12 0-0-47-0-1310.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.64 0.34 0.10 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 4 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 27 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x3 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=118/8-5-12, 4=183/8-5-12, 5=480/8-5-12 Max Horz 1=201(LC 5) Max Uplift 1=-23(LC 4), 4=-43(LC 5), 5=-141(LC 6) Max Grav 1=124(LC 5), 4=183(LC 1), 5=480(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-5=-300/213 NOTES-(8-9) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 4 except (jt=lb) 5=141. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 9,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 6_Cooper_Run Truss V16 Truss Type GABLE Qty 1 Ply 1 6 Cooper Run Job Reference (optional) I38108321 8.240 s Jul 14 2019 MiTek Industries, Inc. Fri Aug 9 10:20:34 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:VarUFZKVo2kjotTWURxEQNyoteT-vojTfa?JYFYRBlSUkVpF25v1Tz4k36uTtvGem6ypcOx Scale = 1:36.1 1 2 3 5 462x4 2x4 2x4 2x4 2x4 7-0-15 7-0-15 0-0-45-10-1310.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.45 0.29 0.05 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 4 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 19 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=60/7-0-15, 4=182/7-0-15, 5=381/7-0-15 Max Horz 1=168(LC 5) Max Uplift 1=-32(LC 4), 4=-38(LC 5), 5=-121(LC 6) Max Grav 1=106(LC 5), 4=182(LC 1), 5=381(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-5=-256/187 NOTES-(8-9) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 4 except (jt=lb) 5=121. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 9,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 6_Cooper_Run Truss V17 Truss Type GABLE Qty 1 Ply 1 6 Cooper Run Job Reference (optional) I38108322 8.240 s Jul 14 2019 MiTek Industries, Inc. Fri Aug 9 10:20:35 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:VarUFZKVo2kjotTWURxEQNyoteT-N_Hrsw0xJZgIov1hICKUbJRBrMRkoZHd6Z0BJYypcOw Scale = 1:27.4 1 2 3 5 42x4 2x4 2x4 2x4 2x4 5-8-2 5-8-2 0-0-44-8-1310.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.41 0.24 0.05 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 4 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 15 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-8-2 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=-28/5-8-2, 4=126/5-8-2, 5=325/5-8-2 Max Horz 1=133(LC 5) Max Uplift 1=-55(LC 4), 4=-32(LC 5), 5=-115(LC 6) Max Grav 1=95(LC 6), 4=126(LC 1), 5=325(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8-9) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 4 except (jt=lb) 5=115. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 9,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 6_Cooper_Run Truss V18 Truss Type Valley Qty 1 Ply 1 6 Cooper Run Job Reference (optional) I38108323 8.240 s Jul 14 2019 MiTek Industries, Inc. Fri Aug 9 10:20:36 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:VarUFZKVo2kjotTWURxEQNyoteT-rArD4G0Z4so8Q3btswsj7W_L7mluX0EmKDllr_ypcOv Scale = 1:20.8 1 2 3 2x4 2x4 2x4 4-3-5 4-3-5 0-0-43-6-1310.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.50 0.31 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 10 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-3-5 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=155/4-3-1, 3=155/4-3-1 Max Horz 1=98(LC 5) Max Uplift 3=-34(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8-9) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 9,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 6_Cooper_Run Truss V19 Truss Type Valley Qty 1 Ply 1 6 Cooper Run Job Reference (optional) I38108324 8.240 s Jul 14 2019 MiTek Industries, Inc. Fri Aug 9 10:20:38 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:VarUFZKVo2kjotTWURxEQNyoteT-nZz_Uy2pcU2sfNlFzLuBCx3lEaUB?wj3oXErwtypcOt Scale = 1:15.0 1 2 3 2x4 2x4 2x4 2-10-9 2-10-9 0-0-42-4-1310.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.21 0.13 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 7 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-10-9 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=99/2-10-4, 3=99/2-10-4 Max Horz 1=62(LC 5) Max Uplift 3=-22(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8-9) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 9,2019 PRODUCT CODE APPROVALSLATERAL BRACING LOCATIONIndicates location where bearings(supports) occur. Icons vary butreaction section indicates jointnumber where bearings occur.Min size shown is for crushing only.Indicated by symbol shown and/orby text in the bracing section of theoutput. Use T or I bracingif indicated.The first dimension is the plate width measured perpendicular to slots. Second dimension isthe length parallel to slots.Center plate on joint unless x, yoffsets are indicated.Dimensions are in ft-in-sixteenths.Apply plates to both sides of trussand fully embed teeth.1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI.2. Truss bracing must be designed by an engineer. For wide truss spacing, individual lateral braces themselves may require bracing, or alternative Tor I bracing should be considered.3. Never exceed the design loading shown and never stack materials on inadequately braced trusses.4. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties.5. Cut members to bear tightly against each other.6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI 1.7. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI 1.8. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication.9. Unless expressly noted, this design is not applicable for use with fire retardant, preservative treated, or green lumber.10. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection.11. Plate type, size, orientation and location dimensions indicated are minimum plating requirements.12. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified.13. Top chords must be sheathed or purlins provided at spacing indicated on design.14. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted.15. Connections not shown are the responsibility of others.16. Do not cut or alter truss member or plate without prior approval of an engineer.17. Install and load vertically unless indicated otherwise.18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use.19. Review all portions of this design (front, back, words and pictures) before use. Reviewing pictures alone is not sufficient.20. Design assumes manufacture in accordance with ANSI/TPI 1 Quality Criteria.Failure to Follow Could Cause PropertyDamage or Personal Injury (Drawings not to scale)© 2012 MiTek® All Rights ReservedMiTek Engineering Reference Sheet: MII-7473 rev. 10/03/2015edge of truss.from outside"16/1-0ICC-ES Reports:ESR-1311, ESR-1352, ESR1988ER-3907, ESR-2362, ESR-1397, ESR-3282JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISEAROUND THE TRUSS STARTING AT THE JOINT FARTHEST TOTHE LEFT.CHORDS AND WEBS ARE IDENTIFIED BY END JOINTNUMBERS/LETTERS.W 4 - 6 W3-6W3 - 7 W2-7W1-7C1-8 C5-6C6-7C7-8C4-5 C3-4C2-3C1-2TOP CHORD TOP CHORD 87654321BOTTOM CHORDSTOP CHORDSBEARING4 x 4PLATE SIZEThis symbol indicates the required direction of slots inconnector plates."16/1For 4 x 2 orientation, locateplates 0- 1"4/3PLATE LOCATION AND ORIENTATIONSymbolsNumbering SystemGeneral Safety Notes *Plate location details available in MiTek 20/20software or upon request.Industry Standards:ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction.DSB-89: Design Standard for Bracing.BCSI: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses.6-4-8WEBSTrusses are designed for wind loads in the plane of the truss unless otherwise shown.Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others.dimensions shown in ft-in-sixteenths