CODE SUMMARY
SCOPE OF WORK
OFFICE REMODEL OF PREVIOUSLY BUILT -OUT OFFICE SPACE
PREVIOUS USE OF SPACE
BUSINESS(
OCCUPANCY C LASSIFICATION
BUSINESS(
CHANGE OF OCCUPANCY CLASS?
NO
TOTAL BUILDING AREA
45,576 SF/FLOOR
X
1 3 STORIES
=
136.728 SF
TOTAL PROJECT AREA
OCCUPANCYCALCULATIONS
NUMBER OF EXITS
12,837 SF
SPACE TYPE AREA SF PER OCCUPANT OCCUPLOAD
GEN. OFFICE
11,936 SF
100
119
BREAK ROOM 305
1 901 SF
15
60
TOTAL OCCUPANTS IN PROJECT AREA 179
REQUIRED:2 PROVIDED:3
SPRINKLER SYSTEM( YES/NO(
YES- EXISTINGTO REMAIN
TOTAL AREA OF ACCESSORY USES
0 SF
TOTAL AREA ON THE FLOOR
45,576 SF
ACCESSORY AREA EXCEEDS 10%
NO
FIRE WALLS, AND/OR OCCUPANCY
SEPARATIONS (IF REQUIRED(
N/A
ASHRAE 90.1 SUMMARY
REQUIREMENTS WILL BE MET (SEE REFLECTED CEILING PLAN(
BUILT BEFORE 1978?
NO
BUILDING CONSTRUCTION TYPE
ll
LEGEND
Ep EXISTING ELECTRICAL PANEL LOCATION
EX EXISTING EXIT. EXISTING BUILDING STAIR
i
FIRE EXTINGUISHER
EXIT SIGN
I&
EMERGENCY LIGHT
— — —
TRAVEL DISTANCE
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and Local Codes
City of Camel
�VT�LJ'�D*S41WML
DATE: \ 09/24/19
i
AREA NOT IN CONTRACT
AREA OF WORK
LIFE SAFETY NOTES
1. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER
NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS
CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF
THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON
PLAN ARE FOR REFERENCE ONLY.
2. PROVIDE ALARM NOT FICATION APPLIANCES(HORNS/BTROBEB(,
EMERGENCY SPEAKERS, SMOKE DETECTORS, FI RE PULLS, AND ANY
OTHER REQUIRED ALARM & DETECTION SYSTEMS AS NECESSARY TO
MEET ALL APPLICABLE CODES (INTERNATIONAL BUILDING CODE,
INTERNATIONAL FIRE CODE, NFPA. IN RECEPTION AREAS,
CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN SUITE,
ALL LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDI OR
TENANT PRIOR TO INSTALLATION. FAILURE TO DO SO MAY RESULT IN
CONTRACTOR RELOCATING THESE ITEMS AT THEIR EXPENSE.
3. FIRE EXTINGUISHERS: CONTRACTOR TO ENSURE ALL NEW AND
EXISTING FIRE EXTINGUISHERS ARE INSTALLED ACCORDING TO NFPA
10. COORDINATE WITH OWNER/LANDLORD ON EXTINGUISHER TYPE
AND HOUSING. MAXIMUM TRAVEL DISTANCE OF 75 FEET FROM ANY
POINT TO A VISIBLE EXTINGUISHER.
THE FOLLOWING NOTES APPLY ONLY IN EXISTING SPRINKLERED FACILITIES.
4. FIRE PROTECTION WORK IS TO BE PROVIDED BY DESIGN/BUILD
SERVICES UNDER THE GENERAL CONTRACT. PROVIDE A COMPLETE,
WORKING SYSTEM. SCHOTT DESIGN, INC., IS NOT RESPONSIBLE FOR
THE DESIGN, INSTALLATION, OR RENOVATION OF THE FIRE SPRINKLER
SYSTEM.
5. THE FIRE PROTECTION CONTRACTOR SHALL GENERATE ALL REQUI RED
DRAWINGS, AND SHALL FILE THOSE DRAWINGS, AND RELATED
DOCUMENTS, WITH THE STATE AND LOCAL AUTHORITIES HAVING
JURISDICTION OVER THE PROJECT.
GENERAL NOTES
Ll. REFER TO ARCHITECTURAL PLAN FOR WALL TYPE AND CONSTRUCTION
DETAILS.
L2. EXISTING EXIT SIGNS, FIRE PULLS, FIRE EXTINGUISHERS, ALARM
NOTIFICATION APPLIANCES TO REMAIN. RELOCATE EXISTING EXIT
SIGNS, FIRE PULLS, FIRE EXTINGUISHERS AND ALARM NOTIFICATIONS AS
REQUIRED TO MEET ALL LOCAL AND STATE CODES.
LIFE SAFETY PLAN
0 4' 8' 16,
N
THIS DRAWING, AND THE IDEAS,
DESIGNS AND CONCEPTS CONTAINED
HEREIN, ARE THE EXCLUSIVE
INTELLECTUAL PROPERTY OF SCH07
DESIGN, INC., AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE, OR
IN PART, WITHOUT THE WRITTEN
CONSENT OF SCH 07 DESIGN.
Z
W
N
Hp
CO
.O
v
LU
LU
z
N
Z
F
QZ
U
U
Z
W
LLJ
CL
J
LU
�
H
Q
Z
LU
U
W
U
''
LU
>
U
CD
ZU
REVISIONS
I MARK DATE I DB DESCRIPTION
Ni
AR10700017
STATE OF
PROJECT NUMBER
2019.226
FiMGR DRAWN BY
I EH JJ
3RD FLOOR
LIFE SAFETY
L 100