HomeMy WebLinkAboutLEGACY RIDGE 92 - (AS DESIGNED)IECC 2009 Performance Compliance Property 6825 PULASKI CT CARMEL, IN 46033 Model: 3500 Community: LEGACY RIDGE 92 (AS DESIGNED) LEGACY RIDGE 92 Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES Design Heating Cooling Water Heating SubTotal - Used to determine compliance Lights &Appliances Onsite generation Total Inspection Status Results are projected Annual Energy Cost IECC 2009 Performance $1,728 $272 $398 $2,398 $932 $0 $3,330 Requirements 405.3 Performanoe-based compliance passes by 7.7% R402.4.1 .2 Air Leakage Testing 402.5 Area -weighted average fenestration SHGC 402.5 Area -weighted average fenestration U-Factor 403.2.2 Duct Testing Mandatory Checklist Mandatory code requirements that are not checked by Ekotrope must be met. R4052 Duct Insulation C-M, Energy Solutions As Designed $1,560 $256 $398 $2,214 $932 $0 $3,146 Air sealing is 5.00 ACH at 50 Pa. It must not exceed 7.00 ACH at 50 Pa. Design exceeds requirements for IECC 2009 Performance compliance by 7.7%. As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify thatthe building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and thatthe mandatary provisions of the IECC have been installed to meet or exceed the intentof the IECC or will be verified as such by another party. Name: Matthew Timmons Organization: TSI Energy Solutions Signature: Date: 8121/19 at 2:47 PM Ekotrope RATER -Version 3.1.0.2236 IECC 2009 Performance compliance results calculated using Ekotrope RATER's energy and code complianceaIgo rithm. Ekotrope RATER is a RESNET Accredited H ERS Rating Tool. All results are based on data entered by Ekotrope users. Ekotropedisclaims all liabilityforthe information shown on this report. 6825 PULASKI CT CARMEL, IN 46033 Builder: LENNAR HOMES Ceiling Attic, R-38 Above Grade Walls R-16 Foundation Walls R-11 Framed Floor R-38 Slab R-0.0 Perimeter, R-0.0 Under Infiltration 5 ACH50 Window U-Value: 0.31, SHGC: 0.32 Building Features Duct Supply R-30.0, Return R-20.0 Duct Leakage to Outside 268 CFM25 (5.961100 s.f.) Total Duct Leakage 384 CFM25 (Post -Construction) Heating Furnace • Natural Gas • 95.5 AFUE Cooling Air Conditioner • Electric • 13 SEER Water Heating Water Heater • Electric • 0.93 Energy Factor As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected. I certify that the building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspectedltested and that the mandatory provisions of the IECC have been installed to meet or exceed the intentof the IECC or will be verified as such by another party. Name: Matthew Timmons Organization: TSI Energy Solutions Signature: Date: 8l21119 at 2:47 PM Ekotrope RATER - Version 3.1.0.2236 20091ECC compliance resuits calculated using Ekotrope RATEWs energy and code compliance algorithm- Ekotrope RATER is a RESNET Accredited HERS Rating Tool. All results are based on data erd.ered by Ekotrope users. Ekotrope disclaims all liability for the information shown on this report. Energy Code Inspection Checklist Property organization 6825 PULASKI CT TSI Energy Solutions CARMEL, IN 46033 Matthew Timmons Model: 3500 Community: LEGACY RIDGE 92 Builder LENNAR HOMES (AS DESIGNED) LEGACY RIDGE 92 General Building Information Conditioned Area (sq ft) 5,348 Conditioned Volume (cubic ft) 47,840 Insulated Shell