Loading...
HomeMy WebLinkAboutA000.3ROOF SHINGLES, PER SPEC FYPON #LV12X24 OR APPROVED EQUAL \A1;7'-2{\H0.750000x;\S1#2;}"\A1;8'-1{\H0.750000x;\S1#8;}" \A1;8'-1{\H0.750000x;\S1#8;}"\A1;9'-1{\H0.750000x;\S1#8;}" \A1;8'-11{\H0.750000x;\S1#2;}" TOP OF PLATEWINDOW HEAD HGT. TOP OF FLOORTOP OF PLATEWINDOW HEAD HGT. TOP OF FLOORTOP OF FOUNDATION 8" FASCIA, PER SPEC8" FRIEZE, PER SPEC4" CORNER BOARD, PER SPECHORIZONTAL SIDING, PER SPEC BRICK SOLDIER COURSE, PER SPEC18"x60" PANEL SHUTTERS, PER SPEC BRICK SOLDIER COURSE, PER SPEC 1x3 OVER 8" RAKE BOARD, PER SPEC 4" FRIEZE, PER SPEC STONE SILL, PER SPEC STONE VENEER, PER SPEC 1214 4" FRIEZE, PER SPEC 1214 12141214 1214 1214 1214 1214 BLACKOUT WINDOW 4" TRIM BOARD, PER SPEC 6" TRIM BOARD, PER SPECFYPON BRACKET #DTLB6X6X5\POR APPROVED EQUAL6" TRIM BOARD, PER SPEC \A1;3'-6"\A1;MIN. TOP OF FOOTING STONE SILL, PER SPEC \A1;6'-8"\A1;HDR. HGT. SCALE:FRONT ELEVATION1/4" = 1'-0" 1214 2030 FX 8:12 \A1;2'-6" 8:1212:12 8:12 12:1212:1212:12 8:12 3:12 2650 FX \A1;3'-1"\A1;3'-1" \A1;8'-1{\H0.75x;\S1#8;}"\A1;PLATE HEIGHT \A1;1'-0" \A1;7'-8{\H0.75x;\S3#8;}"\A1;7'-4{\H0.75x;\S3#4;}" \A1;4'-0"\A1;4'-0"\pxql;PROVIDE ADEQUATE OPENING FOR AIR MOVEMENT BETWEEN ATTIC SPACES TO SUPPORT REQUIRED VENTILATION, TYP. \pxi-4,l4,ql,t3;POT VENT\A1;13'-0" \A1;12'-0" \A1;4'-0" \A1;5'-0" \A1;5'-8{\H0.750000x;\S1#2;}" \A1;2'-7" \A1;7'-5" \A1;1'-3"\A1;2'-7" \A1;6'-10{\H0.750000x;\S1#4;}" \A1;32'-8" \A1;3'-6"\A1;2'-5" \A1;3'-6"\A1;3'-6" SCALE:ROOF PLAN1/8" = 1'-0" "A"2986ROOF AREA:SQ. FT. "B"28ROOF AREA:SQ. FT. 14:12 14:12 14:12 14:1214:12 14:1214:1214:12 14:12 14:12 14:1214:1214:1214:12 8:12 8:12 8:128:12 8:12 14:128:12 8:12 8:12 3:12 3:12 8:1214:12 TOP OF PLATEWINDOW HEAD HGT. TOP OF FLOORTOP OF PLATEWINDOW HEAD HGT. TOP OF FLOORTOP OF FOUNDATION TOP OF FOOTING \A1;7'-2{\H0.750000x;\S1#2;}"\A1;8'-1{\H0.750000x;\S1#8;}" \A1;8'-1{\H0.750000x;\S1#8;}"\A1;9'-1{\H0.750000x;\S1#8;}" \A1;8'-11{\H0.750000x;\S1#2;}"\A1;3'-6"\A1;MIN. ROOF SHINGLES, PER SPEC 8" FASCIA, PER SPEC4" FRIEZE, PER SPEC BRICK SOLDIER COURSE, PER SPECSTONE VENEER, PER SPEC BLACKOUT WINDOW MASONRY WRAP, PER SPEC4" CORNER BOARD, PER SPEC 4" TRIM BOARD (TYP.), PER SPEC 123 128128 1214 128 2030 FX2030 FX 1x3 OVER 6" RAKE BOARD, PER SPEC4" FRIEZE, PER SPEC 10" FRIEZE, PER SPEC 4" TRIM BOARD, PER SPEC \A1;15'-6{\H0.750000x;\S1#8;}" 128 128 128 SCALE:LEFT ELEVATION1/8" = 1'-0" \A1;7'-1{\H0.750000x;\S1#8;}"\A1;HEAD HT. \A1;3'-6" TOP OF PLATE ROOF SHINGLES, PER SPEC WINDOW HEAD HGT. TOP OF FLOORTOP OF PLATEWINDOW HEAD HGT. TOP OF FLOORTOP OF FOUNDATION TOP OF FOOTING \A1;7'-2{\H0.750000x;\S1#2;}"\A1;8'-1{\H0.750000x;\S1#8;}" \A1;8'-1{\H0.750000x;\S1#8;}"\A1;9'-1{\H0.750000x;\S1#8;}" \A1;8'-11{\H0.750000x;\S1#2;}" 8" FASCIA, PER SPEC10" FRIEZE, PER SPEC 4" CORNER BOARD, PER SPEC4" TRIM BOARD (TYP.), PER SPECHORIZONTAL SIDING, PER SPECMASONRY WRAP, PER SPECSTONE VENEER, PER SPECBRICK SOLDIER COURSE, PER SPEC 4" FRIEZE, PER SPEC10" FRIEZE, PER SPEC \A1;15'-6{\H0.750000x;\S1#4;}" TOP OF PLATE1x3 OVER 8" RAKE BOARD, PER SPEC4" FRIEZE, PER SPEC 128128 128 128 128128 \A1;3'-6"\PMIN. SCALE:RIGHT ELEVATION1/8" = 1'-0" \A1;3'-6" TOP OF PLATEWINDOW HEAD HGT. TOP OF