HomeMy WebLinkAboutA001.0SUMP w/ CHECK VALVE, VERIFY LOCATIONOPT. EJECTOR PIT AND PUMP AS REQUIRED, VERIFY LOCATIONPROVIDE SEPARATION BETWEEN WATER & SEWER LINES, PER CODE
FURNACE PER MECHANICAL PLANS WATER HEATER, PER SPECOPT. WATER SOFTENER, PER SPECRADON VENT PER CODE, VERIFY LOCATION PERIMETER DRAIN, PER SPEC
UP 7 RISERS
HANDRAIL, PER CODE
1234567 POST & BEAM PER STRUCTURAL PLANS POST & BEAM PER STRUCTURAL PLANS
12345678
\pxql;2/8
FD
OPT\PROUGH IN BATH
2/8
2/8
SOFFIT PER SPEC
ELECTRICAL PANEL (VERIFY LOCATION ON FIELD)
DEDICATED GFI \Pw/ GAS WATER HEATER OPT.
OPT. DEDICATED GFI FOR EJECTOR PUMP \P(VERIFY IN FIELD)
POST & BEAM PER STRUCTURAL PLANS
ADD RISER W/ OPT. 9'-0" POUR
DEDICATED GFI FOR SUMP PUMP (VERIFY IN FIELD)
4140 SL & EGRESS WELL #1, AS REQUIRED BY CODE\PSEE STRUCTURAL DETAILS
LEAD WALL PAST OVERDIG, TYP. (SEE STRUCTURAL)\pxql;PAD FOOTING w/ OUTDOOR FIREPLACE OPTION \A1;2'-11{\H0.75x;\S3#4;}"\A1;2'-7{\H0.75x;\S1#4;}"
\A1;20'-6{\H0.75x;\S1#2;}"\A1;1'-5{\H0.75x;\S1#2;}"\A1;2'-7{\H0.75x;\S1#2;}"
\A1;22'-8{\H0.75x;\S1#2;}"
\A1;11'-5{\H0.75x;\S1#2;}"
\A1;3'-6{\H0.75x;\S1#2;}"\A1;3'-6{\H0.75x;\S1#2;}"\A1;15'-4"
\A1;20'-9{\H0.75x;\S1#2;}"
\A1;11"
\A1;14'-1{\H0.75x;\S1#2;}"
\A1;12'-0"\A1;1'-0"\A1;9'-1{\H0.75x;\S1#2;}"
\A1;48'-7" - OVERALL
\A1;31'-9{\H0.75x;\S1#2;}"
\A1;16'-9{\H0.75x;\S1#2;}"
\A1;14'-0"
\A1;17'-6"
\A1;12'-0"
\A1;2'-0"
\A1;30'-6{\H0.75x;\S1#2;}"
\A1;6'-4"
\A1;11'-2"
\A1;11'-0{\H0.75x;\S1#2;}"
\A1;6'-9"
\A1;1'-0"
\A1;11"
LEAD WALL PAST OVERDIG, FIELD VERIFY LOCATION\P(TYP.)
\A1;33'-7{\H0.75x;\S1#2;}"
\A1;29'-7{\H0.75x;\S1#2;}"
\A1;48'-7" - OVERALL
\A1;20'-1"
\A1;9'-6{\H0.75x;\S1#2;}"
\A1;64'-7" - OVERALL \A1;30'-11{\H0.75x;\S1#2;}"
\A1;64'-7" - OVERALL
\A1;11'-11{\H0.75x;\S1#2;}"
\A1;1'-9"\A1;2'-6{\H0.75x;\S1#2;}"
\A1;11'-8"
\A1;8'-3"\A1;2'-2"\A1;16'-3"
LEAD WALL PAST OVERDIG, FIELD VERIFY LOCATION\P(TYP.)
\A1;10'-8"
\A1;8'-0"
\A1;1'-9{\H0.75x;\S1#2;}"
\A1;4'-5"
\A1;1'-9{\H0.75x;\S1#2;}"
\A1;2'-8"\A1;1'-9{\H0.75x;\S1#2;}"\A1;10{\H0.75x;\S1#2;}"\A1;5'-0{\H0.75x;\S1#2;}"\A1;1'-9{\H0.75x;\S1#2;}"\A1;3'-3"
\A1;8'-10{\H0.75x;\S1#2;}"
\A1;1'-9{\H0.75x;\S1#2;}"
\A1;47'-7" TO CORNER
\A1;10'-6"
\A1;4'-10{\H0.75x;\S1#2;}"
\A1;13'-1{\H0.75x;\S1#2;}"
\A1;9'-3{\H0.75x;\S1#2;}"
\A1;3{\H0.75x;\S1#2;}"
2A2 B.1
1A2 B.1
1A2 B.1
2A2 B.1
3A2 B.2
4A2 B.2 4A2 B.236x60 SHOWER
OPT. GAS VALVE
GAS VALVE
CONCRETE SLABUNEXCAVATED (SEE STRUCTURAL PLANS)
3A2 B.2SLAB/UNEXCAVATED
CONCRETE SLABUNEXCAVATED (SEE STRUCTURAL PLANS)PORCHUNEXCAVATED (SEE STRUCTURAL PLANS)FINISHED BASEMENTSLAB (SEE STRUCTURAL PLANS)STORAGEHVACA0.01 FOUNDATION - BASEMENTMidwest Zone Office1900 Golf Road - Suite 300Schaumburg, Illinois 60173(c) Copyright 2017 PulteGroup, Inc.
PRODUCT MANAGERRick StarkeyVERSION RELEASEDATE:12/12/2016
PROJECT TYPESingle Family
SHEET
PLAN NAME
SPECIFICATION LEVEL
NPC CHILD NUMBER
----
Allison II
2377.300Home for * Market Home *, 6838-02400#212973 Copper Run Boulevard, Carmel, IN 46074BASEMENT FOUNDATION PLANSCALE: 1/4" = 1'-0" (HALF SCALE ON 11x17 PAPER)
09/16/19
Adam Schriner