Area (sq ft) 9,419 Inspection Status Results are projected C-M, Energy Solutions The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy features will change in the field from what has been modeled. The inspection process should identify any changes and ensure that the home continues to meet the applicable energy code. Slab Name: BSMT(1,712 s.f., 174 ft. exterior perimeter) R-0 perimeter insulation, R-0 under slab insulation. Framed Floor ] Name: OVER GARAGE (402 s.f.) R-0 continuous insulation, R-38 cavity insulation Insulation Grade: I ] Name: OVER AMBIENT (14 s.f.) R-0 continuous insulation, R-38 cavity insulation Insulation Grade: I Foundation Wall Name: CONDIAMB (Exterior Perimeter [ft]: 131, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 8) R: 11.00 Feet from top of wall to top of insulation: 0, Feet from top of wall to bottom of insulation: 4 Name: CONDIGAR (Exterior Perimeter [ft]: 43, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 8) R: 11.00 Feet from top of wall to top of insulation: 0, Feet from top of wall to bottom of insulation: 4 Above Grade Wall Name: CONDIAMB (2,367 s.f.) R-3 continuous insulation, R-13 cavity insulation Insulation Grade: I Energy Code Inspection Checklist Property organization 6825 PULASKI CT TSI Energy Solutions CARMEL, IN 46033 Matthew Timmons Model: 3500 Community: LEGACY RIDGE 92 Builder LENNAR HOMES (AS DESIGNED) LEGACY RIDGE 92 El Name: CONDIAMB 2X6 (270 s.f.) R-3 continuous insulation, R-19 cavity insulation Insulation Grade: I El Name: CONDIGAR (387 s.f.) R-0 continuous insulation, R-13 cavity insulation Insulation Grade: I El Name: CONDIATTIC (206 s.f.) R-3 continuous insulation, R-13 cavity insulation Insulation Grade: I Rim Joist Name: CONDIAMB (270 s.f.) R: 13.575 Name: CONDIGAR (43 s.f.) R: 10.876 El Name: CONDIATTIC (54 s.f.) R: 10.876 Roof Name: SECOND (2,128 s.f.) R-27.55 continuous insulation, R-10.15 cavity insulation Insulation Grade: I Opaque Door El Name: FRONT (20 s.f.) U: 0.182 El Name: GARAGE (18 s.f.) U: 0.182 Inspection Status Results are projected C-M, Energy Solutions Glazing 2 Energy Code Inspection Checklist 7'SI Energy Solutions Property Organization Inspection Status 6825 PULASKI CT TSI Energy Solutions Results are projected CARMEL, IN 46033 Matthew Timmons Model: 3500 Community: LEGACY RIDGE 92 Builder LENNAR HOMES (AS DESIGNED) LEGACY RIDGE 92 E] Name: FRONT (132 s.f.), U: 0.310, SHGC: 0.29, Orientation: EAST Name: BACK (174 s.f.), U: 0.310, SHGC: 0.32, Orientation: WEST L] Name: BACK 2X6 (77 s.f.), U: 0.310, SHGC: 0.32, Orientation: WEST El Name: BACK 2X6 GD (18 s.f.), U: 0.290, SHGC: 0.33, Orientation: WEST L] Name: RIGHT SIDE (83 s.f.), U: 0.310, SHGC: 0.32, Orientation: NORTH Ll Name: RIGHT SIDE BSMT (16 s.f.), U: 0.310, SHGC: 0.32, Orientation: NORTH E] Name: LEFT SIDE (59 s.f.), U: 0.310, SHGC: 0.32, Orientation: SOUTH Ll Name: LEFT SIDE BSMT (16 s.f.), U: 0.310, SHGC: 0.32, Orientation: SOUTH Skylight None Present Mechanical Ventilation None Present Mechanical Equipment El Fuel -fired air distribution (1) • Natural Gas • 100% Heating Load @ 95.5 AFUE E] Air conditioner (2) • Electric • 100% Cooling Load @ 13 SEER Water Heating (3) • Electric • 100% Hot Water Load @ 0.93 Energy Factor Air Leakage Control Test Status: Blower -door tested 3 House is air -sealed as to achieve 3,987 CFM50 (5.00 ACH50) or less at final blower -door test. Energy Code Inspection Checklist Property 6825 PULASKI CT CARMEL, IN 46033 Model: 3500 Community: LEGACY RIDGE 92 (AS DESIGNED) LEGACY RIDGE 92 Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES Infiltration Requirements for IECC in Climate Zone 5 Inspection Status Results are projected 2009 IECC Infiltration limit for the design home is 7 ACH50. 