HomeMy WebLinkAboutA252_ElectricalSte210ELECTRICAL LEGEND
iiiiiiiiiiiiiiiiiiiiiillillillillillillilliillillilillillillillillillillillillillillillillillillilliillillillillillillilliillillillillilI
NOT IN CONTRACT
STANDARD DUPLEX RECEPTACLE
STANDARD QUAD DUPLEX RECEPTACLE
STANDARD DEDICATED DUPLEX RECEPTACLE
STANDARD RECEPTACLE (VOICE/DATA)
OO STANDARD FLOOR RECEPTACLE (POWER)
�"- STANDARD FLOOR RECEPTACLE (POWER W/ WHIP)
®--- STANDARD FLOOR RECEPTACLE (VOICE/DATA W/ WHIP)
GFI DENOTES GROUND FAULT INTERRUPTER
t
N DENOTES ITEM FOR TENANT PROVIDED TV
+pp DENOTES CENTERLINE MOUNTING HEIGHT OF OUTLET/RECEPTACLE
NOTE: ELECTICAL ITEMS FOR LOCATION PURPOSES ONLY.
GENERAL ELECTRICAL/DATA NOTES
A. THE ELECTRICAL CONTRACTOR SHALL NOTIFY THE DESIGNER OF ANY DISCREPANCIES
BETWEEN THE CONTRACT DOCUMENTS AND APPLICABLE CODES PRIOR TO
CONSTRUCTION.
B. ELECTRICAL CONTRACTOR TO COORDINATE ALL SPECIAL ELECTRICAL EQUIPMENT
REQUIREMENTS AS INDICATED ON DRAWINGS OR AS REQUIRED BY TENANT. VERIFY
ACTUAL REQUIREMENTS WITH DESIGNER PRIOR TO INSTALLATION.
C. ELECTRICAL CONTRACTOR TO PROVIDE JUNCTION BOXES AND PULL STRINGS AT
TELEPHONE/DATA LOCATIONS AS INDICATED ON PLANS. COMPLETE TELEPHONE/DATA
SYSTEMS (MATERIAL AND LABOR) TO BE PROVIDED BY THE TENANT UNLESS
OTHERWISE NOTED.
D. ALL SECURITY SYSTEMS TO BE PROVIDED BY TENANT UNLESS NOTED OTHERWISE
E. ELECTRICAL CONTRACTOR SHALL COORDINATE ALL ELECTRICAL AND LIGHTING
REQUIREMENTS FOR MILLWORK AND CABINETRY WITH CONTRACTOR AS NECESSARY.
F. ALL WALL MOUNTED OUTLETS ARE TO BE MOUNTED VERTICALLY AT 18" A.F.F. TO
CENTERLINE OF OUTLET, UNLESS OTHERWISE NOTED.
G. SWITCH PLATES, MONUMENTS, AND ELECTRICAL COVER PLATES SHALL BE BUILDING
STANDARDS COLOR.
H. ALL DIMENSIONS SHOW ARE TO CENTERLINE OF OUTLETS OR GROUP OF OUTLETS,
UNLESS OTHERWISE NOTED.
I. DO NOT LOCATE BOXES BACK TO BACK WITHIN PARTITIONS. STAGGER AS REQUIRE TO
MINIMIZE SOUND TRANSMISSION.
J. ADJACENT OUTLETS SHALL BE GANGED WHEN POSSIBLE. IF THEY CANNOT BE
GANGED, THEY SHALL BE INSTALL WITH A MIN. DISTANCE BETWEEN UNITS.
K. CONTRACTOR TO PROVIDE ALL FIRE LIFE SAFETY DEVICES AS REQUIRED BY STATE
AND LOCAL BUILDING CODES.
L. ELECTRICAL CONTRACTOR TO VERIFY WORKING CONDITION OF ALL SWITCHES, LIGHT
FIXTURES, BALLASTS, EXITAND EMERGENCY LIGHTS AND OUTLETS, REPLACE IF
NECESSARY.
M. DO NOT SCALE DRAWINGS; ALL DIMENSIONS GIVEN ARE TO BE ADHERED TO, UNLESS
FIELD CONDITIONS DEEM OTHERWISE. ANY CONFLICTS THAT MAY EXIST WITH NEW
CONSTRUCTION MUST BE REVIEWED BY DESIGNER PRIOR TO CONSTRUCTION OR
WORK. DO NOT CIRCUMVENT DIMENSIONS BY ATTACHED RECEPTACLES TO NEAREST
STUD.
