Loading...
HomeMy WebLinkAboutI38309380.4_Copper_Run16023 Swingley Ridge Rd Chesterfield, MO 63017 314-434-1200 MiTek USA, Inc. Re: The truss drawing(s) referenced below have been prepared by MiTek USA, Inc. under my direct supervision based on the parameters provided by ProBuild (CarterLee Bldg Components). August 26,2019 Liu, Xuegang Pages or sheets covered by this seal: I38309380 thru I38309447 My license renewal date for the state of Indiana is July 31, 2020. 4_Copper_Run 4 Copper Run IMPORTANT NOTE: The seal on these truss component designs is a certification that the engineer named is licensed in the jurisdiction(s) identified and that the designs comply with ANSI/TPI 1. These designs are based upon parameters shown (e.g., loads, supports, dimensions, shapes and design codes), which were given to MiTek or TRENCO. Any project specific information included is for MiTek's or TRENCO's customers file reference purpose only, and was not taken into account in the preparation of these designs. MiTek or TRENCO has not independently verified the applicability of the design parameters or the designs for any particular building. Before use, the building designer should verify applicability of design parameters and properly incorporate these designs into the overall building design per ANSI/TPI 1, Chapter 2. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Copper_Run Truss GE01 Truss Type COMMON SUPPORTED GAB Qty 1 Ply 1 4 Copper Run Job Reference (optional) I38309380 8.240 s Jul 14 2019 MiTek Industries, Inc. Mon Aug 26 12:35:25 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:30gw6Zi9UeCey_72UT9oFIyJDSk-YMkBhsLBe3FpmF07IVjfzZlGBiwSchXvRVrjbmyjzqW Scale = 1:40.4 Sheet Front Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 33 32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 3x8 4x6 3x8 3x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 19-7-0 19-7-0 -0-11-0 0-11-0 9-9-8 9-9-8 19-7-0 9-9-8 20-6-0 0-11-0 0-9-35-7-150-9-36.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-R 0.09 0.03 0.06 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.00 0.00 (loc) 17 17 18 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 208 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS.All bearings 19-7-0. (lb) - Max Horz 33=-59(LC 7) Max Uplift All uplift 100 lb or less at joint(s) 33, 18, 26, 28, 29, 30, 31, 32, 24, 23, 22, 21, 20, 19 Max Grav All reactions 250 lb or less at joint(s) 33, 18, 25, 26, 28, 29, 30, 31, 32, 24, 23, 22, 21, 20, 19 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(11-12) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 6) Gable studs spaced at 1-4-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 33, 18, 26, 28, 29, 30, 31, 32, 24, 23, 22, 21, 20, 19. 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Copper_Run Truss GE02 Truss Type MONOPITCH SUPPORTED Qty 1 Ply 1 4 Copper Run Job Reference (optional) I38309381 8.240 s Jul 14 2019 MiTek Industries, Inc. Mon Aug 26 12:35:26 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:30gw6Zi9UeCey_72UT9oFIyJDSk-0ZIavCMpPMNfOObJsCEuVmIRy6E3L8G3g9aG7CyjzqV Scale = 1:15.2 Sheet Front Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 9 8 7 6 3x6 2x4 2x4 2x4 2x4 2x4 2x4 -0-11-0 0-11-0 5-11-8 5-11-8 0-7-82-4-63.50 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-R 0.09 0.07 0.03 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.00 0.00 0.00 (loc) 1 1 6 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 37 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x6 SPF No.2 *Except* 5-6: 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-11-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 5-11-8. (lb) - Max Horz 9=71(LC 5) Max Uplift All uplift 100 lb or less at joint(s) 9, 6, 7, 8 Max Grav All reactions 250 lb or less at joint(s) 9, 6, 7, 8 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(9-10) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) Gable requires continuous bottom chord bearing. 4) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 5) Gable studs spaced at 1-4-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 9, 6, 7, 8. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Copper_Run Truss GE03 Truss Type MONOPITCH SUPPORTED Qty 1 Ply 1 4 Copper Run Job Reference (optional) I38309382 8.240 s Jul 14 2019 MiTek Industries, Inc. Mon Aug 26 12:35:27 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:30gw6Zi9UeCey_72UT9oFIyJDSk-Ulsy6YNRAgVW0YAWQwl72_rciVb34ayCupKqgeyjzqU Scale = 1:8.9 Sheet Back Full Sheathing 1 Ply 7/16OSB8 1 2 3 5 4 3x6 2x4 2x4 -0-11-0 0-11-0 2-0-0 2-0-0 0-7-81-2-83.50 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-R 0.09 0.02 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.00 -0.00 0.00 (loc) 1 1 4 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 10 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x6 SPF No.2 *Except* 3-4: 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS.(lb/size)5=159/2-0-0, 4=43/2-0-0 Max Horz 5=33(LC 5) Max Uplift 5=-50(LC 4), 4=-4(LC 5) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(10-11) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) Gable requires continuous bottom chord bearing. 4) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 5) Gable studs spaced at 1-4-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 4. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Copper_Run Truss GE04 Truss Type GABLE Qty 1 Ply 1 4 Copper Run Job Reference (optional) I38309383 8.240 s Jul 14 2019 MiTek Industries, Inc. Mon Aug 26 12:35:28 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:30gw6Zi9UeCey_72UT9oFIyJDSk-yxQKKuN4x_dNdili_dGMaBNnzvwYp1rL7T3NC4yjzqT Scale = 1:17.9 Sheet Front Full Sheathing 1 Ply 7/16OSB8 1 2 3 5 4 2x4 2x4 2x4 2x4 2x4 3-6-15 3-6-15 2-11-1210.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB Matrix-P 0.12 0.07 0.02 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 4 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 20 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-6-15 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=64/3-6-15, 4=26/3-6-15, 5=165/3-6-15 Max Horz 1=80(LC 5) Max Uplift 1=-4(LC 4), 4=-16(LC 5), 5=-58(LC 6) Max Grav 1=64(LC 1), 4=30(LC 4), 5=165(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(9-10) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) Gable requires continuous bottom chord bearing. 4) Gable studs spaced at 1-4-0 oc. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 4, 5. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Copper_Run Truss GE05 Truss Type Valley Qty 1 Ply 1 4 Copper Run Job Reference (optional) I38309384 8.240 s Jul 14 2019 MiTek Industries, Inc. Mon Aug 26 12:35:28 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:30gw6Zi9UeCey_72UT9oFIyJDSk-yxQKKuN4x_dNdili_dGMaBNo3vx6p1CL7T3NC4yjzqT Scale = 1:9.4 Sheet Back Full Sheathing 1 Ply 7/16OSB8 1 2 3 2x4 2x4 2x4 1-6-15 1-6-15 1-3-1210.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB Matrix-P 0.05 0.03 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 5 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 1-6-15 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=47/1-6-15, 3=47/1-6-15 Max Horz 1=30(LC 5) Max Uplift 3=-10(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(9-10) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) Gable requires continuous bottom chord bearing. 4) Gable studs spaced at 2-0-0 oc. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Copper_Run Truss J01 Truss Type JACK-CLOSED Qty 29 Ply 1 4 Copper Run Job Reference (optional) I38309385 8.240 s Jul 14 2019 MiTek Industries, Inc. Mon Aug 26 12:35:29 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:30gw6Zi9UeCey_72UT9oFIyJDSk-Q8_iXDOiiHlEFsKuXLob7PwwXJGxYUSVM7pwkXyjzqS Scale = 1:24.7 1 2 3 5 4 2x4 3x4 3x4 2x4 -0-11-0 0-11-0 3-10-8 3-10-8 1-1-34-3-154-0-70-3-84-3-1510.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB Matrix-R 0.20 0.12 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.01 -0.02 0.00 (loc) 4-5 4-5 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 16 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-10-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)5=217/0-3-8, 4=134/0-1-8 Max Horz 5=127(LC 5) Max Uplift 5=-15(LC 6), 4=-53(LC 5) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 4) Bearing at joint(s) 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 4. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 4. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Copper_Run Truss J01A Truss Type JACK-CLOSED Qty 4 Ply 1 4 Copper Run Job Reference (optional) I38309386 8.240 s Jul 14 2019 MiTek Industries, Inc. Mon Aug 26 12:35:30 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:30gw6Zi9UeCey_72UT9oFIyJDSk-vKX4lZPKTbt5t0v452JqgcT6njcBHxheanYUHzyjzqR Scale = 1:24.7 1 2 3 4 8 7 6 5 2x4 3x4 2x4 2x4 2x4 2x4 2x4 2-3-8 2-3-8 3-10-8 1-7-0 -0-11-0 0-11-0 2-3-8 2-3-8 3-10-8 1-7-0 1-1-34-3-153-4-70-11-83-7-150-8-010.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB Matrix-R 0.17 0.12 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.01 -0.02 0.00 (loc) 6 7 5 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 17 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 3-7: 2x3 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-10-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)8=217/0-3-8, 5=134/0-1-8 Max Horz 8=119(LC 5) Max Uplift 8=-14(LC 6), 5=-52(LC 5) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 4) Bearing at joint(s) 5 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 5. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8, 5. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Copper_Run Truss J01B Truss Type HALF HIP Qty 1 Ply 1 4 Copper Run Job Reference (optional) I38309387 8.240 s Jul 14 2019 MiTek Industries, Inc. Mon Aug 26 12:35:30 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:30gw6Zi9UeCey_72UT9oFIyJDSk-vKX4lZPKTbt5t0v452JqgcT6sjcDHxheanYUHzyjzqR Scale = 1:22.1 1 2 3 4 5 9 8 7 6 3x4 2x4 2x4 2x4 2x4 2x4 3x4 2x4 0-1-132-3-8 2-3-8 3-10-8 1-7-0 -0-11-0 0-11-0 2-3-8 2-3-8 3-3-0 0-11-8 3-10-8 0-7-8 1-1-33-7-143-9-112-8-60-11-82-11-140-8-03-7-1410.00 12 Plate Offsets (X,Y)-- [4:0-2-0,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB Matrix-R 0.16 0.12 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.01 -0.01 0.00 (loc) 7 8 6 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 16 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 3-8: 2x3 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-10-8 oc purlins, except end verticals, and 2-0-0 oc purlins: 4-5. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)9=217/0-3-8, 6=134/0-1-8 Max Horz 9=103(LC 5) Max Uplift 9=-22(LC 6), 6=-42(LC 5) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(10-11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 6) Bearing at joint(s) 6 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 6. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 9, 6. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Copper_Run Truss J01C Truss Type HALF HIP Qty 3 Ply 1 4 Copper Run Job Reference (optional) I38309388 8.240 s Jul 14 2019 MiTek Industries, Inc. Mon Aug 26 12:35:31 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:30gw6Zi9UeCey_72UT9oFIyJDSk-NW5TyvQyEv?yUAUHflq3Cq?HT7y_0OxopRI1pPyjzqQ Scale = 1:22.1 1 2 3 4 6 5 3x4 2x4 2x4 3x4 2x4 0-1-131-11-4 1-11-4 3-10-8 1-11-4 -0-11-0 0-11-0 3-3-0 3-3-0 3-10-8 0-7-8 1-1-33-7-143-9-113-4-60-3-83-7-1410.00 12 Plate Offsets (X,Y)-- [3:0-2-0,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB Matrix-R 0.17 0.09 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.01 -0.02 0.00 (loc) 5-6 5-6 5 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 15 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-10-8 oc purlins, except end verticals, and 2-0-0 oc purlins: 3-4. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)6=217/0-3-8, 5=134/0-1-8 Max Horz 6=111(LC 5) Max Uplift 6=-23(LC 6), 5=-43(LC 5) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(10-11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 6) Bearing at joint(s) 5 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 5. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 6, 5. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Copper_Run Truss J02 Truss Type JACK-OPEN Qty 4 Ply 1 4 Copper Run Job Reference (optional) I38309389 8.240 s Jul 14 2019 MiTek Industries, Inc. Mon Aug 26 12:35:31 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:30gw6Zi9UeCey_72UT9oFIyJDSk-NW5TyvQyEv?yUAUHflq3Cq?Hw7zM0OxopRI1pPyjzqQ Scale = 1:15.4 1 2 5 3 4 2x4 2x4 2-3-12 2-3-12 -0-11-0 0-11-0 2-3-12 2-3-12 0-11-32-5-112-0-82-5-118.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB Matrix-R 0.14 0.06 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.00 -0.00 (loc) 5 4-5 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 8 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 2-3-12 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)5=164/0-3-8, 3=49/Mechanical, 4=19/Mechanical Max Horz 5=85(LC 6) Max Uplift 5=-13(LC 6), 3=-34(LC 6), 4=-1(LC 6) Max Grav 5=164(LC 1), 3=49(LC 1), 4=39(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(6-7) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 3, 4. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Copper_Run Truss J03 Truss Type JACK-OPEN Qty 2 Ply 1 4 Copper Run Job Reference (optional) I38309390 8.240 s Jul 14 2019 MiTek Industries, Inc. Mon Aug 26 12:35:32 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:30gw6Zi9UeCey_72UT9oFIyJDSk-rjfr9FQa?C7p6J3TDTLIl1YRQWIZlrBx251aLsyjzqP Scale = 1:15.3 1 2 5 3 4 2x4 3x4 2-7-6 2-7-6 -1-5-10 1-5-10 2-7-6 2-7-6 1-1-32-5-82-0-132-5-86.25 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB Matrix-R 0.22 0.06 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.00 -0.00 (loc) 4-5 4-5 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 9 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 2-7-6 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)5=226/0-4-11, 3=46/Mechanical, 4=18/Mechanical Max Horz 5=88(LC 6) Max Uplift 5=-42(LC 6), 3=-27(LC 6) Max Grav 5=226(LC 1), 3=46(LC 1), 4=43(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(6-7) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 3. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Copper_Run Truss J04 Truss Type JACK-OPEN Qty 2 Ply 1 4 Copper Run Job Reference (optional) I38309391 8.240 s Jul 14 2019 MiTek Industries, Inc. Mon Aug 26 12:35:32 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:30gw6Zi9UeCey_72UT9oFIyJDSk-rjfr9FQa?C7p6J3TDTLIl1YRQWIZlrBx251aLsyjzqP Scale = 1:15.3 1 2 5 3 4 2x4 3x4 2-7-6 2-6-14 -1-5-10 1-5-10 2-7-6 2-7-6 1-1-32-5-82-0-132-5-86.25 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB Matrix-R 0.22 0.06 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.00 -0.00 (loc) 4-5 4-5 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 9 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 2-7-6 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)5=226/0-4-11, 3=46/Mechanical, 4=18/Mechanical Max Horz 5=88(LC 6) Max Uplift 5=-42(LC 6), 3=-27(LC 6) Max Grav 5=226(LC 1), 3=46(LC 1), 4=43(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(6-7) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 3. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Copper_Run Truss J05 Truss Type JACK-OPEN Qty 2 Ply 1 4 Copper Run Job Reference (optional) I38309392 8.240 s Jul 14 2019 MiTek Industries, Inc. Mon Aug 26 12:35:33 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:30gw6Zi9UeCey_72UT9oFIyJDSk-JvDDNbRCmWFgkTdfmAsXHF4dfwdWUIR5Hln8tIyjzqO Scale: 3/4"=1' 1 2 5 3 42x4 3x4 1-9-0 1-9-0 -0-11-0 0-11-0 1-9-0 1-9-0 1-1-32-6-112-0-142-6-1110.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB Matrix-R 0.19 0.08 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.00 -0.00 (loc) 5 5 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 7 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 1-9-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)5=149/0-3-8, 3=30/Mechanical, 4=12/Mechanical Max Horz 5=93(LC 6) Max Uplift 3=-36(LC 6), 4=-13(LC 6) Max Grav 5=149(LC 1), 3=30(LC 1), 4=29(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(6-7) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 4. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Copper_Run Truss J05A Truss Type JACK-OPEN Qty 3 Ply 1 4 Copper Run Job Reference (optional) I38309393 8.240 s Jul 14 2019 MiTek Industries, Inc. Mon Aug 26 12:35:33 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:30gw6Zi9UeCey_72UT9oFIyJDSk-JvDDNbRCmWFgkTdfmAsXHF4egwenUIR5Hln8tIyjzqO Scale: 3/4"=1' 1 4 2 32x4 2x4 1-9-0 1-9-0 1-9-0 1-9-0 1-1-32-6-112-0-142-6-1110.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB Matrix-R 0.13 0.06 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.00 -0.00 (loc) 4 4 2 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 6 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 1-9-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)4=64/0-3-8, 2=45/Mechanical, 3=18/Mechanical Max Horz 4=55(LC 6) Max Uplift 2=-41(LC 6), 3=-8(LC 6) Max Grav 4=64(LC 1), 2=45(LC 1), 3=31(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(6-7) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 3. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Copper_Run Truss J06 Truss Type JACK-OPEN Qty 2 Ply 1 4 Copper Run Job Reference (optional) I38309394 8.240 s Jul 14 2019 MiTek Industries, Inc. Mon Aug 26 12:35:34 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:30gw6Zi9UeCey_72UT9oFIyJDSk-n5nbaxSqWqNXLdCsKuNmqSdn4KzwDlhEVPWhQkyjzqN Scale = 1:15.6 1 2 5 3 4 2x4 3x4 2-4-15 2-4-15 -1-3-9 1-3-9 2-4-15 2-4-15 1-1-32-6-40-4-152-1-52-6-47.07 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB Matrix-R 0.21 0.07 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.00 -0.00 (loc) 4-5 4-5 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 8 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 2-4-15 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)5=203/0-7-0, 3=43/Mechanical, 4=17/Mechanical Max Horz 5=90(LC 6) Max Uplift 5=-30(LC 6), 3=-30(LC 6), 4=-1(LC 6) Max Grav 5=203(LC 1), 3=43(LC 1), 4=40(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(6-7) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 3, 4. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Copper_Run Truss J07 Truss Type HALF HIP GIRDER Qty 1 Ply 1 4 Copper Run Job Reference (optional) I38309395 8.240 s Jul 14 2019 MiTek Industries, Inc. Mon Aug 26 12:35:34 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:30gw6Zi9UeCey_72UT9oFIyJDSk-n5nbaxSqWqNXLdCsKuNmqSdouKzEDlWEVPWhQkyjzqN Scale = 1:16.3 1 2 3 4 7 6 5 4x6 2x4 2x4 2x4 3x4 2x4 0-1-21-10-12 1-10-12 3-10-8 1-11-12 -0-11-0 0-11-0 1-10-12 1-10-12 3-10-8 1-11-12 1-1-32-7-02-8-22-3-80-3-82-7-010.00 12 Plate Offsets (X,Y)-- [3:0-3-0,0-2-1] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB Matrix-MR 0.16 0.11 0.01 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.01 -0.01 0.00 (loc) 6 6 5 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 15 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 3-6: 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-10-8 oc purlins, except end verticals, and 2-0-0 oc purlins: 3-4. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)7=215/0-3-8, 5=132/0-1-8 Max Horz 7=79(LC 4) Max Uplift 7=-57(LC 5), 5=-56(LC 4) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(12-13) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 6) Bearing at joint(s) 5 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 5. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 7, 5. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 80 lb down and 55 lb up at 1-10-12 on top chord, and 6 lb down and 21 lb up at 1-10-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 11) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 12) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 13) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 2-3=-60, 3-4=-60, 5-7=-20 Concentrated Loads (lb) Vert: 6=3(B) August 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Copper_Run Truss J08 Truss Type HALF HIP GIRDER Qty 1 Ply 1 4 Copper Run Job Reference (optional) I38309396 8.240 s Jul 14 2019 MiTek Industries, Inc. Mon Aug 26 12:35:35 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:30gw6Zi9UeCey_72UT9oFIyJDSk-FHLzoHTTH7VOznn2ubv?NgAzdkJTyCmNk3GFyAyjzqM Scale = 1:16.3 1 2 3 4 7 6 5 4x6 2x4 2x4 2x4 3x4 2x4 0-1-21-10-12 1-10-12 3-10-8 1-11-12 -0-11-0 0-11-0 1-10-12 1-10-12 3-10-8 1-11-12 1-1-32-7-02-8-22-3-80-3-82-7-010.00 12 Plate Offsets (X,Y)-- [3:0-3-0,0-2-1] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB Matrix-MR 0.16 0.11 0.01 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.01 -0.01 0.00 (loc) 6 6 5 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 15 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 3-6: 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-10-8 oc purlins, except end verticals, and 2-0-0 oc purlins: 3-4. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)7=215/0-3-8, 5=132/0-1-8 Max Horz 7=79(LC 4) Max Uplift 7=-57(LC 5), 5=-56(LC 4) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(12-13) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 6) Bearing at joint(s) 5 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 5. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 7, 5. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 80 lb down and 55 lb up at 1-10-12 on top chord, and 6 lb down and 21 lb up at 1-10-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 11) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 12) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 13) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 2-3=-60, 3-4=-60, 5-7=-20 Concentrated Loads (lb) Vert: 6=3(F) August 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Copper_Run Truss J09 Truss Type JACK-OPEN Qty 1 Ply 1 4 Copper Run Job Reference (optional) I38309397 8.240 s Jul 14 2019 MiTek Industries, Inc. Mon Aug 26 12:35:35 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:30gw6Zi9UeCey_72UT9oFIyJDSk-FHLzoHTTH7VOznn2ubv?NgAy5kJvyCxNk3GFyAyjzqM Scale = 1:16.5 1 2 5 3 42x4 3x4 1-10-12 1-10-12 -0-11-0 0-11-0 1-10-12 1-10-12 1-1-32-8-22-2-52-8-210.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB Matrix-R 0.19 0.09 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.00 -0.01 (loc) 5 4-5 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 7 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 1-10-12 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)5=153/0-3-8, 3=36/Mechanical, 4=14/Mechanical Max Horz 5=97(LC 6) Max Uplift 3=-39(LC 6), 4=-12(LC 6) Max Grav 5=153(LC 1), 3=36(LC 1), 4=32(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(6-7) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 4. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Copper_Run Truss J10 Truss Type JACK-OPEN Qty 1 Ply 1 4 Copper Run Job Reference (optional) I38309398 8.240 s Jul 14 2019 MiTek Industries, Inc. Mon Aug 26 12:35:36 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:30gw6Zi9UeCey_72UT9oFIyJDSk-jUvM?dU52RdFbxMESJQEvti7r8f8hfAXzj?oUdyjzqL Scale = 1:16.5 1 2 5 3 42x4 3x4 1-10-12 1-10-12 -0-11-0 0-11-0 1-10-12 1-10-12 1-1-32-8-22-2-52-8-210.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB Matrix-R 0.19 0.09 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.00 -0.01 (loc) 5 4-5 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 7 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 1-10-12 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)5=153/0-3-8, 3=36/Mechanical, 4=14/Mechanical Max Horz 5=97(LC 6) Max Uplift 3=-39(LC 6), 4=-12(LC 6) Max Grav 5=153(LC 1), 3=36(LC 1), 4=32(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(6-7) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 4. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Copper_Run Truss J11 Truss Type JACK-OPEN Qty 1 Ply 1 4 Copper Run Job Reference (optional) I38309399 8.240 s Jul 14 2019 MiTek Industries, Inc. Mon Aug 26 12:35:36 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:30gw6Zi9UeCey_72UT9oFIyJDSk-jUvM?dU52RdFbxMESJQEvti7X8fGhfAXzj?oUdyjzqL Scale = 1:16.4 1 2 5 3 4 2x4 3x4 2-8-3 2-8-3 -1-3-9 1-3-9 2-8-3 2-8-3 1-1-32-8-27.07 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB Matrix-R 0.21 0.08 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.00 -0.01 (loc) 4-5 4-5 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 9 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 2-8-3 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)5=211/0-4-9, 3=53/Mechanical, 4=21/Mechanical Max Horz 5=95(LC 6) Max Uplift 5=-29(LC 6), 3=-34(LC 6) Max Grav 5=211(LC 1), 3=53(LC 1), 4=45(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(6-7) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 3. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Copper_Run Truss J12 Truss Type JACK-OPEN Qty 1 Ply 1 4 Copper Run Job Reference (optional) I38309400 8.240 s Jul 14 2019 MiTek Industries, Inc. Mon Aug 26 12:35:37 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:30gw6Zi9UeCey_72UT9oFIyJDSk-BgTkDyUjpll6C5xR?0xTS5FIHX?VQ6QgBNlL03yjzqK Scale = 1:16.4 1 2 5 3 4 2x4 3x4 2-8-3 2-8-3 -1-3-9 1-3-9 2-8-3 2-8-3 1-1-32-8-27.07 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB Matrix-R 0.21 0.08 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.00 -0.01 (loc) 4-5 4-5 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 9 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 2-8-3 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)5=211/0-4-9, 3=53/Mechanical, 4=21/Mechanical Max Horz 5=95(LC 6) Max Uplift 5=-29(LC 6), 3=-34(LC 6) Max Grav 5=211(LC 1), 3=53(LC 1), 4=45(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(6-7) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 3. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Copper_Run Truss J13 Truss Type JACK-OPEN Qty 1 Ply 1 4 Copper Run Job Reference (optional) I38309401 8.240 s Jul 14 2019 MiTek Industries, Inc. Mon Aug 26 12:35:37 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:30gw6Zi9UeCey_72UT9oFIyJDSk-BgTkDyUjpll6C5xR?0xTS5FIxX?7Q61gBNlL03yjzqK Scale = 1:20.4 1 2 3 5 4 2x4 3x4 2x4 2x4 2-10-0 2-10-0 -0-11-0 0-11-0 2-10-0 2-10-0 1-1-33-5-80-3-810.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB Matrix-SH 0.24 0.10 0.03 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.01 0.00 (loc) 4-5 4-5 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 12 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 2-10-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)5=179/0-5-8, 4=88/0-1-8 Max Horz 5=117(LC 6) Max Uplift 4=-61(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 5) Bearing at joint(s) 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 4. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Copper_Run Truss J14 Truss Type HALF HIP GIRDER Qty 2 Ply 1 4 Copper Run Job Reference (optional) I38309402 8.240 s Jul 14 2019 MiTek Industries, Inc. Mon Aug 26 12:35:38 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:30gw6Zi9UeCey_72UT9oFIyJDSk-gs06QIVLa2tyqEWdZjSi_IoUyxM59ZTqQ1UvZVyjzqJ Scale = 1:16.9 1 2 3 4 7 6 5 4x6 2x4 2x4 2x4 3x4 2x4 2-0-0 2-0-0 2-10-0 0-10-0 -0-11-0 0-11-0 2-0-0 2-0-0 2-10-0 0-10-0 1-1-32-9-32-5-110-3-82-9-310.00 12 Plate Offsets (X,Y)-- [3:0-4-4,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB Matrix-MR 0.16 0.05 0.01 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.00 0.00 (loc) 6 6-7 5 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 13 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 3-6: 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-10-0 oc purlins, except end verticals, and 2-0-0 oc purlins: 3-4. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)7=179/0-5-8, 5=90/0-1-8 Max Horz 7=85(LC 10) Max Uplift 7=-30(LC 5), 5=-55(LC 4) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(11-12) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) Provide adequate drainage to prevent water ponding. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 5) Bearing at joint(s) 5 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 5. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 7, 5. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 38 lb down and 38 lb up at 2-0-0 on top chord, and 6 lb down at 2-0-0 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 10) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 2-3=-60, 3-4=-60, 5-7=-20 Concentrated Loads (lb) Vert: 6=-2(B) August 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Copper_Run Truss J15 Truss Type JACK-OPEN Qty 1 Ply 1 4 Copper Run Job Reference (optional) I38309403 8.240 s Jul 14 2019 MiTek Industries, Inc. Mon Aug 26 12:35:38 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:30gw6Zi9UeCey_72UT9oFIyJDSk-gs06QIVLa2tyqEWdZjSi_IoT1xLg9ZgqQ1UvZVyjzqJ Scale = 1:16.9 1 2 5 3 4 2x4 3x4 2-9-15 2-9-15 -1-3-9 1-3-9 2-9-15 2-9-15 1-1-32-9-30-4-152-4-42-9-37.07 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB Matrix-R 0.21 0.08 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.01 -0.01 (loc) 4-5 4-5 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 10 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 2-9-15 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)5=215/0-7-6, 3=58/Mechanical, 4=23/Mechanical Max Horz 5=98(LC 6) Max Uplift 5=-28(LC 6), 3=-36(LC 6) Max Grav 5=215(LC 1), 3=58(LC 1), 4=48(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(6-7) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 3. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Copper_Run Truss J16 Truss Type JACK-OPEN Qty 1 Ply 1 4 Copper Run Job Reference (optional) I38309404 8.240 s Jul 14 2019 MiTek Industries, Inc. Mon Aug 26 12:35:39 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:30gw6Zi9UeCey_72UT9oFIyJDSk-83aUdeWzLM0pSO5p7RzxXWKdnLgvu0wzfhES5yyjzqI Scale = 1:16.9 1 2 5 3 4 2x4 3x4 2-9-15 2-9-15 -1-3-9 1-3-9 2-9-15 2-9-15 1-1-32-9-30-4-152-4-42-9-37.07 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB Matrix-R 0.21 0.08 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.01 -0.01 (loc) 4-5 4-5 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 10 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 2-9-15 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)5=215/0-7-6, 3=58/Mechanical, 4=23/Mechanical Max Horz 5=98(LC 6) Max Uplift 5=-28(LC 6), 3=-36(LC 6) Max Grav 5=215(LC 1), 3=58(LC 1), 4=48(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(6-7) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 3. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Copper_Run Truss M01 Truss Type MONOPITCH Qty 5 Ply 1 4 Copper Run Job Reference (optional) I38309405 8.240 s Jul 14 2019 MiTek Industries, Inc. Mon Aug 26 12:35:39 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:30gw6Zi9UeCey_72UT9oFIyJDSk-83aUdeWzLM0pSO5p7RzxXWKaiLdSu0wzfhES5yyjzqI Scale = 1:13.3 1 2 3 4 2x4 3x6 2x4 5-11-8 5-11-8 -0-11-0 0-11-0 5-11-8 5-11-8 0-6-32-0-11-8-90-3-82-0-13.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-AS 0.41 0.30 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.10 -0.14 0.02 (loc) 4-7 4-7 2 l/defl >706 >504 n/a L/d 240 180 n/a PLATES MT20 Weight: 16 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals. BOT CHORD Rigid ceiling directly applied. REACTIONS.(lb/size)2=292/0-5-8, 4=228/0-1-8 Max Horz 2=55(LC 4) Max Uplift 2=-92(LC 4), 4=-74(LC 4) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8-9) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed; porch left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 4) Bearing at joint(s) 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 4. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 4. 7) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Copper_Run Truss T01 Truss Type COMMON Qty 1 Ply 1 4 Copper Run Job Reference (optional) I38309406 8.240 s Jul 14 2019 MiTek Industries, Inc. Mon Aug 26 12:35:40 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:30gw6Zi9UeCey_72UT9oFIyJDSk-cF8sr_Xb6g8g3Yg?h8UA4jtoDltFdQX6uLz0dOyjzqH Scale = 1:37.5 1 2 3 4 5 6 7 8 9 11 10 6x8 4x6 3x6 4x6 2x4 3x8 2x4 6x8 4x6 9-9-8 9-9-8 19-7-0 9-9-8 -0-11-0 0-11-0 5-0-11 5-0-11 9-9-8 4-8-14 14-6-6 4-8-13 19-7-0 5-0-10 20-6-0 0-11-0 0-9-35-7-150-9-36.00 12 Plate Offsets (X,Y)-- [2:0-2-12,0-0-6], [8:0-4-8,0-0-6] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB Matrix-AS 0.23 0.65 0.23 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.11 -0.28 0.03 (loc) 10-14 10-14 8 l/defl >999 >841 n/a L/d 240 180 n/a PLATES MT20 Weight: 68 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 SLIDER Left 2x6 SPF No.2 1-6-0, Right 2x6 SPF No.2 1-6-0 BRACING- TOP CHORD Structural wood sheathing directly applied. BOT CHORD Rigid ceiling directly applied. REACTIONS.(lb/size)2=838/0-5-8, 8=838/0-5-8 Max Horz 2=-58(LC 7) Max Uplift 2=-67(LC 6), 8=-67(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-1153/198, 4-5=-906/156, 5-6=-906/156, 6-8=-1153/198 BOT CHORD 2-10=-88/984, 8-10=-88/984 WEBS 5-10=-13/510, 6-10=-297/127, 4-10=-297/127 NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 8. 6) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Copper_Run Truss T02 Truss Type MONOPITCH Qty 9 Ply 1 4 Copper Run Job Reference (optional) I38309407 8.240 s Jul 14 2019 MiTek Industries, Inc. Mon Aug 26 12:35:40 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:30gw6Zi9UeCey_72UT9oFIyJDSk-cF8sr_Xb6g8g3Yg?h8UA4jtl4l?YdTA6uLz0dOyjzqH Scale = 1:15.8 1 2 3 5 4 3x4 3x6 3x6 5-11-8 5-11-8 -0-11-0 0-11-0 5-11-8 5-11-8 0-7-82-4-62-0-140-3-82-4-63.50 12 Plate Offsets (X,Y)-- [4:Edge,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-R 0.44 0.18 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.03 -0.09 0.00 (loc) 4-5 4-5 4 l/defl >999 >718 n/a L/d 240 180 n/a PLATES MT20 Weight: 17 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 2-5: 2x6 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-11-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)5=299/0-3-8, 4=216/0-1-8 Max Horz 5=71(LC 6) Max Uplift 5=-47(LC 4), 4=-27(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-5=-257/141 NOTES-(7-8) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 4) Bearing at joint(s) 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 4. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 4. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Copper_Run Truss T03 Truss Type COMMON Qty 2 Ply 1 4 Copper Run Job Reference (optional) I38309408 8.240 s Jul 14 2019 MiTek Industries, Inc. Mon Aug 26 12:35:41 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:30gw6Zi9UeCey_72UT9oFIyJDSk-4RiF2KXDtzGXhiFCEs?PcxQyM9LwMwZG6?jZ9qyjzqG Scale = 1:30.1 1 2 3 6 5 4 2x4 2x4 3x8 4x6 3x6 3x6 4-0-12 4-0-12 8-1-8 4-0-12 4-0-12 4-0-12 8-1-8 4-0-12 1-1-34-5-131-1-310.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB Matrix-AS 0.27 0.17 0.06 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.01 -0.02 0.00 (loc) 5-6 5-6 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 32 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 1-6,3-4: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals. BOT CHORD Rigid ceiling directly applied. REACTIONS.(lb/size)6=313/0-5-8, 4=313/0-5-8 Max Horz 6=106(LC 5) Max Uplift 6=-9(LC 7), 4=-9(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-264/43, 2-3=-264/43, 1-6=-283/51, 3-4=-283/51 NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 6, 4. 6) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Copper_Run Truss T04 Truss Type HIP Qty 1 Ply 1 4 Copper Run Job Reference (optional) I38309409 8.240 s Jul 14 2019 MiTek Industries, Inc. Mon Aug 26 12:35:41 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:30gw6Zi9UeCey_72UT9oFIyJDSk-4RiF2KXDtzGXhiFCEs?PcxQtw9GyMugG6?jZ9qyjzqG Scale = 1:38.0 1 2 3 4 5 6 11 10 9 8 7 4x8 5x8 2x4 3x6 3x4 3x8 5x6 3x4 5x6 0-1-155-10-8 5-10-8 14-0-8 8-2-0 19-11-0 5-10-8 -0-11-0 0-11-0 5-10-8 5-10-8 14-0-8 8-2-0 19-11-0 5-10-8 20-10-0 0-11-0 1-1-35-10-05-11-151-1-35-10-010.00 12 Plate Offsets (X,Y)-- [2:0-3-0,0-1-12], [3:0-4-0,0-1-4], [4:0-5-4,0-2-4], [5:0-3-0,0-1-12] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB Matrix-AS 0.62 0.49 0.18 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.10 -0.25 0.01 (loc) 8-10 8-10 7 l/defl >999 >928 n/a L/d 240 180 n/a PLATES MT20 Weight: 79 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-11,5-7: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals, and 2-0-0 oc purlins (5-11-9 max.): 3-4. BOT CHORD Rigid ceiling directly applied. WEBS 1 Row at midpt 3-8 REACTIONS.(lb/size)11=849/0-3-8, 7=849/0-3-8 Max Horz 11=142(LC 5) Max Uplift 11=-47(LC 6), 7=-47(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-901/105, 3-4=-622/133, 4-5=-902/105, 2-11=-803/120, 5-7=-802/121 BOT CHORD 8-10=-84/620 WEBS 2-10=-104/513, 5-8=-111/511 NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 11, 7. 7) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Copper_Run Truss T05 Truss Type HIP Qty 1 Ply 1 4 Copper Run Job Reference (optional) I38309410 8.240 s Jul 14 2019 MiTek Industries, Inc. Mon Aug 26 12:35:42 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:30gw6Zi9UeCey_72UT9oFIyJDSk-YeGdGgYseHOOJspOoZXe98y4cYdN5LsPLfS6iGyjzqF Scale = 1:45.9 1 2 3 4 5 6 11 10 9 8 7 4x8 5x6 3x4 3x6 3x4 3x8 5x12 3x4 5x12 0-1-157-10-8 7-10-8 12-0-8 4-2-0 19-11-0 7-10-8 -0-11-0 0-11-0 7-10-8 7-10-8 12-0-8 4-2-0 19-11-0 7-10-8 20-10-0 0-11-0 1-1-37-6-07-7-151-1-37-6-010.00 12 Plate Offsets (X,Y)-- [2:0-5-1,0-2-8], [3:0-4-0,0-1-4], [4:0-3-0,0-2-1], [5:0-5-1,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB Matrix-AS 0.50 0.42 0.18 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.08 -0.20 0.02 (loc) 7-8 7-8 7 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 87 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-11,5-7: 2x6 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 3-4. BOT CHORD Rigid ceiling directly applied. WEBS 1 Row at midpt 3-8 REACTIONS.(lb/size)11=847/0-3-8, 7=847/0-3-8 Max Horz 11=182(LC 5) Max Uplift 11=-57(LC 6), 7=-57(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-840/113, 3-4=-522/148, 4-5=-840/113, 2-11=-770/139, 5-7=-769/140 BOT CHORD 10-11=-223/404, 8-10=-43/521, 7-8=-129/405 WEBS 2-10=-122/266, 5-8=-130/270 NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 11, 7. 7) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Copper_Run Truss T06 Truss Type HIP Qty 1 Ply 1 4 Copper Run Job Reference (optional) I38309411 8.240 s Jul 14 2019 MiTek Industries, Inc. Mon Aug 26 12:35:43 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:30gw6Zi9UeCey_72UT9oFIyJDSk-0qq?T0ZUPbWFw0OaMH2thMV8Vyuiqj6ZaJCgEjyjzqE Scale = 1:55.4 1 2 3 4 5 6 7 11 10 9 8 4x6 3x6 3x8 3x4 3x4 3x4 4x8 4x8 3x4 9-11-8 9-11-8 19-11-0 9-11-8 -0-11-0 0-11-0 4-2-3 4-2-3 9-11-8 5-9-4 15-8-13 5-9-5 19-11-0 4-2-4 20-10-0 0-11-0 1-1-39-3-151-1-310.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB Matrix-AS 0.94 0.73 0.50 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.16 -0.41 0.02 (loc) 8-9 8-9 8 l/defl >999 >569 n/a L/d 240 180 n/a PLATES MT20 Weight: 84 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-11,6-8: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals. BOT CHORD Rigid ceiling directly applied. REACTIONS.(lb/size)11=849/0-3-8, 8=849/0-3-8 Max Horz 11=-222(LC 4) Max Uplift 11=-59(LC 6), 8=-59(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-351/35, 3-4=-707/133, 4-5=-707/133, 5-6=-351/35, 2-11=-310/71, 6-8=-310/71 BOT CHORD 9-11=-75/594, 8-9=0/594 WEBS 4-9=-40/484, 3-11=-617/91, 5-8=-617/91 NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 11, 8. 6) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Copper_Run Truss T07 Truss Type COMMON Qty 2 Ply 1 4 Copper Run Job Reference (optional) I38309412 8.240 s Jul 14 2019 MiTek Industries, Inc. Mon Aug 26 12:35:43 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:30gw6Zi9UeCey_72UT9oFIyJDSk-0qq?T0ZUPbWFw0OaMH2thMV8Vyuiqj6ZaJCgEjyjzqE Scale = 1:55.5 1 2 3 4 5 6 7 11 10 9 8 4x6 3x6 3x8 3x4 3x4 3x4 4x8 4x8 3x4 9-11-8 9-11-8 19-11-0 9-11-8 -0-11-0 0-11-0 4-2-4 4-2-4 9-11-8 5-9-4 15-8-12 5-9-4 19-11-0 4-2-4 20-10-0 0-11-0 1-1-39-4-121-1-310.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB Matrix-AS 0.94 0.73 0.50 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.16 -0.41 0.02 (loc) 8-9 8-9 8 l/defl >999 >569 n/a L/d 240 180 n/a PLATES MT20 Weight: 84 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-11,6-8: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals. BOT CHORD Rigid ceiling directly applied. REACTIONS.(lb/size)11=849/0-3-8, 8=849/0-3-8 Max Horz 11=-223(LC 4) Max Uplift 11=-58(LC 6), 8=-58(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-351/35, 3-4=-707/133, 4-5=-707/133, 5-6=-351/35, 2-11=-310/71, 6-8=-310/71 BOT CHORD 9-11=-75/594, 8-9=0/594 WEBS 4-9=-41/486, 3-11=-616/92, 5-8=-616/92 NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 11, 8. 6) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Copper_Run Truss T08 Truss Type COMMON Qty 3 Ply 1 4 Copper Run Job Reference (optional) I38309413 8.240 s Jul 14 2019 MiTek Industries, Inc. Mon Aug 26 12:35:44 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:30gw6Zi9UeCey_72UT9oFIyJDSk-U0ONhMa6Aue6Y9znw_Z6EZ2JFMExZAKipzxDm9yjzqD Scale = 1:55.5 1 2 3 4 5 6 10 9 8 7 4x6 3x4 3x6 3x8 3x4 3x4 3x4 4x8 4x8 9-11-8 9-11-8 19-11-0 9-11-8 -0-11-0 0-11-0 4-2-4 4-2-4 9-11-8 5-9-4 15-8-12 5-9-4 19-11-0 4-2-4 1-1-39-4-121-1-310.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB Matrix-AS 0.94 0.73 0.50 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.16 -0.41 0.02 (loc) 8-10 8-10 7 l/defl >999 >569 n/a L/d 240 180 n/a PLATES MT20 Weight: 83 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-10,6-7: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals. BOT CHORD Rigid ceiling directly applied. REACTIONS.(lb/size)10=850/0-3-8, 7=783/0-3-8 Max Horz 10=234(LC 5) Max Uplift 10=-58(LC 6), 7=-25(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-351/35, 3-4=-709/133, 4-5=-710/133, 5-6=-351/19, 2-10=-310/71 BOT CHORD 8-10=-86/596, 7-8=-16/602 WEBS 4-8=-41/487, 3-10=-619/91, 5-7=-613/108 NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 10, 7. 6) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Copper_Run Truss T09 Truss Type COMMON Qty 1 Ply 1 4 Copper Run Job Reference (optional) I38309414 8.240 s Jul 14 2019 MiTek Industries, Inc. Mon Aug 26 12:35:44 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:30gw6Zi9UeCey_72UT9oFIyJDSk-U0ONhMa6Aue6Y9znw_Z6EZ2JxMELZASipzxDm9yjzqD Scale = 1:55.5 1 2 3 4 5 6 10 9 8 7 4x6 2x4 3x6 3x4 3x8 3x4 4x8 3x4 4x8 9-11-8 9-11-8 19-6-0 9-6-8 -0-11-0 0-11-0 4-2-4 4-2-4 9-11-8 5-9-4 15-8-12 5-9-4 19-6-0 3-9-4 1-1-39-4-121-5-610.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB Matrix-AS 0.96 0.70 0.49 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.17 -0.43 0.02 (loc) 8-10 8-10 7 l/defl >999 >538 n/a L/d 240 180 n/a PLATES MT20 Weight: 82 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 6-7,2-10: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals. BOT CHORD Rigid ceiling directly applied. REACTIONS.(lb/size)7=767/Mechanical, 10=834/0-3-8 Max Horz 10=238(LC 5) Max Uplift 7=-23(LC 7), 10=-58(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-355/33, 3-4=-685/132, 4-5=-685/132, 2-10=-310/70 BOT CHORD 8-10=-93/580, 7-8=-10/541 WEBS 4-8=-39/462, 5-7=-674/96, 3-10=-595/92 NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 7, 10. 7) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Copper_Run Truss T11 Truss Type HIP Qty 1 Ply 1 4 Copper Run Job Reference (optional) I38309415 8.240 s Jul 14 2019 MiTek Industries, Inc. Mon Aug 26 12:35:45 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:30gw6Zi9UeCey_72UT9oFIyJDSk-yDxluibkxCmzAJYzTi4LnnaVdmZzIZjs1dhmIbyjzqC Scale = 1:66.6 1 2 3 4 5 6 7 8 9 10 11 20 19 18 17 16 15 14 13 12 5x8 3x6 3x4 2x4 4x6 6x10 2x4 3x8 3x6 3x4 3x4 5x12 5x8 2x4 8x10 4x6 4x8 4x10 0-1-152-3-8 2-3-8 7-7-2 5-3-10 13-4-8 5-9-6 20-10-14 7-6-6 28-3-14 7-5-0 35-11-0 7-7-2 -0-11-0 0-11-0 2-3-8 2-3-8 7-7-2 5-3-10 13-4-8 5-9-6 20-10-14 7-6-6 28-3-14 7-5-0 35-11-0 7-7-2 36-10-0 0-11-0 0-11-35-10-05-11-150-11-30-8-05-10-08.00 12 Plate Offsets (X,Y)-- [2:0-2-14,0-2-0], [4:0-4-0,0-1-9], [8:0-4-0,0-1-9] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB Matrix-AS 0.90 0.74 0.68 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.17 -0.43 0.20 (loc) 12-14 14-15 10 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 143 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 6-8: 2x4 SPF 2100F 1.8E BOT CHORD 2x4 SPF No.2 *Except* 3-19,5-15: 2x3 SPF No.2, 10-13: 2x4 SPF 2100F 1.8E WEBS 2x3 SPF No.2 *Except* 2-20: 2x4 SPF-S Stud SLIDER Right 2x6 SPF No.2 2-6-0 BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals, and 2-0-0 oc purlins (3-3-0 max.): 4-8. BOT CHORD Rigid ceiling directly applied. REACTIONS.(lb/size)20=1495/0-3-8, 10=1486/0-3-8 Max Horz 20=131(LC 5) Max Uplift 20=-78(LC 5), 10=-77(LC 4) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2307/205, 3-4=-2177/218, 4-5=-2482/296, 5-7=-2469/296, 7-8=-2312/285, 8-10=-1966/209, 2-20=-1453/157 BOT CHORD 17-18=-262/1954, 16-17=-206/1748, 5-16=-429/175, 14-15=-9/335, 12-14=-66/1550, 10-12=-64/1552 WEBS 4-17=0/319, 4-16=-216/1013, 14-16=-231/1993, 7-14=-636/247, 8-14=-225/1035, 8-12=0/256, 2-18=-172/1779 NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 20, 10. 7) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Copper_Run Truss T12 Truss Type HIP Qty 1 Ply 1 4 Copper Run Job Reference (optional) I38309416 8.240 s Jul 14 2019 MiTek Industries, Inc. Mon Aug 26 12:35:48 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:30gw6Zi9UeCey_72UT9oFIyJDSk-NoduWjdcD78Y1nHY9qd2OPC2mzXzVuKIjbvRvwyjzq9 Scale = 1:64.9 1 2 3 4 5 6 7 8 9 10 11 20 19 18 17 16 15 14 13 12 5x8 5x8 3x4 2x4 6x10 6x10 2x4 3x8 3x6 3x4 3x4 4x10 3x4 2x4 8x10 4x6 4x8 5x12 0-1-152-3-8 2-3-8 10-1-2 7-9-10 13-4-8 3-3-6 19-7-3 6-2-11 25-9-14 6-2-11 35-11-0 10-1-2 -0-11-0 0-11-0 2-3-8 2-3-8 10-1-2 7-9-10 13-4-8 3-3-6 19-7-3 6-2-11 25-9-14 6-2-11 30-4-8 4-6-9 35-11-0 5-6-8 36-10-0 0-11-0 0-11-37-6-07-7-150-11-30-8-07-6-08.00 12 Plate Offsets (X,Y)-- [2:0-2-14,0-2-0], [4:0-4-0,0-1-9], [7:0-4-0,0-1-9] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB Matrix-AS 0.71 0.98 0.82 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.16 -0.41 0.18 (loc) 12-23 12-23 10 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 156 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 3-19,5-15: 2x3 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-20: 2x4 SPF-S Stud SLIDER Right 2x6 SPF No.2 2-6-0 BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals, and 2-0-0 oc purlins (3-10-0 max.): 4-7. BOT CHORD Rigid ceiling directly applied. WEBS 1 Row at midpt 6-16 REACTIONS.(lb/size)20=1495/0-3-8, 10=1486/0-3-8 Max Horz 20=170(LC 5) Max Uplift 20=-62(LC 6), 10=-58(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2378/214, 3-4=-2051/211, 4-5=-1825/252, 5-6=-1824/252, 6-7=-1793/260, 7-8=-1779/223, 8-10=-1941/218, 2-20=-1448/140 BOT CHORD 17-18=-251/2111, 16-17=-140/1598, 5-16=-306/143, 14-15=0/299, 12-14=-12/1453, 10-12=-74/1530 WEBS 3-17=-524/216, 4-17=0/385, 4-16=-195/601, 14-16=-145/1517, 6-14=-493/212, 7-14=-166/601, 7-12=0/331, 2-18=-131/1905 NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 20, 10. 7) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Copper_Run Truss T13 Truss Type HIP Qty 1 Ply 1 4 Copper Run Job Reference (optional) I38309417 8.240 s Jul 14 2019 MiTek Industries, Inc. Mon Aug 26 12:35:51 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:30gw6Zi9UeCey_72UT9oFIyJDSk-nMJ09lfVW2W6uE?7qyBl02qYwAZ3iHtkQY85WFyjzq6 Scale = 1:68.5 1 2 3 4 5 6 7 8 9 10 11 12 13 24 23 22 21 20 19 18 17 16 15 14 3x6 5x6 5x6 3x6 2x4 2x4 3x4 6x16 10x10 3x6 3x8 3x4 5x12 3x8 3x6 2x4 6x10 4x6 4x8 5x8 2x4 0-1-152-3-8 2-3-8 13-4-8 11-1-0 17-11-8 4-7-0 23-3-14 5-4-6 29-1-0 5-9-2 35-11-0 6-10-0 -0-11-0 0-11-0 2-3-8 2-3-8 7-6-6 5-2-14 12-7-2 5-0-12 17-11-8 5-4-6 23-3-14 5-4-6 29-1-0 5-9-2 35-11-0 6-10-0 36-10-0 0-11-0 0-11-39-2-09-3-150-11-30-8-09-2-08.00 12 Plate Offsets (X,Y)-- [2:0-2-14,0-2-0], [6:0-3-2,Edge], [8:0-3-1,Edge], [18:0-1-12,0-0-0], [19:0-2-12,0-2-8], [20:0-1-12,0-0-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB Matrix-AS 0.78 0.96 0.64 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.31 -0.86 0.19 (loc) 21-22 21-22 12 l/defl >999 >502 n/a L/d 240 180 n/a PLATES MT20 Weight: 169 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 3-23: 2x3 SPF No.2, 18-20: 2x4 SPF-S Stud WEBS 2x3 SPF No.2 *Except* 7-15: 2x4 SPF No.2, 2-24: 2x4 SPF-S Stud SLIDER Right 2x6 SPF No.2 2-6-0 BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals, and 2-0-0 oc purlins (4-8-7 max.): 6-8. BOT CHORD Rigid ceiling directly applied. WEBS 1 Row at midpt 7-15, 7-21 REACTIONS.(lb/size)24=1495/0-3-8, 12=1486/0-3-8 Max Horz 24=208(LC 5) Max Uplift 24=-74(LC 6), 12=-71(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2357/163, 3-4=-2512/221, 4-6=-1805/228, 6-7=-1429/221, 7-8=-1329/232, 8-10=-1677/237, 10-12=-1954/191, 2-24=-1476/136 BOT CHORD 21-22=-124/1690, 20-21=-43/1559, 19-20=-16/1229, 17-18=-27/330, 15-17=-27/344, 14-15=-44/1536, 12-14=-44/1536 WEBS 4-21=-357/169, 7-15=-532/149, 8-15=-28/538, 10-15=-296/141, 15-19=-16/1225, 6-21=-28/651, 4-22=-53/530, 2-22=-45/1869, 7-21=-350/162, 7-19=0/273 NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 24, 12. 7) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Copper_Run Truss T14 Truss Type HIP Qty 1 Ply 1 4 Copper Run Job Reference (optional) I38309418 8.240 s Jul 14 2019 MiTek Industries, Inc. Mon Aug 26 12:35:52 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:30gw6Zi9UeCey_72UT9oFIyJDSk-FZtPM5g7HMezWOaJOgi_ZFNm8axvRlXueCte2hyjzq5 Scale = 1:84.1 1 2 3 4 5 6 7 8 9 10 11 12 22 21 20 19 18 17 16 15 14 13 3x6 5x8 5x6 3x6 3x4 2x4 4x6 5x8 2x4 2x4 3x6 3x6 2x4 5x12 3x6 2x4 8x10 4x6 4x8 4x10 3x6 0-1-152-3-8 2-3-8 7-8-13 5-5-5 13-4-8 5-7-11 15-1-2 1-8-10 20-9-14 5-8-12 26-11-7 6-1-9 35-11-0 8-11-9 -0-11-0 0-11-0 2-3-8 2-3-8 7-8-13 5-5-5 15-1-2 7-4-5 20-9-14 5-8-12 26-11-7 6-1-9 35-11-0 8-11-9 36-10-0 0-11-0 0-11-310-10-010-11-150-11-30-8-010-10-08.00 12 Plate Offsets (X,Y)-- [2:0-2-14,0-2-0], [6:0-4-0,0-1-9], [7:0-3-1,Edge], [18:0-2-8,0-2-8], [19:0-2-8,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB Matrix-AS 0.62 0.79 0.62 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.13 -0.40 0.15 (loc) 18-19 18-19 11 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 172 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 3-21,17-23: 2x3 SPF No.2 WEBS 2x3 SPF No.2 *Except* 6-16,6-15,7-15: 2x4 SPF No.2, 2-22: 2x4 SPF-S Stud SLIDER Right 2x6 SPF No.2 3-0-0 BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals, and 2-0-0 oc purlins (5-0-15 max.): 6-7. BOT CHORD Rigid ceiling directly applied. WEBS 1 Row at midpt 4-18, 6-15, 8-15 REACTIONS.(lb/size)22=1514/0-3-8, 11=1498/0-3-8 Max Horz 22=247(LC 5) Max Uplift 22=-73(LC 6), 11=-74(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2330/148, 3-4=-2190/167, 4-6=-1685/214, 6-7=-1211/228, 7-8=-1559/235, 8-11=-1932/178, 2-22=-1476/129 BOT CHORD 19-20=-160/1961, 18-19=-48/1760, 13-15=-7/1516, 11-13=-7/1516 WEBS 4-18=-568/154, 6-18=0/647, 6-15=-293/128, 7-15=-30/493, 8-15=-464/174, 8-13=0/282, 2-20=-91/1790, 15-18=0/1244, 4-19=0/357 NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 22, 11. 7) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Copper_Run Truss T15 Truss Type HIP Qty 1 Ply 1 4 Copper Run Job Reference (optional) I38309419 8.240 s Jul 14 2019 MiTek Industries, Inc. Mon Aug 26 12:35:54 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:30gw6Zi9UeCey_72UT9oFIyJDSk-Cx_9nniNpzuhlikiV5kSegS1dOd8vaGA6WMl7ayjzq3 Scale = 1:85.5 1 2 3 4 5 6 7 8 9 10 11 12 13 26 25 24 23 22 21 19 18 20 17 16 15 14 3x6 3x6 3x4 2x4 4x6 8x10 2x4 2x4 3x4 8x8 2x4 8x8 3x4 2x4 6x10 4x6 3x6 3x6 6x10 6x6 4x6 4x8 4x10 4x8 2-3-8 2-3-8 7-10-0 5-6-8 13-4-8 5-6-8 17-11-8 4-7-0 18-3-14 0-4-6 22-10-0 4-6-2 25-9-0 2-11-0 29-0-15 3-3-15 35-11-0 6-10-1 -0-11-0 0-11-0 2-3-8 2-3-8 7-10-0 5-6-8 13-4-8 5-6-8 17-7-2 4-2-10 17-11-8 0-4-6 18-3-14 0-4-6 25-9-0 7-5-2 29-0-15 3-3-15 35-11-0 6-10-1 36-10-0 0-11-0 0-11-312-7-150-11-33-0-00-8-00-8-08.00 12 Plate Offsets (X,Y)-- [2:0-2-14,0-2-0], [14:0-2-8,0-3-0], [16:0-2-8,0-4-4], [17:0-3-8,0-4-0], [23:0-2-8,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB Matrix-AS 0.94 0.80 0.92 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.32 -0.85 0.53 (loc) 17 17-20 12 l/defl >999 >507 n/a L/d 240 180 n/a PLATES MT20 Weight: 207 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 3-25,6-21,9-15: 2x3 SPF No.2, 16-20: 2x6 SP 2400F 2.0E WEBS 2x3 SPF No.2 *Except* 7-22,7-16,7-19: 2x4 SPF No.2, 2-26: 2x4 SPF-S Stud SLIDER Right 2x6 SPF No.2 3-0-0 BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals. BOT CHORD Rigid ceiling directly applied. Except: 1 Row at midpt 6-22 WEBS 1 Row at midpt 7-20 JOINTS 1 Brace at Jt(s): 20 REACTIONS.(lb/size)26=1495/0-3-8, 12=1486/0-3-8 Max Horz 26=291(LC 5) Max Uplift 26=-94(LC 6), 12=-90(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2308/159, 3-4=-2143/176, 4-6=-1722/218, 6-7=-1658/316, 7-9=-3143/349, 9-10=-3004/200, 10-12=-1935/168, 2-26=-1456/131 BOT CHORD 23-24=-221/1958, 22-23=-93/1714, 6-22=-270/150, 16-17=0/1054, 9-16=-377/193, 12-14=-22/1523 WEBS 3-23=-271/134, 4-23=0/312, 4-22=-495/132, 19-22=0/981, 7-22=-186/838, 14-16=-14/2137, 10-16=0/1151, 10-14=-1403/63, 7-16=-145/2276, 2-24=-134/1785, 17-19=0/1092, 19-20=-629/14, 7-20=-410/39 NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 26, 12. 6) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Copper_Run Truss T16 Truss Type ROOF SPECIAL Qty 1 Ply 1 4 Copper Run Job Reference (optional) I38309420 8.240 s Jul 14 2019 MiTek Industries, Inc. Mon Aug 26 12:35:55 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:30gw6Zi9UeCey_72UT9oFIyJDSk-g8YX_6i?aH1YNsJu3oFhAu?Fhozye4jKKA6If0yjzq2 Scale = 1:82.4 1 2 3 4 5 6 7 8 9 10 11 12 21 20 19 18 17 16 15 14 13 3x6 3x8 3x4 2x4 4x6 8x10 2x4 2x4 3x6 3x6 3x6 6x8 4x8 3x6 2x4 6x10 4x6 4x8 4x10 2-3-8 2-3-8 7-10-0 5-6-8 13-4-8 5-6-8 17-11-8 4-7-0 26-11-7 8-11-15 35-11-0 8-11-9 -0-11-0 0-11-0 2-3-8 2-3-8 7-10-0 5-6-8 13-4-8 5-6-8 17-11-8 4-7-0 26-11-7 8-11-15 35-11-0 8-11-9 36-10-0 0-11-0 0-11-312-10-140-11-30-8-08.00 12 Plate Offsets (X,Y)-- [2:0-2-14,0-2-0], [11:0-6-12,0-0-4], [18:0-2-8,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB Matrix-AS 0.67 0.83 0.71 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.16 -0.48 0.17 (loc) 13-15 13-15 11 l/defl >999 >900 n/a L/d 240 180 n/a PLATES MT20 Weight: 173 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 3-20,6-16: 2x3 SPF No.2 WEBS 2x3 SPF No.2 *Except* 7-17,7-15,9-15: 2x4 SPF No.2, 2-21: 2x4 SPF-S Stud SLIDER Right 2x6 SPF No.2 3-0-0 BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals. BOT CHORD Rigid ceiling directly applied. Except: 1 Row at midpt 6-17 WEBS 1 Row at midpt 9-15 REACTIONS.