FLOORTOP OF PLATEWINDOW HEAD HGT. TOP OF FLOORTOP OF FOUNDATION TOP OF FOOTING \A1;7'-2{\H0.750000x;\S1#2;}"\A1;8'-1{\H0.750000x;\S1#8;}" \A1;8'-1{\H0.750000x;\S1#8;}"\A1;9'-1{\H0.750000x;\S1#8;}" \A1;8'-11{\H0.750000x;\S1#2;}" MASONRY WRAP, PER SPEC4" CORNER BOARD, PER SPEC ROOF SHINGLES, PER SPEC 8" FASCIA, PER SPECHARDIE PANEL (SMOOTH), PER SPEC6" TRIM BOARD (TYP.), PER SPEC 12141214 1214 8" TRIM BOARD, PER SPEC 4" TRIM BOARD, PER SPEC 6" TRIM BOARD (TYP.), PER SPEC 1214 SCALE:REAR ELEVATION1/8" = 1'-0" \A1;15'-6{\H0.750000x;\S1#8;}"\A1;PLATE HT. ELEVATION EC01 ATTIC VENT SCHEDULE VENTILATION REQUIRED AND SUPPLIED IS BASED ON POT VENT VALUES AND RIDGE VENT VALUES SHOWN IN TABLE ABOVE ** CONTRACTORS INSTALLING VENTILATION ARE RESPONSIBLE FOR VERIFYING THAT VENTS USED WILL SUPPY VENTILATION TO MEET CODE REQUIREMENTS * SCHEDULE HAS BEEN CALCULATED ASSUMING EAVE VENTILATION AT 50-60% OF TOTAL AND RIDGE AT 40-50% OF TOTAL REQUIRED VENTILATION ROOF AREA "A"SQ FTG 2986 AT / NEAR RIDGE AT / NEAR EAVE VENT TYPE SQ. FT. REQUIRED RANGE SQ. FT. SUPPLIED PERCENT OF TOTAL SUPPLIED POT LARGE (SQ. IN. EACH) POT SMALL (SQ. IN. EACH) RIDGE VENT (SQ. IN. PER LF) EAVE VENT (SQ. IN. EACH) CONT. VENT (SQ. IN. PER LF) 61.00 40.00 18.00 28.00 10.00 HIGH - POT VENTS ONLY 3.98 4.98 4.66 46.89 11 0 AT EAVE 5.97 4.98 5.28 53.11 0 76.00 TOTAL (MIN)9.95 9.95 9.94 100.00 3 HIGH - RIDGE VENT 3.98 4.98 5.00 50.00 0 0 40.00 AT EAVE 5.97 4.98 5.00 50.00 0 72.00 TOTAL (MIN)9.95 9.95 10.00 100.00 ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE ELEVATION EC01 ATTIC VENT SCHEDULE VENTILATION REQUIRED AND SUPPLIED IS BASED ON POT VENT VALUES AND RIDGE VENT VALUES SHOWN IN TABLE ABOVE ** CONTRACTORS INSTALLING VENTILATION ARE RESPONSIBLE FOR VERIFYING THAT VENTS USED WILL SUPPY VENTILATION TO MEET CODE REQUIREMENTS * SCHEDULE HAS BEEN CALCULATED ASSUMING EAVE VENTILATION AT 50-60% OF TOTAL AND RIDGE AT 40-50% OF TOTAL REQUIRED VENTILATION ROOF AREA "A"SQ FTG 28 AT / NEAR RIDGE AT / NEAR EAVE VENT TYPE SQ. FT. REQUIRED RANGE SQ. FT. SUPPLIED PERCENT OF TOTAL SUPPLIED POT LARGE (SQ. IN. EACH) POT SMALL (SQ. IN. EACH) RIDGE VENT (SQ. IN. PER LF) EAVE VENT (SQ. IN. EACH) CONT. VENT (SQ. IN. PER LF) 61.00 40.00 18.00 28.00 10.00 HIGH - POT VENTS ONLY 0.04 0.05 0.28 80.00 0 1 AT EAVE 0.06 0.05 0.07 20.00 0 1.00 TOTAL (MIN)0.09 0.09 0.35 100.00 3 HIGH - RIDGE VENT 0.04 0.05 0.13 64.29 0 0 1.00 AT EAVE 0.06 0.05 0.07 35.71 0 1.00 TOTAL (MIN)0.09 0.09 0.19 100.00 ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE PLOTTED: August 27, 2019 / Annie Lee / 2975-IN-NAPLES-EC01.DWG A3-EC01 1FB.1Euro Country2 Car Side EntryFront, Side and Rear Elevations, Roof Plan and Ventilation Schedule1901 North Roselle Road, Suite 1000Schaumburg, Illinois 60195Pulte Central ZonePLAN NAME SHEET PRODUCTION MANAGER DATE / DESCRIPTION NPC PLAN NUMBERLAWSON PLAN ID GARAGE HANDING REV # NOTE: SCALES NOTED ON DRAWINGS RELATE TO FULL SIZE PLOTS ON 22x34 SHEETS - 11x17 SHEETS REPRESENT 1/2 SCALE PLOTS INITIAL RELEASE DATE:CURRENT RELEASE DATE: (c) Copyright Pulte Home Corporation - 2019 Suzette Schuette3/30/2015 GARAGE RIGHT 2975-Naples 1815.0000 LOT 03 08/23/2019 09/16/19 Adam Schriner