N. THESE ELECTRICAL DRAWINGS REFLECT LOCATIONS ONLY. CONSULT WITH
ELECTRICAL ENGINEER FOR FURTHER TECHNICAL INFORMATION.
O. ELECTRICAUDATA OUTLET LOCATION TO BE VERIFIED WITH TENANT PRIOR TO ROUGH -
IN. ALL LOCATIONS TO BE VERIFIED WITH FURNITURE PLACEMENT.
P. SYSTEMS FURNITURE TO BE DRAWING ON FLOOR PRIOR TO PLACEMENT OF FLOOR
CORE AND JUNCTION BOXES. DESIGNER TO APPROVE LOCATIONS PRIOR TO
CORING/PLACEMENT.
Q. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR CONNECTING DEALER PROVIDED
FURNITURE SYSTEMS POWER IN -FEED TO BUILDING J-BOX ® WHERE INDICATED ON PLAN.
ELECTRICAL/DATA KEYNOTES
1. POKE -THROUGH FITTING FOR SYSTEM FURNITURE POWER INFEED FOR ELECTRICFIED
WORKSTATION PANELS. SYSTEM FURNITURE WHIP TO BE HARDWIRED DIRECTLY TO
POKE -THROUGH. COORDINATE LOCATION IN FIELD WITH TENANT FURNITURE VENDOR.
REFER TO ENGINEERING DRAWINGS FORADDITIONAL INFORMATION.
2. REFER TO ELEVATIONS FOR ADDITIONAL INFORMATION AND EXACT LOCATION OF ALL
NEW DEVICES AT MILLWORK CABINETS AND ABOVE COUNTERTOP.
3. FURNISH AND INSTALL DEVICES SHOWN FOR OWNER PROVIDED AND INSTALLED
TELEVISION. COORDINATE EXACT LOCATIONS AND REQUIREMENTS WITH OWNER
PRIOR TO ROUGH -IN.
4. POKE -THROUGH FITTING WITH FITTING WITH ELECTRICAL RECEPTACLES, DATA/VOICE
OUTLETS, AND A/V CONNECTIONS. DASHED LINE INDICATES CONDUIT PATH BENEATH
FLOOR SLAB TO DESIGNATED PARTITION FOR STUB -UP ACCESSIBLE CEILING.
COORDINATE LOCATION IN FIELD WITH FURNITURE VENDOR. REFER TO ENGINEERING
DRAWINGS FORADDITIONAL INFORMATION.
5. WALL MOUNTED BASE FEEDS FOR ELECTRIFIED WORKSTATION PANELS. COORDINATE
LOCATION IN FIELD WITH FURNITURE VENDOR. REFER TO ENGINEERING DRAWINGS
FOR ADDITIONAL ENGINEERING.
6. FURNISH AND INSTALL JUNCTION BOX FOR DISHWASHER. REFER TO ENIGNEERING
DRAWINGS FOR ADDITIONAL INFORMATION.
1 CONSTRUCTION PLAN SUITE 201
SCALE: 3116" = r-o°
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
Of State and Local Codes
City of Camel (�
�VT�'lawu�aA�+L
DATE: \ 09/20/19
MITSCH
D E S I G N
200 S. Rangeline Rd. I Suite 226
Carmel, Indiana 46032
317.573.2222
w .nnschdesgn.com
0
r
N
7
w
I�
^W^�
Q
7"
z
�1
(V
O
H
.t
F
Z
z
z
F
a_J
z
W
Z
w
Q
w
0.
W
F-
J
AR00034184
STATE OF
O
r
a
o
w
w
a
y
0
M
0
w
0
tt
k
y
w
W>
m
W m
m
O
m0
W
m0 vWj
00
0L
0
iFU
O
M
offd
moo
m o m
aL IDEss, DESIGNSAND P S IDRIDINALWORKS DP
AUTHgiSHIP FIXED IN ATANGIBLE IEIi EfPflES9g1)
INDICATED OR PRESENTED BY THESE DRA W INGB AND
COCU MENTS PRE O W NED RY, AND ARE THE PROPERTY OE
MRSCH DESIGN. PLLHIGHTS RESERVED, EXCEPL Fqt USES
EXPRESSLY PERMITTED IN WRITING
ELECTRICALIDATA
PLAN - SUITE 210
(LOCATION ONLY)
A252