HomeMy WebLinkAboutElectricalLEGEND
GENERAL NOTES
PLAN NOTES
NEW CONSTRUCTION EXISTING TO REMAIN
POWER OUTLET, DUPLEX
.N,
^N'
POWER OUTLET,
QUADRUPLE%
Q
JUNCTION BOX
QJ
OCEILING
MOUNTED
J
JUNCTION BOX
®
BOX, BLANK COVER PLATE
®
BOX, OPEN
QO
P
PROVIDE JUNCTION BOX
P
9
ABOVE CEILING FOR
O
POWER POLE
CONNECTION, POWER
POLE BY OTHERS.
POWER OUTLET, DUPLEX
POWER OUTLET,
QUADRUPLE%
JUNCTION BOX
CEILING MOUNTED
JUNCTION BOX
BOX, BLANK COVER PLATE
BOX, OPEN
POWER AND DATA POLE
FLOOR BOX WTH POWER
FLOOR BOX WITH POWER
F6I®
AND DATA, FLUSH
6b
AND DATA, FLUSH
MOUNTED
MOUNTED
FLOOR BOX WTH
FLOOR BOX WITH
®
JUNCTION BOX AND
JUNCTION BOX AND
DATA, FLUSH MOUNTED
DATA, FLUSH MOUNTED
DATA/COMMUNICATION
DATA/COMMUNICATION
11
OUTLET (PROVIDE BOX
b
OUTLET
AND PULL STRING ONLY(
DED
DEDICATED CIRCUIT
GFCI
GROUND FAULT CIRCUIT
INTERRUPT OUTLET
+42'
HEIGHT OF ELECTRICAL
OR DATA DEVICE
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and Local Codes
City d Camel
DATE: 09/24/19
I. TENANT'S FURNITURE VENDOR IS RESPONSIBLE FOR I NSTALLATI ON OF FURNITURE AND FIELD
VERIFICATION OF ALL CRTICAL DIMENSIONS.
2. ALL OUTLETS ARE TO INSTALLED l MIN.A.F.F.TOTHE CENTER OF THE DEVICE PER ADA GUIDELINES
UNLESS NOTED OTHERWISE, ALL NEW DEVICES AND FACE PLATES TO BE WHITE,
3. REFER TO DOOR SCHEDULE AND COORDINATE WITH TENANT/OWNER REGARDING POWER
LOCATIONS TO ACCOMMODATE ELECTRIC STRIKES, CARD READERS AND/OR MAG-LOCKS.
CARD READERS ARE TYPICALLY INSTALLED BY THE TENANT'S SECURITY CONTRACTOR AND NOT
SPECIFIED BY SDI.
4. ELECTRICAL WORK IS LIMITED TO A DESIGN -BUILD SCOPE AND IS OUTLINED IN THESE DRAWINGS.
ALL ELECTRICAL WORK IS LIMITED TO ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET
DEVICES AND LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE EXISTING ELECTRICAL
SERVICE IN THE BUILDING. ELECTRICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF
ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY
WITH ALL APPLICABLE CODES,
5. MICROWAVES, REFRIGERATORS, WATER COOLER, AND DISHWASHER TO BE ON SEPARATE
CIRCUITS.
6. PROVIDE WHITE NOISE SYSTEM THROUGHOUT SUITE, COORDINATE SPEAKER AND CONTROLS
LOCATIONS WITH TENANTAS REQUIRED.
PROVIDE POWER AS REQUIRED FOR ELECTRIC STRIKE AT DOOR FOR CARD READER (CARD READER PROVIDE (2) RECESSED POP-UP POWER IN COUNTER (MOCKETi'S PCS82B/UI -POP-UP POWER
E01 BY TENANT. COORDINATE WITH TENANTE07
'S SECURITY CONTRACTOR. SEE DOOR SCHEDULE FOR GROMMET-2 POWER/ I DUAL USB CHARGER, COLOR TBD( OR EQUAL: CONFIRM EXACT
MORE DETAILS.
LOCATION WITH TENANT,
E02
COORDINATE COPIER RECEPTACLE WITH TENANT. PROVIDE DEDICATED RECEPTACLE AS REQUIRED.
PROVIDE POWER AT THIS LOCATION FOR TENANT'S DISHWASHER, GARBAGE DISPOSAL, AND
E08
WATER DISPENSER.
PROVIDE JUNCTION BOX AND DATA FOR TENANT'S FURNITURE SYSTEM. COORDINATEE%ACT
E03
O
LOCATION WITH TENANT'S FURNITURE VENDOR.
PROVIDE I DEDICATED 120V DUPLEX IN THIS ROOM. COORDINATE WITH TENANT FOR EXACT
I
E09
LOCATIONS AND ANY ADDITIONAL IT ROOM REQUIREMENTS.
PROVIDE DEDICATED POWER OUTLET IN RECESSED BOX INSET INTO CABINET/ WALL FOR EACH OF
E04
TENANT' MICROWAVES; RDINATE OUTLET HEIGHT WITH MILLWORK ELEVATION,
S COO OU G O O.
PROVIDE FLUSH MOUNT FLOOR CORE WITH POKE THRU DEVICE FOR ELECTRICAL, DATA, AND
OE10
HDMI. PROVIDE DIRECT HDMI VGA CONDUIT CONNECTION FROM FLOOR CORE POKE THRU
POWER AND DATA FOR TENANTS WALL MOUNTED TELEVISION AT HEIGHT NOTED ON
DEVICE i0WALL MOUNTED MOTRCOORDINATE WITH TENANTS FURNITURE VENDOR ON
OPROVIDE
E06
PLAN. COORDINATE EXACT LOCATION WITH TENANT.
ERLOCATION, PROVIDE POKEKETHRN DEVICE SUBMITTAL iOTENANT FOR APPROVAL PRIOR TO
ORDERING.
OPROVIDE FLUSH MOUNT FLOOR CORE WITH POKE THRU DEVICE FOR JUNCTION BOX AND DATA.
E06 COORDINATE WTH TENANTS FURNITURE VENDOR ON EXACT LOCATION. PROVIDE POKE THRU E71 PROVIDE DEDICATED OUTLETS FOR TENANT'S VENDING MACHINES.
DEVICE SUBMITTAL TO TENANT FOR APPROVAL PRIOR TO ORDERING.
AREA NOT IN CONTRACT
AREA OF WORK
ELECTRICAL PLAN
0 2' 4' 8' 16'
"I
THIS DRAWING. AND THE IDEAS,
DESIGNS AND CONCEPTS CONTAINED
HEREIN, ARE THE EXCLUSIVE
INTELLECTUAL PROPERTY OF SCH07
DESIGN, INC., AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE, OR
IN PART, WITHOUT THE WRITTEN
CONSENT OF SCH07 DESIGN.
Z
W
N
N
p
o
Win
Iq
LULU
Z
0�
W
ZNry
QZ
U
Z
W
La
>
a
m
III
Q
I
0
ry
J
LU
LUZ
LLJI
~
Q
Z
W
W
U
r
LU
>
U
�
o
ZU
70
LU
W
ISSUE
DATE
DESCRIPTION
08.08.19
REVIEWSET
08.1?.1?
PERMITSET
REVISIONS
MAR DATE DR DESCRIPTION
IN 0.
AR10700017
STATE OF
PROJECT NUMBER
2019.226
PROD. Ml DRAWN BY
I EH JJ
3RD FLOOR
ELECTRICAL PLAN