HomeMy WebLinkAboutSHW 018 - Energy Certificate2606 LACEWOOD CT
CARMEL, IN 46074
Builder: PULTE HOMES
Ceiling Attic, R-38
Above Grade Walls R-15
Foundation Walls R-11
Framed Floor N/A
�4 17:41111' F�M18,0l1lf1'Ti i[ I
Infiltration 5 ACH50
Window U-Value: 0.31, SHGC: 0.28
Building Features
Duct Supply R-30.0, Return R-30.0
Duct Leakage to Outside 300 CFM25 (5.931100 s.f.)
Total Duct Leakage 400 CFM25 (Post -Construction)
Heating Furnace • Natural Gas • 93 AFUE
Cooling Air Conditioner • Electric • 13 SEER
Water Heating Water Heater • Electric • 0.93 Energy Factor
As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of
Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. It rating is Projected, I certlfy that the building design described herein is consistent with the
building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspectedltested and
that the mandatory provisions of the I ECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party.
Name
Michael Hill
Organization: TSI Energy Solutions
Signature:
Date:
8/27119 at 1:52 PM
Ekotrope RATER - Version 3.2.2.2239
20091ECC compliance results calculated using Ekotrope RATER's energy and code compliance algorithm.
Ekotrope RATER is a RESNETAccredited HERS Rating Tool. All results are based on data entered by Ekotrope users.
Ekotrope disclaims all liability for the information shown on this report.