Loading...
HomeMy WebLinkAboutA121.A ENLARGED FIRST FLOOR REFLECTED CEILING PLANI — — — — — — a GVF' 14'-10 UB" '-,j 91 `0 a j RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Cannel eH el eJ K eL N FIRST FLOOR RCP 121. 3/32" = V-0" KEYED REF. CEILING PLAN NOTES (NOTED WITH 0 ) 1 ALIGN FACE OF BULKHEAD W/ FACE OF ADJACENT WALL 2 V 6 6 E EE /�2/ ARM STRONG 24"X24" WOODWORKS GRILLE TEGULAR TILES ON A Q SUSPENSION SYSTEM WITH HORIZONTAL SLATS WITH 4' AXIOM WO TRIM 4 IG E W H / O TI L D- PATCH EXISTING BULKHEAD SO TRANSITION APPEARS SEAMLESS 5 EXPOSED CEILING 6 EXISTING BULKHEAD TO REMAIN 7 AREA OF NEW CEIING GRID INFILLAND NEW CEILING TILES. CONTRACTOR TO COORDINATE CONNECTION TO RE -USED CEILING GRID AS REQUIRED FOR UNIFORM CEILING HEIGHT AND APPEARANCE 8 AREA OF RE -USED CEILING GRID WITH NEW CEILING TILES. CONTRACTOR TO CORDINATE CONNECTION BETWEEN NEW AND EXISTING CEILING GRID; SPLICE AND REHANG CEILING AS REQUIRE FOR A UNIFORM HEIGHTAND APPEARANCE. PROVIDE 20% CONTINGENCY TO CLEAN, REPAIR AND PAINT EXISTING GRID WHERE DAMAGED 9 EXISTING CEILING TO REMAIN, PATCH AND REPAIR AS NEEDED 10 OVERHEAD SECURITY GRILLE - REF. SHEETA501 eK 02 COFFEE SHOP RCP A! 1/4" = V-0" REFLECTED CEILING PLAN LEGEND A. PLL CEILINGS TO BE ACT-1 U.N.O. B. ALL A.C.T. CEILINGSTO BE 9-TA.F.F. USING 1511TWHITE METALTEE GRID. U.N.O. C. PROVIDE 3-112" SOUND BATTS OVER CEILING IN ENTIRE ROOM AND 24" BEYOND OUTSIDE WALL AT ALL TOILETS AND CONFERENCE ROOMS WITH SOUND RATED WALLS, D. ALL GYPSUM BOARD CEILINGS TO BE T-TA.FF. UNLESS NOTED OTHERWISE E. GYPSUM BOARD CONTROL JOINTS: a. PROVIDE AT INTERIOR CEILINGS (WITH PERIMETER RELIEF)OVER W-0'IN LENGTH IN MY DIRECTION. TOTAL AREA BETWEEN CONTROL JOINTS SHALL NOT EXCEED 2500 SOFT b. PROVIDE AT INTERIOR CEILINGS (WITHOUT PERIMETER RELIEF)OVER 30'-0"IN LENGTH IN ANY DIRECTION. TOT& AREA BETWEEN CONTROL JOINTS SHPLL NOT EXCEED NO SQFT c. PROVIDE AT EXTERIOR CEILINGS AND SOFFITS OVER 30'-0" IN LENGTH IN ANY DIRECTION. TOTAL AREA BETWEEN CONTROL JOINTS SHALL NOT EXCEED 900 SOFT d. COORDINATE LOCATIONS WITH ARCHITECTURAL ELEMENTS ANDIOR AT THE DIRECTION OF THE ARCHITECT. F. REFERENCE INTERIOR ELEVATIONS FOR GYPSUM BOARD SOFFITS ABOVE CABINETS. G. SEE INTERIOR ELEVATION ANDIOR SECTIONS FOR MOUNTING HEIGHTS OF ANY WPLL MOUNTED LIGHT FIXTURES. ® 2k4'SUSPENDED ACOUSTICAL CEILING W/2X2 LOOK GYPSUM BOARD CEILING CEILING TYPE ACT-1 P80. CEILING IDENTIFICATION FINISH HEIGHT(AFF) CEILING TYPE LEGEND ACT-1 - a4 ACOUSTICAL PANELS W/2X2 LOOK (DUNE' BY ARMSTRONG) GYP-1- 59' TYPE'X GYPSUM BOARD, PAINTED ACT-4- 2X4 ACOUSTICAL PANELS W/2X2 LOOK, SCRUBBABLEI WASHABLE('IOTCHEN ZONE' BY ARMSTRONG — e18 e4 2 e2.7 e2.4 e2.3 — e2 NOTES: A. REFER TO 3I3TSCALE SHEETS FOR PLAN KEYNOTES. B. REFER TO SHEET D121 FOR CEILING DEMOLITION. C. ALL DEMOLITION DIMENSIONS WE PROVIDED FOR REFERENCE ONLY CONTRACTOR SHALL FIELD VERIFY ALL MEASUREMENTS. D. SHADED AREA INDICATES AREA OF PREVIOUS AND FUTURE WORK N *(�:) KEY PLAN 12" = T-0" 31 OAMERICAN M■ STRUCTUREPOINT INC 7260 smeelane srman I imianapoim, Indiana M256 TEL 317.M7.Ra0 I FI1I317.393.0270 www.mururepoim.nam GEICO CORPORATE FIRST FLOOR RENOVATION PHASE 3 101 W. 103RD ST. INDIANAPOLIS, IN 46290 CERTIFIED BY ISSUANCEINDEX DATE: O5/31/'19 PROJECT PHASE: CONSTRUCTION DOCUMENTS PHASE 3 REVISION SCHEDULE NO. DESCRIPTION DATE 1 ADDENDUM 001 07/12/19 3 IPRO01 1 09/05/19 Project Number 2017.01381 ENLARGED FIRST FLOOR REFLECTED CEILING PLAN A121.A DATE: 09/24/19