2012 IECC Infiltration limit for the design home is 3 ACH50. 2015 IECC Infiltration limit for the design home is 3 ACH50. Duct Leakage Duct System 1 NOT entirely within conditioned space, testing required Leakage to Outside specified as: 288 CFM25 (5.961 100 s.f.) Total Leakage specified as: 384 CFM25 (Post -Construction) Duct Leakage Code Requirements for IECC 2009 IECC: Postconstruction Leakage Test: Duct Leakage to Outdoors <= 8 CFM25 1100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 6 CFM251100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 4 CFM25 J 100 sq ft CFA. 2012 IECC and 2015 IECC Prescriptive Path: Postconstruction Leakage Test: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 4 CFM251100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 3 CFM25 1100 sq ft CFA. 2015 Performance Path (Cost Compliance): CTSI Energy Solutions Leakage testing is required UNLESS all ducts and air handlers are located entirely within the thermal envelope. There is no pass/fail threshold for duct leakage on the performance path. Project Notes 4 Building Summary Properly Organization Inspection Status 6825 PULASKI CT TSI Energy Solutions Results are projected CARMEL. IN 46033 Matthew Timmons Model: 3500 Cornmunity: LEGACY RIDGE 92 Builder LENNAR HOMES [AS DESIGNED] LEGACY RIDGE 92 General Building Information Number Of Bedrooms 4 Number Of Floors 2 Conditioned Floor Area [sq. ft.] 5,348 Unconditioned, attached garage? Yes Conditioned Volume [cu. ft.1 47,840 Total Units in Building 1 Residence Type Single family detached Floor Number - Model 3500 Community LEGACY RIDGE 92 Climate Zone 5A Foundation Wall Name CONDIAMB CO N DIGAR R-11 Draped, 4ft 1 8 131 R-11 Draped.4ft 1 8 43 Foundation Wall Library List Name Feet From Wall Top To Feet From Wall Top To Continuous Insulation Continuous Insulation Top Bottom R-11 Draped. 4ft ❑ 4 Is Fully Insulated Continuous R-value No NIA C-M, Energy Solutions Exposed Exterior Conditioned Space Exposed Exterior Conditioned Space Cavity R-value Effective Insulation R- value NIA 11.00 Slab I Name Library Type Perimeter Floor Grade Carpet R Exposed Surface Area Location Masonry Area Enclosing BSMT Uninsulated 174 Below Grade 0 ❑ 1,712.0 1t2 Exposed Exterior Conditioned Space Slab Library List Name Wall Construction Slab Completer Underslab Perimeter Perimeter Thermal Break Effective R-value Type Insulated . Insulation Width [ffJ Insulation Depth [ftJ Insulation R Value Uninsulated Wood Frame 1 Other No 0 ❑ ❑ No 11.0❑ 1 1 Building Summary Properly 6825 PULASKI CT CARMEL. IN 46033 Model: 3500 Community: LEGACYRIDGE 92 [AS DESIGNED] LEGACY RIDGE 92 ramed Floor Name Library Type OVER AMBIENT R-38, GR1 OVER GARAGE R-38, GR1 Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES Inspection Status Results are projected C-M, Energy Solutions iet R Floor Grade Surface Area Location 1.23 Above Grade 14.0 ftY Exposed Exterior 