HomeMy WebLinkAboutA000.3SCALE:FRONT ELEVATION1/4" = 1'-0"-
\A1;1'-1"
1012
1012
3:12
\A1;4'-6" A.F.F.
\A1;3'-2" TYP.
SHINGLES PERSUB. SPECS.
STONE PER SPECS
4" SILL
9" CROSSHEAD
SIDING PER SPECS
SHINGLES PERSUB. SPECS.
9" CROSSHEAD (TYP.)
SIDING PER SPECS16x36 LOUV. VENT
4" TRIM SURROUND ON DOOR10" SQ. HALF COLUMN(SEE PORCH DETAIL)
9" CROSSHEAD4" TRIM BOARD4" SILL
4" TRIM SILL16x36 LOUV. VENTOPT. STANDING SEAM METAL ROOF W/ SEAMS @ 18" O.C.
SHAKE SIDING PER SPECS9" CROSSHEAD OVER DOOR
4" TRIM BOARD
\A1;3'-2" TYP.
\A1;4'-7"
DORMERS TO BE CENTERED WITH ARCHES BELOW.\PSEE DETAIL W/ET.3
\A1;EQUAL \A1;EQUAL
10 1210 12
6" CORNER BOARD (TYP.)4" TRIM
2830 2830SHINGLES PER SUB SPECS.FIXED FIXED
\A1;17'-2"\A1;3'-4"\A1;6'-8"\A1;3'-4"
12
SHINGLES PER SUB SPECS.\A1;8'-1{\H0.75x;\S1#8;}"\A1;7'-2{\H0.75x;\S7#8;}"
ROOF W/\POPT. LOFT
\A1;9'-1{\H0.75x;\S1#8;}"\A1;OPT. 10'-1{\H0.7x;\S1#8;}" \A1;8'-2{\H0.75x;\S7#8;}"\A1;9'-2{\H0.7x;\S7#8;}" @ OPT. 10' PL.
WINDOW HEIGHT
1st FLR LINE
PLATE HEIGHT
SECOND FLOOR PLATE (OPT. LOFT)WINDOW HDR. HGT.
TOP OF FOUNDATION
SCALE:REAR ELEVATION1/8" = 1'-0"-
OPT. BRICK HEIGHT
SCALE:LEFT ELEVATION1/8" = 1'-0"-
OPT. DOOR\PPER PLAN
\A1;8'-4{\H0.75x;\S3#8;}"\A1;HDR. HGT. @ 4010 OPT. BRICK HEIGHT
127 127
SCALE:RIGHT ELEVATION1/8" = 1'-0"-
WINDOW HEIGHT
1st FLR LINE
CEILING HEIGHT
4" CORNER BOARD (TYP. ON SIDES AND REAR)
\A1;1'-1"
SIDING PER SPECS
512
\A1;2'-0"
6" CORNER BD.ON FRONT ELEV. && REAR ELEV.
512
OPT. BRICK HEIGHTTOP OF FND
OPT. WINDOWS\PPER PLAN
127ROOF W/\POPT. LOFT 127SECOND FLOOR PLATE (OPT. LOFT)
\A1;8'-1{\H0.75x;\S1#8;}"\A1;7'-2{\H0.75x;\S7#8;}"
WINDOW HDR. HGT.
\A1;9'-1{\H0.75x;\S1#8;}"\A1;OPT. 10'-1{\H0.7x;\S1#8;}" \A1;8'-2{\H0.75x;\S7#8;}"\A1;9'-2{\H0.7x;\S7#8;}" @ OPT. 10' PL.
SCALE:ROOF PLAN1/8" = 1'-0"-
ROOF AREA"A"3029 SQ. FT.
OPT. GUTTER AND DOWNSPOUTS\A1;1'-0"\PTYP.9:129:12
9:129:12
3:12
9:129:129:129:12
5:12
OPT. POT VENTS
\A1;32'-0"
5:12
\A1;8'-0"
OPT 7:12
OPT 7:12
ELEVATION CR2H
ATTIC VENT SCHEDULE
VENTILATION REQUIRED AND SUPPLIED IS BASED ON POT VENT VALUES AND RIDGE VENT VALUES SHOWN IN TABLE ABOVE
** CONTRACTORS INSTALLING VENTILATION ARE RESPONSIBLE FOR VERIFYING THAT VENTS USED WILL SUPPY VENTILATION TO MEET CODE REQUIREMENTS
* SCHEDULE HAS BEEN CALCULATED ASSUMING EAVE VENTILATION AT 50-60% OF TOTAL AND RIDGE AT 40-50% OF TOTAL REQUIRED VENTILATION
ROOF AREA "A"SQ FTG 3029 AT / NEAR RIDGE AT / NEAR EAVE
VENT TYPE
SQ. FT.
REQUIRED
RANGE
SQ. FT.
SUPPLIED
PERCENT
OF TOTAL
SUPPLIED
POT LARGE
(SQ. IN. EACH)
POT SMALL
(SQ. IN. EACH)
RIDGE VENT
(SQ. IN. PER LF)
EAVE VENT
(SQ. IN. EACH)
CONT. VENT
(SQ. IN. PER LF)
61.00 40.00 18.00 28.00 10.00
HIGH - POT
VENTS ONLY 4.04 5.05 5.08 49.73 12 0
AT EAVE 6.06 5.05 5.14 50.27 0 74.00
TOTAL (MIN)10.10 10.10 10.22 100.00
3
HIGH -
RIDGE VENT 4.04 5.05 5.00 49.32 0 0 40.00
AT EAVE 6.06 5.05 5.14 50.68 0 74.00
TOTAL (MIN)10.10 10.10 10.14 100.00 ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE
SCALE 1/4" = 1'-0"PORCH ELEVATIONS
LEFT PORCH FRONT PORCH RIGHT PORCH2" CORNER BOARD (TYP)SIDING PER COMM. SPECS (TYP)
\A1;3'-8{\H0.75x;\S1#2;}"
\A1;2'-5"
\A1;4"\A1;4"
\A1;3'-4"
DORMER DETAIL
9" CROSSHEADTRIM BOARD AROUND WINDOW 1900 Golf Road, Suite 300Schaumburg, Illinois 60173Midwest Zone Office...........................
PLAN NAME
SHEET
PRODUCTION MANAGER
DATE / DESCRIPTION
NPC PLAN NUMBERLAWSON PLAN ID
GARAGE HANDING
REV #
NOTE: SCALES NOTED ON DRAWINGS RELATE TO FULL SIZE PLOTS ON 22x34 SHEETS - 11x17 SHEETS REPRESENT 1/2 SCALE PLOTS
INITIAL RELEASE DATE:CURRENT RELEASE DATE:
(c) Copyright Pulte Home Corporation - 2017
RICK STARKEY06/07/2013
GARAGE LEFT
Croix
1993.301
--
08/01/2017
PLOTTED: October 6, 2017 / Mark Muurisepp / 1993-CROIX-CZ-BAS2-EL-CR2H.DWG
A3
CR2H-2FS.1Crafstman 2H - Slab2 Car Front EntryFront, Side and Rear Elevations, Roof Plan and Ventilation Schedule6:12 in shadow wood
12" overhangs 4
sides
stone wainscoting in shadow wood
09/16/19
Mike Sheeks