Loading...
HomeMy WebLinkAboutC0.0.Title Sheet (V2)SITE VALVOLINE INSTANT OIL CHANGE 9835 MICHIGAN ROAD - LOT '1A' of NORTH AUGUSTA CIVIL CONSTRUCTION PLANS PROJECT DEVELOPER: CARMEL, INDIANA 46032 C0.0 VICINITY MAP SHEET OF PROJECT NUMBER DRAWING NUMBER VIOC.001 PROJECT VICINITY 160 West Carmel Drive, Suite 240 Carmel, Indiana 46032 Phone: (317) 810-1677 Fax: (317) 810-1679 Email: bcross@civilsite.net GROUP, INC 07/17/2019 VALVOLINE INSTANT OIL CHANGE 100 VALVOLINE WAY LEXINGTON, KENTUCKY 40509 Email: richard.gallegos@valvoline.com Phone: (972) 202-6674 ATTN: Richard Gallegos, Project Manager CONSTRUCTION PLAN INDEX PROF E SS ION A L E NG INEERIND IA NA PE10910647 STATE OF -oNREGIS TER E DBR IA N S CR O SSREVISION RECORD DEVELOPMENT SUMMARY PROPOSED USE: AUTOMOBILE OIL CHANGE FACILITY TOTAL SITE AREA = 0.98± Ac. TOTAL DISTURBED AREA = 41,183± SF = 0.95± Ac PROPOSED BUILDING GROSS SQUARE FOOTAGE = 2,030 S.F. PROPOSED BUILDING COVERAGE RATIO = 4.8% OF SITE AREA OVERLAY ZONE = US 421 - MICHIGAN ROAD CORRIDOR CURRENT ZONING = B3 (BUSINESS DISTRICT) MAX. FRONT YARD SETBACK DISTANCE = 120' BUILDING SETBACKS BUILDING SETBACKS REQUIRED FRONT = 37.7' FRONT = 30' REAR = 174.1' REAR = 15' SIDE = 45' SIDE = 15' **APPROVED VARIANCES** DOCKET No. 17120014V (9.5' BUILDING SETBACK GRANTED) DOCKET No. 17120015V (SIGNAGE APPROVAL) ANTICIPATED CONSTRUCTION START/COMPLETION DATE SEPTEMBER, 2019 / OCTOBER, 2020 TOTAL PARKING SPACES = 11 EXISTING RIGHT-OF-WAY NOTE DAMAGE TO THE EXISTING RIGHT-OF-WAY SHALL BE RESTORED/REPAIRED TO THE SATISFACTION OF THE CITY AT THE COMPLETION OF THE PROJECT. THE CONTRACTOR IS ENCOURAGED TO INSPECT THE RIGHT-OF-WAY WITH THE CITY PRIOR TO THE START OF CONSTRUCTION TO DOCUMENT THE EXISTING CONDITION OF THE RIGHT-OF-WAY. ENGINEER: OPERATING AUTHORITY CITY OF CARMEL DEPT. OF ENGINEERING ONE CIVIC SQUARE CARMEL, INDIANA 46032 PHONE: 317-571-2441 FAX: 317-571-2439 SURVEYOR CENTRAL STATES CONSULTING, LLC. 23-B NORTH GREEN STREET BROWNSBURG, INDIANA 46112 Ph: (317) 858-8662 ATTN: Donald Mosson CARMEL ENGINEERING DEPT. NOTE ALL PAVING WITHIN THE EXISTING AND PROPOSED CITY RIGHT-OF-WAY SHALL CONFORM TO THE REQUIREMENTS OF THE DEPARTMENT OF ENGINEERING. THE CONTRACTOR SHALL CONTACT THE DEPARTMENT OF ENGINEERING TO SCHEDULE A PRE-CONSTRUCTION MEETING TO REVIEW THE DEPARTMENT'S CONSTRUCTION REQUIREMENTS, STAFF NOTIFICATION REQUIREMENTS, REQUIRED INSPECTIONS FOR CERTAIN STAGES OF THE WORK AND TO REVIEW THE AUTHORITY OF THE DEPARTMENT AS IT RELATES TO WORK WITHIN THE EXISTING AND PROPOSED RIGHT-OF-WAY. LAND DESCRIPTION BENCHMARK