Loading...
HomeMy WebLinkAboutE101 - 2LEG3 3 3 3 3 3 3 3 3 3 33DN SINGLE POLE SWITCH THREE WAY SWITCH FOUR WAY SWITCH SMOKE DETECTOR TELEPHONE JACK TV/ DATA EXHAUST FAN DUPLEX OUTLET WEATHER PROOF OUTLET GROUND FAULT OUTLET 220V OUTLET RECESSED EYEBALL LIGHTEYE CEILING FIXTURE WALL MOUNT FIXTURE FLUORESCENT FIXTURE RECESSED FIXTURE TRACK FIXTURET UNDER CABINET FIXTURE EXTERIOR FLOOD LIGHT WIRE FOR PADDLE FAN WIRE FOR PADDLE FAN AND LIGHT KIT CS 34 WP GFI 220V CS CS CS CS F F F F CS PROVISION PROVISION PROVISION PROVISION GFI GFI GAR 220V DISPOSAL TO PHOTO CELL TO FLOOD LIGHTS 2-CAR GARAGE KITCHEN MUD ROOM PANTRY OFFICE DINING GREAT ROOM MASTER BEDROOM MASTER BATH W.I.C. LAUNDRY BED #2 BATH #2 POWDER FLEX ROOM FOYER LIGHT FAN LIGHT FAN LIGHT FAN LIGHT FAN GFI GFI GFI GFI 42" GFI GFI GFI GFI WP WP DN TO LIGHT BELOW VAULTED CEILING 5/12 SLOPE5/12 SLOPE IRRIGATION DEDICATED 6' - 6"8' - 6"ATTIC ACCESS FLOOR OUTLET CUSTOMER:PROJECT NAME:LOCATION:DRAWING TITLE: DRAWN BY:WedgewoodBuilding Co., LLC317.669.6300 32 First Street NECarmel, IN 46032www.wedgewoodbc.comCopyright c 2015 Wedgewood Building Co. LLC.9/5/2019 12:04:54 PM E2Spec ResidenceWindhaven PlanLot #2 -Overlook at Legacy1ST FLOOR ELEC. PLAN WBCELECTRICAL PLAN NOTES: 1. REFER TO COVER PAGE FOR SPANISH TRANSLATIONS = REFERIRSE A LA PORTADA DE LAS TRADUCCIONES AL ESPAÑOL.Rev.No. Date Description1/4" = 1'-0" 1 2 - MAIN LEVEL ELECTRICAL PLAN By Michael Evertsen at 12:10 pm, Sep 05, 2019 09/18/19 Mike Sheeks