1.23 Above Grade 402.0 T Unconditioned, attached garage Framed Floor Library List Name Effective R-value R-38. GR1 33.825 Rim Joist Name Library Type Surface Area Location CONDIAMB Exposed Exterior G1 R-13, R-3.0 270.0 HY CONDIATTIC G1 R-13, OSB 54.0 f[s Attic CONDIGAR Unconditioned. attached garage G1 R-13, OSB 43.0 f[s Rim Joist Library List Name Effective Insulation R-value k G1 R-13, OSB 10.876 G1 R-13, R-3.0 13.575 CONDIAMB CON DIAMB 2X6 Library Type G1 R-13 BATT. R 3.0 Surface Color Medium Surface Area Location 2,367.0 IV Exposed Exterior G1 R-19, R-3.0 2X6 Medium 270.0 ft' Exposed Exterior 4 Building Summary Properly Organization Inspection Status Energy Solutions C-M 6825 PULASKI CT TSI Energy Solutions Results are projected CARMEL. IN 46033 Mathew Timmons Model: 3500 Community: LEGACY RIDGE 92 Builder LENNAR HOMES [AS DESIGNED] LEGACY RIDGE 92 Name Library Type Surface Color Surface Area Location CONDIATTIC G1 R-13 BATT. R-3.0 Medium 2060.ft2 Attic CONDIGAR G1 R-13 Gar Walls Medium 387.0 P[' Unconditioned, attached garage Wall Library List Name Effective R-value G1 R-13 BATT, R-3.0 15-12 G1 R-13 Gar Walls 11.141 GI R-19, R-3.0 2X6 20217 Glazing Name Library Type Wal} Assignment Foundation Wall Overhang Depth Overhang Ft To Overhang Ft To Orientation Surface Area Assignment Top Bottom BACK U-.31, SHGC-.32 CONDIAMS ❑ 0 0 West 174.0 ft2 BACK 2X6 U-.31, SHGG.32 CON DIAMB 2X6 ❑ 0 0 West 77.0 fts BACK2X6 GD U-29, SHGG.33 CON DIAMB 2X6 ❑ 0 0 West 18.0 fts FRONT U-.31, SHGC-29 COND+AMB ❑ 0 0 East 132.0 ft2 LEFT SIDE U-.31, SHGG.32 COND+AMB ❑ 0 0 South 59.0 fts LEFT SIDE BSMT U-.31, SHGG.32 CONDIAMB ❑ 0 0 South 16.0 fr' RIGHT SIDE U-.31, SHGG.32 COND+AMB 0 0 0 North 83.0 fts RIGHT SIDE BSMT U-.31, SHGG.32 CONDIAMB 0 0 0 North 16.0 fF Building Summary Properly 6825 PULASKI CT CARMEL. IN 46033 Model: 3500 Cornmunity: LEGACY RIDGE 92 [AS DESIGNED] LEGACY RIDGE 92 ng Library List Name U-.29, SHGC-.33 U-.31, SHGC-29 U-.31, SHGC-.32 Rill Skylight Skylight Library List Opaque Door Name FRONT Steel Door CONDfAMB GARAGE Steel Door COND+GAR Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES Shgc Inspection Status Results are projected 0.33 0290 029 0.310 0.32 0.310 None Present None Present Opaque Door Library List W Name Effective J-factor -:�Cr 0.182 C-M, Energy Solutions 0.9 0.75 Medium 20.0 f:2 Exposed Exterior 0.9 0.75 Medium 18.0 ft2 Exposed Exterior 4 Building Summary Properly 6825 PULASKI CT CARMEL. IN 46033 Model: 3500 Cornmunity: LEGACY RIDGE 92 [AS DESIGNED] LEGACY RIDGE 92 FRoof Insulation Name Library Type SECOND R-38BIawn, GR1 Organization TSI Energy Solutions Mathew Timmons Builder LENNAR HOMES Inspection status Results are projected C-M, Energy Solutions 2,128 No Medium 2,128.0 ff Attic Roof Insulation Library List Name Has Radiant Barrier IR-38 Blown, GR1 No Whole House Infiltration Infiltration Measurement Type 5ACH at 50 Pa Blower -door tested Mechanical Ventilation None Present Effective R-value 38.268 Shelter Class 4 Lighting % Interior Fluorescent % Interior LED Lighting °% Exterior Fluorescent °! Exterior LED Lighting % Garage Fluorescent % Garage LED Lighting Lighting Lighting Lighting 100 0 100 0 10C Onsite Generation None Present �J Building Summary Properly C-MEnergy Solutions Organization Inspection Status 6825 PULASKI CT TSI Energy