HomeMy WebLinkAboutS000.2{\LOUTSIDE ELEVATION}{\LSECTION A-A THROUGH PIER}
{\LINSIDE ELEVATION}
SIMPSON MSTA49 STRAP, CENTERED @ BOTTOM OF HEADER.
IF PANEL SPLICE IS NEEDED IT SHALL OCCUR WITHIN\PMIDDLE 24" OF WALL HEIGHT. BLOCKING IS REQUIRED.\PIF 2x BLOCKING IS USED IT MUST BE STITCH NAILED\PWITH ONE ROW OF 16D SINKERS AT 3" O.C.
FASTEN SHEATHING TO HEADER WITH 8D COMMON\PNAILS IN 3" GRID PATTERN AS SHOWN AND 3" O.C.\PIN ALL FRAMING (STUDS & SILLS) TYP.
1/2" DIA. ANCHOR BOLT W/ 7" MIN. EMBEDMENT & 2"x2"x3/16" PLATE WASHER, TYP.SEE TYP. CORNER FRAMING DETAIL
SIMPSON MSTA49 STRAP, OPPOSITE SIDE OF SHEATHING. (SEE SECTION A-A) TYP. INSTALL PER MANUF. SPEC.
FASTEN TOP PLATE TO HEADER W/ \PTWO ROWS OF 16D NAILS @ 3" O.C.
\A1;3"x11 {\H0.7x;\S1#4;\H1.429x;" MIN. HEADER (SEE PLANS)}
16d SINKER NAILS IN (2) ROWS @ 3"O.C.
\A1;NOTE: ALL SHEATHABLE AREAS OF EXTERIOR WALLS FULLY SHEATHED WITH {\H0.7x;\S1#2;\H1.429x;" PLYWOOD OR \H0.7x;\S7#16;\H1.429x;" OSB}
{\LPLAN VIEW OF CORNER DETAIL}PORTAL FRAME\PWALL SEGMENT (TYP.)
16d NAIL AT \P12" O.C.
ANCHOR BOLTS PER CODE, (2 MIN.)
MIN. 2"x2"x3/16" PLATE WASHER
\A1;10'-0" MAX.\PTO TOP OF HEADER \A1;{\Farchquik.shx;2'-0" < FINISHED WIDTH < 18'-0"}\A1;{\Farchquik.shx;MIN. WIDTH BASED ON 6:1\PHEIGHT-TO-WIDTH ASPECT RATIO\PFOR EXAMPLE: 16" MIN. FOR 8' HEIGHT}
\A1;{\Farchquik.shx;EXTENT OF HEADER}
BLOCKING AS REQ'D FOR SHEATH'G SPLICE
\A1;10'-0" MAX.\PTO TOP OF HEADER
\A1;{\Farchquik.shx;2'-0" < FINISHED WIDTH < 18'-0"}
BOTH SIDES OF GARAGE DOORSCALE: N.T.S.
GARAGE PORTAL FRAME BRACING ELEVATION
SHEATHING FILLER\PAS REQ'D
{\Farchquik.shx;A}
{\Farchquik.shx;A}
A
8D NAIL @ \P6" O.C. IN ALL\PPANEL EDGES\PNOT PART OF\PPORTAL FRAME
JACK\PSTUD
KING\PSTUD
\A1;{\H0.7x;\S7#16;}" OSB OR {\H0.7x;\S1#2;}" PLYWOOD SHEATHING. WOOD STRUCT. PANEL MUST BE CONTIN. FROM TOP TO BOTTOM OF WALL, OR FROM TOP OF WALL TO PERMITTED SPLICE AREA
\A1;PONY\A1;WALL \P(3'-0"MAX.)
\A1;12' MAX. WALL HEIGHT
FASTEN HEADER TO KINGS STUDS W/ (6) 16d SINKERS
MIN. (2) JACK STUDS OR AS NOTED ON PLANS
\A1;{\Farchquik.shx;EXTENT OF HEADER}
\A1;PONY\A1;WALL\P(3'-0" MAX)
\A1;12' MAX. WALL HEIGHT
\A1;3"x11 {\H0.7x;\S1#4;\H1.429x;" MIN. HEADER (SEE PLANS)}
MIN. (2) JACK STUDS OR AS NOTED ON PLANS
HEADER TO BE LOCATED @ TOP OF OPENING
\A1;STRAP END \PLENGTH
\A1;STRAP END \PLENGTH
HEADER TO BE LOCATED @ TOP OF OPENING copyright : MULHERN & KULPStructural Engineering, Inc.cissue date:
drawn by:
project mgr:
M&K project number:
initial:
REVISIONS:
date:
3-14-14
JGF
JE
125-13021
Castleton ModelMidwest Zonesheet:1900 East Golf Road, Suite 300Schaumburg, Illinois 60173Pulte Midwest ZoneBase - 18 psf Roof LiveJEMOVED P.C. IN BSMT. TO AVOID BATH 7 DOORWAY07/24/2014VRF2X12 FIRST FLOOR DESIGN10/08/2014AAMREVISED OPT. GAME ROOM FRAMING DEPTH10/27/2014NJDARCH REVISIONS02/23/2016PORTAL FRAME DETAILS-4.0
09/17/19
Adam Schriner