HomeMy WebLinkAboutLife Safety Plan2 3 4 5 6 7 B 9 10 11 12 13 14 15 16 CODE SUMMARY SCOPE OF WORK OFFICE REMODEL OF PREVIOUSLY BUILT -OUT OFFICE SPACE PREVIOUS USE OF SPACE BUSINESS( OCCUPANCY C LASSIFICATION BUSINESS( CHANGE OF OCCUPANCY CLASS? NO TOTAL BUILDING AREA 45,576 SF/FLOOR X 1 3 STORIES = 136.728 SF TOTAL PROJECT AREA OCCUPANCYCALCULATIONS NUMBER OF EXITS 12,837 SF SPACE TYPE AREA SF PER OCCUPANT OCCUPLOAD GEN. OFFICE 11,936 SF 100 119 BREAK ROOM 305 1 901 SF 15 60 TOTAL OCCUPANTS IN PROJECT AREA 179 REQUIRED:2 PROVIDED:3 SPRINKLER SYSTEM( YES/NO( YES- EXISTINGTO REMAIN TOTAL AREA OF ACCESSORY USES 0 SF TOTAL AREA ON THE FLOOR 45,576 SF ACCESSORY AREA EXCEEDS 10% NO FIRE WALLS, AND/OR OCCUPANCY SEPARATIONS (IF REQUIRED( N/A ASHRAE 90.1 SUMMARY REQUIREMENTS WILL BE MET (SEE REFLECTED CEILING PLAN( BUILT BEFORE 1978? NO BUILDING CONSTRUCTION TYPE ll LEGEND Ep EXISTING ELECTRICAL PANEL LOCATION EX EXISTING EXIT. EXISTING BUILDING STAIR i FIRE EXTINGUISHER EXIT SIGN I& EMERGENCY LIGHT — — — TRAVEL DISTANCE RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Camel �VT�LJ'�D*S41WML DATE: \ 09/24/19 i AREA NOT IN CONTRACT AREA OF WORK LIFE SAFETY NOTES 1. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY. 2. PROVIDE ALARM NOT FICATION APPLIANCES(HORNS/BTROBEB(, EMERGENCY SPEAKERS, SMOKE DETECTORS, FI RE PULLS, AND ANY OTHER REQUIRED ALARM & DETECTION SYSTEMS AS NECESSARY TO MEET ALL APPLICABLE CODES (INTERNATIONAL BUILDING CODE, INTERNATIONAL FIRE CODE, NFPA. IN RECEPTION AREAS, CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN SUITE, ALL LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDI OR TENANT PRIOR TO INSTALLATION. FAILURE TO DO SO MAY RESULT IN CONTRACTOR RELOCATING THESE ITEMS AT THEIR EXPENSE. 3. FIRE EXTINGUISHERS: CONTRACTOR TO ENSURE ALL NEW AND EXISTING FIRE EXTINGUISHERS ARE INSTALLED ACCORDING TO NFPA 10. COORDINATE WITH OWNER/LANDLORD ON EXTINGUISHER TYPE AND HOUSING. MAXIMUM TRAVEL DISTANCE OF 75 FEET FROM ANY POINT TO A VISIBLE EXTINGUISHER. THE FOLLOWING NOTES APPLY ONLY IN EXISTING SPRINKLERED FACILITIES. 4. FIRE PROTECTION WORK IS TO BE PROVIDED BY DESIGN/BUILD SERVICES UNDER THE GENERAL CONTRACT. PROVIDE A COMPLETE, WORKING SYSTEM. SCHOTT DESIGN, INC., IS NOT RESPONSIBLE FOR THE DESIGN, INSTALLATION, OR RENOVATION OF THE FIRE SPRINKLER SYSTEM. 5. THE FIRE PROTECTION CONTRACTOR SHALL GENERATE ALL REQUI RED DRAWINGS, AND SHALL FILE THOSE DRAWINGS, AND RELATED DOCUMENTS, WITH THE STATE AND LOCAL AUTHORITIES HAVING JURISDICTION OVER THE PROJECT. GENERAL NOTES Ll. REFER TO ARCHITECTURAL PLAN FOR WALL TYPE AND CONSTRUCTION DETAILS. L2. EXISTING EXIT SIGNS, FIRE PULLS, FIRE EXTINGUISHERS, ALARM NOTIFICATION APPLIANCES TO REMAIN. RELOCATE EXISTING EXIT SIGNS, FIRE PULLS, FIRE EXTINGUISHERS AND ALARM NOTIFICATIONS AS REQUIRED TO MEET ALL LOCAL AND STATE CODES. LIFE SAFETY PLAN 0 4' 8' 16, N THIS DRAWING, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCH07 DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCH 07 DESIGN. Z W N Hp CO .O v LU LU z N Z F QZ U U Z W LLJ CL J LU � H Q Z LU U W U '' LU > U CD ZU REVISIONS I MARK DATE I DB DESCRIPTION Ni AR10700017 STATE OF PROJECT NUMBER 2019.226 FiMGR DRAWN BY I EH JJ 3RD FLOOR LIFE SAFETY L 100