Solutions Results are projected CARMEL. IN 46033 Matthew Timmons Model: 3500 Cornmunity: LEGACY RIDGE 92 Builder LENNAR HOMES [AS DESIGNED] LEGACY RIDGE 92 nsite Generation Library List None Present Solar Generation None Present Solar Generation Library List None Present s � Conditioning Equipment Name Library Type Heating Percent Load Cooling Percent Load Air conditioner (2) 4AC'42P Fuel -fired air distribution (1) Water Heating (3) 915SA48080517 RE350* Equipment Type: 4AC*42P 0% 100 % 0% 100 % 0% 0% Fuel Type Electric Distribution Type Forced Air Motor Type PSG (Single Speed) Cooling Efficiency 13 SEER Cooling Capacity [kBtulh] 40 It Equipment Type: 9155A48080517 Fuel Type Natural Gas Distribution Type Forced Air Motor Type PSC {Single Speed} Heating Efficiency 95.5 AFUE Heating Capacity [kBtulh] 78 Use default EAE No EAE [kWh] 946 Hot Water Percent Load Location ❑% Conditioned Space ❑% Conditioned Space 100% Conditioned Space Building Summary Properly 6825 PULASKI CT CARMEL. IN 46033 Model: 3500 Community: LEGACY RIDGE 92 [AS DESIGNED] LEGACY RIDGE 92 Equipment Type: Fuel Type Distribution Type Hot Water Efficiency Tank Capacity (gal-) Hot Water Capacity [kBtulh] Recovery Efficiency RE35 Distribution System Distribution Type Heating Equipment Cooling Equipment Sq. Feet Served # Return Grilles Supply Duct R Value Return Duct R Value Supply Duct Area [ftJ Return Duct Area [ft�] Lea kageto Outdoors Total Leakage Total Leakage Duct Test Conditions Use Default Flow Rate Duct 1 Duct Location Percent Supply Area Percent Return Area Duct 2 Duct Location Percent Supply Area Percent Return Area Duct 3 Duct Location Percent Supply Area Percent Return Area Duct 4 Duct Location Percent Supply Area Percent Return Area Duct 5 Duct Location Percent Supply Area Percent Return Area Duct 6 Duct Location Percent Supply Area Percent Return Area Ceiling Fan Has Ceiling Fan Cfm Per Watt Organization Inspection Status TSI Energy Solutions Results are projected Mathew Timmons Builder LENNAR HOMES Electric Hydronic Delivery 0.93 Energy Factor 50 15.4 0.98 Forced Air FueLf red air distribution (1 } Air conditioner (2) 4836 4 30 20 1305.72 9672 288 CFM25 (5.961 100 s.f.) 384 CFM25 Post -Construction Yes Conditioned Space 50 70 Attic (well vented, under insulation) 50 30 Conditioned Space Conditioned Space 0 Conditioned Space Conditioned Space 0 0 No 100 C-M, Energy Solutions 7 Building Summary Properly 6825 PULASKI CT CARMEL. IN 46033 Model: 3500 Cornmunity: LEGACYRIDGE 92 [AS DESIGNED] LEGACY RIDGE 92 Water Fixture Type Use Default Hot Water Pipe Length Hot Water Pipe Length [ft] At Least R3 Pipe Insulation? Hot Water Recirculation System? Recirculation System Pipe Loop Length [ft] Drain Water Heat Recovery? Clothes Dryer Fuel Type Cef Field Utilization Clothes Washer Label Energy Rating Electric Rate Annual Gas Cost Gas Rate Capacity I met Appliances and Controls Programmable thermostat? Dishwasher Size Dishwasher Efficiency Range/Oven Fuel Convection Oven? Induction Range? Refrigerator Consumption Organization Inspection Status TSI Energy Solutions Results are projected Mathew Timmons Builder LENNAR HOMES Standard No 100 No No 30 No Electric 2.617 Timer Controls 704 kWh/Year $0.081kWh $23.00 $0.581Therm 2.874 ❑.331 Yes Standard 270 kWh Electric No No 709 kWh/Year C-M, Energy Solutions