Loading...
HomeMy WebLinkAboutA252_ElectricalSte210ELECTRICAL LEGEND iiiiiiiiiiiiiiiiiiiiiillillillillillillilliillillilillillillillillillillillillillillillillillillilliillillillillillillilliillillillillilI NOT IN CONTRACT STANDARD DUPLEX RECEPTACLE STANDARD QUAD DUPLEX RECEPTACLE STANDARD DEDICATED DUPLEX RECEPTACLE STANDARD RECEPTACLE (VOICE/DATA) OO STANDARD FLOOR RECEPTACLE (POWER) �"- STANDARD FLOOR RECEPTACLE (POWER W/ WHIP) ®--- STANDARD FLOOR RECEPTACLE (VOICE/DATA W/ WHIP) GFI DENOTES GROUND FAULT INTERRUPTER t N DENOTES ITEM FOR TENANT PROVIDED TV +pp DENOTES CENTERLINE MOUNTING HEIGHT OF OUTLET/RECEPTACLE NOTE: ELECTICAL ITEMS FOR LOCATION PURPOSES ONLY. GENERAL ELECTRICAL/DATA NOTES A. THE ELECTRICAL CONTRACTOR SHALL NOTIFY THE DESIGNER OF ANY DISCREPANCIES BETWEEN THE CONTRACT DOCUMENTS AND APPLICABLE CODES PRIOR TO CONSTRUCTION. B. ELECTRICAL CONTRACTOR TO COORDINATE ALL SPECIAL ELECTRICAL EQUIPMENT REQUIREMENTS AS INDICATED ON DRAWINGS OR AS REQUIRED BY TENANT. VERIFY ACTUAL REQUIREMENTS WITH DESIGNER PRIOR TO INSTALLATION. C. ELECTRICAL CONTRACTOR TO PROVIDE JUNCTION BOXES AND PULL STRINGS AT TELEPHONE/DATA LOCATIONS AS INDICATED ON PLANS. COMPLETE TELEPHONE/DATA SYSTEMS (MATERIAL AND LABOR) TO BE PROVIDED BY THE TENANT UNLESS OTHERWISE NOTED. D. ALL SECURITY SYSTEMS TO BE PROVIDED BY TENANT UNLESS NOTED OTHERWISE E. ELECTRICAL CONTRACTOR SHALL COORDINATE ALL ELECTRICAL AND LIGHTING REQUIREMENTS FOR MILLWORK AND CABINETRY WITH CONTRACTOR AS NECESSARY. F. ALL WALL MOUNTED OUTLETS ARE TO BE MOUNTED VERTICALLY AT 18" A.F.F. TO CENTERLINE OF OUTLET, UNLESS OTHERWISE NOTED. G. SWITCH PLATES, MONUMENTS, AND ELECTRICAL COVER PLATES SHALL BE BUILDING STANDARDS COLOR. H. ALL DIMENSIONS SHOW ARE TO CENTERLINE OF OUTLETS OR GROUP OF OUTLETS, UNLESS OTHERWISE NOTED. I. DO NOT LOCATE BOXES BACK TO BACK WITHIN PARTITIONS. STAGGER AS REQUIRE TO MINIMIZE SOUND TRANSMISSION. J. ADJACENT OUTLETS SHALL BE GANGED WHEN POSSIBLE. IF THEY CANNOT BE GANGED, THEY SHALL BE INSTALL WITH A MIN. DISTANCE BETWEEN UNITS. K. CONTRACTOR TO PROVIDE ALL FIRE LIFE SAFETY DEVICES AS REQUIRED BY STATE AND LOCAL BUILDING CODES. L. ELECTRICAL CONTRACTOR TO VERIFY WORKING CONDITION OF ALL SWITCHES, LIGHT FIXTURES, BALLASTS, EXITAND EMERGENCY LIGHTS AND OUTLETS, REPLACE IF NECESSARY. M. DO NOT SCALE DRAWINGS; ALL DIMENSIONS GIVEN ARE TO BE ADHERED TO, UNLESS FIELD CONDITIONS DEEM OTHERWISE. ANY CONFLICTS THAT MAY EXIST WITH NEW CONSTRUCTION MUST BE REVIEWED BY DESIGNER PRIOR TO CONSTRUCTION OR WORK. DO NOT CIRCUMVENT DIMENSIONS BY ATTACHED RECEPTACLES TO NEAREST