(lb/size)21=1495/0-3-8, 11=1486/0-3-8 Max Horz 21=293(LC 5) Max Uplift 21=-93(LC 6), 11=-89(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2308/159, 3-4=-2143/176, 4-6=-1722/218, 6-7=-1670/321, 7-9=-1415/235, 9-11=-1933/179, 2-21=-1456/131 BOT CHORD 18-19=-223/1957, 17-18=-94/1715, 6-17=-289/156, 13-15=-13/1525, 11-13=-13/1525 WEBS 3-18=-270/135, 4-18=0/311, 4-17=-497/132, 15-17=0/986, 7-17=-199/852, 7-15=-56/456, 9-15=-624/202, 9-13=0/347, 2-19=-135/1784 NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 21, 11. 6) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Copper_Run Truss T17 Truss Type COMMON Qty 1 Ply 1 4 Copper Run Job Reference (optional) I38309421 8.240 s Jul 14 2019 MiTek Industries, Inc. Mon Aug 26 12:35:57 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:30gw6Zi9UeCey_72UT9oFIyJDSk-cWgIPokG6uHGc9THADI9GI4WCbd664odoUbPkvyjzq0 Scale = 1:76.9 1 2 3 4 5 6 7 8 9 1011 16 15 14 13 12 3x8 5x6 3x8 8x10 4x6 3x6 3x8 3x6 2x4 3x6 2x4 3x6 8x10 4x6 8-11-8 8-11-8 17-11-8 9-0-0 26-11-8 9-0-0 35-11-0 8-11-8 -0-11-0 0-11-0 8-11-8 8-11-8 17-11-8 9-0-0 26-11-8 9-0-0 35-11-0 8-11-8 36-10-0 0-11-0 0-11-312-10-140-11-38.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB Matrix-MS 0.98 0.91 0.36 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.14 -0.44 0.13 (loc) 14-16 14-16 10 l/defl >999 >986 n/a L/d 240 180 n/a PLATES MT20 Weight: 153 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* 8-12,4-16: 2x3 SPF No.2 SLIDER Left 2x6 SPF No.2 3-0-0, Right 2x6 SPF No.2 3-0-0 BRACING- TOP CHORD Structural wood sheathing directly applied. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 8-14, 4-14 REACTIONS.(lb/size)2=1492/0-3-8, 10=1492/0-3-8 Max Horz 2=-280(LC 4) Max Uplift 2=-89(LC 6), 10=-89(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-1742/181, 4-6=-1425/232, 6-8=-1425/232, 8-10=-1742/181 BOT CHORD 2-16=-91/1532, 14-16=-91/1532, 12-14=-14/1532, 10-12=-14/1532 WEBS 6-14=-90/893, 8-14=-626/207, 8-12=0/334, 4-14=-626/206, 4-16=0/334 NOTES-(6-7) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 10. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Copper_Run Truss T18 Truss Type COMMON Qty 1 Ply 1 4 Copper Run Job Reference (optional) I38309422 8.240 s Jul 14 2019 MiTek Industries, Inc. Mon Aug 26 12:35:57 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:30gw6Zi9UeCey_72UT9oFIyJDSk-cWgIPokG6uHGc9THADI9GI4WDbeT64ldoUbPkvyjzq0 Scale = 1:75.4 1 2 3 4 5 6 7 8 9 14 13 12 11 10 3x6 5x6 3x6 8x10 4x6 3x6 3x8 3x6 2x4 3x6 2x4 8x10 4x6 3x6 8-11-8 8-11-8 17-11-8 9-0-0 26-11-8 9-0-0 35-11-0 8-11-8 8-11-8 8-11-8 17-11-8 9-0-0 26-11-8 9-0-0 35-11-0 8-11-8 0-11-312-10-140-11-38.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB Matrix-MS 0.98 0.89 0.36 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.14 -0.43 0.13 (loc) 12-14 12-14 9 l/defl >999 >992 n/a L/d 240 180 n/a PLATES MT20 Weight: 150 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* 7-10,3-14: 2x3 SPF No.2 SLIDER Left 2x6 SPF No.2 3-0-0, Right 2x6 SPF No.2 3-0-0 BRACING- TOP CHORD Structural wood sheathing directly applied. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 7-12, 3-12 REACTIONS.(lb/size)1=1437/Mechanical, 9=1437/Mechanical Max Horz 1=-278(LC 4) Max Uplift 1=-61(LC 6), 9=-61(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-3=-1747/182, 3-5=-1427/233, 5-7=-1427/233, 7-9=-1747/182 BOT CHORD 1-14=-102/1537, 12-14=-102/1537, 10-12=-42/1537, 9-10=-42/1537 WEBS 5-12=-90/897, 7-12=-629/207, 7-10=0/334, 3-12=-629/207, 3-14=0/334 NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 9. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Copper_Run Truss T19 Truss Type ROOF SPECIAL Qty 1 Ply 1 4 Copper Run Job Reference (optional) I38309423 8.240 s Jul 14 2019 MiTek Industries, Inc. Mon Aug 26 12:35:58 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:30gw6Zi9UeCey_72UT9oFIyJDSk-4jEgd8lutCP7EJ2TkwpOoWdh_?zorS0m18KzGLyjzq? Scale = 1:76.8 1 2 3 4 5 6 7 8 9 16 15 14 13 12 11 10 3x6 5x6 3x6 8x10 4x6 3x6 3x6 2x4 3x8 3x6 3x4 6x8 5x6 5x8 2x4 3x6 0-1-158-11-9 8-11-9 17-11-8 8-11-15 26-11-8 8-11-15 32-10-4 5-10-12 35-11-0 3-0-12 8-11-9 8-11-9 17-11-8 8-11-15 26-11-8 8-11-15 32-10-4 5-10-12 35-8-0 2-9-12 35-11-0 0-3-0 0-11-312-10-142-6-42-9-128.00 12 Plate Offsets (X,Y)-- [8:0-2-14,Edge], [11:0-2-8,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB Matrix-MSH 0.98 0.89 0.68 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.15 -0.43 0.10 (loc) 12-14 12-14 10 l/defl >999 >998 n/a L/d 240 180 n/a PLATES MT20 Weight: 157 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 6-8: 2x4 SPF 2100F 1.8E BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 3-14,5-14,7-14,9-10: 2x4 SPF No.2 SLIDER Left 2x6 SPF No.2 3-0-0 BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals, and 2-0-0 oc purlins (4-7-11 max.): 8-9. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-14, 7-14 REACTIONS.(lb/size)1=1431/Mechanical, 10=1431/Mechanical Max Horz 1=309(LC 5) Max Uplift 1=-60(LC 6), 10=-61(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-3=-1738/182, 3-5=-1417/233, 5-7=-1420/232, 7-8=-1882/185, 8-9=-1546/133, 9-10=-1391/112 BOT CHORD 1-16=-103/1529, 14-16=-103/1529, 12-14=-31/1522, 11-12=-64/1495 WEBS 3-16=0/334, 3-14=-631/207, 5-14=-87/892, 7-14=-618/195, 7-12=0/315, 8-11=-1207/132, 9-11=-128/1977 NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 10. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Copper_Run Truss T20 Truss Type ROOF SPECIAL Qty 1 Ply 1 4 Copper Run Job Reference (optional) I38309424 8.240 s Jul 14 2019 MiTek Industries, Inc. Mon Aug 26 12:35:59 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:30gw6Zi9UeCey_72UT9oFIyJDSk-Yvo2qUlWeVX_rTdfIeKdLj9skPJ0aqBvFo4Wonyjzq_ Scale = 1:77.3 1 2 3 4 5 6 7 8 9 10 17 16 15 14 13 12 11 3x6 5x6 3x6 6x6 5x6 5x6 8x10 4x6 3x6 3x6 2x4 3x8 3x6 3x4 2x4 5x8 3x6 0-1-158-11-8 8-11-8 17-11-8 9-0-0 26-11-8 8-11-15 30-4-4 3-4-12 33-8-0 3-3-12 35-11-0 2-3-0 8-11-8 8-11-8 17-11-8 9-0-0 26-11-8 8-11-15 30-4-4 3-4-12 33-8-0 3-3-12 35-11-0 2-3-0 0-11-34-5-1212-10-142-9-34-5-128.00 12 10.00 12 Plate Offsets (X,Y)-- [8:0-2-15,Edge], [9:0-3-0,0-2-1] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB Matrix-MSH 0.98 0.89 1.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.14 -0.42 0.10 (loc) 13-15 15-17 11 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 161 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 6-8: 2x4 SPF 2100F 1.8E BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 3-15,5-15,7-15: 2x4 SPF No.2, 10-11: 2x4 SPF-S Stud SLIDER Left 2x6 SPF No.2 3-0-0 BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 8-9. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-15, 7-15 REACTIONS.(lb/size)1=1431/Mechanical, 11=1431/Mechanical Max Horz 1=310(LC 5) Max Uplift 1=-60(LC 6), 11=-61(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-3=-1738/182, 3-5=-1417/234, 5-7=-1419/232, 7-8=-1833/190, 8-9=-663/101, 9-10=-885/103, 10-11=-1424/98 BOT CHORD 1-17=-103/1530, 15-17=-103/1530, 13-15=-32/1521, 12-13=-55/1533 WEBS 3-17=0/334, 3-15=-631/207, 5-15=-88/891, 7-15=-618/193, 7-13=0/334, 8-12=-1388/105, 9-12=0/334, 10-12=-29/1074 NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 11. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Copper_Run Truss T21 Truss Type ROOF SPECIAL Qty 1 Ply 1 4 Copper Run Job Reference (optional) I38309425 8.240 s Jul 14 2019 MiTek Industries, Inc. Mon Aug 26 12:36:00 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:30gw6Zi9UeCey_72UT9oFIyJDSk-UIvoFAnmA7ni5nm2P3M5Q8FCBC?T2ncCj6Zdshyjzpy Scale = 1:77.8 1 2 3 4 5 6 7 8 9 10 11 19 18 17 16 15 14 13 12 3x6 5x6 5x8 6x6 5x6 5x6 5x6 8x10 4x6 3x6 3x6 2x4 3x8 3x6 3x4 4x8 2x4 4x8 3x6 0-1-150-1-158-11-9 8-11-9 17-11-8 8-11-15 26-11-7 8-11-15 29-8-0 2-8-9 32-8-0 3-0-0 35-11-0 3-3-0 8-11-9 8-11-9 17-11-8 8-11-15 26-11-7 8-11-15 27-10-4 0-10-13 29-8-0 1-9-12 30-8-0 1-0-0 32-8-0 2-0-0 35-11-0 3-3-0 0-11-36-1-125-3-1212-10-142-9-36-1-128.00 12 10.00 12 Plate Offsets (X,Y)-- [7:0-4-0,0-1-14], [8:0-3-11,Edge], [9:0-3-0,0-2-0], [10:0-3-0,0-2-1] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB Matrix-MSH 0.98 0.89 0.82 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.16 -0.46 0.10 (loc) 15-17 15-17 12 l/defl >999 >924 n/a L/d 240 180 n/a PLATES MT20 Weight: 176 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 5-7: 2x4 SPF 2100F 1.8E BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 3-17,5-17,6-17: 2x4 SPF No.2, 11-12: 2x4 SPF-S Stud SLIDER Left 2x6 SPF No.2 3-0-0 BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals, and 2-0-0 oc purlins (5-0-10 max.): 7-8, 9-10. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-17, 6-17 REACTIONS.(lb/size)1=1431/Mechanical, 12=1431/Mechanical Max Horz 1=310(LC 5) Max Uplift 1=-60(LC 6), 12=-61(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-3=-1738/184, 3-5=-1418/234, 5-6=-1421/234, 6-7=-1584/105, 7-8=-1256/173, 8-9=-1553/200, 9-10=-792/126, 10-11=-1082/127, 11-12=-1401/114 BOT CHORD 1-19=-103/1529, 17-19=-103/1529, 15-17=-37/1521, 14-15=-19/1490, 13-14=-23/1223 WEBS 3-19=0/332, 3-17=-629/207, 5-17=-90/895, 6-17=-619/198, 7-15=-133/266, 7-14=-846/21, 8-14=-78/728, 9-13=-1122/85, 10-13=-15/436, 11-13=-24/1034 NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 12. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Copper_Run Truss T22 Truss Type ROOF SPECIAL Qty 1 Ply 1 4 Copper Run Job Reference (optional) I38309426 8.240 s Jul 14 2019 MiTek Industries, Inc. Mon Aug 26 12:36:02 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:30gw6Zi9UeCey_72UT9oFIyJDSk-zUTBSWoOwQvZiwLEzmuKzMnNlcLenHNMxmIAO6yjzpx Scale = 1:82.5 1 2 3 4 5 6 7 8 9 10 17 16 15 14 13 12 11 3x6 5x6 5x8 5x6 6x6 5x6 8x10 4x6 3x6 3x6 2x4 3x8 4x8 6x8 2x4 5x6 3x6 0-1-150-1-158-11-9 8-11-9 17-11-8 8-11-15 27-8-0 9-8-8 34-8-0 7-0-0 35-11-0 1-3-0 8-11-9 8-11-9 17-11-8 8-11-15 25-4-4 7-4-12 27-8-0 2-3-12 32-8-0 5-0-0 34-8-0 2-0-0 35-11-0 1-3-0 0-11-37-9-123-7-1212-10-142-9-37-9-128.00 12 10.00 12 Plate Offsets (X,Y)-- [6:0-4-0,0-1-14], [7:0-3-0,0-2-1], [8:0-2-5,Edge], [9:0-3-0,0-2-1] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB Matrix-MSH 1.00 0.89 0.59 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.19 -0.54 0.10 (loc) 13-15 13-15 11 l/defl >999 >792 n/a L/d 240 180 n/a PLATES MT20 Weight: 166 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 3-15,5-15,6-15: 2x4 SPF No.2, 10-11: 2x4 SPF-S Stud SLIDER Left 2x6 SPF No.2 3-0-0 BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals, and 2-0-0 oc purlins (4-11-14 max.): 6-7, 8-9. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-15, 6-15, 6-13 REACTIONS.(lb/size)1=1431/Mechanical, 11=1431/Mechanical Max Horz 1=310(LC 5) Max Uplift 1=-60(LC 6), 11=-61(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-3=-1738/185, 3-5=-1418/234, 5-6=-1382/237, 6-7=-1204/184, 7-8=-1675/181, 8-9=-422/64, 9-10=-560/75, 10-11=-1416/81 BOT CHORD 1-17=-104/1530, 15-17=-104/1530, 13-15=-8/1406, 12-13=-59/1198 WEBS 3-17=0/329, 3-15=-629/208, 5-15=-98/920, 6-15=-537/178, 6-13=-665/104, 7-13=-51/802, 9-12=-42/255, 10-12=-24/1134, 8-12=-1472/155 NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 11. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Copper_Run Truss T23 Truss Type ROOF SPECIAL Qty 1 Ply 1 4 Copper Run Job Reference (optional) I38309427 8.240 s Jul 14 2019 MiTek Industries, Inc. Mon Aug 26 12:36:03 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:30gw6Zi9UeCey_72UT9oFIyJDSk-Rg1Zgrp1hk1PK4wQXUPZVZKY20hGWn7VAQ2jwZyjzpw Scale = 1:77.3 1 2 3 4 5 6 7 8 9 15 14 13 12 11 10 3x8 5x6 5x8 6x6 5x12 2x4 4x8 8x10 4x6 3x6 3x6 2x4 3x8 4x8 3x6 0-1-150-1-158-11-9 8-11-9 17-11-8 8-11-15 24-6-3 6-6-10 26-11-15 2-5-12 34-8-0 7-8-1 35-11-0 1-3-0 8-11-9 8-11-9 17-11-8 8-11-15 24-6-3 6-6-10 26-11-15 2-5-12 34-8-0 7-8-1 35-11-0 1-3-0 0-11-38-4-81-11-1212-10-141-11-128-4-88.00 12 10.00 12 Plate Offsets (X,Y)-- [6:0-4-0,0-1-14], [7:0-3-11,Edge], [8:0-6-0,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB Matrix-MSH 0.96 0.87 0.37 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.14 -0.43 0.10 (loc) 10-11 13-15 10 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 161 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 4-5,7-8: 2x4 SPF 2100F 1.8E BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 9-10: 2x4 SPF-S Stud, 3-13,5-13,6-13: 2x4 SPF No.2 SLIDER Left 2x6 SPF No.2 3-0-0 BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals, and 2-0-0 oc purlins (4-9-15 max.): 6-7, 8-9. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-13, 6-13, 6-11 REACTIONS.(lb/size)10=1431/Mechanical, 1=1431/Mechanical Max Horz 1=298(LC 5) Max Uplift 10=-60(LC 7), 1=-60(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-3=-1935/184, 3-5=-1414/235, 5-6=-1362/243, 6-7=-1202/198, 7-8=-1717/167 BOT CHORD 1-15=-97/1528, 13-15=-97/1528, 11-13=0/1364, 10-11=-109/972 WEBS 3-15=0/338, 3-13=-629/205, 5-13=-110/935, 6-13=-532/171, 6-11=-548/69, 7-11=0/659, 8-11=-16/255, 8-10=-1727/288 NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 10, 1. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Copper_Run Truss T24 Truss Type ROOF SPECIAL Qty 1 Ply 1 4 Copper Run Job Reference (optional) I38309428 8.240 s Jul 14 2019 MiTek Industries, Inc. Mon Aug 26 12:36:04 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:30gw6Zi9UeCey_72UT9oFIyJDSk-vtbxtBpfS29GyEVd5Bwo2ntkxQ?tF6IfP4nHS?yjzpv Scale = 1:77.3 1 2 3 4 5 6 7 8 14 13 12 11 10 9 3x6 5x6 5x12 5x6 6x6 8x10 4x6 3x6 3x6 2x4 3x8 4x8 3x4 3x8 8-11-9 8-11-9 17-11-8 8-11-15 28-11-15 11-0-7 35-11-0 6-11-1 8-11-9 8-11-9 17-11-8 8-11-15 27-0-3 9-0-10 28-11-15 1-11-12 35-11-0 6-11-1 0-11-36-8-812-10-141-1-36-8-88.00 12 10.00 12 Plate Offsets (X,Y)-- [6:0-6-0,0-1-14], [7:0-3-0,0-2-1] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB Matrix-MSH 0.95 0.91 0.88 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.31 -0.84 0.09 (loc) 10-12 10-12 9 l/defl >999 >508 n/a L/d 240 180 n/a PLATES MT20 Weight: 157 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 5-6: 2x4 SPF 2100F 1.8E BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 3-12,5-12,6-12: 2x4 SPF No.2, 8-9: 2x4 SPF-S Stud SLIDER Left 2x6 SPF No.2 3-0-0 BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals, and 2-0-0 oc purlins (4-5-7 max.): 6-7. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-12, 6-12 REACTIONS.(lb/size)1=1431/Mechanical, 9=1431/0-3-8 Max Horz 1=290(LC 5) Max Uplift 1=-61(LC 6), 9=-60(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-3=-1735/184, 3-5=-1422/232, 5-6=-1420/224, 6-7=-1255/171, 7-8=-1764/143, 8-9=-1381/122 BOT CHORD 1-14=-94/1527, 12-14=-94/1527, 10-12=-26/1492 WEBS 3-14=0/319, 3-12=-622/209, 5-12=-73/890, 6-12=-565/193, 6-10=-792/129, 7-10=-15/810, 8-10=0/1054 NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 9. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Copper_Run Truss T25 Truss Type ROOF SPECIAL Qty 1 Ply 1 4 Copper Run Job Reference (optional) I38309429 8.240 s Jul 14 2019 MiTek Industries, Inc. Mon Aug 26 12:36:06 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:30gw6Zi9UeCey_72UT9oFIyJDSk-rFjhItrv_fP_BYf?CcyG7Cy3xDiej5wxsOGOXtyjzpt Scale = 1:77.3 1 2 3 4 5 6 7 8 9 10 17 16 15 14 13 12 11 3x6 5x6 3x6 5x8 5x6 4x6 8x10 4x6 3x6 3x6 2x4 3x8 3x6 4x8 3x4 3x4 3x6 0-1-158-11-9 8-11-9 17-11-8 8-11-15 26-11-7 8-11-15 29-6-3 2-6-12 30-11-15 1-5-12 35-11-0 4-11-1 8-11-9 8-11-9 17-11-8 8-11-15 26-11-7 8-11-15 29-6-3 2-6-12 30-11-15 1-5-12 35-11-0 4-11-1 0-11-35-0-812-10-141-1-35-0-88.00 12 10.00 12 Plate Offsets (X,Y)-- [8:0-4-0,0-1-14], [9:0-3-0,0-2-1], [10:0-3-0,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB Matrix-MSH 0.98 0.89 0.56 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.15 -0.45 0.10 (loc) 13-15 13-15 11 l/defl >999 >959 n/a L/d 240 180 n/a PLATES MT20 Weight: 161 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 6-8: 2x4 SPF 2100F 1.8E BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 3-15,5-15,7-15: 2x4 SPF No.2, 10-11: 2x4 SPF-S Stud SLIDER Left 2x6 SPF No.2 3-0-0 BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals, and 2-0-0 oc purlins (5-0-0 max.): 8-9. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-15, 7-15 REACTIONS.(lb/size)1=1431/Mechanical, 11=1431/0-3-8 Max Horz 1=290(LC 5) Max Uplift 1=-61(LC 6), 11=-60(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-3=-1738/183, 3-5=-1417/234, 5-7=-1421/233, 7-8=-1783/183, 8-9=-1247/158, 9-10=-1708/147, 10-11=-1375/122 BOT CHORD 1-17=-94/1529, 15-17=-94/1529, 13-15=-27/1522, 12-13=-28/1519 WEBS 3-17=0/333, 3-15=-631/207, 5-15=-89/894, 7-15=-619/201, 8-12=-899/19, 9-12=0/707, 10-12=0/1136, 7-13=0/314 NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 11. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Copper_Run Truss T26 Truss Type ROOF SPECIAL Qty 1 Ply 1 4 Copper Run Job Reference (optional) I38309430 8.240 s Jul 14 2019 MiTek Industries, Inc. Mon Aug 26 12:36:07 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:30gw6Zi9UeCey_72UT9oFIyJDSk-JRH4WDsXlzXrpiECmJTVgPVF9d25SaW5520x3Kyjzps Scale = 1:82.9 1 2 3 4 5 6 7 8 9 10 17 16 15 14 13 12 11 3x6 5x10 MT18HS 3x6 6x6 5x6 4x6 8x10 4x6 3x6 3x6 2x4 3x8 3x6 3x4 4x8 2x4 3x6 0-1-158-11-9 8-11-9 17-7-12 8-8-3 17-11-8 0-3-12 18-3-4 0-3-12 26-11-8 8-8-4 32-0-2 5-0-10 32-11-15 0-11-12 35-11-0 2-11-1 8-11-9 8-11-9 17-7-12 8-8-3 17-11-8 0-3-12 18-3-4 0-3-12 26-11-8 8-8-4 32-0-2 5-0-10 32-11-15 0-11-12 35-11-0 2-11-1 0-11-33-4-812-8-61-1-33-4-88.00 12 10.00 12 Plate Offsets (X,Y)-- [8:0-2-15,Edge], [9:0-3-12,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB Matrix-MSH 0.95 0.87 0.41 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.14 -0.41 0.10 (loc) 13-15 13-15 11 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 157 lb FT = 20% GRIP 169/123 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 6-8: 2x4 SPF 2100F 1.8E BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 3-15,7-15,5-15: 2x4 SPF No.2, 10-11: 2x4 SPF-S Stud SLIDER Left 2x6 SPF No.2 3-0-0 BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals, and 2-0-0 oc purlins (5-5-0 max.): 8-9. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-15, 7-15 REACTIONS.(lb/size)1=1431/Mechanical, 11=1431/0-3-8 Max Horz 1=288(LC 5) Max Uplift 1=-61(LC 6), 11=-60(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-3=-1737/182, 3-5=-1420/232, 5-7=-1422/231, 7-8=-1860/188, 8-9=-1158/119, 9-10=-1565/121, 10-11=-1400/102 BOT CHORD 1-17=-93/1528, 15-17=-93/1528, 13-15=-23/1519, 12-13=-59/1518 WEBS 3-17=0/334, 3-15=-622/204, 7-15=-607/195, 7-13=0/321, 9-12=-15/742, 10-12=-29/1184, 8-12=-1105/83, 5-15=-84/876 NOTES-(11-12) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) The Fabrication Tolerance at joint 5 = 8% 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 8) Refer to girder(s) for truss to truss connections. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 11. 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Copper_Run Truss T27 Truss Type ROOF SPECIAL Qty 1 Ply 1 4 Copper Run Job Reference (optional) I38309431 8.240 s Jul 14 2019 MiTek Industries, Inc. Mon Aug 26 12:36:08 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:30gw6Zi9UeCey_72UT9oFIyJDSk-neqSjZs9WGfiQrpOK1_kCd1QO1OrB1XEKilUbmyjzpr Scale = 1:75.1 1 2 3 4 5 6 7 8 9 10 18 17 16 15 14 13 12 11 3x8 5x8 5x6 5x6 5x12 5x6 8x10 4x6 3x6 3x6 2x4 3x4 3x8 3x4 2x4 5x8 3x6 0-1-150-1-158-11-9 8-11-9 15-1-12 6-2-3 20-9-4 5-7-8 26-11-8 6-2-4 34-6-2 7-6-10 34-11-15 0-5-12 35-11-0 0-11-1 8-11-9 8-11-9 15-1-12 6-2-3 20-9-4 5-7-8 26-11-8 6-2-4 34-6-2 7-6-10 34-11-15 0-5-12 35-11-0 0-11-1 0-11-310-10-71-8-811-0-61-1-310-10-78.00 12 10.00 12 Plate Offsets (X,Y)-- [4:0-3-8,0-1-8], [5:0-4-0,0-1-9], [6:0-3-1,Edge], [7:0-1-12,0-1-12], [8:0-6-0,0-2-6] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB Matrix-MSH 0.92 0.84 0.42 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.10 -0.29 0.10 (loc) 12-13 12-13 11 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 172 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 7-8: 2x6 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 5-16,5-15,6-15: 2x4 SPF No.2, 10-11: 2x4 SPF-S Stud SLIDER Left 2x6 SPF No.2 3-0-0 BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals, and 2-0-0 oc purlins (5-0-0 max.): 5-6, 8-9. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-16, 5-15, 7-15 REACTIONS.(lb/size)1=1431/0-3-8, 11=1431/0-3-8 Max Horz 1=247(LC 5) Max Uplift 1=-52(LC 6), 11=-52(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-3=-1919/193, 3-5=-1543/249, 5-6=-1186/241, 6-7=-1542/246, 7-8=-1905/184, 8-9=-748/25, 9-10=-937/15, 10-11=-1496/0 BOT CHORD 1-18=-59/1507, 16-18=-59/1507, 15-16=-6/1189, 13-15=-24/1503, 12-13=-79/1298 WEBS 3-18=0/287, 3-16=-481/176, 5-16=-51/478, 6-15=-24/476, 7-15=-467/154, 7-13=0/269, 10-12=0/1223, 9-12=-86/527, 8-12=-1449/259 NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 11. 7) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Copper_Run Truss T28 Truss Type HIP Qty 1 Ply 1 4 Copper Run Job Reference (optional) I38309432 8.240 s Jul 14 2019 MiTek Industries, Inc. Mon Aug 26 12:36:09 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:30gw6Zi9UeCey_72UT9oFIyJDSk-FqOqwvtnHanZ2?OatkWzlqae?RnywU0OYMV28Cyjzpq Scale = 1:67.8 1 2 3 4 5 6 7 8 9 10 11 12 13 19 18 17 16 15 14 3x6 5x6 5x6 3x6 8x10 4x6 3x6 3x6 2x4 3x8 3x4 3x8 3x6 2x4 8x10 4x6 3x6 0-1-156-10-0 6-10-0 12-7-2 5-9-2 23-3-14 10-8-12 29-1-0 5-9-2 35-11-0 6-10-0 -0-11-0 0-11-0 6-10-0 6-10-0 12-7-2 5-9-2 17-11-8 5-4-6 23-3-14 5-4-6 29-1-0 5-9-2 35-11-0 6-10-0 36-10-0 0-11-0 0-11-39-2-09-3-150-11-39-2-08.00 12 Plate Offsets (X,Y)-- [6:0-3-1,Edge], [8:0-3-1,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB Matrix-MS 0.74 0.66 0.41 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.30 -0.81 0.11 (loc) 15-18 15-18 12 l/defl >999 >535 n/a L/d 240 180 n/a PLATES MT20 Weight: 159 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF 2100F 1.8E *Except* 16-17: 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 7-18,7-15: 2x4 SPF No.2 SLIDER Left 2x6 SPF No.2 3-0-0, Right 2x6 SPF No.2 3-0-0 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-1-15 oc purlins, except 2-0-0 oc purlins (4-10-5 max.): 6-8. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 7-18, 7-15 REACTIONS.(lb/size)2=1492/0-3-8, 12=1492/0-3-8 Max Horz 2=195(LC 5) Max Uplift 2=-71(LC 6), 12=-71(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-1944/197, 4-6=-1704/228, 6-7=-1343/224, 7-8=-1343/224, 8-10=-1704/228, 10-12=-1944/197 BOT CHORD 2-19=-102/1543, 18-19=-102/1543, 15-18=-52/1455, 14-15=-48/1543, 12-14=-48/1543 WEBS 4-18=-282/158, 6-18=-27/569, 7-18=-328/183, 7-15=-328/183, 8-15=-27/569, 10-15=-282/158 NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 12. 7) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Copper_Run Truss T29 Truss Type HIP Qty 1 Ply 1 4 Copper Run Job Reference (optional) I38309433 8.240 s Jul 14 2019 MiTek Industries, Inc. Mon Aug 26 12:36:10 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:30gw6Zi9UeCey_72UT9oFIyJDSk-k0yC8FuQ2uvQg9ymRS1CH27pJr3PfySXn0Ebgfyjzpp Scale = 1:62.5 1 2 3 4 5 6 7 8 9 10 11 16 15 14 13 12 5x6 5x6 8x10 4x6 3x6 3x8 2x4 2x4 3x8 3x8 2x4 8x10 4x6 3x6 10-1-2 10-1-2 17-11-8 7-10-6 25-9-14 7-10-6 35-11-0 10-1-2 -0-11-0 0-11-0 5-6-11 5-6-11 10-1-2 4-6-7 17-11-8 7-10-6 25-9-14 7-10-6 30-4-5 4-6-7 35-11-0 5-6-11 36-10-0 0-11-0 0-11-37-6-07-7-150-11-37-6-08.00 12 Plate Offsets (X,Y)-- [5:0-3-1,Edge], [7:0-3-1,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB Matrix-MSH 0.77 0.83 0.33 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.15 -0.38 0.14 (loc) 12-23 12-23 10 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 151 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 6-16,6-12: 2x4 SPF No.2 SLIDER Left 2x6 SPF No.2 3-0-0, Right 2x6 SPF No.2 3-0-0 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-3-5 oc purlins, except 2-0-0 oc purlins (4-0-6 max.): 5-7. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 6-16, 6-12 REACTIONS.(lb/size)2=1492/0-3-8, 10=1492/0-3-8 Max Horz 2=157(LC 5) Max Uplift 2=-58(LC 6), 10=-58(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-1941/217, 4-5=-1793/223, 5-6=-1460/218, 6-7=-1460/218, 7-8=-1793/223, 8-10=-1941/217 BOT CHORD 2-16=-161/1540, 14-16=-142/1854, 12-14=-142/1854, 10-12=-74/1540 WEBS 5-16=-9/605, 6-16=-619/178, 6-14=0/301, 6-12=-619/178, 7-12=-9/605 NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 10. 7) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Copper_Run Truss T30 Truss Type HIP Qty 1 Ply 1 4 Copper Run Job Reference (optional) I38309434 8.240 s Jul 14 2019 MiTek Industries, Inc. Mon Aug 26 12:36:12 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:30gw6Zi9UeCey_72UT9oFIyJDSk-gP4zZwvgaVA8vT69Zs3gNTC8qeo07mZqFJjilXyjzpn Scale: 3/16"=1' 1 2 3 4 5 6 7 8 9 10 11 16 15 14 13 12 5x6 3x6 8x10 4x6 3x8 MT18HS3x6 3x4 3x4 3x4 3x6 8x10 4x6 5x6 3x8 MT18HS 0-1-157-7-2 7-7-2 17-11-8 10-4-6 28-3-14 10-4-6 35-11-0 7-7-2 -0-11-0 0-11-0 7-7-2 7-7-2 14-6-1 6-10-15 21-4-15 6-10-15 28-3-14 6-10-15 35-11-0 7-7-2 36-10-0 0-11-0 0-11-35-10-05-11-150-11-35-10-08.00 12 Plate Offsets (X,Y)-- [4:0-3-1,Edge], [8:0-3-1,Edge], [12:0-2-8,0-1-8], [16:0-2-8,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB Matrix-MSH 0.77 0.70 0.74 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.23 -0.66 0.15 (loc) 12-14 12-14 10 l/defl >999 >653 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 132 lb FT = 20% GRIP 197/144 197/144 LUMBER- TOP CHORD 2x4 SPF 2100F 1.8E *Except* 4-6,6-8: 2x4 SPF No.2 BOT CHORD 2x4 SPF 2100F 1.8E WEBS 2x3 SPF No.2 SLIDER Left 2x6 SPF No.2 3-0-0, Right 2x6 SPF No.2 3-0-0 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-8-4 oc purlins, except 2-0-0 oc purlins (3-5-8 max.): 4-8. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 5-16, 7-12 REACTIONS.(lb/size)2=1492/0-3-8, 10=1492/0-3-8 Max Horz 2=118(LC 5) Max Uplift 2=-77(LC 5), 10=-77(LC 4) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-1974/201, 4-5=-1554/212, 5-7=-2344/257, 7-8=-1554/212, 8-10=-1974/201 BOT CHORD 2-16=-173/1566, 14-16=-278/2272, 12-14=-243/2272, 10-12=-56/1566 WEBS 4-16=-20/737, 5-16=-987/245, 5-14=0/268, 7-14=0/268, 7-12=-987/245, 8-12=-20/737 NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 10. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Copper_Run Truss TG01 Truss Type COMMON GIRDER Qty 1 Ply 3 4 Copper Run Job Reference (optional) I38309435 8.240 s Jul 14 2019 MiTek Industries, Inc. Mon Aug 26 12:36:14 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:30gw6Zi9UeCey_72UT9oFIyJDSk-coCj_cxw66Qs9mGYgH58SuHXTSV2bfp7idCppQyjzpl Scale = 1:36.5 1 2 3 4 5 9 8 7 6161718192021 22 23 5x8 4x8 3x6 3x6 8x8 3x6 3x6 10x10 10x10 4-11-0 4-11-0 9-9-8 4-10-8 14-8-0 4-10-8 19-7-0 4-11-0 4-11-0 4-11-0 9-9-8 4-10-8 14-8-0 4-10-8 19-7-0 4-11-0 0-9-35-7-150-9-36.00 12 Plate Offsets (X,Y)-- [1:0-0-4,0-0-0], [1:0-4-11,0-2-1], [1:Edge,0-3-5], [5:0-0-4,0-0-0], [5:0-4-11,0-2-1], [5:Edge,0-3-5] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB Matrix-MSH 0.57 0.60 0.82 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.11 -0.28 0.06 (loc) 6-7 6-7 5 l/defl >999 >846 n/a L/d 240 180 n/a PLATES MT20 Weight: 273 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SP 2400F 2.0E WEBS 2x3 SPF No.2 WEDGE Left: 2x6 SPF No.2, Right: 2x6 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-11-9 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=7405/0-5-8, 5=6865/0-5-8 Max Horz 1=48(LC 12) Max Uplift 1=-377(LC 5), 5=-350(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-11269/590, 2-3=-8455/470, 3-4=-8453/470, 4-5=-11202/588 BOT CHORD 1-9=-522/9991, 7-9=-522/9991, 6-7=-474/9923, 5-6=-474/9923 WEBS 3-7=-337/7144, 4-7=-2797/219, 4-6=-87/2491, 2-7=-2875/222, 2-9=-88/2541 NOTES-(9-10) 1) 3-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-5-0 oc. Webs connected as follows: 2x3 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 1=377, 5=350. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 1417 lb down and 73 lb up at 1-4-4, 1411 lb down and 72 lb up at 3-4-4, 1411 lb down and 72 lb up at 5-4-4, 1411 lb down and 72 lb up at 7-4-4, 1411 lb down and 72 lb up at 9-4-4, 1411 lb down and 72 lb up at 11-4-4, 1411 lb down and 73 lb up at 13-4-4, and 1411 lb down and 73 lb up at 15-4-4, and 1411 lb down and 73 lb up at 17-4-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard Continued on page 2 August 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Copper_Run Truss TG01 Truss Type COMMON GIRDER Qty 1 Ply 3 4 Copper Run Job Reference (optional) I38309435 8.240 s Jul 14 2019 MiTek Industries, Inc. Mon Aug 26 12:36:14 2019 Page 2 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:30gw6Zi9UeCey_72UT9oFIyJDSk-coCj_cxw66Qs9mGYgH58SuHXTSV2bfp7idCppQyjzpl LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-3=-60, 3-5=-60, 10-13=-20 Concentrated Loads (lb) Vert: 8=-1411(F) 16=-1417(F) 17=-1411(F) 18=-1411(F) 19=-1411(F) 20=-1411(F) 21=-1411(F) 22=-1411(F) 23=-1411(F) 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Copper_Run Truss TG02 Truss Type HALF HIP GIRDER Qty 3 Ply 1 4 Copper Run Job Reference (optional) I38309436 8.240 s Jul 14 2019 MiTek Industries, Inc. Mon Aug 26 12:36:16 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:30gw6Zi9UeCey_72UT9oFIyJDSk-YAJTOIzBdkgZO4Qwoi8cXJMzPFJ93lwQ9xhvuIyjzpj Scale = 1:15.2 1 2 3 4 7 6 5 5x6 2x4 2x4 2x4 3x4 2x4 0-1-41-7-13 1-7-13 3-10-8 2-2-11 -0-11-0 0-11-0 1-7-13 1-7-13 3-10-8 2-2-11 1-1-32-4-72-5-112-0-150-3-82-4-710.00 12 Plate Offsets (X,Y)-- [3:0-4-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB Matrix-MR 0.15 0.11 0.01 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.01 -0.01 0.00 (loc) 6 6 5 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 15 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 3-6: 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-10-8 oc purlins, except end verticals, and 2-0-0 oc purlins: 3-4. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)7=215/0-3-8, 5=132/0-1-8 Max Horz 7=73(LC 4) Max Uplift 7=-53(LC 5), 5=-43(LC 4) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(12-13) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 6) Bearing at joint(s) 5 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 5. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 7, 5. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 65 lb down and 47 lb up at 1-7-13 on top chord, and 0 lb down and 3 lb up at 1-7-13, and 2 lb down and 13 lb up at 1-11-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 11) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 12) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 13) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 2-3=-60, 3-4=-60, 5-7=-20 Concentrated Loads (lb) Vert: 6=3(F) August 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Copper_Run Truss TG03 Truss Type HALF HIP GIRDER Qty 1 Ply 1 4 Copper Run Job Reference (optional) I38309437 8.240 s Jul 14 2019 MiTek Industries, Inc. Mon Aug 26 12:36:17 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:30gw6Zi9UeCey_72UT9oFIyJDSk-0NtscezpO1oQ0E?7LQfr4Wv88feOoBzZObRTQlyjzpi Scale = 1:15.2 1 2 3 4 10 9 8 7 6 5 5x6 2x4 2x4 2x4 2x4 3x4 2x4 2x4 2x4 0-1-41-7-13 1-7-13 2-3-8 0-7-11 3-10-8 1-7-0 -0-11-0 0-11-0 1-7-13 1-7-13 2-3-8 0-7-11 3-10-8 1-7-0 1-1-32-4-72-5-111-4-150-11-81-8-70-8-02-4-710.00 12 Plate Offsets (X,Y)-- [3:0-4-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB Matrix-MR 0.15 0.11 0.09 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.01 -0.01 -0.01 (loc) 7 7 5 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 15 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 3-9,6-8: 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-10-8 oc purlins, except end verticals, and 2-0-0 oc purlins: 3-4. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)10=215/0-3-8, 5=132/0-1-8 Max Horz 10=67(LC 5) Max Uplift 10=-50(LC 5), 5=-44(LC 4) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(12-13) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 6) Bearing at joint(s) 5 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 5. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 10, 5. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 65 lb down and 47 lb up at 1-7-13 on top chord, and 0 lb down and 3 lb up at 1-9-1, and 2 lb down and 13 lb up at 2-2-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 11) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 12) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 13) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 2-3=-60, 3-4=-60, 8-10=-20, 5-6=-20 Concentrated Loads (lb) Vert: 8=0(B) 9=3(B) August 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Copper_Run Truss TG04 Truss Type HIP GIRDER Qty 1 Ply 1 4 Copper Run Job Reference (optional) I38309438 8.240 s Jul 14 2019 MiTek Industries, Inc. Mon Aug 26 12:36:19 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:30gw6Zi9UeCey_72UT9oFIyJDSk-zl?c1K?3wf28FY8VTrhJ9x_M6TF?GtdssvwaUdyjzpg Scale: 3/16"=1' 1 2 3 4 5 6 7 8 9 10 11 21 20 19 18 17 16 15 14 13 12222324252627282930313233343536 5x8 3x8 8x16 5x10 MT18HS4x8 6x10 2x4 3x8 2x4 2x4 4x8 2x4 6x8 4x8 8x16 5x8 5x10 MT18HS0-1-25-1-2 5-1-2 10-4-2 5-3-0 15-5-14 5-1-12 20-7-10 5-1-12 25-9-6 5-1-12 30-9-14 5-0-8 35-11-0 5-1-2 -0-11-0 0-11-0 5-1-2 5-1-2 10-4-2 5-3-0 15-5-14 5-1-12 20-7-10 5-1-12 25-9-6 5-1-12 30-9-14 5-0-8 35-11-0 5-1-2 36-10-0 0-11-0 0-11-34-2-134-3-150-11-34-2-138.00 12 Plate Offsets (X,Y)-- [3:0-4-12,0-2-0], [9:0-4-0,0-1-9], [12:Edge,0-7-7], [12:0-2-12,0-0-0], [20:0-2-8,0-2-0], [21:0-2-12,0-0-0], [21:Edge,0-7-7] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB Matrix-MSH 0.70 0.42 0.97 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.34 -0.69 0.11 (loc) 16-17 16-17 12 l/defl >999 >614 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 181 lb FT = 20% GRIP 197/144 244/190 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 3-6,6-9: 2x4 SPF 2100F 1.8E BOT CHORD 2x6 SP 2400F 2.0E WEBS 2x3 SPF No.2 *Except* 2-21,10-12: 2x6 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-7-6 oc purlins, except end verticals, and 2-0-0 oc purlins (3-0-9 max.): 3-9. BOT CHORD Rigid ceiling directly applied or 7-9-10 oc bracing. WEBS 1 Row at midpt 5-19, 8-13 REACTIONS.(lb/size)21=2453/0-3-8, 12=2454/0-3-8 Max Horz 21=100(LC 4) Max Uplift 21=-664(LC 4), 12=-664(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3300/985, 3-4=-4639/1471, 4-5=-4639/1470, 5-7=-5558/1761, 7-8=-5558/1761, 8-9=-2664/836, 9-10=-3290/983, 2-21=-2291/645, 10-12=-2277/640 BOT CHORD 20-21=-270/666, 19-20=-849/2675, 17-19=-1785/5601, 16-17=-1785/5601, 14-16=-1416/4594, 13-14=-1416/4594, 12-13=-180/680 WEBS 3-19=-836/2469, 4-19=-347/144, 5-19=-1222/422, 5-17=-128/442, 7-16=-298/125, 8-16=-421/1225, 8-14=-111/414, 8-13=-2456/832, 9-13=-478/1529, 2-20=-669/2038, 10-13=-668/2014 NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 21=664, 12=664. 7) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 112 lb down and 57 lb up at 2-4-8, 114 lb down and 55 lb up at 4-4-8, 114 lb down and 65 lb up at 6-4-8, 114 lb down and 65 lb up at 8-4-8, 114 lb down and 65 lb up at 10-4-8, 114 lb down and 65 lb up at 12-4-8, 114 lb down and 65 lb up at 14-4-8, 114 lb down and 65 lb up at 16-4-8, 114 lb down and 65 lb up at 17-11-8, 114 lb down and 65 lb up at 19-6-8, 114 lb down and 65 lb up at 21-6-8, 114 lb down and 65 lb up at 23-6-8, 114 lb down and 65 lb up at 25-6-8, 114 lb down and 65 lb up at 27-6-8, 114 lb down and 65 lb up at 29-6-8, and 114 lb down and 55 lb up at 31-6-8, and 112 lb down and 57 lb up at 33-6-8 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) StandardContinued on page 2 August 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Copper_Run Truss TG04 Truss Type HIP GIRDER Qty 1 Ply 1 4 Copper Run Job Reference (optional) I38309438 8.240 s Jul 14 2019 MiTek Industries, Inc. Mon Aug 26 12:36:19 2019 Page 2 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:30gw6Zi9UeCey_72UT9oFIyJDSk-zl?c1K?3wf28FY8VTrhJ9x_M6TF?GtdssvwaUdyjzpg LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 2-3=-60, 3-9=-60, 9-10=-60, 10-11=-60, 12-21=-20 Concentrated Loads (lb) Vert: 19=-114 14=-114 22=-112 23=-114 24=-114 25=-114 26=-114 27=-114 28=-114 29=-114 30=-114 31=-114 32=-114 33=-114 34=-114 35=-114 36=-112 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Copper_Run Truss TG05 Truss Type HIP GIRDER Qty 1 Ply 2 4 Copper Run Job Reference (optional) I38309439 8.240 s Jul 14 2019 MiTek Industries, Inc. Mon Aug 26 12:36:21 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:30gw6Zi9UeCey_72UT9oFIyJDSk-v87MS?0JSGIsUrIuaFjoEM4j_GylktL9JDPgZWyjzpe Scale = 1:20.0 1 2 3 4 5 10 9 8 7 6 11 12 13 14 15 16 17 18 19 4x6 4x8 4x8 4x6 3x4 3x4 8x8 8x8 2x4 8x8 1-9-0 1-9-0 5-9-12 4-0-12 9-10-8 4-0-12 11-7-8 1-9-0 1-9-0 1-9-0 5-9-12 4-0-12 9-10-8 4-0-12 11-7-8 1-9-0 1-1-32-6-111-1-32-6-1110.00 12 Plate Offsets (X,Y)-- [1:0-3-0,0-1-8], [2:0-6-0,0-1-12], [4:0-6-0,0-1-12], [5:0-3-0,0-1-8], [7:0-2-8,0-4-0], [9:0-2-8,0-4-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB Matrix-MSH 0.61 0.34 0.57 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.05 -0.13 0.01 (loc) 8 8-9 6 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 114 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SP 2400F 2.0E WEBS 2x3 SPF No.2 *Except* 1-10,5-6: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (4-11-0 max.): 2-4. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)10=4290/0-5-8, 6=5093/0-3-8 Max Horz 10=59(LC 4) Max Uplift 10=-334(LC 4), 6=-370(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-4282/357, 2-3=-5910/504, 3-4=-5910/504, 4-5=-4071/347, 1-10=-4234/341, 5-6=-4048/332 BOT CHORD 8-9=-302/3283, 7-8=-277/3114 WEBS 2-9=-46/1178, 2-8=-265/2992, 4-8=-275/3184, 4-7=-34/947, 1-9=-295/3343, 5-7=-290/3233 NOTES-(11-12) 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-7-0 oc. Webs connected as follows: 2x3 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 5) Provide adequate drainage to prevent water ponding. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) Bearings are assumed to be: Joint 10 SPF No.2 crushing capacity of 425 psi. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 10=334, 6=370. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 86 lb down and 48 lb up at 1-9-0, 42 lb down and 37 lb up at 3-9-12, 42 lb down and 37 lb up at 5-9-12, and 42 lb down and 37 lb up at 7-9-12, and 86 lb down and 48 lb up at 9-10-8 on top chord, and 1411 lb down and 72 lb up at 1-3-12, 6 lb down and 34 lb up at 1-9-0, 1411 lb down and 73 lb up at 3-3-12, 4 lb down and 17 lb up at 3-9-12, 1411 lb down and 73 lb up at 5-3-12, 4 lb down and 17 lb up at 5-9-12, 1411 lb down and 73 lb up at 7-3-12, 4 lb down and 17 lb up at 7-9-12, 1411 lb down and 73 lb up at 9-3-12, and 6 lb down and 34 lb up at 9-9-12, and 1425 lb down and 68 lb up at 11-5-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. Continued on page 2 August 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Copper_Run Truss TG05 Truss Type HIP GIRDER Qty 1 Ply 2 4 Copper Run Job Reference (optional) I38309439 8.240 s Jul 14 2019 MiTek Industries, Inc. Mon Aug 26 12:36:21 2019 Page 2 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:30gw6Zi9UeCey_72UT9oFIyJDSk-v87MS?0JSGIsUrIuaFjoEM4j_GylktL9JDPgZWyjzpe 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 2-4=-60, 4-5=-60, 6-10=-20 Concentrated Loads (lb) Vert: 6=-1425(F) 9=4(B) 8=-2(B) 7=4(B) 13=-1411(F) 14=-1411(F) 15=-2(B) 16=-1411(F) 17=-1411(F) 18=-2(B) 19=-1411(F) 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Copper_Run Truss TG06 Truss Type HIP GIRDER Qty 1 Ply 1 4 Copper Run Job Reference (optional) I38309440 8.240 s Jul 14 2019 MiTek Industries, Inc. Mon Aug 26 12:36:23 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:30gw6Zi9UeCey_72UT9oFIyJDSk-rWE7sh2a_tYak9SGigmGJn95d4d4Cq1SmXundOyjzpc Scale = 1:36.3 1 2 3 4 5 6 7 13 12 11 10 9 8 14 15 16 17 18 4x10 4x10 3x4 4x6 3x6 3x8 2x4 3x6 4x6 3x4 4x6 0-1-23-10-8 3-10-8 9-11-8 6-1-0 16-0-8 6-1-0 19-11-0 3-10-8 -0-11-0 0-11-0 3-10-8 3-10-8 9-11-8 6-1-0 16-0-8 6-1-0 19-11-0 3-10-8 20-10-0 0-11-0 1-1-34-2-134-3-151-1-34-2-1310.00 12 Plate Offsets (X,Y)-- [2:0-2-14,0-2-0], [6:0-2-14,0-2-0], [9:0-2-8,0-1-8], [12:0-2-8,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB Matrix-MSH 0.47 0.35 0.37 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.06 -0.14 0.02 (loc) 10-12 10-12 8 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 91 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-13,6-8: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-8-15 oc purlins, except end verticals, and 2-0-0 oc purlins (4-0-0 max.): 3-5. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)13=1360/0-3-8, 8=1359/0-3-8 Max Horz 13=101(LC 4) Max Uplift 13=-344(LC 4), 8=-343(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1499/436, 3-4=-1803/561, 4-5=-1803/561, 5-6=-1498/436, 2-13=-1287/337, 6-8=-1286/336 BOT CHORD 10-12=-369/1108, 9-10=-312/1107 WEBS 3-10=-305/851, 4-10=-421/175, 5-10=-306/852, 2-12=-321/992, 6-9=-323/991 NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 13=344, 8=343. 7) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 112 lb down and 69 lb up at 1-11-8, 114 lb down and 65 lb up at 3-11-8, 114 lb down and 65 lb up at 5-11-8, 114 lb down and 65 lb up at 7-11-8, 114 lb down and 65 lb up at 9-11-8, 114 lb down and 65 lb up at 11-11-8, 114 lb down and 65 lb up at 13-11-8, and 114 lb down and 65 lb up at 15-11-8, and 112 lb down and 69 lb up at 17-11-8 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 2-3=-60, 3-5=-60, 5-6=-60, 6-7=-60, 8-13=-20 Continued on page 2 August 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Copper_Run Truss TG06 Truss Type HIP GIRDER Qty 1 Ply 1 4 Copper Run Job Reference (optional) I38309440 8.240 s Jul 14 2019 MiTek Industries, Inc. Mon Aug 26 12:36:23 2019 Page 2 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:30gw6Zi9UeCey_72UT9oFIyJDSk-rWE7sh2a_tYak9SGigmGJn95d4d4Cq1SmXundOyjzpc LOAD CASE(S) Standard Concentrated Loads (lb) Vert: 11=-114 12=-114 10=-114 9=-114 14=-112 15=-114 16=-114 17=-114 18=-112 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Copper_Run Truss TG07 Truss Type HIP GIRDER Qty 1 Ply 2 4 Copper Run Job Reference (optional) I38309441 8.240 s Jul 14 2019 MiTek Industries, Inc. Mon Aug 26 12:36:26 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:30gw6Zi9UeCey_72UT9oFIyJDSk-G5wFVj4SHow9bdBrNpJzxQnbXHaWP2QuTV6REjyjzpZ Scale = 1:65.1 1 2 3 4 5 6 7 8 9 10 11 22 21 20 19 18 17 16 15 14 13 122324252627 28 29 30 31 32 33 34 35 36 5x6 3x6 8x8 2x4 4x6 6x16 2x4 3x8 4x8 4x6 6x10 3x4 2x4 5x8 3x8 8x8 5x12 5x6 2-3-8 2-3-8 5-1-2 2-9-10 13-4-8 8-3-6 16-6-1 3-1-9 23-7-5 7-1-4 30-9-14 7-2-9 35-11-0 5-1-2 -0-11-0 0-11-0 2-3-8 2-3-8 5-1-2 2-9-10 13-4-8 8-3-6 16-6-1 3-1-9 23-7-5 7-1-4 30-9-14 7-2-9 35-11-0 5-1-2 36-10-0 0-11-0 0-11-34-2-134-3-150-11-30-8-04-2-138.00 12 Plate Offsets (X,Y)-- [4:0-3-0,0-2-3], [9:0-3-0,0-2-3], [12:Edge,0-6-2], [12:0-1-12,0-0-0], [19:0-2-8,0-2-0], [22:0-1-12,0-0-0], [22:Edge,0-6-2] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB Matrix-MSH 0.56 0.68 0.91 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.27 -0.55 0.13 (loc) 14-16 14-16 12 l/defl >999 >773 n/a L/d 240 180 n/a PLATES MT20 Weight: 318 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 4-7: 2x4 SPF 2100F 1.8E BOT CHORD 2x6 SPF No.2 *Except* 3-21,5-17: 2x3 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-22,10-12: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-11-5 oc purlins, except end verticals, and 2-0-0 oc purlins (4-10-9 max.): 4-9. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 8-13 REACTIONS.(lb/size)22=2454/0-3-8, 12=2457/0-3-8 Max Horz 22=99(LC 4) Max Uplift 22=-659(LC 4), 12=-663(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3910/1145, 3-4=-4168/1265, 4-5=-6484/2050, 5-6=-6424/2029, 6-8=-5740/1809, 8-9=-2781/868, 9-10=-3411/1014, 2-22=-2383/672, 10-12=-2336/655 BOT CHORD 21-22=-159/365, 19-20=-1003/3195, 18-19=-1090/3473, 5-18=-385/176, 16-17=-218/638, 14-16=-1645/5277, 13-14=-1645/5277, 12-13=-135/525 WEBS 3-19=-217/433, 4-19=-194/715, 4-18=-1112/3262, 16-18=-1646/5245, 6-18=-307/956, 6-16=-956/325, 8-16=-198/554, 8-14=-164/597, 8-13=-2866/973, 9-13=-470/1527, 10-13=-751/2279, 2-20=-837/2807 NOTES-(11-12) 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc, 2x3 - 1 row at 0-9-0 oc. Webs connected as follows: 2x3 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 5) Provide adequate drainage to prevent water ponding. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 22=659, 12=663. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. Continued on page 2 August 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Copper_Run Truss TG07 Truss Type HIP GIRDER Qty 1 Ply 2 4 Copper Run Job Reference (optional) I38309441 8.240 s Jul 14 2019 MiTek Industries, Inc. Mon Aug 26 12:36:26 2019 Page 2 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:30gw6Zi9UeCey_72UT9oFIyJDSk-G5wFVj4SHow9bdBrNpJzxQnbXHaWP2QuTV6REjyjzpZ NOTES-(11-12) 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 112 lb down and 57 lb up at 2-2-4, 114 lb down and 54 lb up at 4-4-8, 114 lb down and 64 lb up at 6-4-8, 114 lb down and 64 lb up at 8-4-8, 114 lb down and 64 lb up at 10-4-8, 114 lb down and 64 lb up at 12-4-8, 114 lb down and 65 lb up at 14-4-8, 114 lb down and 65 lb up at 16-4-8, 114 lb down and 65 lb up at 18-4-8, 114 lb down and 65 lb up at 19-6-8, 114 lb down and 65 lb up at 21-6-8, 114 lb down and 65 lb up at 23-6-8, 114 lb down and 65 lb up at 25-6-8, 114 lb down and 65 lb up at 27-6-8, 114 lb down and 65 lb up at 29-6-8, and 114 lb down and 55 lb up at 31-6-8, and 112 lb down and 57 lb up at 33-6-8 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 2-4=-60, 4-9=-60, 9-10=-60, 10-11=-60, 21-22=-20, 18-20=-20, 12-17=-20 Concentrated Loads (lb) Vert: 21=-112 16=-114 14=-114 23=-114 24=-114 25=-114 26=-114 27=-114 28=-114 29=-114 30=-114 31=-114 32=-114 33=-114 34=-114 35=-114 36=-112 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Copper_Run Truss TG08 Truss Type HIP GIRDER Qty 1 Ply 1 4 Copper Run Job Reference (optional) I38309442 8.240 s Jul 14 2019 MiTek Industries, Inc. Mon Aug 26 12:36:27 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:30gw6Zi9UeCey_72UT9oFIyJDSk-kIUdi354263?Cmm2xWqCTdKsDh398ia1h9s?mAyjzpY Scale = 1:21.9 1 2 3 4 5 6 10 9 8 7 11 12 13 4x6 4x6 2x4 2x4 3x4 3x4 3x6 3x6 0-1-22-10-0 2-10-0 5-3-8 2-5-8 8-1-8 2-10-0 -0-11-0 0-11-0 2-10-0 2-10-0 5-3-8 2-5-8 8-1-8 2-10-0 9-0-8 0-11-0 1-1-33-4-63-5-81-1-33-4-610.00 12 Plate Offsets (X,Y)-- [3:0-3-0,0-2-1], [4:0-3-0,0-2-1] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB Matrix-MSH 0.12 0.08 0.08 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.01 -0.01 0.00 (loc) 9 9 7 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 39 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-10,5-7: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 3-4. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)10=481/0-5-8, 7=481/0-5-8 Max Horz 10=81(LC 4) Max Uplift 10=-146(LC 5), 7=-146(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-394/138, 3-4=-263/122, 4-5=-394/137, 2-10=-431/142, 5-7=-431/141 BOT CHORD 8-9=-100/263 NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 10=146, 7=146. 7) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 70 lb down and 70 lb up at 2-0-12, and 68 lb down and 73 lb up at 4-0-12, and 70 lb down and 70 lb up at 6-0-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 2-3=-60, 3-4=-60, 4-5=-60, 5-6=-60, 7-10=-20 Concentrated Loads (lb) Vert: 11=-70 12=-68 13=-70 August 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Copper_Run Truss V01 Truss Type VALLEY Qty 1 Ply 1 4 Copper Run Job Reference (optional) I38309443 8.240 s Jul 14 2019 MiTek Industries, Inc. Mon Aug 26 12:36:28 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:30gw6Zi9UeCey_72UT9oFIyJDSk-CU20wP6ipQBsqwLEVELR0rsvX5K_t9nBwpbYJcyjzpX Scale = 1:22.2 1 2 3 43x12 4x8 3x12 2x4 13-0-6 13-0-6 13-0-14 0-0-8 6-6-7 6-6-7 13-0-14 6-6-7 0-0-43-3-40-0-46.00 12 Plate Offsets (X,Y)-- [1:0-9-11,Edge], [3:0-3-3,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB Matrix-SH 0.59 0.43 0.08 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 30 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=211/12-11-14, 3=211/12-11-14, 4=524/12-11-14 Max Horz 1=-29(LC 4) Max Uplift 1=-22(LC 6), 3=-26(LC 7), 4=-3(LC 6) Max Grav 1=215(LC 10), 3=215(LC 11), 4=524(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-4=-316/107 NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3, 4. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Copper_Run Truss V02 Truss Type Valley Qty 1 Ply 1 4 Copper Run Job Reference (optional) I38309444 8.240 s Jul 14 2019 MiTek Industries, Inc. Mon Aug 26 12:36:29 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:30gw6Zi9UeCey_72UT9oFIyJDSk-ggcO7k7KZjJjS4vQ2xtgZ2P79VepcdIK9TL5r2yjzpW Scale = 1:14.4 1 2 3 2x4 2x4 2x4 7-8-6 7-8-6 7-8-14 0-0-8 3-10-7 3-10-7 7-8-14 3-10-7 0-0-41-11-40-0-46.00 12 Plate Offsets (X,Y)-- [2:0-2-0,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB Matrix-P 0.41 0.52 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 15 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=259/7-7-14, 3=259/7-7-14 Max Horz 1=-16(LC 4) Max Uplift 1=-13(LC 6), 3=-13(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Copper_Run Truss V03 Truss Type GABLE Qty 1 Ply 1 4 Copper Run Job Reference (optional) I38309445 8.240 s Jul 14 2019 MiTek Industries, Inc. Mon Aug 26 12:36:31 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:30gw6Zi9UeCey_72UT9oFIyJDSk-c3j8YQ8b5LZRhO3pAMv8eTUZfIRQ4XodcnqCvxyjzpU Scale = 1:5.7 1 2 3 2x4 2x4 2x4 2-4-14 2-4-14 1-2-7 1-2-7 2-4-14 1-2-7 0-7-46.00 12 Plate Offsets (X,Y)-- [2:0-2-0,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB Matrix-P 0.02 0.06 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 3 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-4-14 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=61/2-4-14, 3=61/2-4-14 Max Horz 1=4(LC 5) Max Uplift 1=-3(LC 6), 3=-3(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Copper_Run Truss V04 Truss Type Valley Qty 2 Ply 1 4 Copper Run Job Reference (optional) I38309446 8.240 s Jul 14 2019 MiTek Industries, Inc. Mon Aug 26 12:36:39 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:30gw6Zi9UeCey_72UT9oFIyJDSk-NbCAD9EcDoZJecgLe120z9px9XAjy9noS0mdCTyjzpM Scale = 1:9.4 1 2 3 2x4 2x4 2x4 1-6-15 1-6-15 0-0-41-3-1210.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB Matrix-P 0.05 0.03 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 3 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 1-6-15 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=47/1-6-10, 3=47/1-6-10 Max Horz 1=30(LC 5) Max Uplift 3=-10(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 4_Copper_Run Truss V05 Truss Type Valley Qty 1 Ply 1 4 Copper Run Job Reference (optional) I38309447 8.240 s Jul 14 2019 MiTek Industries, Inc. Mon Aug 26 12:36:41 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:30gw6Zi9UeCey_72UT9oFIyJDSk-J_KwerGslPp0uwqklS4U2av68KmlQ2G5vKFkGMyjzpK Scale = 1:10.5 1 2 3 3x4 2x4 2x4 5-8-4 5-8-4 0-0-41-5-13.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB Matrix-P 0.73 0.44 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 11 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-8-4 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=173/5-7-4, 3=173/5-7-4 Max Horz 1=36(LC 5) Max Uplift 1=-13(LC 4), 3=-17(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 26,2019 PRODUCT CODE APPROVALSLATERAL BRACING LOCATIONIndicates location where bearings(supports) occur. Icons vary butreaction section indicates jointnumber where bearings occur.Min size shown is for crushing only.Indicated by symbol shown and/orby text in the bracing section of theoutput. Use T or I bracingif indicated.The first dimension is the plate width measured perpendicular to slots. Second dimension isthe length parallel to slots.Center plate on joint unless x, yoffsets are indicated.Dimensions are in ft-in-sixteenths.Apply plates to both sides of trussand fully embed teeth.1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI.2. Truss bracing must be designed by an engineer. For wide truss spacing, individual lateral braces themselves may require bracing, or alternative Tor I bracing should be considered.3. Never exceed the design loading shown and never stack materials on inadequately braced trusses.4. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties.5. Cut members to bear tightly against each other.6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI 1.7. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI 1.8. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication.9. Unless expressly noted, this design is not applicable for use with fire retardant, preservative treated, or green lumber.10. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection.11. Plate type, size, orientation and location dimensions indicated are minimum plating requirements.12. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified.13. Top chords must be sheathed or purlins provided at spacing indicated on design.14. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted.15. Connections not shown are the responsibility of others.16. Do not cut or alter truss member or plate without prior approval of an engineer.17. Install and load vertically unless indicated otherwise.18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use.19. Review all portions of this design (front, back, words and pictures) before use. Reviewing pictures alone is not sufficient.20. Design assumes manufacture in accordance with ANSI/TPI 1 Quality Criteria.Failure to Follow Could Cause PropertyDamage or Personal Injury (Drawings not to scale)© 2012 MiTek® All Rights ReservedMiTek Engineering Reference Sheet: MII-7473 rev. 10/03/2015edge of truss.from outside"16/1-0ICC-ES Reports:ESR-1311, ESR-1352, ESR1988ER-3907, ESR-2362, ESR-1397, ESR-3282JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISEAROUND THE TRUSS STARTING AT THE JOINT FARTHEST TOTHE LEFT.CHORDS AND WEBS ARE IDENTIFIED BY END JOINTNUMBERS/LETTERS.W 4 - 6 W3-6W3 - 7 W2-7W1-7C1-8 C5-6C6-7C7-8C4-5 C3-4C2-3C1-2TOP CHORD TOP CHORD 87654321BOTTOM CHORDSTOP CHORDSBEARING4 x 4PLATE SIZEThis symbol indicates the required direction of slots inconnector plates."16/1For 4 x 2 orientation, locateplates 0- 1"4/3PLATE LOCATION AND ORIENTATIONSymbolsNumbering SystemGeneral Safety Notes *Plate location details available in MiTek 20/20software or upon request.Industry Standards:ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction.DSB-89: Design Standard for Bracing.BCSI: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses.6-4-8WEBSTrusses are designed for wind loads in the plane of the truss unless otherwise shown.Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others.dimensions shown in ft-in-sixteenths