STUD. N. THESE ELECTRICAL DRAWINGS REFLECT LOCATIONS ONLY. CONSULT WITH ELECTRICAL ENGINEER FOR FURTHER TECHNICAL INFORMATION. O. ELECTRICAUDATA OUTLET LOCATION TO BE VERIFIED WITH TENANT PRIOR TO ROUGH - IN. ALL LOCATIONS TO BE VERIFIED WITH FURNITURE PLACEMENT. P. SYSTEMS FURNITURE TO BE DRAWING ON FLOOR PRIOR TO PLACEMENT OF FLOOR CORE AND JUNCTION BOXES. DESIGNER TO APPROVE LOCATIONS PRIOR TO CORING/PLACEMENT. Q. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR CONNECTING DEALER PROVIDED FURNITURE SYSTEMS POWER IN -FEED TO BUILDING J-BOX ® WHERE INDICATED ON PLAN. ELECTRICAL/DATA KEYNOTES 1. POKE -THROUGH FITTING FOR SYSTEM FURNITURE POWER INFEED FOR ELECTRICFIED WORKSTATION PANELS. SYSTEM FURNITURE WHIP TO BE HARDWIRED DIRECTLY TO POKE -THROUGH. COORDINATE LOCATION IN FIELD WITH TENANT FURNITURE VENDOR. REFER TO ENGINEERING DRAWINGS FORADDITIONAL INFORMATION. 2. REFER TO ELEVATIONS FOR ADDITIONAL INFORMATION AND EXACT LOCATION OF ALL NEW DEVICES AT MILLWORK CABINETS AND ABOVE COUNTERTOP. 3. FURNISH AND INSTALL DEVICES SHOWN FOR OWNER PROVIDED AND INSTALLED TELEVISION. COORDINATE EXACT LOCATIONS AND REQUIREMENTS WITH OWNER PRIOR TO ROUGH -IN. 4. POKE -THROUGH FITTING WITH FITTING WITH ELECTRICAL RECEPTACLES, DATA/VOICE OUTLETS, AND A/V CONNECTIONS. DASHED LINE INDICATES CONDUIT PATH BENEATH FLOOR SLAB TO DESIGNATED PARTITION FOR STUB -UP ACCESSIBLE CEILING. COORDINATE LOCATION IN FIELD WITH FURNITURE VENDOR. REFER TO ENGINEERING DRAWINGS FORADDITIONAL INFORMATION. 5. WALL MOUNTED BASE FEEDS FOR ELECTRIFIED WORKSTATION PANELS. COORDINATE LOCATION IN FIELD WITH FURNITURE VENDOR. REFER TO ENGINEERING DRAWINGS FOR ADDITIONAL ENGINEERING. 6. FURNISH AND INSTALL JUNCTION BOX FOR DISHWASHER. REFER TO ENIGNEERING DRAWINGS FOR ADDITIONAL INFORMATION. 1 CONSTRUCTION PLAN SUITE 201 SCALE: 3116" = r-o° RELEASED FOR CONSTRUCTION Subject to compliance with all regulations Of State and Local Codes City of Camel (� �VT�'lawu�aA�+L DATE: \ 09/20/19 MITSCH D E S I G N 200 S. Rangeline Rd. I Suite 226 Carmel, Indiana 46032 317.573.2222 w .nnschdesgn.com 0 r N 7 w I� ^W^� Q 7" z �1 (V O H .t F Z z z F a_J z W Z w Q w 0. W F- J AR00034184 STATE OF O r a o w w a y 0 M 0 w 0 tt k y w W> m W m m O m0 W m0 vWj 00 0L 0 iFU O M offd moo m o m aL IDEss, DESIGNSAND P S IDRIDINALWORKS DP AUTHgiSHIP FIXED IN ATANGIBLE IEIi EfPflES9g1) INDICATED OR PRESENTED BY THESE DRA W INGB AND COCU MENTS PRE O W NED RY, AND ARE THE PROPERTY OE MRSCH DESIGN. PLLHIGHTS RESERVED, EXCEPL Fqt USES EXPRESSLY PERMITTED IN WRITING ELECTRICALIDATA PLAN - SUITE 210 (LOCATION ONLY) A252